The Reliability of an Isokinetic Knee Muscle Endurance Test in Young Children

2003 ◽  
Vol 15 (3) ◽  
pp. 313-323 ◽  
Author(s):  
Mark B.A. De Ste Croix ◽  
Neil Armstrong ◽  
Joanne R. Welsman

The purpose of this study was to examine the reliability of repeated isokinetic knee extension and flexion in young children and to examine sex differences in 30 untrained subjects (16 boys and 14 girls) aged 12.2 ± 0.3 years. Total work and the percentage decline in average torque and work were recorded during 50 repetitions. Intra-class correlation coefficients indicated a strong positive correlation between test 1 and 2 for all parameters ranging from 0.36–0.95. Coefficient of variation data ranged from ± 0% to ± 5.4%. Repeatability coefficients and limits of agreement indicated that the extensors were more reliable than the flexors for both torque and work. There were no significant sex differences in any of the parameters measured. This study suggests that repeated isokinetic muscle actions of the knee, as a function of muscle endurance, can be reliably assessed in young people.

2020 ◽  
Vol 8 ◽  
pp. 205031212092382
Author(s):  
Meric Unal ◽  
Sabriye Ercan ◽  
Aydin Budeyri ◽  
Uğur Toprak ◽  
Abdülkerim Şalkaci

Aim: The aim of this study was to derive a pure, unbiased, reliable and accurate objective relationship between the local knee axis measurements through a short knee anteroposterior roentgenogram and the lower limb axis measurement through an orthoroentgenogram. Patients and Methods: Radiographs of 114 patients (114 knees) were evaluated by two independent raters for measurement of lower limb axis on an orthoroentgenogram and the local knee axis on short knee anteroposterior X-ray, which was derived by cropping the orthoroentgenogram by a blinded radiology assistant. The raters measured at two different time-points separated by an interval of 30-day period. Intra-rater and inter-rater reliabilities were calculated by intra-class correlation coefficients and three models were built to establish the relationships of X-ray anatomical axis with orthoroentgenogram anatomical axis, orthoroentgenogram anatomical axis with orthoroentgenogram mechanical axis and X-ray anatomical axis with orthoroentgenogram mechanical axis. Results: For three different measurements, intra-class correlation coefficients of Rater 2 were higher than 0.90 which shows perfect reliability, while that for Rater 1 was low. Furthermore, first measurements were more consistent than the second measurement. There was a strong positive correlation in all the three models except for varus cases in the last. Conclusion: The standardized correlation derived between the two different techniques for measuring knee alignment is fairly comparable with the studies in the past and would serve as a reliable template for future studies concerning relationships between the two, in addition to helping knee surgeons make more reliable and accurate interpretations through local knee axis measurements.


2019 ◽  
Vol 26 (5) ◽  
pp. 1-8
Author(s):  
Gyu-wan Lee ◽  
Chung-hwi Yi ◽  
Gyoung-mo Kim ◽  
Young-jung Lee ◽  
Jang-whon Yoon

Background and aim The Work Osteoarthritis or joint-Replacement Questionnaire (WORQ) is a new assessment tool developed in the Netherlands. It needs translation and cross-cultural adaptation for use in each country. The aim of this study was to translate the Work Osteoarthritis or joint-Replacement Questionnaire into Korean and to verify its reliability and validity. Methods To evaluate the clinimetric quality of the Korean-WORQ, we performed tests for internal consistency (Cronbach's alpha), reliability (intra-class correlation coefficients) and concurrent validity (Spearman's correlation coefficient). Factor analysis was carried out to identify the principal components of the questionnaire. Findings Both the internal consistency and intra-class correlation coefficients showed the reliability of the Korean-WORQ to be excellent. The Korean-WORQ had a strong positive correlation with the Western Ontario and McMaster Universities Osteoarthritis Index and three components were extracted in factor analysis. Conclusions Based on these results, the Korean-WORQ seems to be a suitable questionnaire for assessing the disability levels of patients with knee injuries.


2009 ◽  
Vol 34 (4) ◽  
pp. 725-731 ◽  
Author(s):  
Mark B.A. De Ste Croix ◽  
Martine A. Deighan ◽  
Sebastien Ratel ◽  
Neil Armstrong

The purpose of this study was to examine the age- and sex-associated differences of repeated isokinetic knee extension and flexion. Fifty one participants, 30 young children (16 boys and 14 girls; aged 11 and 12 years) and 21 adults (9 males and 12 females; aged 18–35 years), agreed to participate in the study. Isokinetic concentric peak knee extension (PET) and flexion (PFT) torque were measured using a calibrated Biodex System 3. Participants performed 4 concentric extension–flexion cycles with maximum effort; after a 2 min rest, 50 continuous concentric cycles were performed at 1.56 rad·s–1. Total work of the extensors (WKEX) and flexors (WKFL) for the complete 50 repetitions was recorded. Average peak torque and average work for the first and last 3 repetitions were calculated to represent the percentage decline in torque and work. There were no significant differences between groups in the peak torque generated during the pretrial and endurance task, suggesting that participants gave a maximal effort at the start of the endurance task. There was a significant interaction effect in the total work done for both extensors and flexors, with adult males producing the greatest amount of work (6622 and 3444 J, respectively). When total work was divided by body mass, there were no significant sex effects, only main effects for group. The percentage decline for PET (40% vs. 60%), PFT (50% vs. 65%), WKET (43% vs. 61%), and WKFL (60% vs. 69%) demonstrated significant main effects for group, with greater fatigue in adults. We found no significant sex effect for fatigue. This study concludes that females do not resist fatigue from repeated isokinetic muscle actions to a greater extent than males, and that the greater fatigue in adults than in children is probably a product of greater initial torque production and work performed.


Author(s):  
Serdar Uslu ◽  
Ensar Abazović ◽  
Indira Mahmutović ◽  
Barak Riza

The purpose of this study was to evaluate the relationship between knee extensor and flexor muscles strength and vertical jump in professional female volleyball players. Forty-one female volleyball players participated in this study. Isokinetic PT and was measured at 60°/s, whilst CMJ performance using a force plate. The participants were later divided to WG (weaker group - PT/BW<2) and SG (stronger group - PT/BW>2). Isokinetic concentric knee extension and flexion PT was significantly correlated with CMJ performance. However, higher correlation coefficients were obtained at the non-dominant leg. No significant differences were found but mere trend favoring non-dominant leg muscles in the weaker group. Strong positive correlation exists between isokinetic knee PT and CMJ height in professional female volleyball players. When divided and compared to WG and SG the results indicate weaker players tend to modify their technique individually and towards unilaterality as so they could maximize their performance.


2010 ◽  
Vol 01 (05) ◽  
pp. 219-226 ◽  
Author(s):  
F. Beyer ◽  
B. Buerke ◽  
J. Gerss ◽  
K. Scheffe ◽  
M. Puesken ◽  
...  

SummaryPurpose: To distinguish between benign and malignant mediastinal lymph nodes in patients with NSCLC by comparing 2D and semiautomated 3D measurements in FDG-PET-CT.Patients, material, methods: FDG-PET-CT was performed in 46 patients prior to therapy. 299 mediastinal lymph-nodes were evaluated independently by two radiologists, both manually and by semi-automatic segmentation software. Longest-axial-diameter (LAD), shortest-axial-diameter (SAD), maximal-3D-diameter, elongation and volume were obtained. FDG-PET-CT and clinical/FDG-PET-CT follow up examinations and/or histology served as the reference standard. Statistical analysis encompassed intra-class-correlation-coefficients and receiver-operator-characteristics-curves (ROC). Results: The standard of reference revealed involvement in 87 (29%) of 299 lymph nodes. Manually and semi-automatically measured 2D parameters (LAD and SAD) showed a good correlation with mean


Life ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 75
Author(s):  
Stefanie M. P. Kouwenhoven ◽  
Nadja Antl ◽  
Jos W. R. Twisk ◽  
Berthold V. Koletzko ◽  
Martijn J. J. Finken ◽  
...  

Background: Traditionally, fat mass is estimated using anthropometric models. Air-displacement plethysmography (ADP) is a relatively new technique for determining fat mass. There is limited information on the agreement between these methods in infants and young children. Therefore we aimed to longitudinally compare fat mass percentage values predicted from skinfold thicknesses (SFTs) and ADP in healthy infants and young children. Methods: Anthropometry and body composition were determined at the ages of 1, 4, and 6 months and 2 years. We quantified the agreement between the two methods using the Bland–Altman procedure, linear mixed-model analysis, and intra-class correlation coefficients (ICC). Results: During the first 6 months of life, fat mass% predicted with SFT was significantly different from that measured with ADP in healthy, term-born infants (n = 245). ICCs ranged from 0.33 (at 2 years of age) and 0.47 (at 4 months of age). Although the mean difference (bias) between the methods was low, the Bland–Altman plots showed proportional differences at all ages with wide limits of agreement. Conclusions: There is poor agreement between ADP and SFTs for estimating fat mass in infancy or early childhood. The amount of body fat was found to influence the agreement between the methods.


2015 ◽  
Vol 116 (9/10) ◽  
pp. 564-577 ◽  
Author(s):  
RISHABH SHRIVASTAVA ◽  
Preeti Mahajan

Purpose – The purpose of this paper is twofold. First, the study aims to investigate the relationship between the altmetric indicators from ResearchGate (RG) and the bibliometric indicators from the Scopus database. Second, the study seeks to examine the relationship amongst the RG altmetric indicators themselves. RG is a rich source of altmetric indicators such as Citations, RGScore, Impact Points, Profile Views, Publication Views, etc. Design/methodology/approach – For establishing whether RG metrics showed the same results as the established sources of metrics, Pearson’s correlation coefficients were calculated between the metrics provided by RG and the metrics obtained from Scopus. Pearson’s correlation coefficients were also calculated for the metrics provided by RG. The data were collected by visiting the profile pages of all the members who had an account in RG under the Department of Physics, Panjab University, Chandigarh (India). Findings – The study showed that most of the RG metrics showed strong positive correlation with the Scopus metrics, except for RGScore (RG) and Citations (Scopus), which showed moderate positive correlation. It was also found that the RG metrics showed moderate to strong positive correlation amongst each other. Research limitations/implications – The limitation of this study is that more and more scientists and researchers may join RG in the future, therefore the data may change. The study focuses on the members who had an account in RG under the Department of Physics, Panjab University, Chandigarh (India). Perhaps further studies can be conducted by increasing the sample size and by taking a different sample size having different characteristics. Originality/value – Being an emerging field, not much has been conducted in the area of altmetrics. Very few studies have been conducted on the reach of academic social networks like RG and their validity as sources of altmetric indicators like RGScore, Impact Points, etc. The findings offer insights to the question whether RG can be used as an alternative to traditional sources of bibliometric indicators, especially with reference to a rapidly developing country such as India.


1991 ◽  
Vol 66 (1) ◽  
pp. 3-15 ◽  
Author(s):  
M. G. O'Donnell ◽  
M. Nelson ◽  
P. H. Wise ◽  
D. M. Walker

A diet questionnaire was developed in association with a computer program to provide rapid nutritional feedback to the general public. The questionnaire was validated against 16 d of weighed diet records and biochemical variables in blood and urine. The highest Pearson correlation coefficients obtained between the questionnaire and the weighed records were for alcohol, fibre, iron, riboflavin (r 0.74, 0.67, 0.66, 0.66 respectively). Striking sex differences were shown in the results; the trend for higher correlations persisted in females. At least 65% of subjects were classified by questionnaire to within one quintile of the classification by weighed record for the majority of nutrients.


2006 ◽  
Vol 18 (3) ◽  
pp. 374-384 ◽  
Author(s):  
Andrew S. Cole ◽  
Megan E. Woodruff ◽  
Mary P. Horn ◽  
Anthony D. Mahon

Relationships between physiological parameters and 5-km running performance were examined in 15 male runners (17.3 ± 0.9 years). Running economy (RE) and blood lactate concentration ([BLa]) at 241.2 m/min, VO2max, velocity at VO2max (vVO2max), vertical jump height and muscle power, and isokinetic knee extension strength at 60°/sec and 240°/sec were measured. The participants’ best 5-km race time over the last month of the cross-country season (16.98 ± 0.76 min) was used in the analysis. The data were analyzed using Pearson correlation coefficients. Significant relationships to run time were observed for VO2max (r = -.53), RE (r = .55), and vVO2max (r = -.66), but not [BLa], isokinetic muscle torque, or vertical jump. Identifying the unique strength and power characteristics related to running performance in this age group is warranted.


Medicina ◽  
2021 ◽  
Vol 57 (3) ◽  
pp. 246
Author(s):  
Jesús Requena-García ◽  
Evelyn García-Nieto ◽  
David Varillas-Delgado

Background and Objectives: The techniques directed to the cranial field in osteopathy are the most questioned due to the lack of scientific evidence. In osteopathic practice, manual palpation is essential and, therefore, measuring reliability is fundamental. The objective of this study is to assess the precision and objectification of an educational model in cranial osteopathy based on experience. Materials and Methods: A reliability study was conducted in a cadaver skull where a strain gauge was placed on the sphenobasilar synchondrosis (SBS) of the base of the skull. Three cranial osteopathic techniques (lateral compression, anteroposterior compression, and compression maneuver of the mastoids) were performed 25 times by osteopaths with different degrees of experience (5–10 years, 1–5 years, <1 year). Measurements were computed for each of the three techniques of each group in comparison with the osteopath with >15 years of experience. Data were analyzed to check for inter- and intra-observer reliability using intra-class correlation coefficients (ICC). Results: Reliability in osteopaths with 5–10 years’ experience (observer 1 and observer 2) performing all three techniques was higher (p < 0.001) than the osteopath with >15 years’ experience. Little or no reliability were observed in osteopaths with less experience. Conclusions: The experience of the osteopaths determines the reliability and effectiveness of the cranial techniques, a fundamental part in objectifying these techniques. This model can help implement objective training in cranial osteopathy formation.


Sign in / Sign up

Export Citation Format

Share Document