scholarly journals Evaluation of comprehensiveness and reliability of electronic health records concerning resuscitation efforts within academic intensive care units: a retrospective chart analysis

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Michael S. Dittmar ◽  
Sabrina Zimmermann ◽  
Marcus Creutzenberg ◽  
Sylvia Bele ◽  
Diane Bitzinger ◽  
...  

Abstract Background According to the literature, the validity and reliability of medical documentation concerning episodes of cardiopulmonary resuscitation (CPR) is suboptimal. However, little is known about documentation quality of CPR efforts during intensive care unit (ICU) stays in electronic patient data management systems (PDMS). This study analyses the reliability of CPR-related medical documentation within the ICU PDMS. Methods In a retrospective chart analysis, PDMS records of three ICUs of a single university hospital were searched over 5 y for CPR check marks. Respective datasets were analyzed concerning data completeness and data consistency by comparing the content of three documentation forms (physicians’ log, nurses’ log, and CPR incident form), as well as physiological and therapeutic information of individual cases, for missing data and plausibility of CPR starting time and duration. To compare data reliability and completeness, a quantitative measure, the Consentaneity Index (CI), is proposed. Results One hundred sixty-five datasets were included into the study. In 9% (n = 15) of cases, there was neither information on the time points of CPR initiation nor on CPR duration available in any data source. Data on CPR starting time and duration were available from at least two data sources in individual cases in 54% (n = 90) and 45% (n = 74), respectively. In these cases, the specifications of CPR starting time did differ by a median ± interquartile range of 10.0 ± 18.5 min, CPR duration by 5.0 ± 17.3 min. The CI as a marker of data reliability revealed a low consistency of CPR documentation in most cases, with more favorable results, if the time interval between the CPR episode and the time of documentation was short. Conclusions This study reveals relevant proportions of missing and inconsistent data in electronic CPR documentation in the ICU setting. The CI is suggested as a tool for documentation quality analysis and monitoring of improvements.

2021 ◽  
Vol 12 (04) ◽  
pp. 897-909
Author(s):  
Wenhui Zhang ◽  
Mani Sotoodeh ◽  
Joyce C. Ho ◽  
Roy L. Simpson ◽  
Vicki S. Hertzberg

Abstract Objectives This study aimed to compare the concordance of pressure injury (PI) site, stage, and count documented in electronic health records (EHRs); explore if PI count during each patient hospitalization is consistent based on PI site or stage count in the diagnosis or chart event records; and examine if discrepancies in PI count were associated with patient characteristics. Methods Hospitalization records with the International Classification of Diseases ninth edition (ICD-9) codes, chart events from two systems (CareVue, MetaVision), and clinical notes on PI were extracted from the Medical Information Mart for Intensive Care (MIMIC)-III database. PI site and stage counts from individual hospitalization were computed. Hospitalizations with the same or different counts of site and stage according to ICD-9 codes (site and stage), CareVue (site and stage), or MetaVision (stage) charts were defined as consistent or discrepant reporting. Chi-squared, independent t-, and Kruskal–Wallis tests were examined if the count discrepancy was associated with patient characteristics. ICD-9 codes and charts were also compared for people with one site or stage. Results A total of 31,918 hospitalizations had PI data. Within hospitalizations with ICD-9-coded sites and stages, 55.9% reported different counts. Within hospitalizations with CareVue charts on PI, 99.3% reported the same count. For hospitalizations with stages based on ICD-9 codes or MetaVision chart data, only 42.9% reported the same count. Discrepancies in counts were consistently and significantly associated with variables including PI recording in clinical notes, dead/hospice at discharge, more caregivers, longer hospitalization or intensive care unit stays, and more days to first transfer. Discrepancies between ICD-9 code and chart values on the site and stage were also reported. Conclusion Patient characteristics associated with PI count discrepancies identified patients at risk of having discrepant PI counts or worse outcomes. PI documentation quality could be improved with better communication, care continuity, and integrity. Clinical research using EHRs should adopt systematic data quality analysis to inform limitations.


2020 ◽  
Vol 30 (Supplement_5) ◽  
Author(s):  
M Ben Rejeb ◽  
A Ben Cheikh ◽  
S Bhiri ◽  
H Ghali ◽  
M Kahloul ◽  
...  

Abstract Background The infections caused by emergent highly resistant bacteria (eHBR) that develop in intensive care units (ICUs) may result in significant patient illnesses and deaths, extend the duration of hospital stays and generate added costs. Facing this problem, the screening that emphasizes early identification of colonized patients, reduces the prevalence and incidence of infection, improves patient outcomes and reduces healthcare costs. In this context, we have implemented a screening for eHBR in ICUs of Sahloul university hospital of Sousse (Tunisia), which we report in this study the first six-months outcomes. Methods Rectal swab cultures were collected to detect Vancomycin resistant enterococcus (VRE) and Carbapenemase producing Enterobacteriaceae (CPE) among patients admitted in six ICUs of Sahloul university hospital of Sousse (Tunisia) and more than three times, at least one week apart, between 1 June and 31 December 2018. Results During the study period 174 patients were screened. Of them, 69.5% were male and 73.6% were admitted in surgical ICU. In total, 161 and 152 samples were realized respectively for the detection of CPE and VRE. These samples were positive in 15% and 8.5% respectively for CPE and VRE. Klebsiella pneumoniae OXA 48 was the most isolated CPE (80%). Conclusions Our screening program helped us in infection control by early identification of patients, thereby facilitating an informed decision about infection prevention interventions. Moreover, these results encouraged us to improve and generalize this program throughout the hospital. Key messages eHRB screening becomes an important axis in the prevention of eHRB infections in our facilities. eHRB screening allows the reinforcement of the basic infection prevention and control measures.


Author(s):  
Erman Yıldız

BACKGROUND: Although previous studies have separately revealed that parameters such as anxiety, depression, and secondary traumatic stress (STS) are associated with burnout, there is still a limited understanding of the relationship between anxiety, depression, and STS and burnout in intensive care unit (ICU) nurses. AIMS: To investigate the relationship between levels of burnout, anxiety, depression, and STS in ICU nurses. METHOD: A cross-sectional study was conducted with ICU nurses ( N = 164) from a university hospital in eastern Turkey. The participants completed the anxiety, depression, STS, and burnout scales along with the descriptive characteristics form. The data were analyzed using descriptive statistics, correlation, and logistic regression analysis. RESULTS: The mean scores for STS, anxiety, depression, and burnout were 40.60 ± 13.77, 17.14 ± 12.90, 13.28 ± 9.75 and 41.39 ± 14.87, respectively. The results showed that, in the ICU nurses, anxiety, depression, and STS components explained 61% of emotional exhaustion, 38% of depersonalization, and 13% of personal accomplishment. CONCLUSIONS: While the present findings supported the paradigm that burnout in ICU nurses is associated with STS, anxiety, and depression, they also revealed some details about the psychopathological factors associated with burnout. These details were as follows: (1) individuals who resorted to avoidance as a component of STS on a high level were more likely to experience emotional exhaustion and depersonalization, (2) individuals with severe depressive symptoms were more likely to experience a decrease in their personal accomplishment, and (3) individuals with anxiety symptoms were more likely to experience both emotional exhaustion and personal accomplishment.


2020 ◽  
Vol 10 (4) ◽  
pp. 72
Author(s):  
Mohamed E. Abdelgawad ◽  
Nadia T. Ahmed ◽  
Ahmed M. Elmenshawy

Background and objective: Electrolyte disturbances remain a common lifesaving issue in the intensive care units. They are associated with increased morbidity and mortality. They are mostly resulted secondary to critical illness itself or associated treatment modalities. Therefore, electrolytes repletion should be done effectively and timely. This could be ensured using nurse driven protocols rather than traditional methods of repletion. These protocols are nurse initiated and collaboratively developed. They have been shown to improve patient care outcomes through the provision of high quality care. They are increasingly being used in the critical care setting. Objective: Determine the effect of applying nurses driven electrolytes repletion protocol on electrolytes disturbance control among critically ill patients.Methods: Quasi experimental research design was used. Sixty two critically ill patients with electrolytes loss were enrolled in the study at Alexandria Main University Hospital intensive care units, Egypt. All episodes of electrolyte loss were evaluated. Repletion of electrolyte loss was done according to unit routine for the control group and nurses driven electrolytes repletion protocol for the study group. Episodes of electrolyte disturbances, adverse events and timing of repletion were evaluated.Results: Neurological disorders represent the most encountered diagnosis. The most common cause of electrolyte loss in was the use of diuretics. Furthermore, there was a highly statistical difference between the two groups as regard electrolytes levels, effectiveness and timing of replacement.Conclusions: Application of nurses driven electrolyte repletion protocol resulted in improvements in the effectiveness and timeliness of electrolyte replacement.


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Persona Paolo ◽  
Valeri Ilaria ◽  
Zarantonello Francesco ◽  
Forin Edoardo ◽  
Sella Nicolò ◽  
...  

Abstract Background During COVID-19 pandemic, optimization of the diagnostic resources is essential. Lung Ultrasound (LUS) is a rapid, easy-to-perform, low cost tool which allows bedside investigation of patients with COVID-19 pneumonia. We aimed to investigate the typical ultrasound patterns of COVID-19 pneumonia and their evolution at different stages of the disease. Methods We performed LUS in twenty-eight consecutive COVID-19 patients at both admission to and discharge from one of the Padua University Hospital Intensive Care Units (ICU). LUS was performed using a low frequency probe on six different areas per each hemithorax. A specific pattern for each area was assigned, depending on the prevalence of A-lines (A), non-coalescent B-lines (B1), coalescent B-lines (B2), consolidations (C). A LUS score (LUSS) was calculated after assigning to each area a defined pattern. Results Out of 28 patients, 18 survived, were stabilized and then referred to other units. The prevalence of C pattern was 58.9% on admission and 61.3% at discharge. Type B2 (19.3%) and B1 (6.5%) patterns were found in 25.8% of the videos recorded on admission and 27.1% (17.3% B2; 9.8% B1) on discharge. The A pattern was prevalent in the anterosuperior regions and was present in 15.2% of videos on admission and 11.6% at discharge. The median LUSS on admission was 27.5 [21–32.25], while on discharge was 31 [17.5–32.75] and 30.5 [27–32.75] in respectively survived and non-survived patients. On admission the median LUSS was equally distributed on the right hemithorax (13; 10.75–16) and the left hemithorax (15; 10.75–17). Conclusions LUS collected in COVID-19 patients with acute respiratory failure at ICU admission and discharge appears to be characterized by predominantly lateral and posterior non-translobar C pattern and B2 pattern. The calculated LUSS remained elevated at discharge without significant difference from admission in both groups of survived and non-survived patients.


Sign in / Sign up

Export Citation Format

Share Document