scholarly journals Repowering Fossil Steam Power Plants With Combustion Turbine-Based Technologies

Author(s):  
Stanley Pace ◽  
Arden Walters

Increased competition fostered by changes in legislation governing power generation entities has engendered a need to closely assess the economics of operating older-electric generating units. Decisions must be made as to whether these units should be retired and replaced with new, greenfield generation capacity, whether capacity should be purchased from other generation companies, or whether such units should be repowered in some way. The repowering alternative has merit when economic factors and environmental considerations show it to project the least cost of electricity over other choices. The chief advantages of repowering, include use of existing real estate and infrastructure, existing transmission facilities and staffing. Since the repowered plant usually emits less stack gas pollutants per unit of energy generated then the original plant, environmental benefits can also accrue. Various types of gas turbine based repowering options for steam electric plants are presented. All the approaches discussed involve the addition of gas turbines to the cycle and the consequent benefit of some form of combined cycle operation. This option includes boiler retirement (and replacement with combined cycle), hot or warm windbox repowering (the boiler is retained and a gas turbine topping cycle is added), feedwater heating repowering (the gas turbine exhaust heats feedwater), and site repowering (only the site infrastructure is re-used as the site for a combined cycle). Business considerations are discussed in terms of their impact on the decision to repower and technology selection. An example involving feedwater heater repowering is used to illustrate the interaction between the business and technical aspects of repowering.

Author(s):  
Leonid Moroz ◽  
Petr Pagur ◽  
Oleksii Rudenko ◽  
Maksym Burlaka ◽  
Clement Joly

Bottoming cycles are drawing a real interest in a world where resources are becoming scarcer and the environmental footprint of power plants is becoming more controlled. Reduction of flue gas temperature, power generation boost without burning more fuel and even production of heat for cogeneration applications are very attractive and it becomes necessary to quantify how much can really be extracted from a simple cycle to be converted to a combined configuration. As supercritical CO2 is becoming an emerging working fluid [2, 3, 5, 7 and 8] due not only to the fact that turbomachines are being designed significantly more compact, but also because of the fluid’s high thermal efficiency in cycles, it raises an increased interest in its various applications. Evaluating the option of combined gas and supercritical CO2 cycles for different gas turbine sizes, gas turbine exhaust gas temperatures and configurations of bottoming cycle type becomes an essential step toward creating guidelines for the question, “how much more can I get with what I have?”. Using conceptual design tools for the cycle system generates fast and reliable results to draw this type of conclusion. This paper presents both the qualitative and quantitative advantages of combined cycles for scalability using machines ranging from small to several hundred MW gas turbines to determine which configurations of S-CO2 bottoming cycles are best for pure electricity production.


Author(s):  
Jaya Ganjikunta

Market demands such as generating power at lower cost, increasing reliability, providing fuel flexibility, increasing efficiency and reducing emissions have renewed the interest in Integrated Gasification Combined Cycle (IGCC) plants in the Indian refinery segment. This technology typically uses coal or petroleum coke (petcoke) gasification and gas turbine based combined cycle systems as it offers potential advantages in reducing emissions and producing low cost electricity. Gasification of coal typically produces syngas which is a mixture of Hydrogen (H) and Carbon Monoxide (CO). Present state of gas turbine technology facilitates burning of low calorific fuels such as syngas and gas turbine is the heart of power block in IGCC. Selecting a suitable gas turbine for syngas fired power plant application and optimization in integration can offer the purchaser savings in initial cost by avoiding oversizing as well as reduction in operating cost through better efficiency. This paper discusses the following aspects of syngas turbine IGCC power plant: • Considerations in design and engineering approach • Review of technologies in syngas fired gas turbines • Design differences of syngas turbines with respect to natural gas fired turbines • Gas turbine integration with gasifier, associated syngas system design and materials • Syngas safety, HAZOP and Hazardous area classification • Retrofitting of existing gas turbines suitable for syngas firing • Project execution and coordination at various phases of a project This paper is based on the experience gained in the recently executed syngas fired gas turbine based captive power plant and IGCC plant. This experience would be useful for gas turbine technology selection, integration of gas turbine in to IGCC, estimating engineering efforts, cost savings, cycle time reduction, retrofits and lowering future syngas based power plant project risks.


Author(s):  
R. W. Jones ◽  
A. C. Shoults

This paper presents details of three large gas turbine installations in the Freeport, Texas, power plants of the Dow Chemical Company. The general plant layout, integration of useful outputs, economic factors leading to the selection of these units, and experiences during startup and operation will be reviewed. All three units operate with supercharging fan, evaporative cooler, and static excitation. Two of the installations are nearly identical 32,000-kw gas turbines operating in a combined cycle with a supplementary fired 1,500,000-lb/hr boiler and a 50,000-kw noncondensing steam turbine. The other installation is a 43,000-kw gas turbine and a 20,000-kw starter-helper steam turbine on the same shaft. The gas turbine exhaust is used to supply heated feedwater for four existing boilers.


Author(s):  
Douglas C. Hofer ◽  
S. Can Gulen

A significant portion of the new electrical generating capacity installed in the past decade has employed heavy-duty gas turbines operating in a combined cycle configuration with a steam turbine bottoming cycle. In these power plants approximately 1/3 of the power is generated by the bottoming cycle. To ensure that the highest possible combined cycle efficiency is realized it is important to optimize the bottoming cycle efficiency and doing so requires a solid understanding of the efficiency entitlement. This paper describes a new technique for calculating the theoretical efficiency entitlement for a bottoming cycle that corresponds to the maximum possible bottoming cycle work and maximized combined cycle work and efficiency. This new method accounts for the decrease in ideal efficiency as the gas turbine exhaust is cooled as it transfers heat energy to the working fluid in the bottoming cycle. The new definition is compared to conventional definitions, including that of Carnot and an Exergy based second law efficiency, and shown to provide a simple and accurate analytical expression for the entitlement efficiency in a bottoming cycle. For representative cycle conditions, the entitlement efficiency for the bottoming cycle is calculated to be ∼45% compared to the Carnot efficiency for the same conditions of ∼67%. Although the new method is applicable to any power cycle obtaining its heat input from the exhaust stream of a topping cycle, special attention is given to the steam bottoming cycle traditionally used in modern gas turbine combined cycle power plants. Comparisons are made between the ideal bottoming cycle and variants of a steam cycle including a single pressure non-reheat and a three pressure reheat cycle. These comparisons explore the unavoidable loss in efficiency associated with constant temperature heat addition that occurs in the steam cycle.


Author(s):  
Akber Pasha

In recent years the combined cycle has become a very attractive power plant arrangement because of its high cycle efficiency, short order-to-on-line time and flexibility in the sizing when compared to conventional steam power plants. However, optimization of the cycle and selection of combined cycle equipment has become more complex because the three major components, Gas Turbine, Heat Recovery Steam Generator and Steam Turbine, are often designed and built by different manufacturers. Heat Recovery Steam Generators are classified into two major categories — 1) Natural Circulation and 2) Forced Circulation. Both circulation designs have certain advantages, disadvantages and limitations. This paper analyzes various factors including; availability, start-up, gas turbine exhaust conditions, reliability, space requirements, etc., which are affected by the type of circulation and which in turn affect the design, price and performance of the Heat Recovery Steam Generator. Modern trends around the world are discussed and conclusions are drawn as to the best type of circulation for a Heat Recovery Steam Generator for combined cycle application.


2010 ◽  
Vol 132 (12) ◽  
pp. 57-57
Author(s):  
Lee S. Langston

This article presents an overview of gas turbine combined cycle (CCGT) power plants. Modern CCGT power plants are producing electric power as high as half a gigawatt with thermal efficiencies approaching the 60% mark. In a CCGT power plant, the gas turbine is the key player, driving an electrical generator. Heat from the hot gas turbine exhaust is recovered in a heat recovery steam generator, to generate steam, which drives a steam turbine to generate more electrical power. Thus, it is a combined power plant burning one unit of fuel to supply two sources of electrical power. Most of these CCGT plants burn natural gas, which has the lowest carbon content of any other hydrocarbon fuel. Their near 60% thermal efficiencies lower fuel costs by almost half compared to other gas-fired power plants. Their installed capital cost is the lowest in the electric power industry. Moreover, environmental permits, necessary for new plant construction, are much easier to obtain for CCGT power plants.


Author(s):  
Isaac Shnaid

The modem combined cycle power plants achieved thermal efficiency of 50–55% by applying bottoming multistage Rankine steam cycle. At the same time, the Brayton cycle is an attractive option for a bottoming cycle engine. In the author’s US Patent No. 5,442,904 is described a combined cycle system with a simple cycle gas turbine, the bottoming air turbine Brayton cycle, and the reverse Brayton cycle. In this system, air turbine Brayton cycle produces mechanic power using exergy of gas turbine exhaust gases, while the reverse Brayton cycle refrigerates gas turbine inlet air. Using this system, supercharging of gas turbine compressor becomes possible. In the paper, thermodynamic optimization of the system is done, and the system techno-economic characteristics are evaluated.


Author(s):  
Onkar Singh ◽  
R. Yadav

Combined cycle based power plants and their development and application for energy efficient base load power generation necessitates enforced cooling to maintain the topping cycle gas turbine blade temperature at permissible levels, attributed to the increased turbine inlet temperature and compressor pressure ratio, for the improved performance and reliability of combined cycle. The mathematical model based on expansion path inside gas turbine considering dilution of mainstream and aerodynamic mixing losses for a range of cooling medium has been developed based on internal, film, transpiration cooling technologies and a combination of these. It is found that the appreciation of a cycle configuration as well as the optimum pressure ratio and peak temperature vary significantly with types of cooling technology adopted. Steam cooling for rotor appears to be a very potential cooling medium, when employed with an appropriate cooling technology. This paper deals with the thermodynamic analysis of turbine cooling using, different means of cooling i.e. air, water and steam.


Author(s):  
Lothar Bachmann ◽  
W. Fred Koch

The purpose of this paper is to update the industry on the evolutionary steps that have been taken to address higher requirements imposed on the new generation combined cycle gas turbine exhaust ducting expansion joints, diverter and damper systems. Since the more challenging applications are in the larger systems, we shall concentrate on sizes from nine (9) square meters up to forty (40) square meters in ducting cross sections. (Reference: General Electric Frame 5 through Frame 9 sizes.) Severe problems encountered in gas turbine applications for the subject equipment are mostly traceable to stress buckling caused by differential expansion of components, improper insulation, unsuitable or incompatible mechanical design of features, components or materials, or poor workmanship. Conventional power plant expansion joints or dampers are designed for entirely different operating conditions and should not be applied in gas turbine applications. The sharp transients during gas turbine start-up as well as the very high temperature and high mass-flow operation conditions require specific designs for gas turbine application.


Author(s):  
F. L. Robson ◽  
D. J. Seery

The Department of Energy’s Federal Energy Technology Center (FETC) is sponsoring the Combustion 2000 Program aimed at introducing clean and more efficient advanced technology coal-based power systems in the early 21st century. As part of this program, the United Technologies Research Center has assembled a seven member team to identify and develop the technology for a High Performance Power Systems (HIPPS) that will provide in the near term, 47% efficiency (HHV), and meet emission goals only one-tenth of current New Source Performance Standards for coal-fired power plants. In addition, the team is identifying advanced technologies that could result in HIPPS with efficiencies approaching 55% (HHV). The HIPPS is a combined cycle that uses a coal-fired High Temperature Advanced Furnace (HITAF) to preheat compressor discharge air in both convective and radiant heaters. The heated air is then sent to the gas turbine where additional fuel, either natural gas or distillate, is burned to raise the temperature to the levels of modern gas turbines. Steam is raised in the HITAF and in a Heat Recovery Steam Generator for the steam bottoming cycle. With state-of-the-art frame type gas turbines, the efficiency goal of 47% is met in a system with more than two-thirds of the heat input furnished by coal. By using advanced aeroderivative engine technology, HIPPS in combined-cycle and Humid Air Turbine (HAT) cycle configurations could result in efficiencies of over 50% and could approach 55%. The following paper contains descriptions of the HIPPS concept including the HITAF and heat exchangers, and of the various gas turbine configurations. Projections of HIPPS performance, emissions including significant reduction in greenhouse gases are given. Application of HIPPS to repowering is discussed.