Application of a Multi-Block CFD Code to Investigate the Impact of Geometry Modeling on Centrifugal Compressor Flow Field Predictions

1996 ◽  
Author(s):  
Michael D. Hathaway ◽  
Jerry R. Wood

CFD codes capable of utilizing multi-block grids provide capability to analyze the complete geometry of centrifugal compressors including, among others, multiple splitter rows, tip clearance, blunt trailing edges, fillets, and slots between moving and stationary surfaces. Attendant with this increased capability is potentially increased grid setup time and more computational overhead — CPU time and memory requirements — with the resultant increase in “wall clock” time to obtain a solution. If the increase in “difficulty” of obtaining a solution significantly improves the solution from that obtained by modeling the features of the tip clearance flow or the typical bluntness of a centrifugal compressor’s trailing edge, then the additional burden is worthwhile. However, if the additional information obtained is of marginal use then modeling of certain features of the geometry may provide reasonable solutions for designers to make comparative choices when pursuing a new design. In this spirit a sequence of grids were generated to study the relative importance of modeling versus detailed gridding of the tip gap and blunt trailing edge regions of the NASA large low speed centrifugal compressor for which there is considerable detailed internal laser anemometry data available for comparison. The results indicate: 1) There is no significant difference in predicted tip clearance mass flow rate whether the tip gap is gridded or modeled. 2) Gridding rather than modeling the trailing edge results in better predictions of some flow details downstream of the impeller, but otherwise appears to offer no great benefits. 3) The pitchwise variation of absolute flow angle decreases rapidly up to 8% impeller radius ratio and much more slowly thereafter. Although some improvements in prediction of flow field details are realized as a result of analyzing the actual geometry there is no clear consensus that any of the grids investigated produced superior results in every case when compared to the measurements. However, if a multi-block code is available it should be used as it has the propensity for enabling better predictions than a single block code which requires modeling of certain geometry features. If a single block code must be used some guidance is offered for modeling those geometry features which can’t be directly gridded.

1997 ◽  
Vol 119 (4) ◽  
pp. 820-830
Author(s):  
M. D. Hathaway ◽  
J. R. Wood

CFD codes capable of utilizing multi-block grids provide the capability to analyze the complete geometry of centrifugal compressors including, among others, multiple splitter rows, tip clearance, blunt trailing edges, fillets, and slots between moving and stationary surfaces. Attendant with this increased capability is potentially increased grid setup time and more computational overhead—CPU time and memory requirements—with the resultant increase in “wall clock” time to obtain a solution. If the increase in “difficulty” of obtaining a solution significantly improves the solution from that obtained by modeling the features of the tip clearance flow or the typical bluntness of a centrifugal compressor’s trailing edge, then the additional burden is worthwhile. However, if the additional information obtained is of marginal use, then modeling of certain features of the geometry may provide reasonable solutions for designers to make comparative choices when pursuing a new design. In this spirit a sequence of grids were generated to study the relative importance of modeling versus detailed gridding of the tip gap and blunt trailing edge regions of the NASA large low-speed centrifugal compressor for which there is considerable detailed internal laser anemometry data available for comparison. The results indicate: (1) There is no significant difference in predicted tip clearance mass flow rate whether the tip gap is gridded or modeled. (2) Gridding rather than modeling the trailing edge results in better predictions of some flow details downstream of the impeller, but otherwise appears to offer no great benefits. (3) The pitchwise variation of absolute flow angle decreases rapidly up to 8 percent impeller radius ratio and much more slowly thereafter. Although some improvements in prediction of flow field details are realized as a result of analyzing the actual geometry there is no clear consensus that any of the grids investigated produced superior results in every case when compared to the measurements. However, if a multi-block code is available, it should be used, as it has the propensity for enabling better predictions than a single block code, which requires modeling of certain geometry features. If a single block code must be used, some guidance is offered for modeling those geometry features that cannot be directly gridded.


2012 ◽  
Vol 2012 ◽  
pp. 1-11 ◽  
Author(s):  
Yohan Jung ◽  
Minsuk Choi ◽  
Seonghwan Oh ◽  
Jehyun Baek

This paper presents a numerical investigation of the effects of a nonuniform tip clearance profile on the performance and flow field in a centrifugal compressor with a vaneless diffuser. This study focuses in particular on the magnitude and location of the wake. Six impellers with different tip clearance profiles were tested in the flow simulations. The accuracy of the numerical simulations was assessed by comparing the experimental data with the computational results for a system characterized by the original tip clearance. Although the performance improved for low tip clearances, a low tip clearance at the trailing edge improved the compressor performance more significantly than a low tip clearance at the leading edge. The flow field calculated for a system characterized by a low tip clearance at the trailing edge produced a more uniform velocity distribution both in the circumferential and in the axial directions at the impeller exit because the wake magnitude was reduced. As a consequence, this impeller provided a better potential for diffusion processes inside a vaneless diffuser.


2015 ◽  
Vol 137 (6) ◽  
Author(s):  
Andreas Krug ◽  
Peter Busse ◽  
Konrad Vogeler

An important aspect of the aerodynamic flow field in the tip region of axial compressor rotors is the unsteady interaction between the tip clearance vortex (TCV) and the incoming stator wakes. In order to gain an improved understanding of the mechanics involved, systematic studies need to be performed. As a first step toward the characterization of the dynamic effects caused by the relative movement of the blade rows, the impact of a stationary wake-induced inlet disturbance on a linear compressor cascade with tip clearance will be analyzed. The wakes were generated by a fixed grid of cylindrical bars with variable pitch being placed at discrete pitchwise positions. This paper focuses on experimental studies conducted at the newly designed low-speed cascade wind tunnel in Dresden. The general tunnel configuration and details on the specific cascade setup will be presented. Steady state flow field measurements were carried out using five-hole probe traverses up- and downstream of the cascade and accompanied by static wall pressure readings. 2D-particle image velocimetry (PIV) measurements complemented these results by visualizing the blade-to-blade flow field. Hence, the structure of the evolving secondary flow system is evaluated and compared for all tested configurations.


2021 ◽  
pp. 1-33
Author(s):  
Eric DeShong ◽  
Shawn Siroka ◽  
Reid A. Berdanier ◽  
Karen A. Thole

Abstract The clearance that exists between the casing and turbine blade tips is one of the key drivers of efficiency in gas turbine engines. For this reason, engine manufacturers utilize precise manufacturing techniques and may employ clearance control systems to minimize tip clearances to reduce associated losses. Despite these efforts, turbines typically exhibit some nominal casing ovality or rotor-casing eccentricity, and changes to blade tip clearance during operation commonly occur due to thermal and mechanical stresses. The present study investigates non-axisymmetric tip clearance effects by creating a rotor-casing eccentricity in a one-stage axial test turbine operating in a continuous-duration mode at engine relevant conditions with engine representative hardware. A magnetic levitation bearing system was leveraged to move the turbine shaft to vary the rotor-casing eccentricity without test section disassembly. The results of this study indicate that rotor-casing eccentricity does not affect overall turbine efficiency over the range that was tested, but does locally influence efficiency and the rotor exit flow field. Comparisons of flow angle and secondary flow kinetic energy agreed with previous studies and existing analytical methods, respectively. Collectively, these results indicate that tip clearance can be studied locally on an eccentric rotor.


Author(s):  
Masanao Kaneko ◽  
Hoshio Tsujita

A transonic centrifugal compressor impeller is generally composed of the main and the splitter blades which are different in chord length. As a result, the tip leakage flows from the main and the splitter blades interact with each other and then complicate the flow field in the compressor. In this study, in order to clarify the individual influences of these leakage flows on the flow field in the transonic centrifugal compressor stage at near-choke to near-stall condition, the flows in the compressor at four conditions prescribed by the presence and the absence of the tip clearances were analyzed numerically. The computed results clarified the following noticeable phenomena. The tip clearance of the main blade induces the tip leakage vortex from the leading edge of the main blade. This vortex decreases the blade loading of the main blade to the negative value by the increase of the flow acceleration along the suction surface of the splitter blade, and consequently induces the tip leakage vortex caused by the negative blade loading of the main blade at any operating points. These phenomena decline the impeller efficiency. On the other hand, the tip clearance of the splitter blade decreases the afore mentioned acceleration by the formation of the tip leakage vortex from the leading edge of the splitter blade and the decrease of the incidence angle for the splitter blade caused by the suction of the flow into the tip clearance. These phenomena reduce the loss generated by the negative blade loading of the main blade and consequently reduce the decline of the impeller efficiency. Moreover, the tip clearances enlarge the flow separation around the diffuser inlet and then decline the diffuser performance independently of the operating points.


Author(s):  
Wenrui Bao ◽  
Ce Yang ◽  
Li Fu ◽  
Changmao Yang ◽  
Lucheng Ji

Abstract An asymmetric structure of volute in a supercritical carbon dioxide centrifugal compressor induces a non-uniform circumferential distribution of the upstream flow field, which inevitably affects the formation of a two-phase region of carbon dioxide in an impeller. In this work, unsteady simulations for centrifugal compressors were conducted. First, the influence of low static strip induced by low static pressure near volute tongue on the impeller flow field was presented. Then, the non-uniform flow field distribution in the impeller passages and flow characteristics of the passages at the impeller inlet were obtained. Finally, the two-phase regions in the impeller were presented. The results demonstrate that for a centrifugal compressor with volute, the two-phase region appears not only on the suction surface of the leading edge of the blade, but also in some impeller passages, on the pressure surface of the blade near the leading edge, and in the leading edge and mid-chord of tip clearance, under the design conditions. The low static pressure strip induced by the volute leads to a high-speed region in the impeller passages where the temperature and pressure of supercritical carbon dioxide fall below the critical point and carbon dioxide enters the two-phase region. Meanwhile, the static pressure on the blade surface is distorted under the influence of a high-speed region in the passages, resulting in the formation of a two-phase region at the tip clearance. The flow distortion of passages at the impeller inlet results in the appearance of two-phase regions on the both sides of leading edge of the blade. The dryness on the suction side of the blade leading edge and the leading edge of the tip clearance is lower, which indicated that the proportion of liquid-phase carbon dioxide is higher in these two-phase regions.


Author(s):  
K. Funazaki ◽  
C. F. F. Favaretto ◽  
T. Tanuma

In the present paper steady three-dimensional numerical calculations were performed in order to investigate the effects of flow injection from the outer casing upon turbine nozzle vane flow field. Several test cases were analyzed by applying different nozzle vane configurations such as the blade lean, injection slot width and distance from the leading edge. Numerical simulations were conducted considering the no injection case, 5% and 10% main stream flow injection from the outer casing. The impact of the flow injection design variables and the blade lean angle on the aerodynamic loss in terms of the energy loss coefficient and the outlet flow angle were analyzed through a parametric study.


2012 ◽  
Vol 135 (1) ◽  
Author(s):  
Robert Kunte ◽  
Philipp Schwarz ◽  
Benjamin Wilkosz ◽  
Peter Jeschke ◽  
Caitlin Smythe

The subject of this paper is the experimental and numerical investigation of a state-of-the-art high pressure centrifugal compressor stage with pipe diffuser for a jet engine application. This study shows the impact of impeller tip clearance- and bleed-variation on the centrifugal stage. The purpose of this paper is threefold. In the first place, it investigates the effects on the stage performance. Secondly, it seeks to explain local flow-phenomena, especially in the diffuser. Finally, it shows that steady CFD simulations are capable of predicting these phenomena. Experimental data were gathered using conventional pitot and three-hole-probes as well as particle-image-velocimetry. Numerical simulations with the CFD solver TRACE were conducted to get fundamental insight into the flow. Thus, this study contributes greatly towards understanding the principle of the flow phenomena in the pipe diffuser of a centrifugal compressor.


Author(s):  
Peter Busse ◽  
Andreas Krug ◽  
Konrad Vogeler

An important aspect of the aerodynamic flow field in the tip region of axial compressor rotors is the unsteady interaction between the tip clearance vortex and the incoming stator wakes. In order to gain an improved understanding of the mechanics involved, systematic studies need to be performed. As a first step towards the characterisation of the dynamic effects caused by the relative movement of the blade rows, the impact of a stationary wake-induced inlet disturbance on a linear compressor cascade with tip clearance will be analyzed. The wakes were generated by a fixed grid of cylindrical bars with variable pitch being placed at discrete pitchwise positions. Part II of this two-part paper focuses on the numerical studies conducted with the scientific flow solver TRACE. Selected measurements, which are discussed in detail in the first part of this paper, are compared with steady state RANS simulation data to determine the validity of the computational model. For this purpose, the flow field obtained in the passage (PIV), at the cascade exit (five-hole probes) and the endwall pressure distributions were used. The presented numerical results show potentials and limitations of the steady state CFD for the prediction of the investigated flow phenomena. The computations provide the initial conditions for future unsteady calculations, and enable a separate depiction of potential effects of steady and unsteady wake-tip clearance vortex interaction.


Author(s):  
Sabri Deniz ◽  
Edward M. Greitzer ◽  
Nicholas A. Cumpsty

This is Part 2 of an examination of influence of inlet flow conditions on the performance and operating range of centrifugal compressor vaned diffusers. The paper describes tests of straight-channel type diffuser, sometimes called a wedge-vane diffuser, and compares the results with those from the discrete-passage diffusers described in Part 1. Effects of diffuser inlet Mach number, flow angle, blockage, and axial flow non-uniformity on diffuser pressure recovery and operating range are addressed. The straight-channel diffuser investigated has 30 vanes and was designed for the same aerodynamic duty as the discrete-passage diffuser described in Part 1. The ranges of the overall pressure recovery coefficients were 0.65–0.78 for the straight-channel diffuser and 0.60–0.70 for the discrete-passage diffuser; the pressure recovery of the straight-channel diffuser was roughly 10% higher than that of the discrete-passage diffuser. Both types of the diffusers showed similar behavior regarding the dependence on diffuser inlet flow angle and the insensitivity of the performance to inlet flow field axial distortion and Mach number. The operating range of the straight-channel diffuser, as for the discrete-passage diffusers was limited by the onset of rotating stall at a fixed momentum-averaged flow angle into the diffuser, which was for the straight-channel diffuser, αcrit = 70° ±0.5°. The background, nomenclature and description of the facility and method are all given in Part 1.