In-Situ Preparation of Catalytic Diffusion Layers and Its Application in Direct Liquid Fuel Cells

Author(s):  
Nie Luo ◽  
Xiaoling Yang ◽  
Kyu-Jung Kim ◽  
James F. Stubbins ◽  
George H. Miley ◽  
...  

Direct liquid fuel cells, such as the direct methanol fuel cell (DMFC) and borohydride fuel cell, may experience severe electrochemical corrosion problems due to the presence of conducting liquid fuels. This type of fuel cells has catalytic electrodes that are permeable to the liquid fuels. This permeability to liquids or solutions then opens up a possibility to the electrochemical improvement of catalytic electrodes once excessive corrosion has occurred. The in-situ electro-deposition or electroplating of the catalytic diffusion electrode is developed to first improve the performance and secondly mitigate the corrosion problem. The experimental details of such a technique are described in this paper. Direct liquid fuel cells thus treated typically have power density up to 40% higher, compared to fuel cells whose catalysts are prepared the traditional way. It is well known that power density is one of the enabling factors for portable power sources, for which the typical direct liquid fuel cells are designed. Therefore, the in-situ electroplating technique is expected to play an important role in the commercialization of fuel cell technology.

Author(s):  
Fikile R. Brushett ◽  
Adam S. Hollinger ◽  
Larry J. Markoski ◽  
Paul J. A. Kenis

A continuously growing need for high energy density miniaturized power sources for portable electronic applications has spurred the development of a variety of microscale fuel cells. For portable applications, membrane-based fuel cells using small organic fuels (i.e., methanol, formic acid) are among the most promising configurations as they benefit from the high energy density and easy storage of the liquid fuels. Unfortunately, the performance of these fuel cells is often hindered by membrane-related issues such as water management (i.e., electrode dry-out / flooding) and fuel crossover. Furthermore, high costs of, for example, catalysts and membranes as well as durability concerns still hinder commercialization efforts. To address these challenges we have developed membraneless laminar flow-based fuel cells (LFFCs), which exploit microscale transport phenomena (laminar flow) to compartmentalize streams within a single microchannel. The properties of various fuel and media flexible LFFCs will be presented and novel strategies for improving fuel utilization and power density will be discussed. Furthermore, the performance of a scaled-out 14-channel LFFC prototype is presented. We have also developed a microfluidic fuel cell as a powerful analytical platform to investigate and optimize the complex processes that govern the performance of catalysts and electrodes in an operating fuel cell. This platform bridges the gap between a conventional 3-electrode electrochemical cell and a fuel cell, as it allows for standard electrochemical analysis (e.g., CV, CA, EIS) as well as fuel cell analysis (e.g., IV curves).


2015 ◽  
Vol 12 (6) ◽  
pp. 591-606 ◽  
Author(s):  
Venkateswarlu Velisala ◽  
G. Naga Srinivasulu ◽  
B. Srinivasa Reddy ◽  
K. Venkata Koteswara Rao

Fuel cells technologies are the most promising green energy technologies for diverse applications. One of the fastest growing areas is the portable electronic applications where the power range is the order of 1–100 W. For most of the portable electronic devices, rechargeable battery is the major energy source. Due to limitations like limited capacity, requirement of external power for recharge have led many researchers to look for alternative power sources to power portable electronic devices. The high energy density of fuel cells makes them very attractive alternative to batteries for portable power applications. There are a variety of fuel cell technologies being considered to replace batteries in portable electronic equipment. Direct Liquid Fuel Cells (DLFCs) have attracted much attention due to their potential applications as a power source for portable electronic devices. The advantages of DLFCs over hydrogen fed PEM fuel cells include a higher theoretical energy density and efficiency, a more convenient handling of the streams, and enhanced safety. Unlike batteries, fuel cells need not be recharged, merely refueled. This paper provides an overview on challenges of DLFCs (Direct Liquid Fuel Cells), like fuel crossover, cost, durability, water management, weight and size along with approaches being investigated to solve these challenges. Portable Fuel Cell Commercialization Targets for future and producers of portable fuel cells across the globe are also discussed in this paper.


2018 ◽  
Vol MA2018-01 (32) ◽  
pp. 1992-1992
Author(s):  
Mohamed El Hannach ◽  
Ka Hung Wong ◽  
Yadvinder Singh ◽  
Narinder Singh Khattra ◽  
Erik Kjeang

The hydrogen fuel cell is a promising technology that supports the development of sustainable energy systems and zero emission vehicles. One of the key technical challenges for the use of fuel cells in the transportation sector is the high durability requirements 1–3. One of the key components that control the overall life time of a hydrogen fuel cell is the ionomer membrane that conducts the protons and allows the separation between the anode and the cathode. During fuel cell operation, the membrane is subjected to two categories of degradation: mechanical and chemical. These degradations lead to reduction in the performance, crossover of reactants between anode and cathode and ultimately total failure of the fuel cell. The mechanical degradation occurs when the membrane swells and shrinks under the variation of the local hydration level. This leads to fatigue of the ionomer structure and ultimately irreversible damage. However, under pure mechanical degradation the damage takes a very long time to occur 4,5. Sadeghi et al. 5 observed failure of the membrane after 20,000 of accelerated mechanical stress testing. This translates into a longer lifetime in comparison to what is observed in field operation 6. The chemical degradation on the other hand is caused by the presence of harmful chemicals such as OH radicals that attack the side chains and the main chains of the ionomer 7,8. Such attacks weaken the structural integrity of the membrane and make it prone to severe mechanical damage. Hence understanding the effect of combining both categories of membrane degradation is the key to accurate prediction of the time to failure of the fuel cell. In this work we propose a novel model that represents accurately the structural properties of the membrane and couples the chemical and the mechanical degradations to estimate when the ultimate failure is initiated. The model is based on a network of agglomerated fibrils corresponding to the basic building block of the membrane structure 9–11. The mechanical and chemical properties are defined for each fibril and probability functions are used to evaluate the likelihood of a fibril to break under certain operating conditions. The description of the fundamentals behind the approach will be presented. Two set of simulations will be presented and discussed. The first one corresponding to standard testing scenarios that were used to validate the model. The second set of results will highlight the impact of coupling both degradation mechanisms on the estimation of the failure initiation time. The main strengths of the model and the future development will be discussed as well. T. Sinigaglia, F. Lewiski, M. E. Santos Martins, and J. C. Mairesse Siluk, Int. J. Hydrogen Energy, 42, 24597–24611 (2017). T. Jahnke et al., J. Power Sources, 304, 207–233 (2016). P. Ahmadi and E. Kjeang, Int. J. Energy Res., 714–727 (2016). X. Huang et al., J. Polym. Sci. Part B Polym. Phys., 44, 2346–2357 (2006). A. Sadeghi Alavijeh et al., J. Electrochem. Soc., 162, F1461–F1469 (2015). N. Macauley et al., J. Power Sources, 336, 240–250 (2016). K. H. Wong and E. Kjeang, J. Electrochem. Soc., 161, F823–F832 (2014). K. H. Wong and E. Kjeang, ChemSusChem, 8, 1072–1082 (2015). P.-É. A. Melchy and M. H. Eikerling, J. Phys. Condens. Matter, 27, 325103–6 (2015). J. A. Elliott et al., Soft Matter, 7, 6820 (2011). L. Rubatat, G. Gebel, and O. Diat, Macromolecules, 37, 7772–7783 (2004).


Author(s):  
Sang-Yeop Lee ◽  
In-Gyu Min ◽  
Hyoung-Juhn Kim ◽  
Suk Woo Nam ◽  
Jaeyoung Lee ◽  
...  

Due to the advantage of fuel cells over secondary batteries such as long operation time, many efforts were executed in order to use fuel cells as main power sources of small electronic devices such as laptop computers and mobile phones. For the same reason, fuel cells are promising power sources for the hazardous mission robots. Fuel cells are able to increase their radius action through extension of operation time. Despite this advantage, there still exist technical barriers such as increasing power density, efficient hydrogen storage, and fast startup of the power system. First, in order to increase power density, the united stack including proton exchange membrane fuel cells (PEMFC) and membrane humidifying cells were developed. Also, the hydrogen generating system using NaBH4 solution was employed to store hydrogen effectively. In addition, to shorten start-up time, hybrid control of PEMFC and Li-ion battery was adopted. The approaches mentioned above were evaluated. The developed PEMFC/humidifier stack showed high performance. As compared with full humidification condition by external humidifiers, the performance decrease was only 1% even though hydrogen was not humidified and air was partially humidified. Besides, by integrating the PEMFC and the humidifier into a single stack, considerable space for tubing between them was saved. Also, the hydrogen generator operated well with the PEMFC system and allowed for effective fuel storing and refueling. In addition, due to the efficient hybrid control of PEMFC and battery, start-up time was significantly shortened and capacity of PEMFC was reduced, resulting in compactness of the power system. In conclusion, a 600 W PEMFC power system was developed and successfully operated with the robot. Through development and evaluation of the PEMFC power system, the possibility of PEMFC as a novel power source for the hazardous mission robot was verified.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 596 ◽  
Author(s):  
Samuel Simon Araya ◽  
Vincenzo Liso ◽  
Xiaoti Cui ◽  
Na Li ◽  
Jimin Zhu ◽  
...  

This review presents methanol as a potential renewable alternative to fossil fuels in the fight against climate change. It explores the renewable ways of obtaining methanol and its use in efficient energy systems for a net zero-emission carbon cycle, with a special focus on fuel cells. It investigates the different parts of the carbon cycle from a methanol and fuel cell perspective. In recent years, the potential for a methanol economy has been shown and there has been significant technological advancement of its renewable production and utilization. Even though its full adoption will require further development, it can be produced from renewable electricity and biomass or CO2 capture and can be used in several industrial sectors, which make it an excellent liquid electrofuel for the transition to a sustainable economy. By converting CO2 into liquid fuels, the harmful effects of CO2 emissions from existing industries that still rely on fossil fuels are reduced. The methanol can then be used both in the energy sector and the chemical industry, and become an all-around substitute for petroleum. The scope of this review is to put together the different aspects of methanol as an energy carrier of the future, with particular focus on its renewable production and its use in high-temperature polymer electrolyte fuel cells (HT-PEMFCs) via methanol steam reforming.


2016 ◽  
Vol 4 (47) ◽  
pp. 18607-18613 ◽  
Author(s):  
Jinfa Chang ◽  
Ligang Feng ◽  
Kun Jiang ◽  
Huaiguo Xue ◽  
Wen-Bin Cai ◽  
...  

A novel Pt–CoP/C electrocatalyst was developed for direct methanol fuel cells. This catalyst showed superior power density to commercial Pt/C and PtRu/C catalysts. In situ ATR-SEIRAS technology revealed that the presence of CoP in the Pt-based catalyst can promote the methanol oxidation to final CO2 products.


2005 ◽  
Vol 2 (2) ◽  
pp. 121-135 ◽  
Author(s):  
A. Mawardi ◽  
F. Yang ◽  
R. Pitchumani

The performance of fuel cells can be significantly improved by using optimum operating conditions that maximize the power density subject to constraints. Despite its significance, relatively scant work is reported in the open literature on the model-assisted optimization of fuel cells. In this paper, a methodology for model-based optimization is presented by considering a one-dimensional nonisothermal description of a fuel cell operating on reformate feed. The numerical model is coupled with a continuous search simulated annealing optimization scheme to determine the optimum solutions for selected process constraints. Optimization results are presented over a range of fuel cell design parameters to assess the effects of membrane thickness, electrode thickness, constraint values, and CO concentration on the optimum operating conditions.


Author(s):  
Pinchas Schechner ◽  
Eugenia Bubis ◽  
Hana Faiger ◽  
Eyal Zussman ◽  
Ehud Kroll

This work adds more experimental evidence regarding the feasibility of using glucose to fuel fuel-cells with anodes that have a high area-to-volume ratio. Electrospinning was used to fabricate sub-micrometer size fibrous electrocatalytic anode membranes for the oxidation of glucose in an alkaline fuel cell (AFC). The fibers of the membranes were made of polyacrylonitrile (PAN) and coated with silver by electroless plating. The anodes were tested while installed in a membranless fuel cell. The results presented include the open circuit voltage, OCV, the polarization curve, the power density as a function of the current density, and the peak power density, PPD. The measurements were performed with constant concentrations of glucose, 0.8 M, and KOH electrolyte solution, 1M. The performance of the anodes was found to improve as the diameter of the silver-plated fibers decreased. The highest PPD of 0.28 mW/cm2 was obtained with an anode made of plated fibers having a mean fiber diameter of 130 nanometers. We conclude from the results that saccharides in general, and glucose in particular, can serve as fuels for fuel cells, and that silver-plated polymeric electrospun electrodes have advantages due to their large surface area.


Sign in / Sign up

Export Citation Format

Share Document