Seismic retrofit of structures using rotational friction dampers with restoring force

2020 ◽  
Vol 23 (16) ◽  
pp. 3525-3540
Author(s):  
Asad Naeem ◽  
Jinkoo Kim

In this study, the seismic performance of a rotational friction damper with restoring force is presented. The torsional spring friction damper consists of rotational friction pads with the heavy duty torsional springs attached on both sides of the friction damper. An analytical model and a design procedure for the damper are developed using capacity spectrum method. A parametric study is carried out to investigate the influence of the torsional spring in the response of the structure when subjected to ground motions. The seismic performances of steel structures retrofitted with the torsional spring friction damper and conventional rotational friction dampers are evaluated using fragility analysis, which shows that the structure retrofitted with the torsional spring friction damper has the smallest probability of reaching the specific limit states.

1999 ◽  
Vol 26 (1) ◽  
pp. 55-71 ◽  
Author(s):  
Yaomin Fu ◽  
Sheldon Cherry

This paper describes the development of a proposed seismic design procedure for friction-damped steel structures, which employs the lateral force provisions used in many modern building codes. Closed-form expressions are first derived that relate the normalized response of a single degree of freedom friction-damped system with the system parameters, such as bracing stiffness ratio, damper slip ratio, and frame member ductility. A parametric analysis is then used to reveal that the seismic displacement of a friction-damped frame can be controlled by combining the frame stiffness with the bracing stiffness of the friction damper component, while the seismic force can be controlled by the damper slip force. A force modification factor (equivalent to the code R-factor) and displacement estimate for a friction-damped system are next determined. The single degree of freedom results are subsequently used to develop expressions for dealing with the multi degree of freedom situation, which permits the seismic lateral force design procedure adopted by many current building codes to be applied to friction-damped systems. The proposed procedure allows the frame response to be controlled so that the displacement can be limited to small magnitudes and the overall structural shape to an essentially straight-line deformation. Design examples illustrate that friction-damped frame systems are economical and offer a better overall response performance than that provided by conventional systems under the design earthquake.Key words: passive energy dissipation system, friction damper, steel frame, design procedure, static analysis.


1990 ◽  
Vol 112 (2) ◽  
pp. 175-182 ◽  
Author(s):  
T. M. Cameron ◽  
J. H. Griffin ◽  
R. E. Kielb ◽  
T. M. Hoosac

A procedure is outlined for determining the optimal design of friction dampers for high-speed turbomachinery blading. The procedure includes: An integration of bench test results with finite-element analysis and a single-mode blade model to ensure accuracy of the analytical model and improve reliability of the friction damper design; an extension of the single-mode blade model to predict the engine behavior of friction dampers; and a new way of viewing analytical and experimental results in terms of a damper performance curve to determine optimal design parameters, when the levels of excitation and damping in the system are unknown. Unique experiments are performed on a test disk in order to demonstrate and verify the accuracy of the design procedure.


2008 ◽  
Vol 385-387 ◽  
pp. 657-660 ◽  
Author(s):  
Lucrezia Cascini ◽  
Raffaele Landolfo ◽  
F. Portioli

To develop a durability design procedure based on lifetime safety factor method, different dose-response functions based on both ISO standards and the literature are presented for the prediction of the thickness loss due to atmospheric corrosion in metal structures. Finally, serviceability and ultimate limit states are defined for the durability design against corrosion.


Author(s):  
Canxing Qiu ◽  
Jiawang Liu ◽  
Jun Teng ◽  
Zuohua Li ◽  
Xiuli Du

Shape memory alloys (SMAs) gained increasing attentions from the perspective of seismic protection, primarily because of their excellent superelasticity, satisfactory damping and high fatigue life. However, the superelastic strain of SMAs has an upper limit, beyond which the material completes the austenite to martensite phase transformation and is followed by noticeable strain hardening. The strain hardening behavior would not only induce high force demand to the protected structures, but also cause unrecoverable deformation. More importantly, the SMAs may fracture if the deformation demand exceeds their capacity under severe earthquakes. In the case of installing SMA braces (SMABs) in the multi-story concentrically braced frames (CBFs), the material failure would lead to the malfunction of SMABs and this further causes building collapse. The friction mechanism could behave as a “fuse” through capping the strength demand at a constant level. Therefore, this paper suggests connecting the SMAB with a friction damper to achieve a novel brace, i.e. the SMA-friction damping brace (SMAFDB). A proof-of-concept test was carried out on a homemade specimen and the test results validated the novel brace behaves in a desirable manner. In addition, to explore the seismic response characteristics of the SMAFDB within structures, a six-story CBF equipped with SMAFDBs was designed and compared against those incorporated with SMABs or friction damping braces (FDBs) at the frequently occurred earthquake (FOE), design basis earthquake (DBE) and maximum considered earthquake (MCE). The comparative results show the SMAFDB is superior to the counterparts. Under the FOE and DBE ground motions, the SMAFDBs successfully eliminated residual deformations as the SMABs do, and achieved identical maximum interstory drift as the FDBs. Under the MCE ground motions, the SMAFDBs not only well addressed the brace failure problem that was possibly encountered in the SMABs, but also better controlled residual deformation than the FDBs.


Author(s):  
Walter Sextro ◽  
Karl Popp ◽  
Ivo Wolter

Friction dampers are installed underneath the blade platforms to improve the reliability. Because of centrifugal forces the dampers are pressed onto the platforms. Due to dry friction and the relative motion between blades and dampers, energy is dissipated, which results in a reduction of blade vibration amplitudes. The geometry of the contact is in many cases like a Hertzian line contact. A three-dimensional motion of the blades results in a two-dimensional motion of one contact line of the friction dampers in the contact plane. An experiment with one friction damper between two blades is used to verify the two-dimensional contact model including microslip. By optimizing the friction dampers masses, the best damping effects are obtained. Finally, different methods are shown to calculate the envelope of a three-dimensional response of a detuned bladed disk assembly (V84.3-4th-stage turbine blade) with friction dampers.


Author(s):  
Eric Brehm ◽  
Robert Hertle ◽  
Markus Wetzel

In common structural design, random variables, such as material strength or loads, are represented by fixed numbers defined in design codes. This is also referred to as deterministic design. Addressing the random character of these variables directly, the probabilistic design procedure allows the determination of the probability of exceeding a defined limit state. This probability is referred to as failure probability. From there, the structural reliability, representing the survival probability, can be determined. Structural reliability thus is a property of a structure or structural member, depending on the relevant limit states, failure modes and basic variables. This is the basis for the determination of partial safety factors which are, for sake of a simpler design, applied within deterministic design procedures. In addition to the basic variables in terms of material and loads, further basic variables representing the structural model have to be considered. These depend strongly on the experience of the design engineer and the level of detailing of the model. However, in the clear majority of cases [1] failure does not occur due to unexpectedly high or low values of loads or material strength. The most common reasons for failure are human errors in design and execution. This paper will provide practical examples of original designs affected by human error and will assess the impact on structural reliability.


Sign in / Sign up

Export Citation Format

Share Document