World’s Largest Single-Shaft Gas Turbine Installation

1970 ◽  
Author(s):  
R. C. Gaskins ◽  
J. M. Stevens

A unique 63,000-kw gas and steam turbine generator has been successfully integrated into a power plant to provide base load electric power and heat feedwater for existing boilers. The unit combined the world’s largest single-shaft gas turbine prototype with innovations of supercharging and a 20,000-kw steam turbine helper on the same shaft. The system, now a part of a Dow Chemical Power Plant in Freeport, Texas, had some minor problems mainly with the prototype turbine and has been in successful base load service since January, 1969.

Author(s):  
J. P. Zanyk

A review of the development and use of the gas turbine generator unit in The Dow Chemical Company for the cogeneration of steam and electric power energy for Dow’s major chemical complex. This review highlights the success and problems of Dow Chemical’s most recently constructed power plant at its Texas Division in Freeport, Texas. A review of Dow’s experience and developed technology to provide a reliable cogenerating plant.


Author(s):  
Pereddy Nageswara Reddy ◽  
J. S. Rao

Abstract A three stage combined power cycle with a Brayton cycle as the topping cycle, a Rankine cycle as the middling cycle and an Organic Rankine Cycle (ORC) as the bottoming cycle is proposed in the present investigation. A two-stage Gas Turbine Power Plant (GTPP) with inter-cooling, reheating and regeneration based on the Brayton cycle, a single-stage Steam Turbine Power Plant (STPP) based on the Rankine cycle, and a two-stage ORC power plant with reheating based on ORC with atmospheric air as the coolant is considered in the present study. This arrangement enables the proposed plant to utilize the waste heat to the maximum extent possible and convert it into electric power. As the plant can now operate at low sink temperatures depending on atmospheric air, the efficiency of the combined cycle power plant increases dramatically. Further, Steam Turbine Exhaust Pressure (STEP) is positive resulting in smaller size units and a lower installation cost. A simulation code is developed in MATLAB to investigate the performance of a three stage combined power cycle at different source and sink temperatures with varying pressure in heat recovery steam boiler and condenser-boiler. Performance results are plotted with Gas Turbine Inlet Temperature (GTIT) of 1200 to 1500 °C, Coolant Air Temperature (CAT) of −15 to +25 °C, and pressure ratio of GTPP as 6.25, 9.0 and 12.25 for different organic substances and NH3 as working fluids in the bottoming ORC. Simulation results show that the efficiency of the three stage combined power cycle will go up to 64 to 69% depending on the pressure ratio of GTPP, GTIT, and CAT. It is also observed that the variation in the efficiency of the three stage combined power cycle is small with respect to the type of working fluid used in the ORC. Among the organic working fluids R134a, R12, R22, and R123, R134a gives a higher combined cycle efficiency.


Author(s):  
H. A. Bazzini

Much of the steam-turbine based, power generating units all over the word are more than 30 years old now. Within a few years they will face the possibility of retirement from service and replacement. Nonetheless some of them are firm candidates for repowering, a technology able to improve plant efficiency, output and reliability at low costs. This paper summarizes a study performed to establish the feasibility to repower a 2 × 33 MW steam turbine power plant and the procedure followed until selection of the steam cycle more suitable to the project. The preferred solution is compared with direct replacement of the units by a new combined cycle. Various repowering options were reviewed to find “beat recovery” type repowering as the best solution. That well-known technology consists of replacing the steam generator by a gas turbine coupled to an HRSG, supplying steam to the existing steam turbine. Three “GT+HRSG+ST” arrangements were considered. Available gas turbine-generators — both industrial and aero-derivative type —, were surveyed for three power output ranges. Five “typical” gas turbine-generator classes were then selected. Steam flow raised at the HRSG, gross and net power generation, and heat exchanging surface area of the HRSG, were calculated for a broad range of usually applied, steam turbine throttle conditions. Both single pressure and double pressure steam cycles were considered, as well as supplemental fire and convenience of utilizing the existing feed water heaters. Balance of plant constraints were also reviewed. Estimates were developed for total investment, O&M costs, fuel expenses, and revenues. Results are shown through various graphics and tables. The route leading to the preferred solution is explained and a sensitivity analysis added to validate the selection. The preferred solution, consisting in a Class 130 gas turbine in arrangement 1–1–2, a dual-pressure HRSG and a steam cycle without feed-water heaters, win allow delivering 200 MW to the grid, with a heat rate of 7423 kJ/kW-hr. Investment was valued at $MM77.0, with an IRR of 15.3%. Those figures compare well with the option of installing a new GTCC unit: with a better heat rate but an investment valued at $MM97.5, its IRR will only be 12.4%.


2013 ◽  
Vol 658 ◽  
pp. 430-436 ◽  
Author(s):  
Mohamed A. Elhaj ◽  
Moustfa M. Mahgub ◽  
Kassim K. Matrawy

The aim of the present study is to utilize the excess energy of combined cycle power plant (CCPP) in desalination unit in cases of low electrical demand loading conditions. The main components of proposed (CCPP) included the gas turbine and steam turbine units. Gas turbine produces the major part of the developed power, while the steam turbine produces the remaining one in case of peak loading conditions. For the case of base load, the excess energy of steam turbine is used in desalination unit.


Author(s):  
Wancai Liu ◽  
Hui Zhang

Gas turbine is widely applied in power-generation field, especially combined gas-steam cycle. In this paper, the new scheme of steam turbine driving compressor is investigated aiming at the gas-steam combined cycle power plant. Under calculating the thermodynamic process, the new scheme is compared with the scheme of conventional gas-steam combined cycle, pointing its main merits and shortcomings. At the same time, two improved schemes of steam turbine driving compressor are discussed.


Author(s):  
J R Bolter

Sir Charles Parsons died some three years after the author was born. In this paper the author looks back at the pioneering work of Parsons in the field of power generation. It shows how he was able to increase output of the steam turbine generator from 7.5 kW in 1884 to 50000 kW in 1930 while increasing efficiency from 1.6 to 36 per cent, and relates these achievements to the current state of the art. Blading design, rotor construction and other aspects of turbine engineering are considered. The conclusion is that Parsons and his associates charted the course which manufacturers and utilities throughout the world have continued to follow, although increasingly sophisticated design and analytical methods have succeeded the intuitive approach of Parsons. His constant search for improved efficiency was and is highly relevant to today's concern for the environment. Finally, although it did not become a practical proposition in his lifetime, the paper reviews Parsons' vision of, and continuing interest in, the gas turbine, first mentioned in his 1884 patents.


1980 ◽  
Author(s):  
J. Jermanok ◽  
R. E. Keith ◽  
E. F. Backhaus

A new 37-MW, single-shaft gas turbine power plant has been designed for electric power generation, for use in either simple-cycle or combined-cycle applications. This paper describes the design features, instrumentation, installation, test, and initial operation.


2010 ◽  
Vol 132 (12) ◽  
pp. 57-57
Author(s):  
Lee S. Langston

This article presents an overview of gas turbine combined cycle (CCGT) power plants. Modern CCGT power plants are producing electric power as high as half a gigawatt with thermal efficiencies approaching the 60% mark. In a CCGT power plant, the gas turbine is the key player, driving an electrical generator. Heat from the hot gas turbine exhaust is recovered in a heat recovery steam generator, to generate steam, which drives a steam turbine to generate more electrical power. Thus, it is a combined power plant burning one unit of fuel to supply two sources of electrical power. Most of these CCGT plants burn natural gas, which has the lowest carbon content of any other hydrocarbon fuel. Their near 60% thermal efficiencies lower fuel costs by almost half compared to other gas-fired power plants. Their installed capital cost is the lowest in the electric power industry. Moreover, environmental permits, necessary for new plant construction, are much easier to obtain for CCGT power plants.


Author(s):  
David J. Olsheski ◽  
William W. Schulke

Traditionally commercial marine propulsion needs have been met with direct drive reciprocating prime movers. In order to increase efficiency, simplify installation and maintenance accessibility, and increase cargo / passenger capacity; indirect electric drive gas and steam turbine combined cycle prime movers are being introduced to marine propulsion systems. One such application is the Royal Caribbean Cruise Line (RCCL) Millennium Class ship. This commercial vessel has two aero-derivative gas turbine generator sets with a single waste heat recovery steam turbine generator set. Each is controlled by independent microprocessor based digital control systems. This paper addresses only the gas turbine control system architecture and the unique safety and dynamic features that are integrated into the control system for this application.