BIOACTIVITY ASSESSMENT OF ELECTROLYTICALLY DEPOSITED HYDROXYAPATITE ON TITANIUM SUBSTRATES

Author(s):  
M.H.P. da Silva ◽  
G.A. Soares ◽  
C. N. Elias ◽  
I.R. Gibson ◽  
S.M. Best
Keyword(s):  
2017 ◽  
Vol 137 (1) ◽  
pp. 46-47
Author(s):  
Takeshi Kohno ◽  
Masato Mihara ◽  
Ataru Tanabe ◽  
Takashi Abe ◽  
Masanori Okuyama ◽  
...  

Nanomaterials ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1692
Author(s):  
Emmanuel K. Ampadu ◽  
Jungdong Kim ◽  
Eunsoon Oh

We fabricated a lateral photovoltaic device for use as infrared to terahertz (THz) detectors by chemically depositing PbS films on titanium substrates. We discussed the material properties of PbS films grown on glass with varying deposition conditions. PbS was deposited on Ti substrates and by taking advantage of the Ti/PbS Schottky junction, we discussed the photocurrent transients as well as the room temperature spectrum response measured by Fourier transform infrared (FTIR) spectrometer. Our photovoltaic PbS device operates at room temperature for wavelength ranges up to 50 µm, which is in the terahertz region, making the device highly applicable in many fields.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Claus Moseke ◽  
Katharina Wimmer ◽  
Markus Meininger ◽  
Julia Zerweck ◽  
Cornelia Wolf-Brandstetter ◽  
...  

AbstractTo develop implants with improved bone ingrowth, titanium substrates were coated with homogeneous and dense struvite (MgNH4PO4·6H2O) layers by means of electrochemically assisted deposition. Strontium nitrate was added to the coating electrolyte in various concentrations, in order to fabricate Sr-doped struvite coatings with Sr loading ranging from 10.6 to 115 μg/cm2. It was expected and observed that osteoclast activity surrounding the implant was inhibited. The cytocompatibility of the coatings and the effect of Sr-ions in different concentrations on osteoclast formation were analyzed in vitro. Osteoclast differentiation was elucidated on morphological, biochemical as well as on gene expression level. It could be shown that moderate concentrations of Sr2+ had an inhibitory effect on osteoclast formation, while the growth of osteoblastic cells was not negatively influenced compared to pure struvite surfaces. In summary, the electrochemically deposited Sr-doped struvite coatings are a promising approach to improve bone implant ingrowth.


2021 ◽  
Vol 411 ◽  
pp. 125110
Author(s):  
Jiangmei Peng ◽  
Peiming Liu ◽  
Wan Peng ◽  
Jin Sun ◽  
Xiaohan Dong ◽  
...  

2020 ◽  
Vol 2 (1) ◽  
pp. 18
Author(s):  
Sara Ferraris ◽  
Enrica Verné ◽  
Gissur Örlygsson ◽  
Paulo Tambasco ◽  
Felipe Perraro Sehn ◽  
...  

Biomolecules and extracts from natural products are gaining increasing interest due to their beneficial properties for human health, low toxicity, environmental compatibility and sustainability. In this work, keratin, chitosan and peppermint essential oil have been used for the preparation of coatings on titanium substrates for biomedical implants/devices. All these coatings were obtained from local natural products/byproducts: keratin from discarded wool, chitosan from shrimp shells and peppermint essential oils from a local production. The above cited molecules were selected for their ability to stimulate soft tissue adhesion (keratin), anti-inflammatory activity (chitosan) and antibacterial activity (keratin after metal ion doping, chitosan and mint oil). The coatings were characterized by means of SEM-EDS, FTIR, zeta potential, wettability, tape and scratch tests, and cell and bacteria cultures. The coatings were successfully obtained for all the considered natural substances with good adhesion to the titanium substrates. All the coatings are chemically stable in water and the continuous coatings are mechanically resistant and protective for the metallic substrates. The keratin coatings are hydrophilic while the mint oil and chitosan coatings are hydrophobic; nanofibers, instead of continuous coatings, behave as more hydrophobic. At the physiological pH, the keratin and mint oil coatings are negatively charged when in contact with an aqueous environment, while the chitosan ones are positively charged. The oriented keratin fibers are able to drive fibroblast alignment. The Ag-doped keratin fibers and mint coating show antibacterial properties.


2016 ◽  
Vol 680 ◽  
pp. 60-66 ◽  
Author(s):  
Zhenwei Yan ◽  
Gang Li ◽  
Jiansheng Wang ◽  
Zhanzhe Zhang ◽  
Zaiqiang Feng ◽  
...  
Keyword(s):  

2015 ◽  
Vol 591 ◽  
pp. 012043 ◽  
Author(s):  
M Cisternas ◽  
F Mellero ◽  
M Favre ◽  
H Bhuyan ◽  
E Wyndham

2006 ◽  
Vol 20 (25n27) ◽  
pp. 3999-4004
Author(s):  
HIROSHI MATSUI ◽  
KAZUFUMI WATANABE

Antimony-platinum bilayers were prepared on titanium substrates by the two-step electrodeposition in the usual baths, and then surface alloys were formed by the atom diffusion in the solid phase. The simple antimony layer was little influenced by the substrate in both the measurements of X-ray diffraction and the i - E characteristic in a sulfuric acid solution. Regarding the bilayers, the catalytic activity in hydrogen evolution reaction was very sensitive to the presence of platinum, while the hydrogen adsorbability was quite insensitive. An interaction between antimony and platinum was confirmed by the appearance of a new dissolution wave in the electrochemical measurement and the occurrence of a new diffraction in the X-ray diffraction pattern after the heat-treatment of about 400°C. Although the new diffraction disagreed with any of the reported alloys, clear diffraction pattern of PtSb 2 alloy was observed, when the bilayers were heat-treated at about 600°C for one hour. Considering the penetration depth of X-ray, the alloying of antimony and platinum seems to occur also at low temperatures at least at the top surface.


Author(s):  
V.A. Klimenov ◽  
Yu. F. Ivanov ◽  
A.V. Karlov ◽  
V.V. Trophimov ◽  
L.B. Bataeva

Abstract The covering of titanium implants by means gas-thermal spraying of hydroxyapatite powders is an actual scientific, technical and medical problem. Application of hydroxyapatite for these purposes is more preferable. However, the problem of its structural and cyclic strength under conditions of bioenvironment response determines of application areas of such coatings and reliability of them usage. Structure and phase composition of hydroxyapatite coating under plasma spraying on titanium substrates and their changing, caused as conditions of forming coating on its increasing, so and conditions of spraying an laminar and turbulent plasma streem were studied. Exact belief about the crystalline structure and phase composition of coating is obtained by methods electronic microscopy and X-ray analysis. Changing of coating structure after sintering in the vacuum and electron beam melting in the vacuum is discussed.


Sign in / Sign up

Export Citation Format

Share Document