scholarly journals Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy

2021 ◽  
Vol 17 (1) ◽  
Author(s):  
Franziska C. Wagner ◽  
Sven Reese ◽  
Kerstin Gerlach ◽  
Peter Böttcher ◽  
Christoph K. W. Mülling

Abstract Background Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. Results A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. Conclusion In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs.

Author(s):  
Mark Kimball

Abstract This article presents a novel tool designed to allow circuit node measurements in a radio frequency (RF) integrated circuit. The discussion covers RF circuit problems; provides details on the Radio Probe design, which achieves an input impedance of 50Kohms and an overall attenuation factor of 0 dB; and describes signal to noise issues in the output signal, along with their improvement techniques. This cost-effective solution incorporates features that make it well suited to the task of differential measurement of circuit nodes within an RF IC. The Radio Probe concept offers a number of advantages compared to active probes. It is a single frequency measurement tool, so it complements, rather than replaces, active probes.


2019 ◽  
Vol 1425 ◽  
pp. 012195
Author(s):  
S F Noller ◽  
A Pfennig ◽  
R Heiler
Keyword(s):  

2021 ◽  
Vol 11 (6) ◽  
pp. 2563
Author(s):  
Ivan Grgić ◽  
Vjekoslav Wertheimer ◽  
Mirko Karakašić ◽  
Željko Ivandić

Recent soft tissue studies have reported issues that occur during experimentation, such as the tissue slipping and rupturing during tensile loads, the lack of standard testing procedure and equipment, the necessity for existing laboratory equipment adaptation, etc. To overcome such issues and fulfil the need for the determination of the biomechanical properties of the human gracilis and the superficial third of the quadriceps tendons, 3D printed clamps with metric thread profile-based geometry were developed. The clamps’ geometry consists of a truncated pyramid pattern, which prevents the tendons from slipping and rupturing. The use of the thread application in the design of the clamp could be used in standard clamping development procedures, unlike in previously custom-made clamps. Fused deposition modeling (FDM) was used as a 3D printing technique, together with polylactic acid (PLA), which was used as a material for clamp printing. The design was confirmed and the experiments were conducted by using porcine and human tendons. The findings justify the usage of 3D printing technology for parts manufacturing in the case of tissue testing and establish independence from the existing machine clamp system, since it was possible to print clamps for each prepared specimen and thus reduce the time for experiment setup.


1965 ◽  
Vol 36 (8) ◽  
pp. 1262-1262
Author(s):  
Glenn E. Fulmer ◽  
James F. Light ◽  
John F. Arnreich
Keyword(s):  

2014 ◽  
Vol 2014 ◽  
pp. 1-8
Author(s):  
Mayu Muramatsu ◽  
Motomichi Koyama ◽  
Ikumu Watanabe

We analyzed the dynamic recrystallization of pure lead by tensile testing with cyclic strain holding at room temperature. The specimens were held at an identical strain and subsequently reloaded, providing the strength before and after the strain holding process. The difference in strength enables factors affecting dynamic recrystallization behavior to be analyzed through mechanical testing. For instance, the effects of strain rate on dynamic recrystallization were analyzed by comparing the results obtained from tensile tests with and without strain holding. This experimental technique demonstrated some parts of contribution of elastic strain, dynamic recovery, dynamic recrystallization, and necking to stress-strain responses.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Madison E. Wale ◽  
Derek Q. Nesbitt ◽  
Bradley S. Henderson ◽  
Clare K. Fitzpatrick ◽  
Jaremy J. Creechley ◽  
...  

Abstract Tensile testing is an essential experiment to assess the mechanical integrity of musculoskeletal soft tissues, yet standard test methods have not been developed to ensure the quality and reproducibility of these experiments. The ASTM International standards organization has created tensile test standards for common industry materials that specify geometric dimensions of test specimens (coupons) that promote valid failures within the gage section (midsubstance), away from the grips. This study examined whether ASTM test standards for plastics, elastomers, and fiber-reinforced composites are suitable for tensile testing of bovine meniscus along the circumferential fiber direction. We found that dumbbell (DB) shaped coupons based on ASTM standards for elastomers and plastics had an 80% and 60% rate of midsubstance failures, respectively. The rate of midsubstance failures dropped to 20% when using straight (ST) coupons based on ASTM standards for fiber-reinforced composites. The mechanical properties of dumbbell shaped coupons were also significantly greater than straight coupons. Finite element models of the test coupons revealed stress distributions that supported our experimental findings. In addition, we found that a commercial deli-slicer was able to slice meniscus to uniform layer thicknesses that were within ASTM dimensional tolerances. This study provides methods, recommendations, and insights that can advance the standardization of tensile testing in meniscus and other soft fibrous tissues.


2016 ◽  
Vol 46 (4) ◽  
pp. 3-18
Author(s):  
Venelin S. Jivkov ◽  
Evtim V. Zahariev

Abstract The paper presents a geometrical approach to dynamics simulation of a rigid and flexible system, compiled of high speed rotating machine with eccentricity and considerable inertia and mass. The machine is mounted on a vertical flexible pillar with considerable height. The stiffness and damping of the column, as well as, of the rotor bearings and the shaft are taken into account. Non-stationary vibrations and transitional processes are analyzed. The major frequency and modal mode of the flexible column are used for analytical reduction of its mass, stiffness and damping properties. The rotor and the foundation are modelled as rigid bodies, while the flexibility of the bearings is estimated by experiments and the requirements of the manufacturer. The transition effects as a result of limited power are analyzed by asymptotic methods of averaging. Analytical expressions for the amplitudes and unstable vibrations throughout resonance are derived by quasi-static approach increasing and decreasing of the exciting frequency. Analytical functions give the possibility to analyze the influence of the design parameter of many structure applications as wind power generators, gas turbines, turbo-generators, and etc. A numerical procedure is applied to verify the effectiveness and precision of the simulation process. Nonlinear and transitional effects are analyzed and compared to the analytical results. External excitations, as wave propagation and earthquakes, are discussed. Finite elements in relative and absolute coordinates are applied to model the flexible column and the high speed rotating machine. Generalized Newton - Euler dynamics equations are used to derive the precise dynamics equations. Examples of simulation of the system vibrations and nonstationary behaviour are presented.


2004 ◽  
pp. 1-12

Abstract Tensile tests are performed for several reasons. The results of tensile tests are used in selecting materials for engineering applications. Tensile properties often are used to predict the behavior of a material under forms of loading other than uniaxial tension. Elastic properties also may be of interest, but special techniques must be used to measure these properties during tensile testing, and more accurate measurements can be made by ultrasonic techniques. This chapter provides a brief overview of some of the more important topics associated with tensile testing. These include tensile specimens and test machines; stress-strain curves, including discussions of elastic versus plastic deformation, yield points, and ductility; true stress and strain; and test methodology and data analysis.


Author(s):  
Liao Dao-Xun ◽  
Lu Yong-Zhong ◽  
Huang Xiao-Cheng

Abstract The multilayer vibration isolation system has been widely applied to isolate vibration in dynamic devices of ships, high-speed vehicles forging hammer and precise instruments. The paper is based on the coordinate transformation of space general motion for mass blocks (rigid bodies) and Lagrangian equation of multilayer vibration isolation system. It gives a strict mathematical derivation on the differential equation of the motion for the system with six degrees of freedom of relative motion between mass blocks (including base). The equations are different from the same kind of equations in the reference literatures. It can be used in the floating raft of ships in order to isolates vibration and decrease noise, also used in design calculation of the multilayer vibration isolation for dynamic machines and precise instruments on the dry land.


Sign in / Sign up

Export Citation Format

Share Document