Does the common topknot Zeugopterus punctatus (Teleosteii: Pleuronectiformes: Scophthalmidae) use a novel Venturi‐effect attachment mechanism? A testable hypothesis

2021 ◽  
Author(s):  
John Davenport ◽  
Vincent Maran ◽  
Bruno Chanet
Author(s):  
John F. Allen

Mitochondria and chloroplasts are energy-transducing organelles of the cytoplasm of eukaryotic cells. They originated as bacterial symbionts whose host cells acquired respiration from the precursor of the mitochondrion, and oxygenic photosynthesis from the precursor of the chloroplast. The host cells also acquired genetic information from their symbionts, eventually incorporating much of it into their own genomes. Genes of the eukaryotic cell nucleus now encode most mitochondrial and chloroplast proteins. Genes are copied and moved between cellular compartments with relative ease, and there is no obvious obstacle to successful import of any protein precursor from the cytosol. So why are any genes at all retained in cytoplasmic organelles? One proposal is that these small but functional genomes provide a location for genes that is close to, and in the same compartment as, their gene products. This co-location facilitates rapid and direct regulatory coupling. Redox control of synthesis de novo is put forward as the common property of those proteins that must be encoded and synthesized within mitochondria and chloroplasts. This testable hypothesis is termed CORR, for co -location for r edox r egulation. Principles, predictions and consequences of CORR are examined in the context of competing hypotheses and current evidence.


1978 ◽  
Vol 48 ◽  
pp. 389-390 ◽  
Author(s):  
Chr. de Vegt

AbstractReduction techniques as applied to astrometric data material tend to split up traditionally into at least two different classes according to the observational technique used, namely transit circle observations and photographic observations. Although it is not realized fully in practice at present, the application of a blockadjustment technique for all kind of catalogue reductions is suggested. The term blockadjustment shall denote in this context the common adjustment of the principal unknowns which are the positions, proper motions and certain reduction parameters modelling the systematic properties of the observational process. Especially for old epoch catalogue data we frequently meet the situation that no independent detailed information on the telescope properties and other instrumental parameters, describing for example the measuring process, is available from special calibration observations or measurements; therefore the adjustment process should be highly self-calibrating, that means: all necessary information has to be extracted from the catalogue data themselves. Successful applications of this concept have been made already in the field of aerial photogrammetry.


Author(s):  
Ben O. Spurlock ◽  
Milton J. Cormier

The phenomenon of bioluminescence has fascinated layman and scientist alike for many centuries. During the eighteenth and nineteenth centuries a number of observations were reported on the physiology of bioluminescence in Renilla, the common sea pansy. More recently biochemists have directed their attention to the molecular basis of luminosity in this colonial form. These studies have centered primarily on defining the chemical basis for bioluminescence and its control. It is now established that bioluminescence in Renilla arises due to the luciferase-catalyzed oxidation of luciferin. This results in the creation of a product (oxyluciferin) in an electronic excited state. The transition of oxyluciferin from its excited state to the ground state leads to light emission.


Author(s):  
Ezzatollah Keyhani

Acetylcholinesterase (EC 3.1.1.7) (ACHE) has been localized at cholinergic junctions both in the central nervous system and at the periphery and it functions in neurotransmission. ACHE was also found in other tissues without involvement in neurotransmission, but exhibiting the common property of transporting water and ions. This communication describes intracellular ACHE in mammalian bone marrow and its secretion into the extracellular medium.


Author(s):  
R. Hegerl ◽  
A. Feltynowski ◽  
B. Grill

Till now correlation functions have been used in electron microscopy for two purposes: a) to find the common origin of two micrographs representing the same object, b) to check the optical parameters e. g. the focus. There is a third possibility of application, if all optical parameters are constant during a series of exposures. In this case all differences between the micrographs can only be caused by different noise distributions and by modifications of the object induced by radiation.Because of the electron noise, a discrete bright field image can be considered as a stochastic series Pm,where i denotes the number of the image and m (m = 1,.., M) the image element. Assuming a stable object, the expectation value of Pm would be Ηm for all images. The electron noise can be introduced by addition of stationary, mutual independent random variables nm with zero expectation and the variance. It is possible to treat the modifications of the object as a noise, too.


Author(s):  
Anthony A. Paparo ◽  
Judith A. Murphy

The purpose of this study was to localize the red neuronal pigment in Mytilus edulis and examine its role in the control of lateral ciliary activity in the gill. The visceral ganglia (Vg) in the central nervous system show an over al red pigmentation. Most red pigments examined in squash preps and cryostat sec tions were localized in the neuronal cell bodies and proximal axon regions. Unstained cryostat sections showed highly localized patches of this pigment scattered throughout the cells in the form of dense granular masses about 5-7 um in diameter, with the individual granules ranging from 0.6-1.3 um in diame ter. Tissue stained with Gomori's method for Fe showed bright blue granular masses of about the same size and structure as previously seen in unstained cryostat sections.Thick section microanalysis (Fig.l) confirmed both the localization and presence of Fe in the nerve cell. These nerve cells of the Vg share with other pigmented photosensitive cells the common cytostructural feature of localization of absorbing molecules in intracellular organelles where they are tightly ordered in fine substructures.


Author(s):  
Shaul Barkan

Cooling down solid state detecors, with other different way then liquid Nitrogen, is a goal of many vendors and customers since the invention of these detectors. THe disadvantage of the common way of liquid Nitrogen is first the inavailibility of the LN in many uses (like space military and any other applications that are not done inside a well organize Laboratory). The use of LN also considers as a Labor consumer in addition to the big dewar that has to be added to any detector for storing the LN, the boiling of the LN, may cause microphonics problesm and the refiling of the dewar in many Labs is a complicated process due to inconvenience location of the microscope.In this paper I will show a spectra result of 10mm2 SiLi detector for microanalysis use, cooled by peltier cooler. The peltier cooler has the advantage of non-microphonics and non-labor needed (like adding LN to the dewar).


Author(s):  
William P. Wergin ◽  
Eric F. Erbe

The eye-brain complex allows those of us with normal vision to perceive and evaluate our surroundings in three-dimensions (3-D). The principle factor that makes this possible is parallax - the horizontal displacement of objects that results from the independent views that the left and right eyes detect and simultaneously transmit to the brain for superimposition. The common SEM micrograph is a 2-D representation of a 3-D specimen. Depriving the brain of the 3-D view can lead to erroneous conclusions about the relative sizes, positions and convergence of structures within a specimen. In addition, Walter has suggested that the stereo image contains information equivalent to a two-fold increase in magnification over that found in a 2-D image. Because of these factors, stereo pair analysis should be routinely employed when studying specimens.Imaging complementary faces of a fractured specimen is a second method by which the topography of a specimen can be more accurately evaluated.


Sign in / Sign up

Export Citation Format

Share Document