A Control System for a High-Quality Generating Set Equipped With a Two-Shaft Gas Turbine

1991 ◽  
Vol 113 (2) ◽  
pp. 290-295 ◽  
Author(s):  
H. Kumakura ◽  
T. Matsumura ◽  
E. Tsuruta ◽  
A. Watanabe

A control system has been developed for a high-quality generating set (150-kW) equipped with a two-shaft gas turbine featuring a variable power turbine nozzle. Because this generating set satisfies stringent frequency stability requirements, it can be employed as the direct electric power source for computer centers without using constant-voltage, constant-frequency power supply systems. Conventional generating sets of this kind have normally been powered by single-shaft gas turbines, which have a larger output shaft inertia than the two-shaft version. Good frequency characteristics have also been realized with the two-shaft gas turbine, which provides superior quick start ability and lower fuel consumption under partial loads.

Author(s):  
H. Kumakura ◽  
T. Matsumura ◽  
E. Tsuruta ◽  
A. Watanabe

A control system has been developed for a high-quality generating set (150kW) equipped with a two-shaft gas turbine featuring a variable power turbine nozzle. Because this generating set satisfies stringent frequency stability requirements, it can be employed as the direct electric power source for computer centers without using constant-voltage, constant-frequency power supply systems. Conventional generating sets of this kind have normally been powered by single-shaft gas turbines which have a larger output shaft inertia than the two-shaft version. Good frequency characteristics have also been realized with the two-shaft gas turbine, which provides superior quick start ability and lower fuel consumption under partial loads.


Author(s):  
Keisuke Makino ◽  
Ken-Ichi Mizuno ◽  
Toru Shimamori

NGK Spark Plug Co., Ltd. has been developing various silicon nitride materials, and the technology for fabricating components for ceramic gas turbines (CGT) using theses materials. We are supplying silicon nitride material components for the project to develop 300 kW class CGT for co-generation in Japan. EC-152 was developed for components that require high strength at high temperature, such as turbine blades and turbine nozzles. In order to adapt the increasing of the turbine inlet temperature (TIT) up to 1,350 °C in accordance with the project goals, we developed two silicon nitride materials with further unproved properties: ST-1 and ST-2. ST-1 has a higher strength than EC-152 and is suitable for first stage turbine blades and power turbine blades. ST-2 has higher oxidation resistance than EC-152 and is suitable for power turbine nozzles. In this paper, we report on the properties of these materials, and present the results of evaluations of these materials when they are actually used for CGT components such as first stage turbine blades and power turbine nozzles.


1970 ◽  
Author(s):  
D. A. Prue ◽  
T. L. Soule

The next generation of free-turbine engines in the 2 to 5-lb/sec airflow class will undergo vast improvements in performance and efficiency. The improvements will be achieved concurrent with overall reductions in size and weight. Effort is required at optimization and miniaturization of the engine control system to keep pace with these improvements. This paper describes a conceptual design of an advanced engine control system for this class of engine. It provides gas generator and power turbine control with torque, temperature, load sharing and overspeed limiting functions. The control system was concepted to accommodate, with minimum hardware changes, such variants as regenerative cycle and/or variable power turbine geometry. In addition, considerations for closed and open loop modes of control and fluidic, electronic and hydromechanical technologies were studied to best meet a defined specification and a weighted set of evaluation criteria.


Author(s):  
Jie Gao ◽  
Feng Lin ◽  
Xiying Niu ◽  
Qun Zheng ◽  
Guoqiang Yue ◽  
...  

The marine gas turbine exhaust volute is an important component that connects a power turbine and an exhaust system, and it is of great importance to the overall performance of the gas turbine. Gases exhausted from the power turbine are expanded and deflected 90 degrees in the exhaust volute, and then discharge radially into the exhaust system. The flows in the power turbine and the nonaxisymmetric exhaust volute are closely coupled and inherently unsteady. The flow interactions between the power turbine and the exhaust volute have a significant influence on the shrouded rotor blade aerodynamic forces. However, the interactions have not been taken into account properly in current power turbine design approaches. The present study aims to investigate the flow interactions between the last stage of a shrouded power turbine and the nonaxisymmetric exhaust volute with struts. Special attention is given to the coupled aerodynamics and pressure response studies. This work was carried out using coupled computational fluid dynamics (CFD) simulations with the computational domain including a stator vane, 76 shrouded rotor blades, 9 struts and an exhaust volute. Three-dimensional (3D) unsteady and steady Reynolds-averaged Navier-Stokes (RANS) solutions in conjunction with a Spalart-Allmaras turbulence model are utilized to investigate the aerodynamic characteristics of shrouded rotors and an exhaust volute using a commercial CFD software ANSYS Fluent 14.0. The asymmetric flow fields are analyzed in detail; as are the unsteady pressures on the shrouded rotor blade. In addition, the unsteady total pressures at the volute outlet is also analyzed without consideration of the upstream turbine effects. Results show that the flows in the nonaxisymmetric exhaust volute are inherently unsteady; for the studied turbine-exhaust configuration the nonaxisymmetric back-pressure induced by the downstream volute leads to the local flow varying for each shrouded blade and low frequency fluctuations in the blade force. Detailed results from this investigation are presented and discussed in this paper.


Author(s):  
R. P. op het Veld ◽  
J. P. van Buijtenen

This paper investigates the layout and achievable efficiencies of rotating components of a Helium gas turbine. This is done by making a preliminary design of the compressor and turbine needed for the power conversion in a combined heat and power plant with a 40 MWth nuclear high temperature reactor as a heat source. State of the art efficiency values of air breathing gas turbines are used for the first calculations. The efficiency level is corrected by comparing various dimensionless data of the Helium turbomachine with an air gas turbine of similar dimensions. A single shaft configuration with a high speed axial turbine will give highest performance and simple construction. If a generator has to be driven at a conventional speed, a free power turbine configuration must be chosen. The choice of the configuration depends among others on the cost and availability of the asynchrone generator and frequency convertor.


Author(s):  
Deepak Thirumurthy ◽  
Jose Carlos Casado Coca ◽  
Kanishka Suraweera

Abstract For gas turbines with free power turbines, the capacity or flow parameter matching is of prime importance. Accurately matched capacity enables the gas turbine to run at its optimum conditions. This ensures maximum component efficiencies, and optimum shaft speeds within mechanical limits. This paper presents the challenges, uncertainties, and opportunities associated with an accurate matching of a generic two-shaft aeroderivative HP-LP gas generator with the free power turbine. Additionally, generic performance trends, uncertainty quantification, and results from the verification program are also discussed. These results are necessary to ensure that the final free power turbine capacity is within the allowable range and hence the product meets the performance guarantees. The sensitivity of free power turbine capacity to various design variables such as the vane throat area, vane trailing edge size, and manufacturing tolerance is presented. In addition, issues that may arise due to not meeting the target capacity are also discussed. To conclude, in addition to design, analysis, and statistical studies, a system-of-systems approach is mandatory to meet the allowed variation in the free power turbine capacity and hence the desired gas turbine performance.


Author(s):  
Alan Metzger

With the approach of the 1990 Clean Air Act compliance limits, the race is on to produce a functional, low-emission gas turbine. While most prototype Dry Low NOx (DLN) gas turbines are based on existing designs, the leap in technology required to meet NOx abatement levels is significant. To meet these goals, significant testing is required before low-emission turbines are ready for commercial production. This paper describes the test procedure that was used to verify control system and modulating valve technology for Turbo Power & Marine’s FT8-2™ Dry Low NOx prototype turbine. In particular, dynamic turbine simulation before the actual engine test will be discussed. The method and benefits of this test procedure will be presented.


Author(s):  
Majed Sammak ◽  
Egill Thorbergsson ◽  
Tomas Grönstedt ◽  
Magnus Genrup

The aim of this study was to compare single- and twin-shaft oxy-fuel gas turbines in a semiclosed oxy-fuel combustion combined cycle (SCOC–CC). This paper discussed the turbomachinery preliminary mean-line design of oxy-fuel compressor and turbine. The conceptual turbine design was performed using the axial through-flow code luax-t, developed at Lund University. A tool for conceptual design of axial compressors developed at Chalmers University was used for the design of the compressor. The modeled SCOC–CC gave a net electrical efficiency of 46% and a net power of 106 MW. The production of 95% pure oxygen and the compression of CO2 reduced the gross efficiency of the SCOC–CC by 10 and 2 percentage points, respectively. The designed oxy-fuel gas turbine had a power of 86 MW. The rotational speed of the single-shaft gas turbine was set to 5200 rpm. The designed turbine had four stages, while the compressor had 18 stages. The turbine exit Mach number was calculated to be 0.6 and the calculated value of AN2 was 40 · 106 rpm2m2. The total calculated cooling mass flow was 25% of the compressor mass flow, or 47 kg/s. The relative tip Mach number of the compressor at the first rotor stage was 1.15. The rotational speed of the twin-shaft gas generator was set to 7200 rpm, while that of the power turbine was set to 4800 rpm. A twin-shaft turbine was designed with five turbine stages to maintain the exit Mach number around 0.5. The twin-shaft turbine required a lower exit Mach number to maintain reasonable diffuser performance. The compressor turbine was designed with two stages while the power turbine had three stages. The study showed that a four-stage twin-shaft turbine produced a high exit Mach number. The calculated value of AN2 was 38 · 106 rpm2m2. The total calculated cooling mass flow was 23% of the compressor mass flow, or 44 kg/s. The compressor was designed with 14 stages. The preliminary design parameters of the turbine and compressor were within established industrial ranges. From the results of this study, it was concluded that both single- and twin-shaft oxy-fuel gas turbines have advantages. The choice of a twin-shaft gas turbine can be motivated by the smaller compressor size and the advantage of greater flexibility in operation, mainly in the off-design mode. However, the advantages of a twin-shaft design must be weighed against the inherent simplicity and low cost of the simple single-shaft design.


1990 ◽  
Vol 112 (2) ◽  
pp. 176-181 ◽  
Author(s):  
R. A. Sylvestre ◽  
R. J. Dupuis

The background and evolution of gas turbine fuel controls is examined in this paper from a Naval perspective. The initial application of aeroderivative gas turbines to Navy ships utilized the engine’s existing aircraft fuel controls, which were coupled to the ship’s hydropneumatic machinery control system. These engines were adapted to Naval requirements by including engine specific functions. The evolution of Naval gas turbine controllers first to analog electronic, and more recently, to distributed digital controls, has increased the system complexity and added a number of levels of machinery protection. The design of a specific electronic control module is used to illustrate the current state of the technology. The paper concludes with a discussion of the further need to address the issues of fuel handling, metering and control in Navy ships with particular emphasis on integration in the marine environment.


Author(s):  
Behnam Rezaei Zangmolk ◽  
Hiwa Khaledi

In this paper, development of a modular code for simulation of design and off-design performance of different gas turbines (with different shafts and technology) has been described. This interactive code will be used for different purposes in MPG Company. This turbomachinery and thermodynamic model is based on compressor and turbine maps and blade cooling has been considered with a cooling model. Component maps and effect of IGV have been developed from one of 1D, 2D or Q3d in-house codes. It is demonstrated that this model is accurate for prediction of gas turbine behavior at both design and off-design conditions. Effect of various control system — IGV constant, TIT constant and TET constant — is evaluated. These results show that IGV constant control system has the highest and TIT constant have the lowest efficiency for a simple cycle gas turbine. In contrast, the reverse is true in a combined cycle. Also the results show that the compressor is the most stable and away enough from surge line with IGV constant control system and has the highest efficiency.


Sign in / Sign up

Export Citation Format

Share Document