scholarly journals Bedside hyperspectral imaging for the evaluation of microcirculatory alterations in perioperative intensive care medicine: a study protocol for an observational clinical pilot study (HySpI-ICU)

BMJ Open ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. e035742 ◽  
Author(s):  
Maximilian Dietrich ◽  
Sebastian Marx ◽  
Thomas Bruckner ◽  
Felix Nickel ◽  
Beat Peter Müller-Stich ◽  
...  

IntroductionNormalisation of macrocirculatory parameters during resuscitation therapy does not guarantee the restoration of microcirculatory perfusion in critical illness due to haemodynamic incoherence. Persistent microcirculatory abnormalities are associated with severity of organ dysfunction and mandate the development of bedside microcirculatory monitoring. A novel hyperspectral imaging (HSI) system can visualise changes in skin perfusion, oxygenation and water content at the bedside. We aim to evaluate the effectiveness of HSI for bedside monitoring of skin microcirculation and the association of HSI parameters with organ dysfunction in patients with sepsis and major abdominal surgery.Methods and analysisThree independent groups will be assessed and separately analysed within a clinical prospective observational study: (1) 25 patients with sepsis or septic shock (according to sepsis-3 criteria), (2) 25 patients undergoing pancreatic surgery and (3) 25 healthy controls. Patients with sepsis and patients undergoing pancreatic surgery will receive standard therapy according to local protocols derived from international guidelines. In addition, cardiac output of perioperative patients and patients with sepsis will be measured. Healthy controls undergo one standardised evaluation. The TIVITA Tissue System is a novel HSI system that uses the visible and near-infrared spectral light region to determine tissue microcirculatory parameters. HSI analysis (hand/knee) will be done in parallel to haemodynamic monitoring within defined intervals during a 72-hour observation period. HSI data will be correlated with the Sequential Organ Failure Assessment score, global haemodynamics, inflammation and glycocalyx markers, surgical complications and 30-day outcome.Ethics and disseminationThe protocol has been approved by the local ethics committee of the University of Heidelberg (S-148/2019). Study results will be submitted to peer-reviewed journals and medical conferences.Trial registration numberDRKS00017313; Pre-results.

2016 ◽  
Vol 849 ◽  
pp. 725-731 ◽  
Author(s):  
Xiao Juan Feng ◽  
Qian Jin Mao ◽  
Qiu Rui Lv ◽  
Zi Ming Wang ◽  
Su Ping Cui

Near-infrared pigment is the key to control the near-infrared performance of solar heat-reflective coating which has good economic and application prospects as a new special coating. Green infrared reflective pigments were prepared through physical mixing, inorganic lake method and sol-gel processes in this study. Results show that the near-infrared spectral reflectance of composite pigments is improved when using inorganic lake method and sol-gel method. Chromaticity of composite pigment is the closest to phthalocyanine green when using sol-gel method. Physically mixing method is not suitable to prepare infrared reflective pigment. The coating materials have influence on the coating effect and the reflectivity of near-infrared spectral range in a certain extent.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Maximilian Dietrich ◽  
Sebastian Marx ◽  
Maik von der Forst ◽  
Thomas Bruckner ◽  
Felix C. F. Schmitt ◽  
...  

Abstract Background Hyperspectral imaging (HSI) could provide extended haemodynamic monitoring of perioperative tissue oxygenation and tissue water content to visualize effects of haemodynamic therapy and surgical trauma. The objective of this study was to assess the capacity of HSI to monitor skin microcirculation and possible relations to perioperative organ dysfunction in patients undergoing pancreatic surgery. Methods The hyperspectral imaging TIVITA® Tissue System was used to evaluate superficial tissue oxygenation (StO2), deeper layer tissue oxygenation (near-infrared perfusion index (NPI)), haemoglobin distribution (tissue haemoglobin index (THI)) and tissue water content (tissue water index (TWI)) in 25 patients undergoing pancreatic surgery. HSI parameters were measured before induction of anaesthesia (t1), after induction of anaesthesia (t2), postoperatively before anaesthesia emergence (t3), 6 h after emergence of anaesthesia (t4) and three times daily (08:00, 14:00, 20:00 ± 1 h) at the palm and the fingertips until the second postoperative day (t5–t10). Primary outcome was the correlation of HSI with perioperative organ dysfunction assessed with the perioperative change of SOFA score. Results Two hundred and fifty HSI measurements were performed in 25 patients. Anaesthetic induction led to a significant increase of tissue oxygenation parameters StO2 and NPI (t1–t2). StO2 and NPI decreased significantly from t2 until the end of surgery (t3). THI of the palm showed a strong correlation with haemoglobin levels preoperatively (t2:r = 0.83, p < 0.001) and 6 h postoperatively (t4: r = 0.71, p = 0.001) but not before anaesthesia emergence (t3: r = 0.35, p = 0.10). TWI of the palm and the fingertip rose significantly between pre- and postoperative measurements (t2–t3). Higher blood loss, syndecan level and duration of surgery were associated with a higher increase of TWI. The perioperative change of HSI parameters (∆t1–t3) did not correlate with the perioperative change of the SOFA score. Conclusion This is the first study using HSI skin measurements to visualize tissue oxygenation and tissue water content in patients undergoing pancreatic surgery. HSI was able to measure short-term changes of tissue oxygenation during anaesthetic induction and pre- to postoperatively. TWI indicated a perioperative increase of tissue water content. Perioperative use of HSI could be a useful extension of haemodynamic monitoring to assess the microcirculatory response during haemodynamic therapy and major surgery. Trial registration German Clinical Trial Register, DRKS00017313 on 5 June 2019


Author(s):  
A. Polak ◽  
T. Kelman ◽  
P. Murray ◽  
S. Marshall ◽  
D. Stothard ◽  
...  

Art authentication is a complicated process that often requires the extensive study of high value objects. Although a series of non-destructive techniques is already available for art scientists, new techniques, extending current possibilities, are still required. In this paper, the use of a novel mid-infrared tunable imager is proposed as an active hyperspectral imaging system for art work analysis. The system provides access to a range of wavelengths in the electromagnetic spectrum (2500–3750 nm) which are otherwise difficult to access using conventional hyperspectral imaging (HSI) equipment. The use of such a tool could be beneficial if applied to the paint classification problem and could help analysts map the diversity of pigments within a given painting. The performance of this tool is demonstrated and compared with a conventional, off-the-shelf HSI system operating in the near infrared spectral region (900–1700 nm). Various challenges associated with laser-based imaging are demonstrated and solutions to these challenges as well as the results of applying classification algorithms to datasets captured using both HSI systems are presented. While the conventional HSI system provides data in which more pigments can be accurately classified, the result of applying the proposed laser-based imaging system demonstrates the validity of this technique for application in art authentication tasks.


Materials ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 3848
Author(s):  
Lisa Ptacek ◽  
Alfred Strauss ◽  
Barbara Hinterstoisser ◽  
Andreas Zitek

The curing of concrete significantly influences the hydration process and its strength development. Inadequate curing leads to a loss of quality and has a negative effect on the durability of the concrete. Usually, the effects are not noticed until years later, when the first damage to the structure occurs because of the poor concrete quality. This paper presents a non-destructive measurement method for the determination of the curing quality of young concrete. Hyperspectral imaging in the near infrared is a contactless method that provides information about material properties in an electromagnetic wavelength range that cannot be seen with the human eye. Laboratory tests were carried out with samples with three different curing types at the age of 1, 7, and 27 days. The results showed that differences in the near infrared spectral signatures can be determined depending on the age of the concrete and the type of curing. The data was classified and analyzed by evaluating the results using k-means clustering. This method showed a high level of reliability for the differentiation between the different curing types and concrete ages. A recommendation for hyperspectral measurement and the evaluation of the curing quality of concrete could be made.


2020 ◽  
Vol 25 (08) ◽  
Author(s):  
Hannes Köhler ◽  
Axel Kulcke ◽  
Marianne Maktabi ◽  
Yusef Moulla ◽  
Boris Jansen-Winkeln ◽  
...  

2005 ◽  
Vol 15 (4) ◽  
pp. 859-863 ◽  
Author(s):  
Lee Johnson ◽  
Thibaut Scholasch

Airborne multispectral image data were compared with intercepted photosynthetic photon flux (PPF) in commercial winegrape (Vitis vinifera) vineyards of Napa Valley, Calif. An empirically based calibration was applied to transform raw image pixel values to surface reflectance. Reflectance data from the red and near-infrared spectral regions were combined into a normalized difference vegetation index. Strong linear response was observed between the vegetation index and PPF interception ranging from 0.15 to 0.50. Study results suggest the possibility of using optical remote sensing to monitor and map vineyard shaded area, thus providing spatially explicit input to water budget models that invoke evapotranspiration crop coefficient based calculations.


2021 ◽  
Vol 11 (24) ◽  
pp. 11987
Author(s):  
Soo Chung ◽  
Seung-Chul Yoon

Foreign material (FM) found on a poultry product lowers the quality and safety of the product. We developed a fusion method combining two hyperspectral imaging (HSI) modalities in the visible-near infrared (VNIR) range of 400–1000 nm and the short-wave infrared (SWIR) range of 1000–2500 nm for the detection of FMs on the surface of fresh raw broiler breast fillets. Thirty different types of FMs that could be commonly found in poultry processing plants were used as samples and prepared in two different sizes (5 × 5 mm2 and 2 × 2 mm2). The accuracies of the developed Fusion model for detecting 2 × 2 mm2 pieces of polymer, wood, and metal were 95%, 95%, and 81%, respectively, while the detection accuracies of the Fusion model for detecting 5 × 5 mm2 pieces of polymer, wood, and metal were all 100%. The performance of the Fusion model was higher than the VNIR- and SWIR-based detection models by 18% and 5%, respectively, when F1 scores were compared, and by 38% and 5%, when average detection rates were compared. The study results suggested that the fusion of two HSI modalities could detect FMs more effectively than a single HSI modality.


JETP Letters ◽  
2020 ◽  
Vol 112 (1) ◽  
pp. 31-36
Author(s):  
V. I. Kukushkin ◽  
V. E. Kirpichev ◽  
E. N. Morozova ◽  
V. V. Solov’ev ◽  
Ya. V. Fedotova ◽  
...  

Nanomaterials ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 1011
Author(s):  
Dimitre Z. Dimitrov ◽  
Zih Fan Chen ◽  
Vera Marinova ◽  
Dimitrina Petrova ◽  
Chih Yao Ho ◽  
...  

In this work, highly conductive Al-doped ZnO (AZO) films are deposited on transparent and flexible muscovite mica substrates by using the atomic layer deposition (ALD) technique. AZO-mica structures possess high optical transmittance at visible and near-infrared spectral range and retain low electric resistivity, even after continuous bending of up to 800 cycles. Structure performances after bending tests have been supported by atomic force microscopy (AFM) analysis. Based on performed optical and electrical characterizations AZO films on mica are implemented as transparent conductive electrodes in flexible polymer dispersed liquid crystal (PDLC) devices. The measured electro-optical characteristics and response time of the proposed devices reveal the higher potential of AZO-mica for future ITO-free flexible optoelectronic applications.


Author(s):  
Chih-Cheng Pai ◽  
Yang-Chu Chen ◽  
Keng-Hao Liu ◽  
Yuan-Hsun Tsai ◽  
Po-Chi Hu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document