Reliability and interrelationships between maximal oxygen intake, physical work capacity and step-test scores in college women

1972 ◽  
Vol 4 (4) ◽  
pp. 182???186 ◽  
Author(s):  
WILLIAM D. McARDLE ◽  
FRANK I. KATCH ◽  
GARY S. PECHAR ◽  
LONI JACOBSON ◽  
SHELLEY RUCK
Author(s):  
I. P. Zaitseva ◽  
V. N. Tsygan ◽  
A. E. Kim

Purpose of the study: to study the effect of Vitrum in combination with adaptogens on immunological reactivity and physical performance in athletes under conditions of intense training.Materials and methods: 4 groups of athletes, 10 people in each, went through a cycle of intensive training according to a specially developed methodology. Group I took Vitrum, group II — Vitrum + Eleutherococcus extract, group III — Vitrum + ginseng tincture. Group IV — ascorbic acid and was used as a control. Blood for analysis was taken from the cubital vein before and after 28 days of drug administration. Indicators of immunological reactivity were determined by modern laboratory methods. Physical performance was determined by the index of the Harvard step test (IHST) and the PWC170 test.Results: the use of Vitrum in combination with adaptogens promotes a significant increase in the parameters of humoral (increase in IgA by 32–40 %, IgM by 28–43 %, IgG by 9–14 %) and cellular (increasing the completeness of phagocytosis by 9–37 % immunity.Conclusions: intake of Vitrum in combination with adaptogens was accompanied by a significant increase in nonspecific immunity and increased the level of fitness.


PEDIATRICS ◽  
1963 ◽  
Vol 32 (4) ◽  
pp. 742-756
Author(s):  
R. A. Bruce ◽  
J. R. Blackmon ◽  
J. W. Jones ◽  
G. Strait

1. Several approaches to assessment of physical work capacity in the upright posture in normal adults and cardiac patients have been reviewed critically. 2. Preliminary experience has been presented with a new multistage treadmill test of maximal exercise which permits appraisal of either a physically trained normal subject or an impaired but ambulatory cardiac patient. 3. The most effective means of differentiating cardiacs from normals has been an estimate of the total oxygen intake/Kg of body weight. 4. The need for monitoring the circulation with respect to arrhythmias, ischemia and/or hypotension has been emphasized. The authors wish to acknowledge their appreciation of many physicians, particularly Dr. Robert M. Levenson of the Seattle Cardiac Work Evaluation Clinic, and medical and graduate students who have assisted in the testing of patients and normals. The assistance of Mrs. Gladys Pettet is gratefully acknowledged also.


Author(s):  
M Bahrami ◽  
F Qanai ◽  
J Mirmohammadi ◽  
M Askarishahi ◽  
A Barkhordari ◽  
...  

Introduction: Estimation of the maximum aerobic capacity to find a physiological fitness between worker and the work is of great importance. The purpose of this study was to estimate the highest aerobic capacity and physical work capacity of tile and ceramic workers. Materials and methods: In this cross-sectional study, 90 workers were randomly selected from tile and ceramic workers in Yazd. A questionnaire consisting of two parts was used as data collection tool. The first part of the questionnaire included demographic characteristics completed by the interview. In the second part, parameters including height, weight, BMI and heart rate were inserted in the questionnaire. The Queen step test was used to measure the maximum aerobic capacity. The data were analyzed by SPSS software using Mann-Whitney and Kruskal-Wallis tests and Spearman,s test. Results: The maximum aerobic capacity in tile and ceramic workers was estimated to be 3.60±.0.03 L/m. The results showed that aerobic capacity was significantly correlated with weight and body mass index. Also, there was no significant relationship between aerobic capacity, smoking and exercise, and education, but there was a significant relationship between gob title and aerobic capacity. Conclusion: Weight, BMI and type of occupation affect the aerobic capacity of workers.


1961 ◽  
Vol 16 (1) ◽  
pp. 153-156 ◽  
Author(s):  
Theodor Hettinger ◽  
Newton C. Birkhead ◽  
Steven M. Horvath ◽  
Bela Issekutz ◽  
Kaare Rodahl

Maximal oxygen uptakes were compared with the results from five different tests of physical work capacity in 96 men, 23–62 years of age. In addition, the 'predicted' maximal oxygen uptakes, according to the Ǻstrand-Ryhming nomogram, were compared with the actual measured maximal oxygen uptakes in the 28 subjects who were between 20 and 30 years of age. There was a statistically significant correlation between the maximal oxygen uptake and the following tests: the Harvard step test (P < .001); a new modified step test in which adjustments were made for the body weight and the length of the legs of the subject (P < .001); the Master step test (P < .05); and the Amplituden-Puls-Frequenz test, (P < .02). There was no statistically significant correlation between the maximal oxygen uptake and the Leistungs-Pulsindex. The correlation between the predicted maximal oxygen uptake and the measured maximal oxygen uptake was statistically significant at the .01 level. Submitted on May 16, 1960


2005 ◽  
Vol 1280 ◽  
pp. 156-160 ◽  
Author(s):  
J. Bugajska ◽  
T. Makowiec-Dąbrowska ◽  
A. Jegier ◽  
A. Marszałek

1980 ◽  
Vol 48 (6) ◽  
pp. 1060-1064 ◽  
Author(s):  
R. M. Glaser ◽  
M. N. Sawka ◽  
M. F. Brune ◽  
S. W. Wilde

The purpose of this investigation was to compare physical work capacity (PWC), peak oxygen uptake (peak VO2), maximal pulmonary ventilation (VEmax), maximal heart rate (HRmax), and maximal blood lactate concentration (LAmax) for wheelchair ergometer (WERG) and arm crank ergometer (ACE) exercise. For this, wheelchair-dependent (n = 6) and able-bodied (n = 10) subjects completed a progressive intensity, discontinuous test for each mode of exercise. Each test was terminated by physical exhaustion and/or an inability to maintain a flywheel velocity of 180 m.min-1. Relatively high correlation coefficients were found between values obtained during the two modes of ergometry for PWC, peak VO2, VEmax, and HRmax. WERG exercise was found to elicit a significantly (P less than 0.05) lower PWC (by 36%), HRmax (by 7%), and LAmax (by 26%) than ACE exercise. Peak VO2 and VEmax, however, were similar for both exercise modes. These data suggest that either exercise mode may be used for fitness testing and training of people who cannot use their legs and that arm cranking may be a superior method to propel wheelchairs.


1987 ◽  
Vol 31 (12) ◽  
pp. 1331-1335
Author(s):  
Jeffrey E. Fernandez ◽  
Robert J. Marley ◽  
Nancy B. Stubbs

A laboratory experiment using 15 male subjects was conducted to document lifting physical work capacity over the frequency range of 2 to 12 lifts per minute and to compare these values to bicycling physical work capacity. Results indicate that bicycling PWC is significantly higher than lifting PWC at the 0.05 level. A variation in lifting PWC as a function of frequency was observed. This could be attributed to lifting technique. Task design should, therefore, not only consider lifting PWC but also the frequency of lift.


2021 ◽  
Author(s):  
Josh Foster ◽  
James W Smallcombe ◽  
Simon G Hodder ◽  
Andreas D Flouris ◽  
Lars Nybo ◽  
...  

It is well-known that heat impacts human labour/physical work capacity (PWC), but systematic evaluations of solar radiation (SOLAR) effects and the interaction with air temperature and humidity levels and clothing are lacking, as most lab-studies are conducted in semi-nude subjects without radiation or only in a single climatic condition. Due to the high relevance of SOLAR in various occupations, this study quantified how SOLAR interacts with clothing and other primary environmental factors (air temperature/humidity) of importance to determine PWC in the heat. The data allowed the development of a SOLAR correction factor for predicting PWC in major outdoor industries. Fourteen young adult males (7 wearing a standardised work coverall (0.9 Clo), 7 with shorts and trainers (0.3 Clo) walked for 1-hour at a fixed heart rate of 130 b∙min-1, in seven combinations of air temperature (25 to 45 Celsius) and relative humidity (20 or 80%), with and without SOLAR (800 W/m2 from solar lamps). Cumulative energy expenditure in the heat, relative to the work achieved in a cool reference condition, was used to determine PWC%. Skin temperature was the primary determinant of PWC in the heat. In dry climates with exposed skin (0.3 Clo), SOLAR caused PWC to decrease exponentially with rising air temperature, whereas work coveralls (0.9 Clo) negated this effect. In humid conditions, the SOLAR-induced reduction in PWC was consistent and linear across all levels of air temperature, and clothing conditions. WBGT and UTCI based prediction equations of PWC represented SOLAR correctly. For heat indices not intrinsically accounting for SOLAR, correction factors are provided enabling forecasting of heat effects on work productivity.


Sign in / Sign up

Export Citation Format

Share Document