Isolation of Circulating Tumor Cells Using Stiffness-Based Filtration Platform

Author(s):  
Emrah Celik ◽  
Nicolas Rongione ◽  
Amelia Bahamonde ◽  
Zheng Ao ◽  
Ram Datar

Analysis of isolated cancer cells in circulation is proven to help determine the success of the cancer treatment and understand the genetic signature of cancer disease. Scarcity of these cells in blood circulation (1–10 CTC in 1ml blood) however, makes the isolation process extremely challenging. Ever improving CTC isolation methods fall into two main categories: 1.Immunomagnetic separation based on antibody binding to tumor specific biomarkers expressed on the cell 2. Physical separation based on the size of the CTCs. Efficiency in cell isolation is still low in these techniques due to the variation in expression level of tumor specific antigens and tumor cell size. Therefore, tumor cell isolation strategies using new CTC biomarkers must be explored. In this study, we investigated the feasibility of using mechanical stiffness difference in order to detect and isolate the circulating tumor cells from the blood cells. AFM nanindentation experiments revealed that cancer cells are significantly softer than the surrounding white blood cells and therefore, stiffness can be used as a biomarker for CTC isolation. In addition, finite element analysis simulations have shown that CTC isolation can be performed at high efficiency using stiffness-based isolation. Therefore, stiffness based isolation has a potential to achieve fast, label-free isolation of CTCs at high efficiency for clinical applications.

Micromachines ◽  
2020 ◽  
Vol 11 (5) ◽  
pp. 481 ◽  
Author(s):  
Jusin Lee ◽  
Onejae Sul ◽  
Seung-Beck Lee

Based on their high clinical potential, the isolation and enrichment of rare circulating tumor cells (CTCs) from peripheral blood cells has been widely investigated. There have been technical challenges with CTC separation methods using solely cancer-specific surface molecules or just using physical properties of CTCs, as they may suffer from heterogeneity or lack of specificity from overlapping physical characteristics with leukocytes. Here, we integrated an immunomagnetic-based negative enrichment method that utilizes magnetic beads attached to leukocyte-specific surface antigens, with a physical separation method that utilizes the distinct size and deformability of CTCs. By manipulating the pressure distribution throughout the device and balancing the drag and magnetic forces acting on the magnetically labeled white blood cells (WBCs), the sequential physical and magnetophoretic separations were optimized to isolate intact cancer cells, regardless of heterogeneity from whole blood. Using a breast cancer cell line in whole blood, we achieved 100% separation efficiency for cancer cells and an average of 97.2% for WBCs, which resulted in a 93.3% average separation purity. The experimental results demonstrated that our microfluidic device can be a promising candidate for liquid biopsy and can be a vital tool for aiding future cancer research.


2020 ◽  
Vol 10 (14) ◽  
pp. 4854
Author(s):  
Zahra El-Schich ◽  
Birgit Janicke ◽  
Kersti Alm ◽  
Nishtman Dizeyi ◽  
Jenny L. Persson ◽  
...  

Breast cancer is the second most common cancer worldwide. Metastasis is the main reason for death in breast cancer, and today, there is a lack of methods to detect and isolate circulating tumor cells (CTCs), mainly due to their heterogeneity and rarity. There are some systems that are designed to detect rare epithelial cancer cells in whole blood based on the most common marker used today, the epithelial cell adhesion molecule (EpCAM). It has been shown that aggressive breast cancer metastases are of non-epithelial origin and are therefore not always detected using EpCAM as a marker. In the present study, we used an in vitro-based circulating tumor cell model comprising a collection of six breast cancer cell lines and white blood cell lines. We used digital holographic cytometry (DHC) to characterize and distinguish between the different cell types by area, volume and thickness. Here, we present significant differences in cell size-related parameters observed when comparing white blood cells and breast cancer cells by using DHC. In conclusion, DHC can be a powerful diagnostic tool for the characterization of CTCs in the blood.


2018 ◽  
Vol 23 (1) ◽  
pp. 16-29 ◽  
Author(s):  
Clementine A. Lemaire ◽  
Sean Z. Liu ◽  
Charles L. Wilkerson ◽  
Vishnu C. Ramani ◽  
Nasim A. Barzanian ◽  
...  

Tumor tissue biopsies are invasive, costly, and collect a limited cell population not completely reflective of patient cancer cell diversity. Circulating tumor cells (CTCs) can be isolated from a simple blood draw and may be representative of the diverse biology from multiple tumor sites. The VTX-1 Liquid Biopsy System was designed to automate the isolation of clinically relevant CTC populations, making the CTCs available for easy analysis. We present here the transition from a cutting-edge microfluidic innovation in the lab to a commercial, automated system for isolating CTCs directly from whole blood. As the technology evolved into a commercial system, flexible polydimethylsiloxane microfluidic chips were replaced by rigid poly(methyl methacrylate) chips for a 2.2-fold increase in cell recovery. Automating the fluidic processing with the VTX-1 further improved cancer cell recovery by nearly 1.4-fold, with a 2.8-fold decrease in contaminating white blood cells and overall improved reproducibility. Two isolation protocols were optimized that favor either the cancer cell recovery (up to 71.6% recovery) or sample purity (≤100 white blood cells/mL). The VTX-1’s performance was further tested with three different spiked breast or lung cancer cell lines, with 69.0% to 79.5% cell recovery. Finally, several cancer research applications are presented using the commercial VTX-1 system.


2012 ◽  
Vol 30 (15_suppl) ◽  
pp. 4663-4663
Author(s):  
Amir Goldkorn ◽  
Benjamin Ely ◽  
David I. Quinn ◽  
Catherine M. Tangen ◽  
Yu-Chong Tai ◽  
...  

4663 Background: Analysis of circulating tumor cells (CTC) is a promising biomarker strategy in advanced prostate cancer, and telomerase activity (TA) is a recognized cancer marker. To test whether CTC TA is prognostic for survival (OS), we developed a novel Parylene-C slot microfilter capable of capturing live CTC and used it to measure CTC TA as part of a Phase III SWOG-coordinated therapeutic trial in metastatic castration resistant prostate cancer (S0421). Methods: Blood samples were drawn into EDTA tubes and shipped overnight to a central processing site. After Ficoll centrifugation, low constant pressure was used to pass the mononuclear cell layer through two slot microfilters in series as published previously (filter1 captures CTC + background white blood cells; filter2 captures only background white blood cells). Filter-trapped cells were lysed in CHAPS buffer and assayed for TA using qPCR-based telomeric repeat amplification. In parallel, CTC were enumerated using CellSearch (J&J). Cox regression was used to evaluate the association between baseline (pre-treatment) TA and OS overall, and within subgroups characterized by good prognosis (<5) vs. poor prognosis (>=5) baseline CTC counts. CART regression was used to explore potential prognostic subgroups based on baseline PSA, CTC, and TA cutpoints. Results: Samples were obtained from 263 patients. While no association was observed between TA and OS overall, in patients with baseline CTC >=5 (108 of 263 or 41% of patients), TAfilter2 – TAfilter1 representing high CTC TA relative to background blood cells was associated with a hazard ratio (HR) of 1.14 (95% CI 1.05-1.23, p<0.001) for OS after adjusting for risk factors and remained significant when also adjusting for CTC: HR 1.14 (95% CI 1.04-1.23; p=0.005). Exploratory CART regression assessing baseline PSA, CTC, and TA identified risk groups based only on CTC and TA values. Conclusions: Baseline TA from CTC live-captured on a new slot microfilter is the first CTC biomarker shown to be prognostic of OS in men with CTC counts >=5 in a prospective clinical trial. CTC TA may be useful for further identifying prognostic groups in this population.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Chia-Heng Chu ◽  
Ruxiu Liu ◽  
Tevhide Ozkaya-Ahmadov ◽  
Brandi E. Swain ◽  
Mert Boya ◽  
...  

AbstractReliable and routine isolation of circulating tumor cells (CTCs) from peripheral blood would allow effective monitoring of the disease and guide the development of personalized treatments. Negative enrichment of CTCs by depleting normal blood cells ensures against a biased selection of a subpopulation and allows the assay to be applied on different tumor types. Here, we report an additively manufactured microfluidic device that can negatively enrich viable CTCs from clinically-relevant volumes of unmanipulated whole blood samples. Our device depletes nucleated blood cells based on their surface antigens and the smaller anucleated cells based on their size. Enriched CTCs are made available off the device in suspension making our technique compatible with standard immunocytochemical, molecular and functional assays. Our device could achieve a ~ 2.34-log depletion by capturing > 99.5% of white blood cells from 10 mL of whole blood while recovering > 90% of spiked tumor cells. Furthermore, we demonstrated the capability of the device to isolate CTCs from blood samples collected from patients (n = 15) with prostate and pancreatic cancers in a pilot study. A universal CTC assay that can differentiate tumor cells from normal blood cells with the specificity of clinically established membrane antigens yet require no label has the potential to enable routine blood-based tumor biopsies at the point-of-care.


2018 ◽  
Vol 29 (1) ◽  
pp. 193-199 ◽  
Author(s):  
M. Ilié ◽  
E. Szafer-Glusman ◽  
V. Hofman ◽  
E. Chamorey ◽  
S. Lalvée ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Zhenlong Wang ◽  
Peng Zhang ◽  
Yue Chong ◽  
Yuquan Xue ◽  
Xiaojie Yang ◽  
...  

To explore the clinical significance of the perioperative counts of circulating tumor cells (CTCs), mesenchymal CTCs (MCTCs), and CTC- white blood cells (WBCs) in renal cell carcinoma patients. A total of 131 patients with renal cancer who underwent operation excision from our hospital were enrolled. In addition, 20 patients with benign renal diseases were recruited as a control. Blood samples were collected from the 131 patients, before operation and 3 months after surgery. Samples were also obtained simultaneously from the control group. CanPatrol CTC detection technique was used to enrich and identify CTCs, MCTCs, and CTC-WBCs. All enrolled patients were T1-3N0M0. From these, 52 patients with renal cancer underwent radical resection, while other 79 patients underwent nephron-sparing surgery. The positive rate of CTC, MCTC, and CTC-WBC before surgery were 95.4% (125/131), 61.1% (80/131), and 11.5% (15/131), respectively. Preoperative total CTCs, MCTCs, or CTC-WBCs were poorly correlated with patients’ parameters. Preoperative CTC, MCTC, or CTC-WBC showed no association with progression-free survival (PFS). In contrast, postoperative total CTCs (≥6), positive MCTCs, and positive CTC-WBCs significantly correlated with recurrence and metastasis. These results remained independent indicators for worse PFS. In addition, the increased CTC and MCTC count after surgery also correlated with unfavorable PFS. The detection of six or more total CTCs, MCTC, or CTC-WBCs in peripheral blood after surgery might help to identify a subset of patients that have higher recurrent risk than the overall population of patients with at different stages of renal cancer.


Sign in / Sign up

Export Citation Format

Share Document