scholarly journals Convergent Validity of the Fitbit Charge 2 to Measure Sedentary Behavior and Physical Activity in Overweight and Obese Adults

Author(s):  
Joanne A. McVeigh ◽  
Jennifer Ellis ◽  
Caitlin Ross ◽  
Kim Tang ◽  
Phoebe Wan ◽  
...  

Activity trackers provide real-time sedentary behavior (SB) and physical activity (PA) data enabling feedback to support behavior change. The validity of activity trackers in an obese population in a free-living environment is largely unknown. This study determined the convergent validity of the Fitbit Charge 2 in measuring SB and PA in overweight adults. The participants (n = 59; M ± SD: age = 48 ± 11 years; body mass index = 34 ± 4 kg/m2) concurrently wore a Charge 2 and ActiGraph GT3X+ accelerometer for 8 days. The same waking wear periods were analyzed, and standard cut points for GT3X+ and proprietary algorithms for the Charge 2, together with a daily step count, were used. Associations between outputs, mean difference (MD) and limits of agreement (LOA), and relative differences were assessed. There was substantial association between devices (intraclass correlation coefficients from .504, 95% confidence interval [.287, .672] for SB, to .925, 95% confidence interval [.877, .955] for step count). In comparison to the GT3X+, the Charge 2 overestimated SB (MD = 37, LOA = −129 to 204 min/day), moderate to vigorous PA (MD = 15, LOA = −49 to 79 min/day), and steps (MD = 1,813, LOA = −1,066 to 4,691 steps/day), and underestimated light PA (MD = −32, LOA = −123 to 58 min/day). The Charge 2 may be a useful tool for self-monitoring of SB and PA in an overweight population, as mostly good agreement was demonstrated with the GT3X+. However, there were mean and relative differences, and the implications of these need to be considered for overweight adult populations who are already at risk of being highly sedentary and insufficiently active.

2017 ◽  
Vol 44 (8) ◽  
pp. 1249-1256 ◽  
Author(s):  
Wineke Armbrust ◽  
G.J.F. Joyce Bos ◽  
Jan H.B. Geertzen ◽  
Pieter J.J. Sauer ◽  
Pieter U. Dijkstra ◽  
...  

Objective.(1) To determine convergent validity of an activity diary (AD) and accelerometer (Actical brand/Phillips-Respironics) in measuring physical activity (PA) in children with juvenile idiopathic arthritis (JIA). (2) To determine how many days give reliable results. (3) To analyze effects of correcting accelerometer data for non-wear.Methods.Patients with JIA (8–13 yrs) were recruited from 3 Dutch pediatric rheumatology centers. PA was assessed for 7 days with an AD and accelerometer, and was expressed as mean min/day of rest, light PA (LPA), moderate to vigorous PA (MVPA), and PA level (PAL). To analyze convergent validity, intraclass correlation coefficients (ICC) were calculated and paired sample Student t tests were performed. The required number of days to achieve reliable results was calculated using the Spearman-Brown prophecy formula.Results.Convergent validity between AD and accelerometer was moderate for rest and PAL (ICC 0.41). ICC for LPA and MVPA were < 0.24. AD overestimated PAL and MVPA compared with the accelerometer. Wearing the accelerometer 7–19 days gave reliable PA estimates on group and individual levels. For the AD, 13–36 days were needed. Adjusting accelerometer data for non-wear resulted in a clinically relevant higher mean number of min/day spent in LPA (effect size 1.12), but not in MVPA (effect size 0.44).Conclusion.Convergent validity between AD and accelerometer is moderate to poor. In children with JIA, 1-week assessment with an accelerometer is sufficient to measure PA (all levels) reliably. On an individual level and for clinical use, 3 weeks are required. Additional use of AD enables correction for non-wear of accelerometer data.


Author(s):  
Shohei Yano ◽  
Mohammad Javad Koohsari ◽  
Ai Shibata ◽  
Kaori Ishii ◽  
Levi Frehlich ◽  
...  

Background. Comparability of accelerometers in epidemiological studies is important for public health researchers. This study aimed to compare physical activity (light, LPA; moderate, MPA; and moderate-to-vigorous, MVPA) and sedentary behavior (SB) data collected using two Omron triaxial accelerometer generations (Active style Pro, ASP) among a sample of Japanese workers in a free-living environment. Methods. Thirty active and sedentary workers (24–62 years) wore two types of ASP accelerometers, the HJA-350IT (350IT) and the HJA-750C (750C), simultaneously for seven consecutive days to represent a typical week. The accelerometers estimated daily average step counts and time spent per day in LPA, MPA, and MVPA. If a participant had data for ≥4 days (>10 h/day) it was considered valid. The difference and agreement between the two ASPs were analyzed using a paired t-test, intra-class correlation coefficients (ICC), and a Bland–Altman analysis in total and for each type of worker. Results. Among all workers, the 750C measured significantly (p < 0.05) less SB, MPA, MVPA, and more LPA compared with the 350IT. The agreements in ICC were high (ICC ≥ 0.94). Conclusions. Compared with the 350IT, the newer generation 750C ASP accelerometer may not provide equivalent estimates of activity time, regardless of the type of physical activity.


2018 ◽  
Vol 42 (5) ◽  
pp. 518-526 ◽  
Author(s):  
Elisa S Arch ◽  
Jaclyn M Sions ◽  
John Horne ◽  
Barry A Bodt

Background: Step counts, obtained via activity monitors, provide insight into activity level in the free-living environment. Accuracy assessments of activity monitors are limited among individuals with lower-limb amputations. Objectives: (1) To evaluate the step count accuracy of both monitors during forward-linear and complex walking and (2) compare monitor step counts in the free-living environment. Study design: Cross-sectional study. Methods: Adult prosthetic users with a unilateral transtibial amputation were equipped with StepWatch and FitBit One™. Participants completed an in-clinic evaluation to evaluate each monitor’s step count accuracy during forward linear and complex walking followed by a 7-day step count evaluation in the free-living environment. Results: Both monitors showed excellent accuracy during forward, linear walking (intraclass correlation coefficients = 0.97–0.99, 95% confidence interval = 0.93–0.99; percentage error = 4.3%–6.2%). During complex walking, percentage errors were higher (13.0%–15.5%), intraclass correlation coefficients were 0.88–0.90, and 95% confidence intervals were 0.69–0.96. In the free-living environment, the absolute percentage difference between monitor counts was 25.4%, but the counts had a nearly perfect linear relationship. Conclusion: Both monitors accurately counted steps during forward linear walking. StepWatch appears to be more accurate than FitBit during complex walking but a larger sample size may confirm these findings. FitBit consistently counted fewer steps than StepWatch during free-living walking. Clinical relevance The StepWatch and FitBit are acceptable tools for assessing forward, linear walking for individuals with transtibial amputation. Given the results’ consistenty in the free-living enviorment, both tools may ultimiately be able to be used to count steps in the real world, but more research is needed to confirm these findings.


Author(s):  
Hila Beck ◽  
Riki Tesler ◽  
Sharon Barak ◽  
Daniel Sender Moran ◽  
Adilson Marques ◽  
...  

Schools with health-promoting school (HPS) frameworks are actively committed to enhancing healthy lifestyles. This study explored the contribution of school participation in HPS on students’ health behaviors, namely, physical activity (PA), sedentary behavior, and dieting. Data from the 2018/2019 Health Behavior in School-aged Children study on Israeli adolescents aged 11–17 years were used. Schools were selected from a sample of HPSs and non-HPSs. Between-group differences and predictions of health behavior were analyzed. No between-group differences were observed in mean number of days/week with at least 60 min of PA (HPS: 3.84 ± 2.19 days/week, 95% confidence interval of the mean = 3.02–3.34; non-HPS: 3.93 ± 2.17 days/week, 95% confidence interval of the mean = 3.13–3.38). Most children engaged in screen time behavior for >2 h/day (HPS: 60.83%; non-HPS: 63.91%). The odds of being on a diet were higher among more active children (odds ratio [OR] = 1.20), higher socio-economic status (OR = 1.23), and female (OR = 2.29). HPS did not predict any health behavior. These findings suggest that HPSs did not contribute to health behaviors more than non-HPSs. Therefore, health-promoting activities in HPSs need to be improved in order to justify their recognition as members of the HPS network and to fulfill their mission.


10.2196/18142 ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. e18142
Author(s):  
Ramin Mohammadi ◽  
Mursal Atif ◽  
Amanda Jayne Centi ◽  
Stephen Agboola ◽  
Kamal Jethwani ◽  
...  

Background It is well established that lack of physical activity is detrimental to the overall health of an individual. Modern-day activity trackers enable individuals to monitor their daily activities to meet and maintain targets. This is expected to promote activity encouraging behavior, but the benefits of activity trackers attenuate over time due to waning adherence. One of the key approaches to improving adherence to goals is to motivate individuals to improve on their historic performance metrics. Objective The aim of this work was to build a machine learning model to predict an achievable weekly activity target by considering (1) patterns in the user’s activity tracker data in the previous week and (2) behavior and environment characteristics. By setting realistic goals, ones that are neither too easy nor too difficult to achieve, activity tracker users can be encouraged to continue to meet these goals, and at the same time, to find utility in their activity tracker. Methods We built a neural network model that prescribes a weekly activity target for an individual that can be realistically achieved. The inputs to the model were user-specific personal, social, and environmental factors, daily step count from the previous 7 days, and an entropy measure that characterized the pattern of daily step count. Data for training and evaluating the machine learning model were collected over a duration of 9 weeks. Results Of 30 individuals who were enrolled, data from 20 participants were used. The model predicted target daily count with a mean absolute error of 1545 (95% CI 1383-1706) steps for an 8-week period. Conclusions Artificial intelligence applied to physical activity data combined with behavioral data can be used to set personalized goals in accordance with the individual’s level of activity and thereby improve adherence to a fitness tracker; this could be used to increase engagement with activity trackers. A follow-up prospective study is ongoing to determine the performance of the engagement algorithm.


2021 ◽  
Vol 12 ◽  
Author(s):  
Wei Xia ◽  
William Ho Cheung Li ◽  
Tingna Liang ◽  
Yuanhui Luo ◽  
Laurie Long Kwan Ho ◽  
...  

Objectives: This study conducted a linguistic and psychometric evaluation of the Chinese Counseling Competencies Scale-Revised (CCS-R).Methods: The Chinese CCS-R was created from the original English version using a standard forward-backward translation process. The psychometric properties of the Chinese CCS-R were examined in a cohort of 208 counselors-in-training by two independent raters. Fifty-three counselors-in-training were asked to undergo another counseling performance evaluation for the test-retest. The confirmatory factor analysis (CFA) was conducted for the Chinese CCS-R, followed by internal consistency, test-retest reliability, inter-rater reliability, convergent validity, and concurrent validity.Results: The results of the CFA supported the factorial validity of the Chinese CCS-R, with adequate construct replicability. The scale had a McDonald's omega of 0.876, and intraclass correlation coefficients of 0.63 and 0.90 for test-retest reliability and inter-rater reliability, respectively. Significantly positive correlations were observed between the Chinese CCS-R score and scores of performance checklist (Pearson's γ = 0.781), indicating a large convergent validity, and knowledge on drug abuse (Pearson's γ = 0.833), indicating a moderate concurrent validity.Conclusion: The results support that the Chinese CCS-R is a valid and reliable measure of the counseling competencies.Practice implication: The CCS-R provides trainers with a reliable tool to evaluate counseling students' competencies and to facilitate discussions with trainees about their areas for growth.


2018 ◽  
Vol 15 (5) ◽  
pp. 331-337
Author(s):  
Rafaela Costa Martins ◽  
Luiza Isnardi Cardoso Ricardo ◽  
Gerfeson Mendonça ◽  
Daiana Lopes de Rosa ◽  
Letícia Lemos Ayres da Gama Bastos ◽  
...  

Objective: To evaluate trends in physical activity and sedentary behavior simultaneity among Brazilian students from 2009 to 2015 and its association with independent variables. Methods: This study presents a panel of 3 cross-sectional studies carried out in 2009, 2012, and 2015 (Pesquisa Nacional de Saúde do Escolar—PeNSE). The population was comprised of ninth-grade public and private schools students from Brazilian capitals. Physical activity and sedentary behavior variables were combined to create the outcome of simultaneity of these risk factors. Results: A large proportion of students were simultaneously inactive and sedentary in the 3 surveys. However, it was possible to observe a downward trend (2009: 56.4%; 95% confidence interval, 55.7–57.1; 2012: 53.7%; 95% confidence interval, 53.0–54.4; 2015: 51.9%; 95% confidence interval, 51.2–52.7). In 2015, estimates of physical inactivity and sedentary behavior simultaneity were greater than 48% for 20 out of 27 of the Brazilian states. Significant declining trends were observed among mideast residents, females, nonwhite, and those attending private schools. Only around 5%–7% of the adolescents were both active and nonsedentary in the 3 surveys. Conclusion: Despite of a slight decreasing trend in the proportion of Brazilian students simultaneously inactive and sedentary throughout the period, the prevalence remained elevated across the surveys.


2021 ◽  
Author(s):  
Kaja Kastelic ◽  
Marina Dobnik ◽  
Stefan Loefler ◽  
Christian Hofer ◽  
Nejc Šarabon

BACKGROUND Wrist worn consumer-grade activity trackers are popular devices, developed mainly for personal use, but with the potential to be used also for clinical and research purposes. OBJECTIVE The objective of this study was to explore the validity, reliability and sensitivity to change of movement behaviours metrics from three popular activity trackers (POLAR Vantage M, Garmin Vivosport and Garmin Vivoactive 4s) in controlled and free-living conditions when worn by older adults. METHODS Participants (n = 28; 74 ± 5 years) underwent a videotaped laboratory protocol while wearing all three activity trackers. On a separate occasion, participants wore one (randomly assigned) activity tracker and a research grade physical activity monitor ActiGraph wGT3X-BT simultaneously for six consecutive days for comparisons. RESULTS Both Garmin activity trackers showed excellent performance for step counts, with mean absolute percentage error (MAPE) below 20 % and intraclass correlation coefficient (ICC2,1) above 0.90 (P < .05), while Polar Vantage M substantially over counted steps (MAPE = 84 % and ICC2,1 = 0.37 for free-living conditions). MAPE for sleep time was within 10 % for all the trackers tested, while far beyond 20 % for all the physical activity and calories burned outputs. Both Garmin trackers showed fair agreement (ICC2,1 = 0.58–0.55) for measuring calories burned when compared with ActiGraph. CONCLUSIONS Garmin Vivoactive 4s showed overall best performance, especially for measuring steps and sleep time in healthy older adults. Minimal detectible change was consistently lower for an average day measures than for a single day measure, but still relatively high. The results provided in this study could be used to guide choice on activity trackers aiming for different purposes – individual use/care, longitudinal monitoring or in clinical trial setting.


2019 ◽  
Vol 33 (5) ◽  
pp. 936-942 ◽  
Author(s):  
Jayne Lesley Anderson ◽  
L Samantha Yoward ◽  
Angela J Green

Objective: To determine the validity of the ActiGraph GT3X accelerometer in step count quantification when compared to observed step count in hospitalised adults recovering from critical illness. Setting: Large National Health Service (NHS) Hospitals Trust. Subjects: In total, 20 hospital ward-based adults (age: mean 62.3, SD 11.5) who had required greater than 48 hours of mechanical ventilation in the intensive care unit. Main measures: Participants walked self-selected distances and speeds as part of a semi-structured movement protocol not exceeding 3 hours. Two ActiGraph GT3X accelerometers were worn, one on the thigh and one on the ankle of the non-dominant leg. Accelerometer-recorded step counts were compared against observed step counts. Results: In total, 31 separate walking episodes were analysed. A mean (SD) of 45.87 (±19.72) steps was calculated for observed step count (range 15–90). Mean differences (95% limits of agreement) of −0.84 steps (−3.88 to 2.2) for the ankle placement and −17.7 steps (−40.63 to 5.25) for the thigh were calculated. Intraclass correlation coefficients (95% confidence intervals) of 0.99 (0.99 to 1.0) and 0.46 (−0.1 to 0.78) were determined for the ankle and thigh, respectively. Placement sites were well tolerated by 95% of participants. Conclusion: An ankle-mounted ActiGraph GT3X accelerometer demonstrates validity in quantification of step count in hospitalised adults recovering from critical illness. A thigh placement was not considered valid.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Hannah M. L. Young ◽  
Mark W. Orme ◽  
Yan Song ◽  
Maurice Dungey ◽  
James O. Burton ◽  
...  

Abstract Background Physical activity (PA) is exceptionally low amongst the haemodialysis (HD) population, and physical inactivity is a powerful predictor of mortality, making it a prime focus for intervention. Objective measurement of PA using accelerometers is increasing, but standard reporting guidelines essential to effectively evaluate, compare and synthesise the effects of PA interventions are lacking. This study aims to (i) determine the measurement and processing guidance required to ensure representative PA data amongst a diverse HD population, and; (ii) to assess adherence to PA monitor wear amongst HD patients. Methods Clinically stable HD patients from the UK and China wore a SenseWear Armband accelerometer for 7 days. Step count between days (HD, Weekday, Weekend) were compared using repeated measures ANCOVA. Intraclass correlation coefficients (ICCs) determined reliability (≥0.80 acceptable). Spearman-Brown prophecy formula, in conjunction with a priori ≥  80% sample size retention, identified the minimum number of days required for representative PA data. Results Seventy-seven patients (64% men, mean ± SD age 56 ± 14 years, median (interquartile range) time on HD 40 (19–72) months, 40% Chinese, 60% British) participated. Participants took fewer steps on HD days compared with non-HD weekdays and weekend days (3402 [95% CI 2665–4140], 4914 [95% CI 3940–5887], 4633 [95% CI 3558–5707] steps/day, respectively, p < 0.001). PA on HD days were less variable than non-HD days, (ICC 0.723–0.839 versus 0.559–0.611) with ≥ 1 HD day and ≥  3 non-HD days required to provide representative data. Using these criteria, the most stringent wear-time retaining ≥ 80% of the sample was ≥7 h. Conclusions At group level, a wear-time of ≥7 h on ≥1HD day and ≥ 3 non-HD days is required to provide reliable PA data whilst retaining an acceptable sample size. PA is low across both HD and non- HD days and future research should focus on interventions designed to increase physical activity in both the intra and interdialytic period.


Sign in / Sign up

Export Citation Format

Share Document