Comparison of Steady and Unsteady Coupled Heat-Transfer Simulations of a High-Pressure Turbine Blade

Author(s):  
Markus Schmidt ◽  
Christoph Starke

This article presents results for the coupled simulation of a high-pressure turbine stage in consideration of unsteady hot gas flows. A semi-unsteady coupling process was developed to solve the conjugate heat transfer problem for turbine components of gas turbines. Time-resolved CFD simulations are coupled to a finite element solver for the steady state heat conduction inside of the blade material. A simplified turbine stage geometry is investigated in this paper to describe the influence of the unsteady flow field onto the time-averaged heat transfer. Comparisons of the time-resolved results to steady state results indicate the importance of a coupled simulation and the consideration of the time-dependent flow-field. Different film-cooling configurations for the turbine NGV are considered, resulting in different temperature and pressure deficits in the vane wake. Their contribution to non-linear effects causing the time-averaged heat load to differ from a steady result is discussed to further highlight the necessity of unsteady design methods for future turbine developments. A strong increase in the pressure side heat transfer coefficients for unsteady simulations is observed in all results. For higher film-cooling mass flows in the upstream row, the preferential migration of hot fluid towards the pressure side of a turbine blade is amplified as well, which leads to a strong increase in material temperature at the pressure side and also in the blade tip region.

2011 ◽  
Vol 134 (4) ◽  
Author(s):  
S. Naik ◽  
C. Georgakis ◽  
T. Hofer ◽  
D. Lengani

This paper investigates the flow, heat transfer, and film cooling effectiveness of advanced high pressure turbine blade tips and endwalls. Two blade tip configurations have been studied, including a full rim squealer and a partial squealer with leading edge and trailing edge cutouts. Both blade tip configurations have pressure side film cooling and cooling air extraction through dust holes, which are positioned along the airfoil camber line on the tip cavity floor. The investigated clearance gap and the blade tip geometry are typical of that commonly found in the high pressure turbine blades of heavy-duty gas turbines. Numerical studies and experimental investigations in a linear cascade have been conducted at a blade exit isentropic Mach number of 0.8 and a Reynolds number of 9×105. The influence of the coolant flow ejected from the tip dust holes and the tip pressure side film holes has also been investigated. Both the numerical and experimental results showed that there is a complex aerothermal interaction within the tip cavity and along the endwall. This was evident for both tip configurations. Although the global heat transfer and film cooling characteristics of both blade tip configurations were similar, there were distinct local differences. The partial squealer exhibited higher local film cooling effectiveness at the trailing edge but also low values at the leading edge. For both tip configurations, the highest heat transfer coefficients were located on the suction side rim within the midchord region. However, on the endwall, the highest heat transfer rates were located close to the pressure side rim and along most of the blade chord. Additionally, the numerical results also showed that the coolant ejected from the blade tip dust holes partially impinges onto the endwall.


Author(s):  
S. Naik ◽  
C. Georgakis ◽  
T. Hofer ◽  
D. Lengani

This paper investigates the flow, heat transfer and film cooling effectiveness of advanced high-pressure turbine blade tips and endwall. Two blade tip configurations have been studied, including a full rim squealer and a partial squealer with a leading edge and trailing edge cut-out. Both blade tip configurations have pressure side film cooling, and cooling air extraction through dust holes which are positioned along the airfoil camber line on the tip cavity floor. The investigated clearance gap and the blade tip geometry are typical of that commonly found in the high pressure turbine blades of heavy-duty gas turbines. Numerical studies and experimental investigations in a linear cascade have been conducted at a blade exit isentropic Mach number of 0.8 and a Reynolds number of 9 × 105. The influence of the coolant flow ejected from the tip dust holes and the tip pressure side film holes has also been investigated. Both the numerical and experimental results showed that there is a complex aero-thermal interaction within the tip cavity and along the endwall. This was evident for both tip configurations. Although, the global heat transfer and film cooling characteristics of both blade tip configurations were similar, there were distinct local differences. The partial squealer exhibited higher local film cooling effectiveness at the trailing edge but also low values at the leading edge. For both tip configurations, the highest heat transfer coefficients were located on the suction side rim within the mid-chord region. However on the endwall, the highest heat transfer rates were located close to the pressure side rim and along most of the blade chord. Additionally, the numerical results also showed that the coolant ejected from the blade tip dust holes partially impinges onto the endwall.


Author(s):  
Brian R. Green ◽  
Randall M. Mathison ◽  
Michael G. Dunn

The effect of rotor purge flow on the unsteady aerodynamics of a high-pressure turbine stage operating at design corrected conditions has been investigated both experimentally and computationally. The experimental configuration consisted of a single-stage high-pressure turbine with a modern film-cooling configuration on the vane airfoil as well as the inner and outer end-wall surfaces. Purge flow was introduced into the cavity located between the high-pressure vane and the high-pressure disk. The high-pressure blades and the downstream low-pressure turbine nozzle row were not cooled. All hardware featured an aerodynamic design typical of a commercial high-pressure ratio turbine, and the flow path geometry was representative of the actual engine hardware. In addition to instrumentation in the main flow path, the stationary and rotating seals of the purge flow cavity were instrumented with high frequency response, flush-mounted pressure transducers and miniature thermocouples to measure flow field parameters above and below the angel wing. Predictions of the time-dependent flow field in the turbine flow path were obtained using FINE/Turbo, a three-dimensional, Reynolds-Averaged Navier-Stokes CFD code that had the capability to perform both steady and unsteady analysis. The steady and unsteady flow fields throughout the turbine were predicted using a three blade-row computational model that incorporated the purge flow cavity between the high-pressure vane and disk. The predictions were performed in an effort to mimic the design process with no adjustment of boundary conditions to better match the experimental data. The time-accurate predictions were generated using the harmonic method. Part I of this paper concentrates on the comparison of the time-averaged and time-accurate predictions with measurements in and around the purge flow cavity. The degree of agreement between the measured and predicted parameters is described in detail, providing confidence in the predictions for flow field analysis that will be provided in Part II.


2021 ◽  
Author(s):  
Patrick R. Jagerhofer ◽  
Marios Patinios ◽  
Tobias Glasenapp ◽  
Emil Göttlich ◽  
Federica Farisco

Abstract Due to stringent environmental legislation and increasing fuel costs, the efficiencies of modern turbofan engines have to be further improved. Commonly, this is facilitated by increasing the turbine inlet temperatures in excess of the melting point of the turbine components. This trend has reached a point where not only the high-pressure turbine has to be adequately cooled, but also components further downstream in the engine. Such a component is the turbine center frame (TCF), having a complex aerodynamic flow field that is also highly influenced by purge-mainstream interactions. The purge air, being injected through the wheelspace cavities of the upstream high-pressure turbine, bears a significant cooling potential for the TCF. Despite this, fundamental knowledge of the influencing parameters on heat transfer and film cooling in the TCF is still missing. This paper examines the influence of purge-to-mainstream blowing ratio, purge-to-mainstream density ratio and purge flow swirl angle on the convective heat transfer coefficient and the film cooling effectiveness in the TCF. The experiments are conducted in a sector-cascade test rig specifically designed for such heat transfer studies using infrared thermography and tailor-made flexible heating foils with constant heat flux. The inlet flow is characterized by radially traversing a five-hole-probe. Three purge-to-mainstream blowing ratios and an additional no purge case are investigated. The purge flow is injected without swirl and also with engine-similar swirl angles. The purge swirl and blowing ratio significantly impact the magnitude and the spread of film cooling in the TCF. Increasing blowing ratios lead to an intensification of heat transfer. By cooling the purge flow, a moderate variation in purge-to-mainstream density ratio is investigated, and the influence is found to be negligible.


2021 ◽  
pp. 1-26
Author(s):  
Patrick René Jagerhofer ◽  
Marios Patinios ◽  
Tobias Glasenapp ◽  
Emil Goettlich ◽  
Federica Farisco

Abstract The imperative improvement in the efficiency of turbofan engines is commonly facilitated by increasing the turbine inlet temperature. This development has reached a point where also components downstream of the high-pressure turbine have to be adequately cooled. Such a component is the turbine center frame (TCF), known for a complex aerodynamic flow highly influenced by purge-mainstream interactions. The purge air, being injected through the wheelspace cavities of the upstream high-pressure turbine, bears a significant cooling potential for the TCF. Despite this, fundamental knowledge of the influencing parameters on heat transfer and film cooling in the TCF is still missing. This paper examines the influence of purge-to-mainstream blowing ratio, density ratio and purge swirl angle on heat transfer and film cooling in the TCF. The experiments are conducted in a sector-cascade test rig specifically designed for such heat transfer studies using infrared thermography and tailor-made flexible heating foils with constant heat flux. Three purge-to-mainstream blowing ratios and an additional no purge case are investigated. The purge flow is injected without swirl and also with engine-similar swirl angles. The purge swirl and blowing ratio significantly impact the magnitude and the spread of film cooling in the TCF. Increasing blowing ratios lead to an intensification of heat transfer. By cooling the purge flow, a moderate variation in purge-to-mainstream density ratio is investigated, and the influence is found to be negligible.


2013 ◽  
Vol 136 (1) ◽  
Author(s):  
Brian R. Green ◽  
Randall M. Mathison ◽  
Michael G. Dunn

The detailed mechanisms of purge flow interaction with the hot-gas flow path were investigated using both unsteady computationally fluid dynamics (CFD) and measurements for a turbine operating at design corrected conditions. This turbine consisted of a single-stage high-pressure turbine and the downstream, low-pressure turbine nozzle row with an aerodynamic design equivalent to actual engine hardware and typical of a commercial, high-pressure ratio, transonic turbine. The high-pressure vane airfoils and inner and outer end walls incorporated state-of-the-art film cooling, and purge flow was introduced into the cavity located between the high-pressure vane and disk. The flow field above and below the blade angel wing was characterized by both temperature and pressure measurements. Predictions of the time-dependent flow field were obtained using a three-dimensional, Reynolds-averaged Navier–Stokes CFD code and a computational model incorporating the three blade rows and the purge flow cavity. The predictions were performed to evaluate the accuracy obtained by a design style application of the code, and no adjustment of boundary conditions was made to better match the experimental data. Part I of this paper compared the predictions to the measurements in and around the purge flow cavity and demonstrated good correlation. Part II of this paper concentrates on the analytical results, looking at the primary gas path ingestion mechanism into the cavity as well as the effects of the rotor purge on the upstream vane and downstream rotor aerodynamics and thermodynamics. Ingestion into the cavity is driven by high static pressure regions downstream of the vane, high-velocity flow coming off the pressure side of the vane, and the blade bow waves. The introduction of the purge flow is seen to have an effect on the static pressure of the vane trailing edge in the lower 5% of span. In addition, the purge flow is weak enough that upon exiting the cavity, it is swept into the mainstream flow and provides no additional cooling benefits on the platform of the rotating blade.


Author(s):  
A. Sipatov ◽  
L. Gomzikov ◽  
V. Latyshev ◽  
N. Gladysheva

The present tendency of creating new aircraft engines with a higher level of fuel efficiency leads to the necessity to increase gas temperature at a high pressure turbine (HPT) inlet. To design such type of engines, the improvement of accuracy of the computational analysis is required. According to this the numerical analysis methods are constantly developing worldwide. The leading firms in designing aircraft engines carry out investigations in this field. However, this problem has not been resolved completely yet because there are many different factors affecting HPT blade heat conditions. In addition in some cases the numerical methods and approaches require tuning (for example to predict laminar-turbulent transition region or to describe the interaction of boundary layer and shock wave). In this work our advanced approach of blade heat condition numerical estimation based on the three-dimensional computational analysis is presented. The object of investigation is an advanced aircraft engine HPT first stage blade. The given analysis consists of two interrelated parts. The first part is a stator-rotor interaction modeling of the investigated turbine stage (unsteady approach). Solving this task we devoted much attention to modeling unsteady effects of stator-rotor interaction and to describing an influence of applied inlet boundary conditions on the blade heat conditions. In particular, to determine the total pressure, flow angle and total temperature distributions at the stage inlet we performed a numerical modeling of the combustor chamber of the investigated engine. The second part is a flow modeling in the turbine stage using flow parameters averaging on the stator-rotor interface (steady approach). Here we used sufficiently finer grid discretization to model all perforation holes on the stator vane and rotor blade, endwalls films in detail and to apply conjugate heat transfer approach for the rotor blade. Final results were obtained applying the results of steady and unsteady approaches. Experimental data of the investigated blade heat conditions are presented in the paper. These data were obtained during full size experimental testing the core of the engine and were collected using two different type of experimental equipment: thermocouples and thermo-crystals. The comparison of experimental data and final results meets the requirements of our investigation.


Author(s):  
Lars-Uno Axelsson ◽  
William K. George ◽  
T. Gunnar Johansson

This forum paper discusses phase-resolved turbulence measurements of the flow downstream of an axial turbine, and especially how phase-resolved measurements compare to time-resolved measurements. The time-resolved spectra produced higher velocity fluctuations than the corresponding phase-resolved spectra even when the periodic component was filtered out from the time-resolved measurements. The phase-resolved spectrum effectively removes all the peaks in the spectrum except for the ones associated with the blade-passage frequency.


Author(s):  
Hossein Nadali Najafabadi ◽  
Matts Karlsson ◽  
Mats Kinell ◽  
Esa Utriainen

Improving film cooling performance of turbine vanes and blades is often achieved through application of multiple arrays of cooling holes on the suction side, the showerhead region and the pressure side. This study investigates the pressure side cooling under the influence of single and multiple rows of cooling in the presence of a showerhead from a heat transfer coefficient augmentation perspective. Experiments are conducted on a prototype turbine vane working at engine representative conditions. Transient IR thermography is used to measure time-resolved surface temperature and the semi-infinite method is utilized to calculate the heat transfer coefficient on a low conductive material. Investigations are performed for cylindrical and fan-shaped holes covering blowing ratio 0.6 and 1.8 at density ratio of about unity. The freestream turbulence is approximately 5% close to the leading edge. The resulting heat transfer coefficient enhancement, the ratio of HTC with to that without film cooling, from different case scenarios have been compared to showerhead cooling only. Findings of the study highlight the importance of showerhead cooling to be used with additional row of cooling on the pressure side in order to reduce heat transfer coefficient enhancement. In addition, it is shown that extra rows of cooling will not significantly influence heat transfer augmentation, regardless of the cooling hole shape.


Author(s):  
Colinda Goormans-Francke ◽  
Guy Carabin ◽  
Charles Hirsch

The presented work demonstrates the feasibility of quasi-automatic structured mesh generation for all details in the complex cooling system of an industrial high pressure turbine stage, as required by advanced Conjugate Heat Transfer (CHT) simulations. The grid generation software has been adapted in order to quasi-automatically mesh typical cooling configurations such as cooling passages, basins, inserts, solid bodies, cooling holes, slots, and rib turbulators. A multi-domain structured mesh with about 154 million grid points and 12,316 blocks has been generated for the turbine stage. It includes 1,000 cooling holes, over 250 rib turbulators and 150 pin fins for the turbine stage. In order to verify the CFD response to the grid properties, simulations were performed as a first step on the coarse grid level (of 21.8 million grid points) using the 3D flow solver package FINE™/Turbo. The conductivity equation was solved for the solid part of the computational domain using the same temporal discretization scheme as for the flow solver. Parallel, coupled fluid/solid calculations using the k-ε turbulence model were performed on three different configurations: nozzle guide vane alone, rotor-blade alone, and full stage. These results show the feasibility of this approach to mesh generation for use in CHT modeling of the complex configuration of cooled turbine stages.


Sign in / Sign up

Export Citation Format

Share Document