Numerical Investigations of Forced Convection From Rectangular Coiled Pipes

Author(s):  
Ibrahima Conte´ ◽  
Xiao-Feng Peng ◽  
Zhen Yang

Investigations are done to numerically study forced convective heat transfer from the flow inside a rectangular coiled pipe, as micro-scale heat exchange device with staggered arrangement, to the external flow around the pipe. The commercial CFD software Fluent 6.0 is used as the solver. The problems considered were three-dimensional laminar flow of the refrigerant R141B through the tube and turbulent air flow exterior to the tube. The studied coiled pipe was composed of four rows among which two rows were encompassed in a large rectangular coil and the other two were in an inner smaller rectangular coil. The results showed remarkable differences in the flow behavior and heat transfer for different rows of tubes. The secondary flow in the tubes bends of the larger rectangular coil is very weak compared to that of the inner rectangular coil. Better heat transfer process occurred through the tubes of the second row where the higher values of the fluid temperatures were observed in the pipe. The results showed the effects of the straight tubes inclination angle on the flow behavior in rectangular coiled pipes. The shape of the secondary flow is changed from a couple of vortices in the case of smaller angle (α = 9°) to a single vortex in the case of larger angle (α = 45°). The results also showed the rotation of the maximum axial velocity due to the increase in the straight tubes inclination angles. The results are in good agreement with previous numerical and experimental works on laminar flow in helical coil pipe.

Author(s):  
Ibrahima Conte ◽  
Zhen Yang ◽  
Xiaofeng Peng

Investigations are done to numerically analyze forced convection from rectangular coiled pipes using commercial CFD software Fluent 6.0. The problems considered were three-dimensional laminar flow with water inside and outside the pipe. Calculations are done for two rectangular coiled pipes of different values of pitch (distance between two adjacent coils centers). The shift of location of the water flow maximum velocity was significantly observed in the case of smaller pitch. It is expected that the higher pitch value reduces the effects of the torsion. The shift of the flow maximum velocity area allows the fluid to be mixed well inside the pipe. For the outside flow, the flow behavior and the heat transfer should be improved by increasing the outside inlet velocity for the case of small pitch.


Author(s):  
Jiehai Zhang ◽  
Arun Muley ◽  
Joseph B. Borghese ◽  
Raj M. Manglik

Enhanced heat transfer characteristics of low Reynolds number airflows in three-dimensional sinusoidal wavy plate-fin channels are investigated. For the computational simulation, steady state, constant property, periodically developed, laminar forced convection is considered with the channel surface at the uniform heat flux condition; the wavy-fin is modeled by its two asymptotic limits of 100% and zero fin efficiency. The governing equations are solved numerically using finite-volume techniques for a non-orthogonal, non-staggered grid. Computational results for velocity and temperature distribution, isothermal Fanning friction factor f and Colburn factor j are presented for airflow rates in the range of 10 ≤ Re ≤ 1500. The numerical results are further compared with experimental data, with excellent agreement, for two different wavy-fin geometries. The influence of fin density on the flow behavior and the enhanced convection heat transfer are highlighted. Depending on the flow rate, a complex flow structure is observed, which is characterized by the generation, spatial growth and dissipation of vortices in the trough region of the wavy channel. The thermal boundary layers on the fin surface are periodically disrupted, resulting in high local heat fluxes. The overall heat transfer performance is improved considerably, compared to the straight channel with the same cross-section, with a relatively smaller increase in the associated pressure drop penalty.


2011 ◽  
Vol 228-229 ◽  
pp. 676-680 ◽  
Author(s):  
Ye Tian ◽  
Xun Liang Liu ◽  
Zhi Wen

A three-dimensional mathematic model is developed for a 100kw single-end recuperative radiant tube and the simulation is performed with the CFD software FLUENT. Also it is used to investigate the effect of distance between combustion chamber exit and inner tube on heat transfer process. The results suggest that the peak value of combustion flame temperature drops along with the increasing of distance, which leads to low NOX discharging. Also radiant tube surface bulk temperature decreases, which causes radiant tube heating performance losses.


Author(s):  
Leila Choobineh ◽  
Dereje Agonafer ◽  
Ankur Jain

Heterogeneous integration in microelectronic systems using interposer technology has attracted significant research attention in the past few years. Interposer technology is based on stacking of several heterogeneous chips on a common carrier substrate, also referred to as the interposer. Compared to other technologies such as System-on-Chip (SoC) or System-in-Package (SiP), interposer-based integration offers several technological advantages. However, the thermal management of an interposer-based system is not well understood. The presence of multiple heat sources in various die and the interposer itself needs to be accounted for in any effective thermal model. While a finite-element based simulation may provide a reasonable temperature prediction tool, an analytical solution is highly desirable for understanding the fundamentals of the heat transfer process in interposers. In this paper, we describe our recent work on analytical modeling of heat transfer in interposer-based microelectronic systems. The basic governing energy conservation equations are solved to derive analytical expressions for the temperature distribution in an interposer-based microelectronic system. These solutions are combined with an iterative approach to provide the three-dimensional temperature field in an interposer. Results are in excellent agreement with finite-element solutions. The analytical model is utilized to study the effect of various parameters on the temperature field in an interposer system. Results from this work may be helpful in the thermal design of microelectronic systems containing interposers.


2005 ◽  
Vol 127 (3) ◽  
pp. 352-356 ◽  
Author(s):  
Michael W. Egner ◽  
Louis C. Burmeister

Laminar flow and heat transfer in three-dimensional spiral ducts of rectangular cross section with aspect ratios of 1, 4, and 8 were determined by making use of the FLUENT computational fluid dynamics program. The peripherally averaged Nusselt number is presented as a function of distance from the inlet and of the Dean number. Fully developed values of the Nusselt number for a constant-radius-of-curvature duct, either toroidal or helical with small pitch, can be used to predict those quantities for the spiral duct in postentry regions. These results are applicable to spiral-plate heat exchangers.


1990 ◽  
Vol 112 (3) ◽  
pp. 488-496 ◽  
Author(s):  
K. Takeishi ◽  
M. Matsuura ◽  
S. Aoki ◽  
T. Sato

The effects of the three-dimensional flow field on the heat transfer and the film cooling on the endwall, suction, and pressure surface of an airfoil were studied using a low speed, fully annular, low aspect h/c = 0.5 vane cascade. The predominant effects on the horseshoe vortex, secondary flow, and nozzle wake of increases in the heat transfer and decreases in the film cooling on the suction vane surface and the endwall were clearly demonstrated. In addition, it was demonstrated that secondary flow has little effect on the pressure surface. Pertinent flow visualization of the flow passage was also carried out for better understanding of these complex phenomena. Heat transfer and film cooling on the fully annular vane passage surface are discussed.


2000 ◽  
Vol 123 (2) ◽  
pp. 274-280 ◽  
Author(s):  
Sang Woo Lee ◽  
Seong Kuk Joo ◽  
Joon Sik Lee

Presented are three-dimensional mean velocity components and aerodynamic loss data inside circular injection holes. The holes are normally oriented to a crossflow and each hole has a sharp square-edged inlet. Because of their importance to flow behavior, three different blowing ratios, M=0.5, 1.0, and 2.0, and three hole length-to-diameter ratios, L/D=0.5, 1.0, and 2.0, are investigated. The entry flow is characterized by a separation bubble, and the exit flow is characterized by direct interaction with the crossflow. The uniform oncoming flow at the inlet undergoes a strong acceleration and a subsequent gradual deceleration along a converging–diverging flow passage formed by the inlet separation bubble. After passing the throat of the converging–diverging passage, the potential core flow, which is nearly axisymmetric, decelerates on the windward side, but tends to accelerate on the leeward side. The presence of the crossflow thus reduces the discharge of the injectant on the windward side, but enhances its efflux on the leeward side. This trend is greatly accentuated at M=0.5. In general, there are strong secondary flows in the inlet and exit planes of the injection hole. The secondary flow within the injection hole, on the other hand, is found to be relatively weak. The inlet secondary flow is characterized by a strong inward flow toward the injection-hole center. However, it is not completely directed inward since the crossflow effect is superimposed on it. Past the throat, secondary flow is observed such that the leeward velocity component induced by the crossflow is superimposed on the diverging flow. Short L/D usually results in an exit discharging flow with a steep velocity gradient as well as a strong deceleration on the windward side, as does low M. The aerodynamic loss inside the injection hole originates from the inlet separation bubble, wall friction and interaction of the injectant with the crossflow. The first one is considered as the most dominant source of loss, even in the case of L/D=2.0. At L/D=0.5, the first and third sources are strongly coupled with each other. Regardless of L/D, the mass-averaged aerodynamic loss coefficient has an increasing tendency with increasing M.


2018 ◽  
Vol 140 (5) ◽  
Author(s):  
Binaya Baidar ◽  
Jonathan Nicolle ◽  
Chirag Trivedi ◽  
Michel J. Cervantes

The Winter-Kennedy (WK) method is commonly used in relative discharge measurement and to quantify efficiency step-up in hydropower refurbishment projects. The method utilizes the differential pressure between two taps located at a radial section of a spiral case, which is related to the discharge with the help of a coefficient and an exponent. Nearly a century old and widely used, the method has shown some discrepancies when the same coefficient is used after a plant upgrade. The reasons are often attributed to local flow changes. To study the change in flow behavior and its impact on the coefficient, a numerical model of a semi-spiral case (SC) has been developed and the numerical results are compared with experimental results. The simulations of the SC have been performed with different inlet boundary conditions. Comparison between an analytical formulation with the computational fluid dynamics (CFD) results shows that the flow inside an SC is highly three-dimensional (3D). The magnitude of the secondary flow is a function of the inlet boundary conditions. The secondary flow affects the vortex flow distribution and hence the coefficients. For the SC considered in this study, the most stable WK configurations are located toward the bottom from θ=30deg to 45deg after the curve of the SC begins, and on the top between two stay vanes.