Normative Spatiotemporal Parameters During 100-m Sprints in Amputee Sprinters Using Running-Specific Prostheses

2016 ◽  
Vol 32 (1) ◽  
pp. 93-96 ◽  
Author(s):  
Hiroaki Hobara ◽  
Wolfgang Potthast ◽  
Ralf Müller ◽  
Yoshiyuki Kobayashi ◽  
Thijs A. Heldoorn ◽  
...  

The aim of this study was to develop a normative sample of step frequency and step length during maximal sprinting in amputee sprinters. We analyzed elite-level 100-m races of 255 amputees and 93 able-bodied sprinters, both men and women, from publicly-available Internet broadcasts. For each sprinter’s run, the average forward velocity, step frequency, and step length over the 100-m distance were analyzed by using the official record and number of steps in each race. The average forward velocity was greatest in able-bodied sprinters (10.04 ± 0.17 m/s), followed by bilateral transtibial (8.77 ± 0.27 m/s), unilateral transtibial (8.65 ± 0.30 m/s), and transfemoral amputee sprinters (7.65 ± 0.38 m/s) in men. Differences in velocity among 4 groups were associated with step length (able-bodied vs transtibial amputees) or both step frequency and step length (able-bodied vs transfemoral amputees). Although we also found that the velocity was greatest in able-bodied sprinters (9.10 ± 0.14 m/s), followed by unilateral transtibial (7.08 ± 0.26 m/s), bilateral transtibial (7.06 ± 0.48 m/s), and transfemoral amputee sprinters (5.92 ± 0.33 m/s) in women, the differences in the velocity among the groups were associated with both step frequency and step length. Current results suggest that spatiotemporal parameters during a 100-m race of amputee sprinters is varied by amputation levels and sex.

2018 ◽  
Vol 42 (6) ◽  
pp. 567-570 ◽  
Author(s):  
Hiroaki Hobara ◽  
Sakiko Saito ◽  
Satoru Hashizume ◽  
Yuta Namiki ◽  
Yoshiyuki Kobayashi

Background and aim: Although Paralympic T42 class Men’s 200 m sprints are currently competed by athletes with bilateral and unilateral transfemoral amputations, there may be performance differences between the groups. This study aimed to compare the spatiotemporal parameters of a 200-m sprint between bilateral and unilateral transfemoral amputees wearing running-specific prostheses. Technique: We analyzed 29 races (nine sprinters) with bilateral or unilateral transfemoral amputations from publicly available Internet broadcasts. For each sprinter’s race, the average speed, step frequency, and step length were calculated using the number of steps in conjunction with the official race time. Discussion: Average speed of bilateral transfemoral amputees was 5.7% greater than in unilateral transfemoral amputees. Bilateral transfemoral amputees exhibited lower step frequency (–8.9%) but longer step length (16.3%) than unilateral transfemoral amputees. Therefore, even in the same Paralympic classification (T42), different spatiotemporal strategies exist between bilateral and unilateral transfemoral amputees wearing running-specific prostheses during 200-m sprints. Clinical relevance Since different spatiotemporal strategies exist between bilateral and unilateral transfemoral amputees during 200-m sprints, our data supports recent revisions of classification rules (1st January, 2018), which each population was allocated into the different classification (T61 and T63, respectively).


2019 ◽  
Vol 70 (1) ◽  
pp. 25-38 ◽  
Author(s):  
Felipe García-Pinillos ◽  
Amador García-Ramos ◽  
Rodrigo Ramírez-Campillo ◽  
Pedro Á. Latorre-Román ◽  
Luis E. Roche-Seruendo

Abstract This study aimed to examine the effect of running velocity on spatiotemporal parameters and lower-body stiffness of endurance runners, and the influence of the performance level on those adaptations. Twenty-two male runners (novice [NR], n = 12, and elite runners [ER], n = 10) performed an incremental running test with a total of 5 different running velocities (10, 12, 14, 16, 18 km/h). Each condition lasted 1 min (30 s acclimatization period, and 30 s recording period). Spatiotemporal parameters were measured using the OptoGait system. Vertical (Kvert) and leg (Kleg) stiffness were calculated according to the sine-wave method. A repeated measures ANOVA (2 x 5, group x velocities) revealed significant adaptations (p < 0.05) to increased velocity in all spatiotemporal parameters and Kvert in both NR and ER. ER showed a greater flight time (FT) and step angle (at 18 km/h) (p < 0.05), longer step length (SL) and lower step frequency (SF) (p < 0.05), whereas no between-group differences were found in contact time (CT) nor in the sub-phases during CT at any speed (p ≥ 0.05). ER also showed lower Kvert values at every running velocity (p < 0.05), and no differences in Kleg (p ≥ 0.05). In conclusion, lower SF and Kvert and, thereby, longer FT and SL, seem to be the main spatiotemporal characteristics of high-level runners compared to their low-level counterparts.


Author(s):  
Alejandro Castillo-Domínguez ◽  
Jerónimo García-Romero ◽  
Joaquín Páez-Moguer ◽  
Tomás Ponce-García ◽  
Miguel Medina-Alcántara ◽  
...  

The purpose of this cross-sectional study was to analyse the relationship of neuromuscular performance and spatiotemporal parameters in 18 adolescent distance athletes (age, 15.5 ± 1.1 years). Using the OptoGait system, the power, rhythm, reactive strength index, jump flying time, and jump height of the squat jump, countermovement jump, and eight maximal hoppings test (HT8max) and the contact time (CT), flying time (FT), step frequency, stride angle, and step length of running at different speeds were measured. Maturity offset was determined based on anthropometric variables. Analysis of variance (ANOVA) of repeated measurements showed a reduction in CT (p < 0.000) and an increase in step frequency, step length, and stride angle (p < 0.001), as the velocity increased. The HT8max test showed significant correlations with very large effect sizes between neuromuscular performance variables (reactive strength index, power, jump flying time, jump height, and rhythm) and both step frequency and step length. Multiple linear regression found this relationship after adjusting spatiotemporal parameters with neuromuscular performance variables. Some variables of neuromuscular performance, mainly in reactive tests, were the predictors of spatiotemporal parameters (CT, FT, stride angle, and VO). Rhythm and jump flying time in the HT8max test and power in the countermovement jump test are parameters that can predict variables associated with running biomechanics, such as VO, CT, FT, and stride angle.


2020 ◽  
Vol 72 (1) ◽  
pp. 39-49
Author(s):  
Felipe García-Pinillos ◽  
Daniel Jerez-Mayorga ◽  
Pedro Á. Latorre-Román ◽  
Rodrigo Ramirez-Campillo ◽  
Fernando Sanz-López ◽  
...  

AbstractThis study aimed to analyse the effects of running velocity on spatiotemporal parameters and step variability in amateur endurance runners, according to sex. A group of 51 males and 46 females performed an incremental running test on a treadmill (10-16 km/h). Spatiotemporal parameters (contact and flight time, step length, step frequency and step angle [CT, FT, SL, SF, SA]) and step variability, in terms of within-participant standard deviation (SD), were recorded through the OptoGait System. The ANOVA showed significant differences in the magnitude of the spatiotemporal parameters as running velocity increased (p < 0.001). It also revealed significant differences in step variability (p < 0.005) over the entire running protocol. Between-sex differences in CT, SL, SL-normalized and SF (p < 0.05, ES = 0.4-0.8) were found. Differences were also found in step variability at high velocities (15-16 km/h), with males showing a greater SD than females. In conclusion, increasing running velocity makes CT shorter, FT and SL longer, and SF and SA greater in amateur endurance runners, changing step variability, regardless of sex. Additionally, some between-sex differences were found in spatiotemporal parameters and step variability.


2017 ◽  
Vol 41 (5) ◽  
pp. 492-497 ◽  
Author(s):  
Hiroaki Hobara ◽  
Wolfgang Potthast ◽  
Ralf Müller ◽  
Yoshiyuki Kobayashi ◽  
Satoru Hashizume ◽  
...  

Background: Although anthropometric factors could influence sprint performance in able-bodied sprinters, little is known about the relationships between these anthropometric factors and sprint performance in amputee sprinters. Objectives: To investigate the relationships between body height and spatiotemporal parameters of 100-m sprints in unilateral transtibial amputee and able-bodied sprinters. Study design: This is a cross-sectional study. Methods: We analyzed elite-level 100-m races of 14 male unilateral transtibial amputee sprinters and 22 male able-bodied sprinters from publicly available Internet broadcasts. For each sprinter’s run, the mean step length and frequency were determined using the number of steps in conjunction with the official race time. Furthermore, body height data for sprinters in both groups were obtained from publicly available resources. Results: Linear relationships were found between body height and mean step length and frequency in able-bodied sprinters, respectively. However, there were no significant relationships between body height and spatiotemporal parameters in transtibial amputee sprinters. Conclusion: The results of this study suggest that the relationship between body height and spatiotemporal parameters during a 100-m sprint is not the same between unilateral transtibial amputees and able-bodied sprinters. Clinical relevance Understanding of the relationship between body height and spatiotemporal parameters during a 100-m sprint would provide important information that could be utilized for evaluating prosthetic sprint performance and coaching.


2018 ◽  
Vol 34 (6) ◽  
pp. 509-513
Author(s):  
Hiroaki Hobara ◽  
Sakiko Saito ◽  
Satoru Hashizume ◽  
Hiroyuki Sakata ◽  
Yoshiyuki Kobayashi

To understand the step characteristics during sprinting in lower-extremity amputees using running-specific prosthesis, each athlete should be investigated individually. Theoretically, sprint performance in a 100-m sprint is determined by both step frequency and step length. The aim of the present study was to investigate how step frequency and step length correlate with sprinting performance in elite unilateral transtibial amputees. By using publicly-available Internet broadcasts, the authors analyzed 88 races from 7 unilateral transtibial amputees. For each sprinter’s run, the average step frequency and step length were calculated using the number of steps and official race time. Based on Pearson’s correlation coefficients between step frequency, step length, and official race time for each individual, the authors classified each individual into 3 groups: step-frequency reliant, step-length reliant, and hybrid. It was found that 2, 2, and 3 sprinters were classified into step-frequency reliant, step-length reliant, and hybrid, respectively. These results suggest that the step frequency or step length reliance during a 100-m sprint is an individual occurrence in elite unilateral transtibial amputees using running-specific prosthesis.


Author(s):  
Felipe García-Pinillos ◽  
José M Chicano-Gutiérrez ◽  
Emilio J Ruiz-Malagón ◽  
Luis E Roche-Seruendo

This study aimed to examine the influence of RunScribe location (i.e. lace shoe vs heel shoe) on the accuracy of spatiotemporal gait characteristics during running by comparing data with a high-speed video analysis system at 1000 Hz. A total of 49 endurance runners performed a running protocol on a treadmill at comfortable velocity. Two systems were used to determine spatiotemporal parameters (i.e. contact time, flight time, step frequency, and step length) during running: high-speed video analysis at 1000 Hz and two different RunScribe placements (i.e. lace shoe vs heel shoe). The pairwise comparisons showed some between-system differences in both lace shoe (contact time: p = 0.009; step frequency: p = 0.001) and heel shoe (flight time: p = 0.006; step frequency: p = 0.010), although the effect sizes were small (effect size < 0.3 in all cases). The intraclass correlation coefficients revealed an almost perfect association between systems for contact time and flight time (intraclass correlation coefficient: 0.85–0.90), and step length and step frequency (intraclass correlation coefficient: 0.96–0.97), regardless of the RunScribe placement. Bland–Altman plots revealed that the lace shoe location yielded smaller systematic bias, random errors, and narrower limits of agreement for spatiotemporal parameters during running, except for SF, which had a higher accuracy in a heel shoe location. The results suggest that RunScribe is a valid system to measure spatiotemporal parameters during running on a treadmill according to a high-speed video analysis at 1000 Hz. In addition, the data indicate that the location of the RunScribe system (lace shoe vs heel shoe) plays an important role on the accuracy of spatiotemporal parameters. The lace shoe placement showed smaller systematic bias, random errors, and narrower limits of agreement for contact time, flight time, and step length, whereas the heel shoe placement was slightly more accurate for the step frequency.


1995 ◽  
Vol 77 (3) ◽  
pp. 851-857 ◽  
Author(s):  
Randall S. Singer ◽  
Lynette A. Hart ◽  
R. Lee Zasloff

66 individuals were given a questionnaire during their initial visit to a veterinary clinic for homeless pet owners. Among the 35 men and 31 women, 32 had been homeless for 6 mo. or less and were termed the acutely homeless subgroup, and 34 had been homeless multiple times or for more than 6 mo. and were termed the chronically homeless subgroup. In responding to the Lexington Attachment to Pets Scale, both men and women participants had significantly higher mean scores on attachment to their pets than did the scale's standardization population. Participants did not differ from the normative sample of adults on the Beck Hopelessness Scale. Both men and women participants stated a preference for being rehoused. 93% of men and 96% of women said that housing would not be acceptable if pets were not allowed. 61% of the men and 33% of the women stated they would be willing to live anywhere pets were allowed except in a shelter Reluctance to live in a shelter was significantly greater among chronically homeless men than other subgroups, and they also had low desire to be rehoused. A majority of the participants had been refused housing because they had pets. Attempts to rehouse homeless individuals who have pets are likely to be unsuccessful unless accommodation for pets is included.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tomoya Ueda ◽  
Haruna Asano ◽  
Kyoko Tsuge ◽  
Kanako Seo ◽  
Motoki Sudo ◽  
...  

AbstractGait maturation in infants develops gradually through several phases. However, external factors such as childrearing practices, especially the wearing of diapers, may affect an infant’s motor development. This study investigated the influence of different bulk stresses on the gait of toddlers wearing a disposable diaper. Twenty-six healthy toddlers (age: 19.2 ± 0.9 months) participated in this study. We measured the joint kinematics (pelvis angle and hip-joint angle) and spatiotemporal parameters (step length and step width) of the toddlers’ gait under four dress conditions (wearing Type A_WET, Type A_DRY, and Type B_WET diapers and naked). Type B_WET had a higher bulk stress than Type A_WET, and Type A_DRY had lower stress than Type A _ WET. Our results indicate that the walk of toddlers when wearing a diaper differs from that when naked. This difference is due to the effect of the bulk of the diaper on the lower limb. A high bulk stress has a greater influence than that of a low bulk stress on joint dynamics and step width. Therefore, our findings suggest that wearing diapers with high bulk stress may inhibit the natural gait patterns of toddlers.


Sign in / Sign up

Export Citation Format

Share Document