Visualizations of Flow Structures in the Rotor Passage of an Axial Compressor at the Onset of Stall

Author(s):  
Huang Chen ◽  
Yuanchao Li ◽  
David Tan ◽  
Joseph Katz

Flow visualizations and stereoscopic PIV (SPIV) measurements are carried out to study the flow phenomena developing in the rotor passage of an axial compressor at the onset of stall. Experiments have been performed in the JHU optically index-matched facility, using acrylic blades and liquid that have the same optical refractive index. The blade geometries are based on the first one and a half stages of the Low Speed Axial Compressor (LSAC) facility at NASA Glenn. The SPIV measurements provide detailed snapshots and ensemble statistics on the flow in a series of meridional planes. Data recorded in closely spaced planes enable us to obtain ensemble averaged 3D vorticity distributions. High speed imaging of cavitation, performed at low pressure, is used to qualitatively visualize the vortical structures within the rotor passage. The observations are performed just above and at stall conditions. At pre-stall condition, shortly after it rolled up, the tip leakage vortex (TLV) breaks up into widely distributed intermittent vortical structures. In particular, interaction of the backward tip leakage flow with the nearly opposite direction main passage flow under (radially inward) it results in periodic generation of large scale vortices that extend upstream, from the suction side (SS) of one blade to the pressure side (PS) or even near the leading edge of the next blade. When these structures penetrate to the next passage, they trigger formation of a similar phenomenon there, initiating a process that sustains itself. Once they form, these vortices rotate with the blade, indicating little through flow in the tip region. The 3D velocity and vorticity distributions confirm the presence of these large flow structures at the transition between the high circumferential velocity region below the TLV center and the main flow deeper in the passage. Further reduction in flow rate into the stall range caused a rapid increase in the number and scale of these vortices, demonstrating that their formation and proliferation plays a key role in the onset of stall.

2017 ◽  
Vol 139 (4) ◽  
Author(s):  
Huang Chen ◽  
Yuanchao Li ◽  
David Tan ◽  
Joseph Katz

Experiments preformed in the JHU refractive index matched facility examine flow phenomena developing in the rotor passage of an axial compressor at the onset of stall. High-speed imaging of cavitation performed at low pressures qualitatively visualizes vortical structures. Stereoscopic particle image velocimetry (SPIV) measurements provide detailed snapshots and ensemble statistics of the flow in a series of meridional planes. At prestall condition, the tip leakage vortex (TLV) breaks up into widely distributed intermittent vortical structures shortly after rollup. The most prominent instability involves periodic formation of large-scale backflow vortices (BFVs) that extend diagonally upstream, from the suction side (SS) of one blade at midchord to the pressure side (PS) near the leading edge of the next blade. The 3D vorticity distributions obtained from data recorded in closely spaced planes show that the BFVs originate form at the transition between the high circumferential velocity region below the TLV center and the main passage flow radially inward from it. When the BFVs penetrate to the next passage across the tip gap or by circumventing the leading edge, they trigger a similar phenomenon there, sustaining the process. Further reduction in flow rate into the stall range increases the number and size of the backflow vortices, and they regularly propagate upstream of the leading edge of the next blade, where they increase the incidence angle in the tip corner. As this process proliferates circumferentially, the BFVs rotate with the blades, indicating that there is very little through flow across the tip region.


2013 ◽  
Vol 135 (5) ◽  
Author(s):  
Joshua D. Cameron ◽  
Matthew A. Bennington ◽  
Mark H. Ross ◽  
Scott C. Morris ◽  
Juan Du ◽  
...  

Experimental and numerical studies were conducted to investigate tip-leakage flow and its relationship to stall in a transonic axial compressor. The computational fluid dynamics (CFD) results were used to identify the existence of an interface between the approach flow and the tip-leakage flow. The experiments used a surface-streaking visualization method to identify the time-averaged location of this interface as a line of zero axial shear stress at the casing. The axial position of this line, denoted xzs, moved upstream with decreasing flow coefficient in both the experiments and computations. The line was consistently located at the rotor leading edge plane at the stalling flow coefficient, regardless of inflow boundary condition. These results were successfully modeled using a control volume approach that balanced the reverse axial momentum flux of the tip-leakage flow with the momentum flux of the approach fluid. Nonuniform tip clearance measurements demonstrated that movement of the interface upstream of the rotor leading edge plane leads to the generation of short length scale rotating disturbances. Therefore, stall was interpreted as a critical point in the momentum flux balance of the approach flow and the reverse axial momentum flux of the tip-leakage flow.


Author(s):  
Yanfei Gao ◽  
Yangwei Liu ◽  
Luyang Zhong ◽  
Jiexuan Hou ◽  
Lipeng Lu

AbstractThe standard k-ε model (SKE) and the Reynolds stress model (RSM) are employed to predict the tip leakage flow (TLF) in a low-speed large-scale axial compressor rotor. Then, a new research method is adopted to “freeze” the turbulent kinetic energy and dissipation rate of the flow field derived from the RSM, and obtain the turbulent viscosity using the Boussinesq hypothesis. The Reynolds stresses and mean flow field computed on the basis of the frozen viscosity are compared with the results of the SKE and the RSM. The flow field in the tip region based on the frozen viscosity is more similar to the results of the RSM than those of the SKE, although certain differences can be observed. This finding indicates that the non-equilibrium turbulence transport nature plays an important role in predicting the TLF, as well as the turbulence anisotropy.


2021 ◽  
Vol 143 (4) ◽  
Author(s):  
Teng Cao ◽  
Tadashi Kanzaka ◽  
Liping Xu ◽  
Tobias Brandvik

Abstract In this paper, an unsteady tip leakage flow phenomenon is identified and investigated in a centrifugal compressor with a vaneless diffuser at near-stall conditions. This phenomenon is associated with the inception of a rotating instability in the compressor. The study is based on numerical simulations that are supported by experimental measurements. The study confirms that the unstable flow is governed by a Kelvin–Helmholtz type instability of the shear layer formed between the main-stream flow and the tip leakage flow. The shear layer instability induces large-scale vortex roll-up and forms vortex tubes, which propagate circumferentially, resulting in measured pressure fluctuations with short wavelength and high amplitude which rotate at about half of the blade speed. The 3D vortex tube is also found to interact with the main blade leading edge, causing the reduction of the blade loading identified in the experiment. The paper also reveals that the downstream volute imposes a once-per-rev circumferential nonuniform back pressure at the impeller exit, inducing circumferential loading variation at the impeller inducer, and causing circumferential variation in the unsteady tip leakage flow.


2019 ◽  
Vol 141 (12) ◽  
Author(s):  
Yangwei Liu ◽  
Luyang Zhong ◽  
Lipeng Lu

Tip leakage vortex (TLV) has a large impact on compressor performance and should be accurately predicted by computational fluid dynamics (CFD) methods. New approaches of turbulence modeling, such as delayed detached eddy simulation (DDES), have been proposed, the computational resources of which can be reduced much more than for large eddy simulation (LES). In this paper, the numerical simulations of the rotor in a low-speed large-scale axial compressor based on DDES and unsteady Reynolds-averaged Navier–Stokes (URANS) are performed, thus improving our understanding of the TLV dynamic mechanisms and discrepancy of these two methods. We compared the influence of different time steps in the URANS simulation. The widely used large time-step makes the unsteadiness extremely weak. The small time-step shows a better result close to DDES. The time-step scale is related to the URANS unsteadiness and should be carefully selected. In the time-averaged flow, the TLV in DDES dissipates faster, which has a more similar structure to the experiment. Then, the time-averaged and instantaneous results are compared to divide the TLV into three parts. URANS cannot give the loss of stability and evolution details of TLV. The fluctuation velocity spectra show that the amplitude of high frequencies becomes obvious downstream from the TLV, where it becomes unstable. Last, the anisotropy of the Reynolds stress of these two methods is analyzed through the Lumley triangle to see the distinction between the methods and obtain the Reynolds stress. The results indicate that the TLV latter part in DDES is anisotropic, while in URANS it is isotropic.


Entropy ◽  
2020 ◽  
Vol 22 (12) ◽  
pp. 1372
Author(s):  
Mingming Zhang ◽  
Anping Hou

In order to explore the inducing factors and mechanism of the non-synchronous vibration, the flow field structure and its formation mechanism in the non-synchronous vibration state of a high speed turbocompressor are discussed in this paper, based on the fluid–structure interaction method. The predicted frequencies fBV (4.4EO), fAR (9.6EO) in the field have a good correspondence with the experimental data, which verify the reliability and accuracy of the numerical method. The results indicate that, under a deviation in the adjustment of inlet guide vane (IGV), the disturbances of pressure in the tip diffuse upstream and downstream, and maintain the corresponding relationship with the non-synchronous vibration frequency of the blade. An instability flow that developed at the tip region of 90% span emerged due to interactions among the incoming main flow, the axial separation backflow, and the tip leakage vortices. The separation vortices in the blade passage mixed up with the tip leakage flow reverse at the trailing edge of blade tip, presenting a spiral vortex structure which flows upstream to the leading edge of the adjacent blade. The disturbances of the spiral vortexes emerge to rotate at 54.5% of the rotor speed in the same rotating direction as a modal oscillation. The blade vibration in the turbocompressor is found to be related to the unsteadiness of the tip flow. The large pressure oscillation caused by the movement of the spiral vortex is regarded as the one of the main drivers for the non-synchronous vibration for the present turbocompressor, besides the deviation in the adjustment of IGV.


2014 ◽  
Vol 30 (3) ◽  
pp. 307-313 ◽  
Author(s):  
R. Taghavi-Zenou ◽  
S. Abbasi ◽  
S. Eslami

ABSTRACTThis paper deals with tip leakage flow structure in subsonic axial compressor rotor blades row under different operating conditions. Analyses are based on flow simulation utilizing computational fluid dynamic technique. Three different circumstances at near stall condition are considered in this respect. Tip leakage flow frequency spectrum was studied through surveying instantaneous static pressure signals imposed on blades surfaces. Results at the highest flow rate, close to the stall condition, showed that the tip vortex flow fluctuates with a frequency close to the blade passing frequency. In addition, pressure signals remained unchanged with time. Moreover, equal pressure fluctuations at different passages guaranteed no peripheral disturbances. Tip leakage flow frequency decreased with reduction of the mass flow rate and its structure was changing with time. Spillage of the tip leakage flow from the blade leading edge occurred without any backflow in the trailing edge region. Consequently, various flow structures were observed within every passage between two adjacent blades. Further decrease in the mass flow rate provided conditions where the spilled flow ahead of the blade leading edge together with trailing edge backflow caused spike stall to occur. This latter phenomenon was accompanied by lower frequencies and higher amplitudes of the pressure signals. Further revolution of the rotor blade row caused the spike stall to eventuate to larger stall cells, which may be led to fully developed rotating stall.


Author(s):  
Wei Li ◽  
Hongmei Jiang ◽  
Qiang Zhang ◽  
Sang Woo Lee

The over-tip-leakage (OTL) flow characteristics for a typical squealer tip of a high-pressure turbine blade, which consists of subsonic and transonic flow, have been numerically investigated in the present study, in comparison with the corresponding flat tip results. For the squealer tip employed, flow choking behavior still exists above the tip surface, even though the Mach number is lower and the transonic region is smaller than that for the flat tip. Detailed flow structure analysis shows that most of the fluid entering the squealer cavity is from the frontal leading edge region. The fluid migrates along the cavity and is ejected at various locations near the suction side rim. These fluids form a large subsonic flow zone under the supersonic flow passing over the tip gap which reduces the OTL flow flux. The squealer design works even in the presence of choked OTL flow. Comparisons between results from three different cavity depths with and without relative casing motion suggest that the over-tip-leakage flow flux has much dependence upon the cavity depth for the subsonic region, but is less sensitive to the depth for the transonic tip flow region. Such behavior has been confirmed with and without the existence of relative casing motion.


2009 ◽  
Vol 131 (2) ◽  
Author(s):  
Nicolas Gourdain ◽  
Francis Leboeuf

This paper deals with the numerical simulation of technologies to increase the compressor performances. The objective is to extend the stable operating range of an axial compressor stage using passive control devices located in the tip region. First, the behavior of the tip leakage flow is investigated in the compressor without control. The simulation shows an increase in the interaction between the tip leakage flow and the main flow when the mass flow is reduced, a phenomenon responsible for the development of a large flow blockage region at the rotor leading edge. A separation of the rotor suction side boundary layer is also observed at near stall conditions. Then, two approaches are tested in order to control these flows in the tip region. The first one is a casing treatment with nonaxisymmetric slots. The method showed a good ability to control the tip leakage flow but failed to reduce the boundary layer separation on the suction side. However, an increase in the operability was observed but with a penalty for the efficiency. The second approach is a blade treatment that consists of a longitudinal groove built in the tip of each rotor blade. The simulation pointed out that the device is able to control partially all the critical flows with no penalty for the efficiency. Finally, some recommendations for the design of passive treatments are presented.


Author(s):  
Ashwin Ashok ◽  
Patur Ananth Vijay Sidhartha ◽  
Shine Sivadasan

Abstract Tip clearance of axial compressor blades allows leakage of the flow, generates significant losses and reduces the compressor efficiency. The present paper aims to discuss the axial compressor tip aerodynamics for various configurations of tip gap with trench. The various configurations are obtained by varying the clearance, trench depth, step geometry and casing contouring. In this paper the axial compressor aerodynamics for various configurations of tip gap with trench have been studied. The leakage flow structure, vorticity features and entropy generations are analyzed using RANS based CFD. The linear compressor cascade comprises of NACA 651810 blade with clearance height varied from 0.5% to 2% blade span. Trail of the tip leakage vortex and the horseshoe vortex on the blade suction side are clearly seen for the geometries with and without casing treatments near the stalling point. Since the trench side walls are similar to forward/backing steps, a step vortex is observed near the leading edge as well as trailing edge of the blade and is not seen for the geometry without the casing treatment. Even though the size of the tip leakage vortex seams to be reduces by providing a trench to the casing wall over the blade, the presence of additional vortices like the step vortex leads to comparatively higher flow losses. An increase in overall total pressure loss due to the application of casing treatment is observed. However an increase in stall margin for the geometries with casing is noted.