Prediction of the sound reduction index of clay hollow brick walls

2020 ◽  
Vol 27 (2) ◽  
pp. 155-168 ◽  
Author(s):  
Nicola Granzotto ◽  
Antonino Di Bella ◽  
Edoardo Alessio Piana

Clay hollow brick walls are still popular in building industry, but the prediction of their sound insulation properties is not straightforward due to their inhomogeneous and anisotropic characteristics. In this article, a classic approach has been used to determine the sound transmission coefficient of brick walls, assuming an orthotropic behaviour and deriving the mechanical and dynamic characteristics from datasheet information. Different types of walls with horizontal and vertical mortar joints have been analysed. Experimental measurements of the sound reduction index carried out according to ISO 10140-2 standard have been performed, and the resulting values are compared with the predictions in the proposed model. It was found that the sound reduction index can be fairly predicted in the low-frequency range and it is correctly predicted in the mass law region, whereas in the high-frequency range the inner block structure is responsible for a loss of performance which is difficult to predict with the analytical methods.

2011 ◽  
Vol 3 (1) ◽  
pp. 33-40 ◽  
Author(s):  
Marius Mickaitis ◽  
Aleksandras Jagniatinskis ◽  
Boris Fiks

For the purposes of accumulating knowledge of how to comply with requirements for new buildings of obligatory sound class C or enhanced acoustic comfort sound classes A and B (Lithuanian Building Technical regulations STR 2.01.07:2003), the article discusses improvement on airborne sound insulation of partitions between dwellings using additional plasterboard layers. The results of an empirical approach were obtained performing in situ measurements of the partitions of masonry from silicate blocks and expanded-clay concrete blocks. Theoretical calculations without the evaluation of flanking paths are added. The paper looks at the peculiarities of in situ measurement methods and the estimation of the limiting uncertainty of the sound reduction index. It is showed that the values of the in situ measurements of the airborne sound reduction index in accordance with requirements EN ISO 140 and EN ISO 717 series for rooms having volume higher than 50 m3 varies depending on frequency range. It has been stated, that improvement on the weighed airborne sound reduction index in the frequency range from 100 Hz to 3150 Hz depends on the properties of additional layers and on the characteristics of the main constructions. Resonance in the low frequency range arising due to additional layers may reduce the weighed airborne sound reduction index defined in the frequency range from 50 Hz to 3150 Hz. This fact must be taken into account when designing improvement on masonry wall insulation using an additional layer in dwellings.


Author(s):  
Olga Khrystoslavenko ◽  
Raimondas Grubliauskas

To design a sound-absorbing panel, it is important to identify factors that affect the maximum sound absorption of low, middle and high frequency sounds. Perforation effect is very important for the noise-reducing and noiseabsorbing panels. Perforations are often used for sound reduction. Experimental data shows that the perforation is very effective to absorb low-frequency noise. In the presented study, influence of perforation coefficient of noise reduction was analyzed with theoretical and experimental methods. The experiments were conducted in noise reduction chamber using an perforated construction with glass wool filler. Sound reductions index of 15 dB indicates good acoustic properties of the panel.


2015 ◽  
Vol 752-753 ◽  
pp. 800-803
Author(s):  
Jun Oh Yeon ◽  
Kyoung Woo Kim ◽  
Kwan Seop Yang ◽  
Myung Jun Kim

Impact sound reduction under various conditions for a total of eight different types of Floor cosverings currently used in South Korea. The results of floor impact sound within the test building under bare slab conditions indicated a high reduction rate for lightweight impact sound, but poor reduction during heavyweight impact sound testing (Bang Machine, Impact Ball). However, a reduction was identified in the mid-high frequency range (315 Hz–3150 Hz) for the lightweight impact sound, as was a reduction of approximately 2 dB–3 dB at specific frequency ranges, depending on the thickness of the floor coverings, for the heavyweight impact sound on the Ondol structure.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


2021 ◽  
Vol 11 (4) ◽  
pp. 1932
Author(s):  
Weixuan Wang ◽  
Qinyan Xing ◽  
Qinghao Yang

Based on the newly proposed generalized Galerkin weak form (GGW) method, a two-step time integration method with controllable numerical dissipation is presented. In the first sub-step, the GGW method is used, and in the second sub-step, a new parameter is introduced by using the idea of a trapezoidal integral. According to the numerical analysis, it can be concluded that this method is unconditionally stable and its numerical damping is controllable with the change in introduced parameters. Compared with the GGW method, this two-step scheme avoids the fast numerical dissipation in a low-frequency range. To highlight the performance of the proposed method, some numerical problems are presented and illustrated which show that this method possesses superior accuracy, stability and efficiency compared with conventional trapezoidal rule, the Wilson method, and the Bathe method. High accuracy in a low-frequency range and controllable numerical dissipation in a high-frequency range are both the merits of the method.


2019 ◽  
Vol 9 (15) ◽  
pp. 3157 ◽  
Author(s):  
O ◽  
Jin ◽  
Choi

In this paper, we propose a compact four-port coplanar antenna for cognitive radio applications. The proposed antenna consists of a coplanar waveguide (CPW)-fed ultra-wideband (UWB) antenna and three inner rectangular loop antennas. The dimensions of the proposed antenna are 42 mm × 50 mm × 0.8 mm. The UWB antenna is used for spectrum sensing and fully covers the UWB spectrum of 3.1–10.6 GHz. The three loop antennas cover the UWB frequency band partially for communication purposes. The first loop antenna for the low frequency range operates from 2.96 GHz to 5.38 GHz. The second loop antenna is in charge of the mid band from 5.31 GHz to 8.62 GHz. The third antenna operates from 8.48 GHz to 11.02 GHz, which is the high-frequency range. A high isolation level (greater than 17.3 dB) is realized among the UWB antenna and three loop antennas without applying any additional decoupling structures. The realized gains of the UWB antenna and three loop antennas are greater than 2.7 dBi and 1.38 dBi, respectively.


2015 ◽  
Vol 655 ◽  
pp. 182-185
Author(s):  
Ke Lan Yan ◽  
Run Hua Fan ◽  
Min Chen ◽  
Kai Sun ◽  
Xu Ai Wang ◽  
...  

The phase structure, and electrical and magnetic properties of La0.7Sr0.3MnO3(LSMO)-xAg (xis the mole ratio,x=0, 0.3, 0.5) composite were investigated. It is found that the sample withx=0 is single phase; the samples withx=0.3 and 0.5 present three phase composite structure of the manganese oxide and Ag. With the increasing of Ag content, the grain size of the samples increases and the grain boundaries transition from fully faceted to partially faceted. The permittivity of spectrum (10 MHz - 1 GHz) and the theoretical simulation reveal that the plasma frequencyfpincrease with Ag content, due to the increasing of free electron concentration, which is further supported by the enhancement of conductivity. While for the permeability (μr'), theμr'decrease with the increasing of Ag content at low frequency range (f< 20 MHz), while at the relative high frequency range (f> 300 MHz), theμr'increased with Ag content. Therefore, the introduction of elemental Ag resulted in a higherμr'at the relative high frequency range.


2007 ◽  
Vol 280-283 ◽  
pp. 919-924
Author(s):  
M.S. Jogad ◽  
V.K. Shrikhande ◽  
A.H. Dyama ◽  
L.A. Udachan ◽  
Govind P. Kothiyal

AC and DC conductivities have been measured by using the real (e¢) and imaginary (e¢¢) parts of the dielectric constant data of glass and glass-ceramics (GC) at different temperatures in the rage 297-642K and in the frequency range 100 Hz to 10 MHz. Using Anderson –Stuart model, we have calculated the activation energy, which is observed to be lower than that of the DC conductivity. The analysis for glass/glass-ceramics indicates that the conductivity variation with frequency exhibits an initial linear region followed by nonlinear region with a maximum in the high-frequency region. The observed frequency dependence of ionic conductivity has been analyzed within the extended Anderson–Stuart model considering both the electrostatic and elastic strain terms. In glass/glassceramic the calculations based on the Anderson-Stuart model agree with the experimental observations in the low frequency region but at higher frequencies there is departure from measured data.


2020 ◽  
Vol 9 (1) ◽  
pp. 1510-1513

The electrical activity of the brain recorded by EEG which used to detect different types of diseases and disorders of the human brain. There is contained a large amount of random noise present during EEG recording, such as artifacts and baseline changes. These noises affect the low -frequency range of the EEG signal. These artifacts hiding some valuable information during analyzing of the EEG signal. In this paper we used the FIR filter for removing low -frequency noise(<1Hz) from the EEG signal. The performance is measured by calculating the SNR and the RMSE. We obtained RMSE average value from the test is 0.08 and the SNR value at frequency(<1Hz) is 0.0190.


Geophysics ◽  
1994 ◽  
Vol 59 (8) ◽  
pp. 1201-1210 ◽  
Author(s):  
Duff C. Stewart ◽  
Walter L. Anderson ◽  
Thomas P. Grover ◽  
Victor F. Labson

A new instrument designed for frequency‐domain sounding in the depth range 0–10 m uses short coil spacings of 5 m or less and a frequency range of 300 kHz to 30 MHz. In this frequency range, both conduction currents (controlled by electrical conductivity) and displacement currents (controlled by dielectric permittivity) are important. Several surface electromagnetic survey systems commonly used (generally with frequencies less than 60 kHz) are unsuitable for detailed investigation of the upper 5 m of the earth or, as with ground‐penetrating radar, are most effective in relatively resistive environments. Most computer programs written for interpretation of data acquired with the low‐frequency systems neglect displacement currents, and are thus unsuited for accurate high‐frequency modeling and interpretation. New forward and inverse computer programs are described that include displacement currents in layered‐earth models. The computer programs and this new instrument are used to evaluate the effectiveness of shallow high‐frequency soundings based on measurement of the tilt angle and the ellipticity of magnetic fields. Forward model studies indicate that the influence of dielectric permittivity provides the ability to resolve thin layers, especially if the instrument frequency range can be extended to 50 MHz. Field tests of the instrument and the inversion program demonstrate the potential for detailed shallow mapping wherein both the resistivity and the dielectric permittivity of layers are determined. Although data collection and inversion are much slower than for low‐frequency methods, additional information is obtained inasmuch as there usually is a permittivity contrast as well as a resistivity contrast at boundaries between different materials. Determination of dielectric permittivity is particularly important for hazardous waste site characterization because the presence of some contaminants may have little effect on observed resistivity but a large effect on observed permittivity.


Sign in / Sign up

Export Citation Format

Share Document