Validation of a Numerical Model for the Simulation of Tramcar Vehicle Dynamics by Means of Comparison With Experimental Data

2007 ◽  
Vol 2 (4) ◽  
pp. 299-307 ◽  
Author(s):  
Federico Cheli ◽  
Roberto Corradi ◽  
Giorgio Diana ◽  
Alan Facchinetti

Tramcar vehicles significantly differ from traditional railway vehicles for both the adopted structural configuration and design solutions and the operating conditions. For this reason, a new numerical model specific for the analysis of tramcar dynamics has been developed at Politecnico di Milano. Before the numerical model can be adopted as a means to analyze tramcar dynamics in typical operating conditions, the capability of the model to reproduce the actual tramcar behavior has to be verified. This paper deals with the validation of the proposed numerical model by means of a comparison with experimental data.


Author(s):  
Federico Cheli ◽  
Roberto Corradi ◽  
Giorgio Diana ◽  
Alan Facchinetti

Tramcar vehicles significantly differ from traditional railway vehicles both for the adopted structural configuration and design solutions and for the operating conditions. For this reason, a new numerical model specific for the analysis of tramcar dynamics has been developed by Politecnico di Milano. Before the numerical model can be adopted as a useful mean to analyse tramcar operational problems, the capability of the model to reproduce the actual tramcar dynamic behaviour has to be verified. The paper deals with the validation of the developed numerical model by means of comparison with experimental data.



2021 ◽  
Author(s):  
Wassim Habchi ◽  
Philippe Vergne

Abstract The current work presents a quantitative approach for the prediction of minimum film thickness in elastohydrodynamic lubricated (EHL) circular contacts. In contrast to central film thickness, minimum film thickness can be hard to accurately measure, and it is usually poorly estimated by classical analytical film thickness formulae. For this, an advanced finite-element-based numerical model is used to quantify variations of the central-to-minimum film thickness ratio with operating conditions, under isothermal Newtonian pure-rolling conditions. An ensuing analytical expression is then derived and compared to classical film thickness formulae and to more recent similar expressions. The comparisons confirmed the inability of the former to predict the minimum film thickness, and the limitations of the latter, which tend to overestimate the ratio of central-to-minimum film thickness. The proposed approach is validated against numerical results as well as experimental data from the literature, revealing an excellent agreement with both. This framework can be used to predict minimum film thickness in circular elastohydrodynamic contacts from knowledge of central film thickness, which can be either accurately measured or rather well estimated using classical film thickness formulae.



1990 ◽  
Vol 112 (3) ◽  
pp. 183-190 ◽  
Author(s):  
R. E. Hogan ◽  
R. B. Diver ◽  
Wm. B. Stine

Results from a numerical model of axisymmetric solar cavity receivers are compared with experimental data for tests of a novel test bed receiver in the Sandia National Laboratories solar furnace. The computed energy transfer rates and temperatures are compared with the experimental data for different receiver geometries, aperture sizes, and operating conditions. In general, the agreement between the numerical model and the experimental data is better for the small-to-midsized apertures than for the large apertures. The analysis indicates that for the larger apertures, the convective heat losses are over predicted. It also suggests that these losses could be better characterized. Sensitivity analyses show that both the total solar energy input rate and the convective heat-loss coefficient significantly affect the receiver thermal performance and that the distribution of the input solar flux significantly affects the temperature distribution in the receiver.



2021 ◽  
pp. 1-63
Author(s):  
Thomas Ceyrowsky ◽  
Andre Hildebrandt ◽  
Martin Heinrich ◽  
Rüdiger Schwarze

Abstract A volute's loss coefficient is highly sensitive to Mach number, circumferential velocity and flow rate at volute inlet. In case of a backswept impeller, these parameters are coupled to each other. Therefore, in order to investigate the effects of flowrate and flow angle separately, one would have to vary the diffuser width together with the flowrate, keeping the flow angle constant. This corresponds to coupling the volute with aerodynamically similar impellers, designed for higher and lower flowrates. Since this is elaborate, there is no adequate study available in open literature, assessing a volute's global loss map. In this work, a new numerical approach for the prediction of a volute's representative loss map is presented: The volute is calculated by means of steady CFD as a standalone component. The inlet boundary conditions are carefully selected by means of 1D and applied together with different diffuser widths. This allows for separate investigation of the impacts of flow angle, flow rate and Mach number. Validation against full stage CFD confirms the applicability of the standalone model. The results exhibit that minimum losses do not necessarily occur at the theoretical matching point but either when the volute is smaller or bigger, depending on the inlet flow angle. Investigations of the loss mechanisms at different operating conditions provide useful guidelines for volute design. Finally, the validity of these study's findings for volutes with different geometrical features is examined by comparison with experimental data as well as with fullstage CFD.



Author(s):  
Puya Javidmand ◽  
Klaus A. Koffmann

Although HFC-134a is a common refrigerant for residential and mobile refrigeration systems, investigators are dealing with replacing it with new alternatives because of its harmful environmental and global warming effects. Recently HFO-1234yf and HFO-1234ze have been introduced as suitable alternative refrigerants because they have zero ozone depletion potential (ODP) and low global warming potential (GWP) and possess thermophysical properties similar to those of HFC-134a. Because there is no experimental data on the performance of these new refrigerants in capillary tubes and short-tube orifices, a recently developed numerical model for analysis of critical two-phase flow through these tubes is used to predict the critical mass flow rate and pressure distribution of HFO-1234yf and HFO-1234ze under various operating conditions. The applied numerical model is based on a comprehensive two-fluid model including the effects of two-phase flow patterns and liquid-phase metastability. The numerical method has been validated by comparing numerical results of the critical flows of HFC-134a, R-410A, and HCFC-22 with available experimental data. The developed numerical simulation is applied in order to develop comparison and selection charts for short-tube orifices based on the common refrigerant HFC-134a and the alternative new refrigerants HFO-1234yf and HFO-1234ze.



Metals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 875
Author(s):  
Jie Wu ◽  
Yuri Hovanski ◽  
Michael Miles

A finite element model is proposed to investigate the effect of thickness differential on Limiting Dome Height (LDH) testing of aluminum tailor-welded blanks. The numerical model is validated via comparison of the equivalent plastic strain and displacement distribution between the simulation results and the experimental data. The normalized equivalent plastic strain and normalized LDH values are proposed as a means of quantifying the influence of thickness differential for a variety of different ratios. Increasing thickness differential was found to decrease the normalized equivalent plastic strain and normalized LDH values, this providing an evaluation of blank formability.





Author(s):  
Jin Jiang ◽  
Ruo-ling Zhang ◽  
Jia-ling Le ◽  
Wei-xiong Liu ◽  
Yang Yang ◽  
...  


Sign in / Sign up

Export Citation Format

Share Document