Effects of Biased AC Electroosmotic Micro-Pumping on Symmetric and Asymmetric Electrode Arrays

Author(s):  
Nazmul Islam

This paper presents an analysis and experiment results that were conducted to assess the effect of combining an AC signal with a DC bias when generating the electric field on electrode arrays needed to impart electroosmosis within a microchannel. The analysis was done using COMSOL 3.5a in which currently available theoretical models for EO flows were embedded in the software and solved numerically. The simulation evaluate the effects of channel geometry, frequency of excitation, electrode array geometry, and AC signal with a DC bias on the flow imparted on an electrically conducting fluid. For the AC driven flow, the simulation results indicate the existence of an optimized frequency of excitation and an optimum geometry that lead to the maximum net forward flow of the pump. No relevant net flows were generated with the symmetric electrode arrays with a constant magnitude of AC voltage applied to both electrodes. However, superimposing a DC signal over the AC signal on the same symmetric electrode array lead to a noticeable net forward flow of 18.70 μL/min. On the other hand asymmetric electrode pattern can generate flow in both cases and can improve the microflow inside the micro-channel. Experimental flow measurements were performed on several electrode array configurations manufactured using typical MEMS fabrication techniques. The experimental results are in good agreement with the simulation data. They confirm that using an asymmetric electrode array excited by an AC signal with a DC bias leads to a significant improvement in flow rates in comparison to the flow rates obtained in an asymmetric electrode array configuration excited just with an AC signal.

2007 ◽  
Vol 97 (5) ◽  
pp. 3781-3789 ◽  
Author(s):  
Ian Nauhaus ◽  
Dario L. Ringach

Recent theoretical models of primary visual cortex predict a relationship between receptive field properties and the location of the neuron within the orientation maps. Testing these predictions requires the development of new methods that allow the recording of single units at various locations across the orientation map. Here we present a novel technique for the precise alignment of functional maps and array recordings. Our strategy consists of first measuring the orientation maps in V1 using intrinsic optical imaging. A micromachined electrode array is subsequently implanted in the same patch of cortex for electrophysiological recordings, including the measurement of orientation tuning curves. The location of the array within the map is obtained by finding the position that maximizes the agreement between the preferred orientations measured electrically and optically. Experimental results of the alignment procedure from two implementations in monkey V1 are presented. The estimated accuracy of the procedure is evaluated using computer simulations. The methodology should prove useful in studying how signals from the local neighborhood of a neuron, thought to provide a dominant feedback signal, shape the receptive field properties in V1.


2021 ◽  
Vol 11 (9) ◽  
pp. 4144
Author(s):  
Ohad Cohen ◽  
Jean-Yves Sichel ◽  
Chanan Shaul ◽  
Itay Chen ◽  
J. Thomas Roland ◽  
...  

Although malpositioning of the cochlear implant (CI) electrode array is rare in patients with normal anatomy, when occurring it may result in reduced hearing outcome. In addition to intraoperative electrophysiologic tests, imaging is an important modality to assess correct electrode array placement. The purpose of this report was to assess the incidence and describe cases in which intraoperative plain radiographs detected a malpositioned array. Intraoperative anti-Stenver’s view plain X-rays are conducted routinely in all CI surgeries in our tertiary center before awakening the patient and breaking the sterile field. Data of patients undergoing 399 CI surgeries were retrospectively analyzed. A total of 355 had normal inner ear and temporal bone anatomy. Patients with intra or extracochlear malpositioned electrode arrays demonstrated in the intraoperative X-ray were described. There were four cases of electrode array malposition out of 355 implantations with normal anatomy (1.1%): two tip fold-overs, one extracochlear placement and one partial insertion. All electrodes were reinserted immediately; repeated radiographs were normal and the patients achieved good hearing function. Intraoperative plain anti-Stenver’s view X-rays are valuable to confirm electrode array location, allowing correction before the conclusion of surgery. These radiographs are cheaper, faster, and emit much less radiation than other imaging options, making them a viable cost-effective tool in patients with normal anatomy.


2002 ◽  
Vol 24 (4) ◽  
pp. 105-110 ◽  
Author(s):  
Jarbas J. R. Rohwedder ◽  
Celio Pasquini ◽  
Ivo M. Raimundo, Jr. ◽  
M. Conceiçao ◽  
B. S. M. Montenegro ◽  
...  

A versatile potentiometer that works with electrode arrays in flow injection and/or monosegmented flow systems is described. The potentiometer is controlled by a microcomputer that allows individual, sequential multiplexed or random accesses to eight electrodes while employing only one reference electrode. The instrument was demonstrated by monitoring an array of seven flow-through ion-selective electrodes for Ag+and for three electrodes for Cl-, Ca2+and K+. The figures of merit of the individual and multiplexed (summed) readings of the electrode array were compared. The absolute standard deviation of the measurements made by summing the potential of two or more electrodes was maintained constant, thus improving the precision of the measurements. This result shows that an attempt to combine the signals of the electrodes to produce a more intense signal in the Hadamard strategy is feasible and accompanied by a proportional improvement in the precision of individual measurements. The preliminary tests suggest that the system can allow for 270 determinations per hour, with a linear range from1.0×10−2to1.0×10−4mol l-1for the three di¡erent analytes. Detection limits were estimated as3.1×10−5,3.0×10−6and1.0×10−5mol l-1for Cl-, Ca2+and K+, respectively.


Author(s):  
Brian Dincau ◽  
Arian Aghilinejad ◽  
Jong-Hoon Kim ◽  
Xiaolin Chen

Deterministic lateral displacement (DLD) is a common name given to a class of continuous microfluidic separation devices that use a repeating array of pillars to selectively displace particles having a mean diameter greater than the critical diameter (Dc). This Dc is an emergent property influenced by pillar shape, size, and spacing, in addition to the suspending fluid and target particle properties. The majority of previous research in DLD applications has focused on the utilization of laminar flow in low Reynolds number (Re) regimes. While laminar flow exhibits uniform streamlines and predictable separation characteristics, this low-Re regime is dependent on relatively low fluid velocities, and may not hold true at higher processing speeds. Through numerical modeling and experimentation, we investigated high-Re flow characteristics and potential separation enhancements resulting from vortex generation within a DLD array. We used an analytical model and computational software to simulate DLD performance spanning a Re range of 1–100 at flow rates of 2–170 μL/s (0.15–10 mL/min). Each simulated DLD array configuration was composed of 60 μm cylindrical pillars with a 45 μm gap size. The experimental DLD device was fabricated using conventional soft lithography, and injected with 20 μm particles at varying flow rates to observe particle trajectories. The simulated results predict a shift in Dc at Re > 50, while the experimental results indicate a breakdown of typical DLD operation at Re > 70.


2017 ◽  
Vol 9 (1) ◽  
Author(s):  
Amin Amini ◽  
Hamidreza Ramazi

AbstractThis paper is devoted to the application of the Combined Resistivity Sounding and Profiling electrode configuration (CRSP) to detect underground cavities. Electrical resistivity surveying is among the most favorite geophysical methods due to its nondestructive and economical properties in a wide range of geosciences. Several types of the electrode arrays are applied to detect different certain objectives. In one hand, the electrode array plays an important role in determination of output resolution and depth of investigations in all resistivity surveys. On the other hand, they have their own merits and demerits in terms of depth of investigations, signal strength, and sensitivity to resistivity variations. In this article several synthetic models, simulating different conditions of cavity occurrence, were used to examine the responses of some conventional electrode arrays and also CRSP array. The results showed that CRSP electrode configuration can detect the desired objectives with a higher resolution rather than some other types of arrays. Also a field case study was discussed in which electrical resistivity approach was conducted in Abshenasan expressway (Tehran, Iran) U-turn bridge site for detecting potential cavities and/or filling loose materials. The results led to detect an aqueduct tunnel passing beneath the study area.


2017 ◽  
Vol 132 (3) ◽  
pp. 224-229 ◽  
Author(s):  
P Mittmann ◽  
A Ernst ◽  
I Todt

AbstractBackground:Preservation of residual hearing is one of the major goals in modern cochlear implant surgery. Intra-cochlear fluid pressure changes influence residual hearing, and should be kept low before, during and after cochlear implant insertion.Methods:Experiments were performed in an artificial cochlear model. A pressure sensor was inserted in the apical part. Five insertions were performed on two electrode arrays. Each insertion was divided into three parts, and statistically evaluated in terms of pressure peak frequency and pressure peak amplitude.Results:The peak frequency over each third part of the electrode increased in both electrode arrays. A slight increase was seen in peak amplitude in the lateral wall electrode array, but not in the midscalar electrode array. Significant differences were found in the first third of both electrode arrays.Conclusion:The midscalar and lateral wall electrode arrays have different intra-cochlear fluid pressure changes associated with intra-cochlear placement, electrode characteristics and insertion.


Geophysics ◽  
1999 ◽  
Vol 64 (2) ◽  
pp. 403-416 ◽  
Author(s):  
Douglas W. Oldenburg ◽  
Yaoguo Li

In this paper, the term “depth of investigation” refers generically to the depth below which surface data are insensitive to the value of the physical property of the earth. Estimates of this depth for dc resistivity and induced polarization (IP) surveys are essential when interpreting models obtained from any inversion because structure beneath that depth should not be interpreted geologically. We advocate carrying out a limited exploration of model space to generate a few models that have minimum structure and that differ substantially from the final model used for interpretation. Visual assessment of these models often provides answers about existence of deeper structures. Differences between the models can be quantified into a depth of investigation (DOI) index that can be displayed with the model used for interpretation. An explicit algorithm for evaluating the DOI is presented. The DOI curves are somewhat dependent upon the parameters used to generate the different models, but the results are robust enough to provide the user with a first‐order estimate of a depth region below which the earth structure is no longer constrained by the data. This prevents overinterpretation of the inversion results. The DOI analysis reaffirms the generally accepted conclusions that different electrode array geometries have different depths of penetration. However, the differences between the inverted models for different electrode arrays are far less than differences in the pseudosection images. Field data from the Century deposit are inverted and presented with their DOI index.


2014 ◽  
Vol 5 (1) ◽  
Author(s):  
Dong-Wook Park ◽  
Amelia A. Schendel ◽  
Solomon Mikael ◽  
Sarah K. Brodnick ◽  
Thomas J. Richner ◽  
...  

Abstract Neural micro-electrode arrays that are transparent over a broad wavelength spectrum from ultraviolet to infrared could allow for simultaneous electrophysiology and optical imaging, as well as optogenetic modulation of the underlying brain tissue. The long-term biocompatibility and reliability of neural micro-electrodes also require their mechanical flexibility and compliance with soft tissues. Here we present a graphene-based, carbon-layered electrode array (CLEAR) device, which can be implanted on the brain surface in rodents for high-resolution neurophysiological recording. We characterize optical transparency of the device at >90% transmission over the ultraviolet to infrared spectrum and demonstrate its utility through optical interface experiments that use this broad spectrum transparency. These include optogenetic activation of focal cortical areas directly beneath electrodes, in vivo imaging of the cortical vasculature via fluorescence microscopy and 3D optical coherence tomography. This study demonstrates an array of interfacing abilities of the CLEAR device and its utility for neural applications.


1962 ◽  
Vol 84 (4) ◽  
pp. 447-457 ◽  
Author(s):  
B. T. Arnberg

Critical flowmeters for accurately measuring the mass flow rates of nonreacting real gases were reviewed. Discussions were presented on theoretical flow functions, on parameters for correlating discharge coefficients, and on the importance of real gas properties. The performance characteristics of critical nozzles and orifices of several designs were reviewed. Approaches were discussed to problems which must be researched before the fullest potential of this type of flow measurement can be realized.


2011 ◽  
Vol 254 ◽  
pp. 82-85 ◽  
Author(s):  
Nishant S. Lawand ◽  
P.J. French ◽  
Jeroen J. Briaire ◽  
Johan H.M. Frijns

Cochlear Implant's (CI's) are devices that provides sense of sound to people who are deaf or severely hard of hearing. The important issue with CI's is the electrode design and its placement. The array should be placed close to the modiolar wall of cochlea to stimulate the auditory neurons in accordance with the frequency of the sound and the tonotopic organization of cochlea. It should be flexible for easy surgical insertion and biocompatible enough to withstand the hostile and saline warm environment inside the cochlea. Silicon semiconductor micro-fabrication is an promising technology for advanced CI electrode arrays which will replace the traditional fabrication method. In this paper the design for the silicon electrode array with its consideration is shown. Preliminary simulation results for a stiff probe puncturing the cochlear auditory nerve, which is done to get the stimulation pattern and to realise the mechanical strength of the stiff probe.


Sign in / Sign up

Export Citation Format

Share Document