Evaluation of Two 300 MWe Fourth Generation PbBi Reactor System Concepts

Author(s):  
Laurence F. Miller ◽  
M. Khurram Khan ◽  
Wesley Williams ◽  
F. R. Mynatt

This paper describes the evaluation of two 300 MWe modular PbBi cooled reactor system concepts that can be field assembled from components shipped on standard rail cars or on trucks. Thus, the largest components must be smaller than 12’ × 12’ × 80’ (3.66 m × 3.66 m × 24.4m) and should weigh no more than 80 tons. One of these systems utilizes a cylindrical two-loop containment vessel for the core and the other is a slab design. The fuel for both designs consists of standard-sized metallic IFR fuel in 17×17 square array assemblies with a pitch-to-diameter ratio of 1.15. The coolant outlet temperature is limited by current material technology, which is estimated to be 550 C. The primary coolant inlet temperature is selected to be 350 C. This is well above the melting temperature of PbBi, and it is expected to be sufficiently high to limit transient-induced thermal stresses to acceptable values. Coolant flow rates through the core and external piping are below 1 m/s. The results from neutronics calculations include power distributions, reactivity coefficients, and fuel depletion, and results from heat transfer calculations include temperatures and flow rates at various locations in the primary and secondary systems. The neutronic design calculations are accomplished by using a discrete ordinate transport code and a cross section processing system developed at Oak Ridge National Laboratory. Two-dimensional flux distributions are obtained with the DOORS system, and ORIGEN-S, coupled with KENO, is used for time-dependent depletion calculations. The thermal-hydraulic design of the core consists of heat transfer and fluid flow calculation for an average channel. The inlet and outlet temperatures, along with the fuel centerline temperature, are determined in conjunction with core flow rates, pumping power, and total power output. This is accomplished by using a lumped parameter steady-state model with a spreadsheet and by using a one-dimensional time-dependent model. Results from the thermal-hydraulic calculation obtain a thermal efficiency of 41%, but an efficiency of about 45% could be obtained. The nominal power density and good thermal conductivity of Pb-Bi will permit decay heat to be handled more effectively than for sodium-cooled design or for light water reactors. The low vapor pressure of Pb-Bi permits the use of a thin walled pressure vessel on the order of centimeters as compared to the 30–40 cm thick PWR vessel, and the high boiling point of the lead bismuth assures that the core will remain covered in the event of a loss of coolant outside the primary vessel.

Author(s):  
V. G. Razumovskiy ◽  
Eu. N. Pis’mennyy ◽  
A. Eu. Koloskov ◽  
I. L. Pioro

The results of heat transfer to supercritical water flowing upward in a vertical annular channel (1-rod channel) and tight 3-rod bundle consisting of the tubes of 5.2-mm outside diameter and 485-mm heated length are presented. The heat-transfer data were obtained at pressures of 22.5, 24.5, and 27.5 MPa, mass flux within the range from 800 to 3000 kg/m2·s, inlet temperature from 125 to 352°C, outlet temperature up to 372°C and heat flux up to 4.6 MW/m2 (heat flux rate up to 2.5 kJ/kg). Temperature regimes of the annular channel and 3-rod bundle were stable and easily reproducible within the whole range of the mass and heat fluxes, even when a deteriorated heat transfer took place. The data resulted from the study could be applicable for a reference estimation of heat transfer in future designs of fuel bundles.


2015 ◽  
Vol 19 (6) ◽  
pp. 2039-2048 ◽  
Author(s):  
Hafiz Ali ◽  
Muhammad Azhar ◽  
Musab Saleem ◽  
Qazi Saeed ◽  
Ahmed Saieed

The focus of this research paper is on the application of water based MgO nanofluids for thermal management of a car radiator. Nanofluids of different volumetric concentrations (i.e. 0.06%, 0.09% and 0.12%) were prepared and then experimentally tested for their heat transfer performance in a car radiator. All concentrations showed enhancement in heat transfer compared to the pure base fluid. A peak heat transfer enhancement of 31% was obtained at 0.12 % volumetric concentration of MgO in basefluid. The fluid flow rate was kept in a range of 8-16 liter per minute. Lower flow rates resulted in greater heat transfer rates as compared to heat transfer rates at higher flow rates for the same volumetric concentration. Heat transfer rates were found weakly dependent on the inlet fluid temperature. An increase of 8?C in inlet temperature showed only a 6% increase in heat transfer rate.


Author(s):  
Masanori Ohtani ◽  
Akito Kozuru ◽  
Yasuyuki Kashimoto ◽  
Mitsuto Montani ◽  
Koutaro Takeda ◽  
...  

Asymmetric thermal-hydraulic conditions among primary loops during a postulated steam line break (SLB) induce a non-uniform temperature distribution at a core inlet. When coolant of lower temperature intrudes into a part of core, it leads to a reactivity insertion and a local power increase. Therefore, an appropriate model for the core inlet temperature distribution is required for a realistic SLB analysis. In this study, numerical experiments were conducted to examine the core inlet temperature distribution under the asymmetric thermal-hydraulic coolant conditions among primary loops. 3D steady-state calculations were carried out for Japanese standard Pressurized Water Reactor (PWR) such as 2, 3, 4 loop types and an advanced PWR. Since the flow in a reactor vessel involves time-dependent velocity fluctuations due to a high Reynolds number condition and a complicated geometry of flow path, the turbulent mixing might be enhanced. Hence, the turbulent thermal diffusivity for the steady-state calculation was examined based on experimental results and another transient calculation. As a result, it was confirmed that (1) the turbulent mixing in a downcomer and a lower plenum were enhanced due to time-dependent velocity fluctuations and therefore the turbulent thermal diffusivity for steady-state calculation was specified to be greater, (2) the core inlet temperature distribution predicted by a steady-state calculation reasonably agreed with a experimental data, (3) the patterns of core inlet temperature distribution were comprehended to be dependent on the plant type, i.e. the number of primary loop and (4) under a low flow rate condition, the coolant of lower temperature appeared on the opposite side of the affected loop due to the effect of a natural convection.


Author(s):  
Takayuki Matsunuma ◽  
Hiro Yoshida ◽  
Norihiko Iki ◽  
Takumi Ebara ◽  
Satoshi Sodeoka ◽  
...  

A series of operation tests of a ceramic micro gas turbine has been successfully carried out. The baseline machine is a small single-shaft turbojet engine (J-850, Sophia Precision Corp.) with a centrifugal compressor, an annular type combustor, and a radial turbine. As a first step, an Inconel 713C alloy turbine rotor of 55 mm in diameter was replaced with a ceramic rotor (SN-235, Kyocera Corporation). A running test was conducted at rotational speeds of up to 140,000 rpm in atmospheric air. At this rotor speed, the compression pressure ratio and the thrust were 3 and 100 N, respectively. The total energy level (enthalpy and kinetic energy) of the exhaust gas jet was 240 kW. If, for example, it is assumed that 10% of the total power of the exhaust jet gas was converted into electricity, the present system would correspond to a generator with 24 kW output power. The measured turbine outlet temperature was 950°C (1,740°F) and the turbine inlet temperature was estimated to be 1,280°C (2,340°F). Although the ceramic rotor showed no evidence of degradation, the Inconel nozzle immediately in front of the turbine rotor partially melted in this rotor condition. As a second step, the Inconel turbine nozzle and casing were replaced with ceramic parts (SN-01, Ohtsuka Ceramics Inc.). The ceramic nozzle and case were supported by metal parts. Through tests with the ceramic nozzle, it became evident that one of the key technologies for the development of ceramic gas turbines is the design of the interface between the ceramic components and the metallic components, because the difference between the coefficients of linear thermal expansion of the ceramic and metal produces large thermal stress at their interface in the high-temperature condition. A buffer material made of alumina fiber was therefore introduced at the interface between the ceramic and metal.


Author(s):  
Jose Urcia ◽  
Michael Kinzel

Abstract The Discrete Element Roughness Method (DERM) has been used to improve convective heat transfer predictions on surface roughness. This work aims to validate the core momentum-correlation of DERM through evaluating Computational fluid dynamics (CFD)-based solution of the flow around individual roughness elements with the goal of improving the correlations. More specifically, the matrix of scenarios evaluated using includes three different roughness elements at three different pressure drops (or flow rates). Results from these studies are to be used to validate and improve correlations used to approximate roughness in DERM. For further comparison, a fourth roughness element analyzed in previous work will also be compared. For each element, a steady and unsteady case are conducted and analyzed. The momentum loss results obtained from the CFD are then compared to the DERM-based predictions from the same roughness elements in search of any discrepancies. It is observed the momentum-correlation deviates from the CFD prediction with increasing element height.


Author(s):  
Debora C. Moreira ◽  
Gherhardt Ribatski ◽  
Satish G. Kandlikar

Abstract This paper presents a comparison of heat transfer and pressure drop during single-phase flows inside diverging, converging, and uniform microgaps using distilled water as the working fluid. The microgaps were created on a plain heated copper surface with a polysulfone cover that was either uniform or tapered with an angle of 3.4°. The average gap height was 400 microns and the length and width dimensions were 10 mm × 10 mm, resulting in an average hydraulic diameter of approximately 800 microns for all configurations. Experiments were conducted at atmospheric pressure and the inlet temperature was set to 30 °C. Heat transfer and pressure drop data were acquired for flow rates varying from 57 to 485 ml/min and the surface temperature was monitored not to exceed 90 °C to avoid bubble nucleation, so the heat flux varied from 35 to 153 W/cm2 depending on the flow rate. The uniform configuration resulted in the lowest pressure drop, and the diverging one showed slightly higher pressure drop values than the converging configuration, possibly because the flow is most constrained at the inlet section, where the fluid is colder and presents higher viscosity. In addition, a minor dependence of pressure drop with heat flux was observed due to temperature dependent properties. The best heat transfer performance was obtained with the converging configuration, which was especially significant at low flow rates. This behavior could be explained by an increase in the heat transfer coefficient due to flow acceleration in converging gaps, which compensates the decrease in temperature difference between the fluid and the surface due to fluid heating along the gap. Overall, the comparison between the three configurations shows that converging microgaps have better performance than uniform or diverging ones for single-phase flows, and such effect is more pronounced at lower flow rates, when the fluid experiences higher temperature changes.


2017 ◽  
Vol 865 ◽  
pp. 143-148
Author(s):  
Gyung Ju Kang ◽  
Seok Swoo Cho ◽  
Sung Riong Lee

This paper presents the optimal design of vent pipe in a fire station by using design of experiments and analytical method of heat transfer theory. In order to calculate formulation without using tables, equations in terms of temperature are developed for five air properties such as specific heat, thermal conductivity, kinematic viscosity, density and Prandtl number. It is shown that the equations accurately approximate the variations of air properties in terms of temperature. Series of design analysis are performed under considering the process parameters such as inlet temperature, pipe diameter and heat transfer rate. Orthogonal arrays of L27 are used. The signal-to-noise (S/N) and analysis of variance (ANOVA) are utilized to determine the effect of parameters on objective functions, surface temperature and outlet temperature. From the results it is clear that inlet temperature is prominent on objective function.


Author(s):  
Krysten King ◽  
Amjad Farah ◽  
Sahil Gupta ◽  
Sarah Mokry ◽  
Igor Pioro

Many heat-transfer correlations exist for bare tubes cooled with SuperCritical Water (SCW). However, there is very few correlations that describe SCW heat transfer in bundles. Due to the lack of extensive data on bundles, a limited dataset on heat transfer in a SCW-cooled bundle was studied and analyzed using existing bare-tube correlations to find the best-fit correlation. This dataset was obtained by Razumovskiy et al. (National Technical University of Ukraine “KPI”) in SCW flowing upward in a vertical annular channel (1-rod channel) and tight 3-rod bundle consisting of tubes of 5.2-mm outside diameter and 485-mm heated length. The heat-transfer data were obtained at pressures of 22.5, 24.5, and 27.5 MPa, mass flux within a range from 800 to 3000 kg/m2s, inlet temperature from 125 to 352°C, outlet temperature up to 372°C and heat flux up to 4.6 MW/m2. The objective of this study is to compare bare-tube SCW heat-transfer correlations with the data on 1- and 3-rod bundles. This work is in support of SuperCritical Water-cooled Reactors (SCWRs) as one of the six concepts of Generation-IV nuclear systems. SCWRs will operate at pressures of ∼25MPa and inlet temperatures of 350°C.


2011 ◽  
Vol 145 ◽  
pp. 129-133 ◽  
Author(s):  
Thanhtrung Dang ◽  
Ngoctan Tran ◽  
Jyh Tong Teng

The study was done both numerically and experimentally on the heat transfer behaviors of a microchannel heat sink. The solver of numerical simulations (CFD - ACE+software package) was developed by using the finite volume method. This numerical method was performed to simulate for an overall microchannel heat sink, including the channels, substrate, manifolds of channels as well as the covered top wall. Numerical results associated with such kinds of overall microchannel heat sinks are rarely seen in the literatures. For cases done in this study, a heat flux of 9.6 W/cm2was achieved for the microchannel heat sink having the inlet temperature of 25 °C and mass flow rate of 0.4 g/s with the uniform surface temperature of bottom wall of the substrate of 50 °C; besides, the maximum heat transfer effectiveness of this device reached 94.4%. Moreover, in this study, when the mass flow rate increases, the outlet temperature decreases; however, as the mass flow rate increases, the heat flux of this heat sink increases also. In addition, the results obtained from the numerical analyses were in good agreement with those obtained from the experiments as well as those from the literatures, with the maximum discrepancies of the heat fluxes estimated to be less than 6 %.


1988 ◽  
Vol 110 (2) ◽  
pp. 90-97 ◽  
Author(s):  
R. Celentano ◽  
R. Kirchner

An experimental study was conducted on the operation of a “once-through” thermosiphon system. This new type of natural circulation system, unlike the standard thermosiphon system, heats the collector fluid in one pass without any recirculation. An electrically heated manifold was used to simulate the useful solar gain. Power was varied with time in 22 half-hour increments to simulate the actual daily useful solar gain. The time-dependent responses of the system in terms of temperatures and mass flow rates were recorded and plotted. The response time for mass flow and temperature to approach steady state varied directly with the size of the power step. Two experiments were conducted; one which tracked mass flows and outlet temperatures for variable useful solar gains, and a second which tracked mass flows at constant outlet temperature for variable useful solar gains.