scholarly journals The Clinical Utility of the Heparin Neutralization Assay in the Diagnosis of Heparin-Induced Thrombocytopenia

2017 ◽  
Vol 24 (5) ◽  
pp. 749-754 ◽  
Author(s):  
Gang Zheng ◽  
Michael B. Streiff ◽  
Clifford M. Takemoto ◽  
Jennifer Bynum ◽  
Elise Gelwan ◽  
...  

Heparin-induced thrombocytopenia (HIT) remains diagnostically challenging. Immunoassays including PF4/heparin enzyme-linked immunosorbent assay (ELISA) have high sensitivity but low specificity. Whether the heparin neutralization assay (HNA) improves the diagnostic accuracy of the PF4/heparin ELISA for HIT is uncertain. In this study, to assess its clinical utility and evaluate whether it improves the diagnostic accuracy for HIT, we implemented HNA in conjunction with PF4/heparin ELISA over a 1-year period. A total of 1194 patient samples were submitted to the laboratory for testing from December 2015 to November 2016. Heparin neutralization assay alone is a poor predictor for HIT, but it has high negative predictive value (NPV): Cases with %inhibition <70% are always negative for serotonin release assay. It improves the diagnostic positive predictive value (PPV) of ELISA without compromising sensitivity: ELISA optical density (OD) ≥1.4 alone has a sensitivity of 88% (14/16) and a PPV of 61% (14/23); with HNA %inhibition ≥70%, the sensitivity remains 88% (14/16) and PPV is 82% (14/17). 4Ts score correlates with ELISA OD and predicts HIT; the predictive accuracy of 4Ts score is further improved by HNA. Interestingly, HNA %inhibition of <70% correlates with low 4Ts scores. Based on its high NPV, HNA has the potential to facilitate more timely and accurate HIT diagnosis.

Perfusion ◽  
2019 ◽  
Vol 35 (5) ◽  
pp. 378-383 ◽  
Author(s):  
Jaclyn Sullivan ◽  
Erica Bak ◽  
Mary Jane Sullivan ◽  
Payal K. Gurnani

There are currently no scoring tools validated for use in predicting heparin-induced thrombocytopenia in patients receiving extracorporeal membrane oxygenation. This study aims to determine the predictive value of the Warkentin 4T score, Lilo-Le Louet score, and the heparin-induced thrombocytopenia expert probability score in detecting heparin-induced thrombocytopenia in patients on extracorporeal membrane oxygenation. This was a single center, retrospective, observational cohort study of patients at Rush University Medical Center. Heparin-induced thrombocytopenia–positive patients were defined as those with an optical density greater than or equal to 0.4, consistent with a positive anti-platelet 4 heparin antibody. Out of 39 patients on extracorporeal membrane oxygenation with suspected heparin-induced thrombocytopenia, six (15.4%) were found to be anti-platelet 4–positive. A heparin-induced thrombocytopenia diagnosis was confirmed by serotonin-release assay in two patients (5.1%). The 4T, heparin-induced thrombocytopenia expert probability, and Lilo-Le Louet scoring tools all demonstrated a low positive predictive value (21.4%, 16.7%, and 6.7%, respectively), with the 4T and heparin-induced thrombocytopenia expert probability scores demonstrating the highest specificity (66.7% and 84.8%, respectively) and lowest sensitivity (50% and 16.7%, respectively). The Lilo-Le Louet score had high sensitivity (100%) and low specificity (12.5%) in post-cardiopulmonary bypass patients. Based on the findings of this study, all three scoring tools have limited utility for predicting heparin-induced thrombocytopenia in patients on extracorporeal membrane oxygenation.


2016 ◽  
Vol 23 (3) ◽  
pp. 282-286 ◽  
Author(s):  
Brianne M. Ritchie ◽  
Jean M. Connors ◽  
Katelyn W. Sylvester

Background: Previous studies have demonstrated optimized diagnostic accuracy in utilizing higher antiheparin–platelet factor 4 (PF4) enzyme-linked immunosorbent assay (ELISA) optical density (OD) thresholds for diagnosing heparin-induced thrombocytopenia (HIT). We describe the incidence of positive serotonin release assay (SRA) results, as well as performance characteristics, for antiheparin–PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units in the diagnosis of HIT at our institution. Methods: Following institutional review board approval, we conducted a single-center retrospective chart review on adult inpatients with a differential diagnosis of HIT evaluated by both antiheparin–PF4 ELISA and SRA from 2012 to 2014. The major endpoints were to assess incidence of positive SRA results, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy at antiheparin–PF4 ELISA values ≥0.4 OD units when compared to values ≥0.8 and ≥1.0 OD units. Clinical characteristics, including demographics, laboratory values, clinical and safety outcomes, length of stay, and mortality, were collected. Results: A total of 140 patients with 140 antiheparin–PF4 ELISA and SRA values were evaluated, of which 23 patients were SRA positive (16.4%) and 117 patients were SRA negative (83.6%). We identified a sensitivity of 91.3% versus 82.6% and 73.9%, specificity of 61.5% versus 87.2% and 91.5%, PPV of 31.8% versus 55.9% and 63.0%, NPV of 97.3% versus 96.2% and 94.7%, and accuracy of 66.4% versus 86.4% and 88.6% at antiheparin–PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units, respectively. Conclusion: Our study suggests an increased antiheparin–PF4 ELISA threshold of 0.8 or 1.0 OD units enhances specificity, PPV, and accuracy while maintaining NPV with decreased sensitivity.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4935-4935
Author(s):  
Tatsiana Mardovina ◽  
John G Chromczak ◽  
Paul W Riley

BACKGROUND: Heparin-induced thrombocytopenia (HIT) is an adverse complication of unfractionated and low molecular weight heparin caused by antibodies recognizing platelet factor 4-heparin (PF4/hep) complexes leading to platelet activation. The diagnosis of HIT is based on the combination of the clinical picture, using the 4T score along with screening and confirmatory methods to detect platelet activating anti‐PF4/H antibodies. OBJECTIVES: Performance was evaluated for two enzyme linked immunosorbent assays (ELISAs), 1) Asserachrom HPIA , Diagnostica Stago Inc., Parsippany, NJ, USA and 2) LIFECODES PF4 Enhanced, Immucor, Inc., Norcross, GA, USA for screening-based detection of PF4/hep antibodies. METHODS: ELISA assays were run per manufacturer recommendations and adapted for automation on a Dynex DS2 automated ELISA platform. Performance characteristics of the two immunoassays were assessed, including sensitivity, specificity, concordance with serotonin release assay (SRA), positive predictive value (PPV) and negative predictive value (NPV). 21 samples were used in the study. Results: Both assays, Asserachrom HPIA and LIFECODES PF4 Enhanced demonstrated 100% sensitivity and NPV, confirming both assays' reliability to detect and rule out HIT (see table). The diagnostic specificity was significantly higher for Asserachrom HPIA vs. LIFECODES PF4 Enhanced (77.8% vs 31.6%). Asserachrom HPIA showed fewer false positive results, with PPV of 42.9% for Asserachrom HPIA vs. 13.3% for LIFECODES PF4 Enhanced. No false negative results were found for either assay. Asserachrom HPIA demonstrated 81.0% concordance with SRA, vs. 38.1% for LIFECODES PF4 Enhanced. CONCLUSIONS: HIT is a life-threatening disorder, with diagnosis depending on clinical findings using the 4T score along with laboratory evaluation. Combining the 4T score with PF4/hep antibody screening increases the accuracy of excluding HIT. Our observations indicate Asserachrom HPIA provides results with high sensitivity and specificity, minimizing false positivess, allowing use of alternative anticoagulants more selectively in at risk patients, to potentially improve patient management while minimizing costs. Disclosures Mardovina: Diagnostica Stago, Inc.: Employment. Chromczak:Diagnostica Stago, Inc.: Employment. Riley:Diagnostica Stago, Inc.: Employment.


2017 ◽  
Vol 24 (6) ◽  
pp. 944-949 ◽  
Author(s):  
Shinya Motohashi ◽  
Takefumi Matsuo ◽  
Hidenori Inoue ◽  
Makoto Kaneko ◽  
Shunya Shindo

Heparin-induced thrombocytopenia (HIT) is one of the serious complications in patients who undergo cardiac surgery. However, there remains a major problem in diagnosing HIT because the current immunological assays for detection of HIT antibody have limitations. Furthermore, the clinical course of thrombocytopenia in this surgery makes it increasingly difficult to diagnose HIT. We investigated the relationship between platelet count and HIT antibody in 59 patients who underwent cardiac surgery using cardiopulmonary bypass (CPB). The number of postoperative HIT antibody-positive patients evaluated using enzyme-linked immunosorbent assay kit (polyanion IgG/IgA/IgM complex antibodies/antiplatelet factor 4 enhanced) was 37 (62.7%). In contrast, platelet activation by HIT antibody was evaluated using the serotonin release assay (SRA). More than 20% and 50% release of serotonin was obtained from 12 patients (20.3%) and 8 patients (13.6%), respectively. The levels of d-dimer were significantly different on postoperative day 14 between SRA-positive and SRA-negative groups; however, postoperative thrombus complication was not detected using sonography in the patients with positive serotonin release at all. After being decreased by the operation, their platelet count recovered within 2 weeks in both groups equally. In our study, although the patients were positive in the platelet activating HIT antibody assay, they remained free from thrombosis and their platelet count recovered after early postoperative platelet decrease. Therefore, in addition to the SRA, monitoring of platelet count might be still considered an indispensable factor to facilitate the prediction of HIT thrombosis prior to manifestation in the patients undergoing cardiac surgery using CPB.


2021 ◽  
pp. 106002802110387
Author(s):  
Long To ◽  
Dana Attar ◽  
Brittany Lines ◽  
Melissa McCarty ◽  
Hassan Nemeh ◽  
...  

Background: Heparin exposure and device-related thrombocytopenia complicate the diagnosis of heparin-induced thrombocytopenia (HIT) in patients receiving mechanical circulatory support (MCS). To improve anticoagulation management for patients with newly implanted MCS devices, incidence of confirmed HIT needs to be further characterized. Objectives: The purpose of this study is to describe the incidence of HIT and clinical utility of the 4Ts score in patients with newly implanted MCS devices. Methods: This is a retrospective analysis of MCS patients receiving unfractionated heparin from 2014 to 2017. The primary end point was incidence of laboratory-confirmed HIT. Strong positive, likely positive, low probability, and negative HIT categories were established based on heparin-induced platelet antibody (HIPA) and serotonin release assay (SRA). Secondary end points include characterization of platelet trends, argatroban use, incidence of HIT among each of the MCS devices, and utility of 4Ts score. Results: A total of 342 patient encounters met inclusion criteria, of which 68 HIPA tests and 25 SRAs were ordered. The incidence of HIT was 0.88% (3/342) and 4.4% (3/68) in patients with suspected HIT. Of the 68 HIPA tests, 3 (4.4%) were considered strong positive and 3 of the 25 SRAs were positive. Median 4Ts score was 4 [2.5-4] and optical density 0.19 [0.11-0.54]. The positive predictive value for the 4Ts score was 0.15 (CI = 0.03-0.46) and negative predictive value, 0.93 (CI = 0.82-0.98). Conclusion and Relevance: HIT occurs infrequently with newly implanted MCS devices. The 4Ts score appears to have a high negative predictive value for ruling out HIT.


2007 ◽  
Vol 14 (4) ◽  
pp. 410-414 ◽  
Author(s):  
Suresh G. Shelat ◽  
Anne Tomaski ◽  
Eleanor S. Pollak

Heparin-induced thrombocytopenia (HIT) can lead to life-threatening and limb-threatening thrombosis. HIT is thought to be initiated by the interaction of pathogenic antibodies toward a complex platelet factor 4 (PF4) and heparin (PF4:H), which can activate platelets and predispose to thrombosis. As such, the laboratory diagnosis of HIT includes antigenic and functional assays to detect antibodies directed at PF4:H complexes. We performed a retrospective analysis of 1017 consecutive samples tested by serotonin-release assay and by enzyme-linked immunosorbent assay (ELISA). Most samples showed no serologic evidence of HIT, whereas 4% to 5% of samples demonstrated both antigenic and functional serological evidence for HIT. Approximately 12% to 18% of samples showed immunologic evidence of anti-PF4:H antibodies but without functional evidence of serotonin release in vitro. Interestingly, a small minority of samples (0.7%) caused serotonin release but were negative in the ELISA. The results are presented using cutoff values established at our hospital and for the ELISA manufacturer. This study provides a pretest probability of the serologic results from an antigenic assay (ELISA) and a functional assay (serotonin-release assay) in patients clinically suspected of having HIT.


Blood ◽  
2013 ◽  
Vol 122 (21) ◽  
pp. 1130-1130
Author(s):  
Varda Deutsch ◽  
Michal Cipok ◽  
Sigi Kay ◽  
Yvette Levy ◽  
Shoshana Bar On ◽  
...  

Abstract Background Heparin-induced thrombocytopenia (HIT) is a serious complication of heparin treatment, associated with morbidity and mortality. HIT is characterized by thrombocytopenia and thrombotic complications secondary to the formation of antibodies (Abs) against heparin-platelet-factor 4 (PF4) complexes. The pathologic mechanism involves the binding of the heparin-immune-complex to the platelet-Fc-receptor, resulting in platelet activation, aggregation, and rapid elimination. The diagnosis of HIT requires laboratory confirmation. Common laboratory testing is based on immune detection of antibodies directed against the PF4/heparin complex (ID-H/PF4-PaGIA or ELISA). However, these assays suffer from methodological limitations, especially low specificity, as compared to the platelet functional assays. The “gold standard” functional test for detecting of platelet-activating antibodies is the radioactive [14C] serotonin-release assay (14C-SRA) (Sheridan D, et al, Blood. 1986;67:27-30, Kelton JG, et al.,Blood.1988;72:925-30). However, the assay includes the use of a radiolabeled biological probe and requires considerable expertise to obtain reliable results. Consequently, its use is limited to research laboratories. Aim To overcome the methodological limitations associated with current assays, we modified a functional flow-cytometry assay (FCA), which exhibits high sensitivity and specificity (Tomer, A. Br J Haematol, 1997;98: 648-656 , Tomer, A., et al, Am J Hematol, 1999;61: 53-61). This assay, similar in concept to the 14C-SRA, determines the capacity of the patient's serum to activate platelets in the presence of heparin, using a fluorescent probe. Methods Consecutive samples from 254 patients clinically suspected for HIT were tested. The FCA assay was compared with the standard ID-H/PF4-PaGIA antigenic assay (DiaMed, Switzerland) with two dilutions to assess specificity (Nellen, V., et al.,Haematologica, 2012;97: 89-97). Results Of the total 254 samples tested, 48 (19%) were positive by PaGIA, compared to 13 (5.1%) positive by the functional FCA (Table 1). The number of PaGIA positive samples was reduced to 24 (9.4%) by 1:16 dilution, and to 14 (5.5%) by 1:32 dilution. All FCA positive samples were positive at all PaGIA dilutions (relative sensitivity 93%). Thirty PaGIA negative samples were all negative by the FCA (relative specificity 100%). Conclusion The results suggest that the functional FCA is a practical, sensitive, and highly specific test for the reliable diagnosis of HIT. Disclosures: No relevant conflicts of interest to declare.


Blood ◽  
2021 ◽  
Vol 138 (Supplement 1) ◽  
pp. 756-756
Author(s):  
Jori E. May ◽  
Kimberly D. Martin ◽  
Laura J. Taylor ◽  
Eric L. Wallace ◽  
Marisa B. Marques

Abstract Background: Heparin-induced thrombocytopenia (HIT) is a rare disorder with potential to cause significant morbidity and mortality. Early identification and initiation of non-heparin anticoagulation can prevent devastating thrombotic events. However, over-testing is common and can lead to result misinterpretation, unnecessary heparin avoidance, and increased cost. When there is concern for HIT, guidelines from the American Society of Hematology recommend calculation of the 4Ts score to determine the need for laboratory testing. The Choosing Wisely® initiative recommends against laboratory testing in patients with a low probability score of ≤3. In patients with an intermediate or high probability score (≥4), screening with enzyme-linked immunosorbent assay (ELISA) is performed first. If positive, the diagnosis of HIT is confirmed with a functional assay, commonly the serotonin release assay (SRA). Methods: In an effort to increase recognition of HIT, providers at a large academic medical center received a non-interruptive alert in the electronic medical record (EMR) on all patients in whom the platelet count declined by ≥50% starting in Aug 2017. We performed a retrospective evaluation of 1) the number of alerts and 2) all ELISA results obtained with or without an alert, over a 90-day period (Dec 2019 to March 2020). A 4Ts score was calculated by chart review by the first author in real-time as the alert was sent (blinded to ELISA and SRA results). Among those patients with multiple alerts or test orders, the first instance was used for analysis. Demographic and clinical characteristics were reported using frequencies and percentages, means (standard deviation, SD), and medians (interquartile range, IQR). Patients with alerts and ELISA testing ordered were compared with 2 groups: 1) patients with alerts but no ELISA ordered; 2) patients with no alerts but ELISA ordered. Comparisons were performed using chi squared tests, Fisher's exact tests, t-tests and Wilcoxon rank-sum tests as appropriate. Results: In the 90-day observation period, 302 alerts were fired in 270 patients (Figure 1). Thirty alerts (28 patients, 10%) were generated for patients admitted for organ donation or post-stem cell transplantation, for whom platelet count decline was expected. Excluding these patients, there were 272 alerts in 242 patients (approximately 3 alerts per day in a 1,157-bed hospital). Of patients with alerts, 22 (8%) had a platelet count inaccuracy (i.e. platelets clump or another reason) and 18 (7%) did not receive heparin prior to platelet decline, for a cumulative total of 40 (15%) inappropriate alerts. In patients with an alert, the ELISA was ordered more frequently for those with a lower platelet nadir (77x10 9/L vs. 115x10 9/L, p&lt;0.0001) or in those with a thrombotic event (11 patients (17%) vs. 6 patients (4%), p=0.0021) (Table 1). Those without an ELISA ordered were more likely to have a low 4Ts score (23 patients (36%) vs. 81 patients (58%), p&lt;0.0001). In addition to 71 patients with an alert, an ELISA was also ordered for 67 patients without an alert (n=138) (Figure 1). Close to half of ELISA-tested patients had a low 4Ts score (n=51, 46%) (Figure 2). In patients with an alert and ELISA not ordered, 18 (27%) had an intermediate or high 4Ts score. Seven patients were diagnosed with HIT based on a positive SRA, 6 with an alert and 1 without. The alert demonstrated a sensitivity of 86% (95% CI, 59.8-100%) and specificity of 50% (95% CI, 41.8-58.9%) with a positive predictive value of 0.0845 (95% CI, 0.0198-0.1492) and negative predictive value of 0.9851 (95% CI, 0.9560-1.0000). Conclusion: An EMR alert based on platelet count decline had multiple shortcomings including frequent inappropriate firings and a lack of guidance on appropriate indications for testing. This evaluation of institutional testing practices indicates frequent use and misinterpretation of ELISA discordant with evidence-based guidelines. Although prompt diagnosis of HIT is important, alternative strategies for identification of at-risk patients and communication of recommended actions to providers should be considered. Because the 4Ts score includes variables difficult to automate in the EMR, our institution is exploring electronic consultation and real-time expert provider access to overcome these limitations. Figure 1 Figure 1. Disclosures No relevant conflicts of interest to declare.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4689-4689
Author(s):  
Sriman Swarup ◽  
Somedeb Ball ◽  
Nimesh Adhikari ◽  
Anita Sultan ◽  
Khatrina Swarup ◽  
...  

Introduction: Heparin induced thrombocytopenia (HIT) is a severe prothrombotic condition, usually triggered by exposure to heparin products. It is characterized by platelet activation induced by the formation of antibodies to the platelet factor 4 (PF4)/ heparin polyanion complexes. Diagnostic algorithm includes clinical scoring (4T score) alongside serological test for detection of these antibodies (HIT-Ab), while serotonin release assay (SRA) remains the gold- standard for confirmation. The automated latex immunoturbidometric assay (LIA) has recently been FDA approved as a screening tool for HIT and is a potential alternative to the conventional particle immunofiltration assay (PIFA) for time-sensitive detection of HIT-Ab to guide treatment considerations. We recently introduced LIA in our institution. In this study, we present our experience with LIA in comparison to PIFA in the diagnosis of HIT. Methods: We retrospectively reviewed the charts of all the patients on whom a PIFA was ordered between March 2017 and March 2018 in our hospital. We collected information on the results of the PIFA and SRA (if available). We replaced PIFA with LIA for HIT screening. Then, we introduced a structured protocol for diagnosis of HIT in our institution by incorporating 4T scoring alongside LIA order in the electronic medical record (EMR), in December 2018. We reviewed the EMR of all the patients on whom HIT-Ab test (LIA) was ordered between January and June of 2019, and collected similar information as before. All the data were compiled in a single master excel sheet for calculation of performance characteristics (sensitivity, specificity, positive and negative predictive values) for both PIFA and LIA. A patient was considered to have the diagnosis of HIT if the result of SRA was available and positive. Results: In the first phase, a total of 31 orders for SRA was noted against 170 PIFA orders. Five patients had a positive SRA, of whom two were PIFA negative. Half the patients with a negative SRA result were positive for PIFA. Hence, the sensitivity and specificity of PIFA test for our study population were noted to be 60% and 50%, respectively. PIFA had a positive predictive value (PPV) of mere 18.75% for the diagnosis of HIT, whereas the negative predictive value (NPV) was found to be 86.66%. Introduction of structured protocol for HIT diagnosis substantially reduced the number of inappropriate SRA orders in the second phase. On review of data for six months with the new HIT-Ab test LIA, SRA was ordered in only eight patients, to go with 69 orders for the LIA. The result of LIA was positive in all three patients with a positive SRA, whereas it was false positive in four instances. Only one patient was negative for both LIA and SRA during this period. LIA was found to be 100% sensitive and 20% specific for the diagnosis of HIT in our sample. PPV and NPV for LIA were 42.85% and 100%, respectively. Conclusion: The sensitivity and specificity of LIA were found to be 100% and 20%, respectively, in our study population, which is different from the earlier report (Warkentin et al. 2017). The small sample size is a limitation of our study. Higher PPV and NPV for LIA, with its quick turnaround time, make it a useful alternative for the time-sensitive determination of post-test probability for HIT in patients. [HIT- Ab- Heparin Induced Thrombocytopenia Antibody, PIFA- Particle Immunofiltration Assay, LIA- Latex Immunoturbidometric Assay, SRA- Serotonin Release Assay, +ve- Positive, -ve - Negative, PPV- Positive Predictive Value, NPV- Negative Predictive Value] Disclosures No relevant conflicts of interest to declare.