scholarly journals Low Cost Solar Powered Telecenters for Malaysian Rural Areas: Case Study in Pos Sinderut, Pahang, Malaysia

2019 ◽  
Vol 7 (4.14) ◽  
pp. 421
Author(s):  
M. D. Ibrahim ◽  
S. Zainal ◽  
A. K. Othman

The main objective of this project is to design and analyze the cost benefits solar PV system for rural telecenter. The project focused on designing the main solar system and solar panel energy performance based on translucency. The task that was carried out in this project was the selection of the suitable system that will suit the operation well while keeping the design cost as low as possible. In this project, the design of the solar panel system was focused on the electric loads and its cost benefit. Homer software was used to evaluate the solar panel system. Meant for ways of communications for indigenous people, the Solar Photovoltaic system is one of the popular solution for off-grid rural community power supply. The optimized combination for a particular rural site can be predicted based on NASA’s data of Solar Global Horizontal Irradiance (GHI). In this project, Pos Sinderut was chosen as the site, and the data load was measured. In our preliminary findings, it was found that the model on site was not suitably designed and maintained. The data parameters that was used for the on-site installed model was also not possible to be calculated when the model was simulated using Homer Software. As a result, we proposed a new model design by optimizing the load of VSAT and charging station based on the amount of solar PV and batteries that was supplied. This paper shows the significance of preliminary designs based on the irradiance and the usage load of the specific site before any installation should be commenced. It also showed how the site should be maintained properly in order to ensure a chosen site is sustainable for the rural community, post-installation.  

Electronics ◽  
2018 ◽  
Vol 7 (7) ◽  
pp. 119 ◽  
Author(s):  
Muhammad Khan ◽  
Kamran Zeb ◽  
Waqar Uddin ◽  
P. Sathishkumar ◽  
Muhammad Ali ◽  
...  

Environment protection and energy saving are the most attractive trends in zero-carbon buildings. The most promising and environmentally friendly technique is building integrated photovoltaics (BIPV), which can also replace conventional buildings based on non-renewable energy. Despite the recent advances in technology, the cost of BIPV systems is still very high. Hence, reducing the cost is a major challenge. This paper examines and validates the effectiveness of low-cost aluminum (Al) foil as a reflector. The design and the performance of planer-reflector for BIPV systems are analyzed in detail. A Bi-reflector solar PV system (BRPVS) with thin film Al-foil reflector and an LLC converter for a BIPV system is proposed and experimented with a 400-W prototype. A cadmium–sulfide (CdS) photo-resistor sensor and an Arduino-based algorithm was developed to control the working of the reflectors. Furthermore, the effect of Al-foil reflectors on the temperature of PV module has been examined. The developed LLC converter confirmed stable output voltage despite large variation in input voltage proving its effectiveness for the proposed BRPVS. The experimental results of the proposed BRPVS with an Al-reflector of the same size as that of the solar PV module offered an enhancement of 28.47% in the output power.


2018 ◽  
Vol 19 (4) ◽  
pp. 790-816 ◽  
Author(s):  
Paula Fonseca ◽  
Pedro Moura ◽  
Humberto Jorge ◽  
Aníbal de Almeida

Purpose The purpose of this study was to design a renovation plan for a university campus building (Department of Electrical and Computer Engineering) with the aim to achieve nearly zero energy performance, ensuring a low specific demand (lower than 44 kWh/m2) and a high level of on-site renewable generation (equivalent to more than 20 per cent of the energy demand). Design/methodology/approach The baseline demand was characterized based on energy audits, on smart metering data and on the existing building management system data, showing a recent reduction of the electricity demand owing to some implemented measures. The renovation plan was then designed with two main measures, the total replacement of the actual lighting by LEDs and the installation of a photovoltaic system (PV) with 78.8 kWp coupled with an energy storage system with 100 kWh of lithium-ion batteries. Findings The designed renovation achieved energy savings of 20 per cent, with 27.5 per cent of the consumed energy supplied by the PV system. This will ensure a reduction of the specific energy of the building to only 30 kWh/m2, with 42.4 per cent savings on the net-energy demand. Practical implications The designed renovation proves that it is possible to achieve nearly zero energy goals with cost-effective solutions, presenting the lighting renovation and the solar PV generation system a payback of 2.3 and 6.9 years, respectively. Originality/value This study innovated by defining ambitious goals to achieve nearly zero energy levels and presenting a design based on a comprehensive lighting retrofit and PV generation, whereas other studies are mostly based on envelope refurbishment and behaviour changes.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Abraham Hizkiel Nebey ◽  
Biniyam Zemene Taye ◽  
Tewodros Gera Workineh

The majority of the Ethiopian population lives in rural areas and uses wood for domestic energy consumption. Using wood and fuel for domestic uses accounts for deforestation and health problems, which is also dangerous for the environment. The Ethiopian government has been planning to generate power from available renewable resources around the community. Therefore, determining the water surface potential of energy harvesting with floating solar photovoltaic system by using geographic information system is used to support decision-makers to use high potential areas. To identify useable areas for floating solar photovoltaic, factors that affect the usability were identified and weighted by using Analytical Hierarchy Processes. Thus, weighted values and reclassified values were multiplied to do the final usability map of floating solar photovoltaic with ArcGIS software. Due to the improper location of floating solar photovoltaic, efficiency is dropped. Therefore, the objective of this study was to identify the most usable surface of water bodies in Amhara regional, state irrigation dams for generating electrical power. The usability of the water surface for floating solar photovoltaic power plant was 63.83%, 61.09%, and 57.20% of Angereb, Rib, and Koga irrigation dams, respectively. The majority of the usable areas were found in the middle of the water surface. Nature water surface is a key factor in generating solar energy; it affects the floating solar photovoltaic and irradiance coming to the solar photovoltaic panel surface.


2016 ◽  
Vol 5 (1-2) ◽  
pp. 162-170
Author(s):  
Henrik Zsiborács ◽  
Béla Pályi ◽  
Gábor Pintér ◽  
Nóra Hegedűsné Baranyai ◽  
Péter Szabó ◽  
...  

In this paper the economic aspects of the water spraying cooling technology of polycrystalline solar modules with respect to the effect of temperature on performance was examined. The main purpose of this work was to explore the economic relations of the spraying cooling technology of solar modules. In the study 5 kW PV system for residential customers, 5 kW and 50 kW PV system for business customer were studied. In Hungarian climatic conditions, considering the inflation values used, the interest rate, the annual utilization of the cooling system, the expected profit and the maintenance costs show us that neither of the cooling solutions is capable of better payback time than the reference uncooled solar PV system. The further research goal is to determine the usability of the cooling system in such countries which have on the one hand more ideal climatic conditions, on the other hand more predictable green energy feed regulations.


Author(s):  
Yuwono Bimo Purnomo ◽  
F. Danang Wijaya ◽  
Eka Firmansyah

In a standalone photovoltaic (PV) system, a bidirectional DC converter (BDC) is needed to prevent the battery from damage caused by DC bus voltage variation. In this paper, BDC was applied in a standalone solar PV system to interface the battery with a DC bus in a standalone PV system. Therefore, its bidirectional power capability was focused on improving save battery operation while maintaining high power quality delivery. A non-isolated, buck and boost topology for the BDC configuration was used to interface the battery with the DC bus. PID controller-based control strategy was chosen for easy implementation, high reliability, and high dynamic performance. A simulation was conducted using MATLAB Simulink program. The simulation results show that the implementation of the BDC controller can maintain the DC bus voltage to 100 V, have high efficiency at 99.18% in boost mode and 99.48% in buck mode. To prevent the battery from overcharging condition, the BDC stops the charging process and then works as a voltage regulator to maintain the DC bus voltage at reference value.


Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5840
Author(s):  
Bat-Erdene Bayandelger ◽  
Yuzuru Ueda ◽  
Amarbayar Adiyabat

There are approximately 200,000 households living in detached houses and gers (yurts) with small coal stoves that burn raw coal in Ulaanbaatar city. A proper heating system and improvement of the energy efficiency of residential dwellings are vitally important for Ulaanbaatar city to reduce air pollution as well as for the operation of the current central energy system. This study shows the experimental results for two gers with two different heating systems and different thermal insulation, for investigating the merits of each. The technical feasibility of the system consisting of an electric thermal storage (ETS) heater with a daytime charging schedule and areal photovoltaic (PV) system was also examined by using a simulation with software developed in MATLAB (R2020a, MathWorks, USA). As a result of the experiment, the indoor comfort level and energy efficiency of the ger with added insulation and an ETS heater with nighttime charging were shown to be enhanced compared with those of the reference ger. The ger with added insulation and the ETS heater consumed 3169 kWh for electric appliances and 5989 kWh for the heating season. The simulation showed that the PV self-consumption rate is 76% for the Ger 2 with the ETS heater because of the daytime charging schedule of the ETS heater. The PV system supplied 31% of the total energy consumed, with the remaining 69% from the main grid.


2018 ◽  
Vol 225 ◽  
pp. 04004
Author(s):  
Tan Dei Han ◽  
Mohamad Rosman M. Razif ◽  
Shaharin A. Sulaiman

Solar photovoltaic (PV) systems has the potential of supplying infinite electricity from renewable energy to rural areas around Malaysia. Various preterm failures happening frequently on the system lead to its drop in efficiency and breakdown. Lack of studies on the system in Malaysia hinders the development in terms of operation and maintenance. There is no proper documentation relevant to the premature failure of the system in Malaysia. The main objective of this project is to study the nature of premature failure of stand-alone solar photovoltaic system in Malaysia in order to improve the operation and maintenance of the system. The present study would provide reference for proper planning on operation and maintenance of the PV system. The study was conducted base on expert’s input and extensive literature survey. FMEA method and ISM approach are applied to analyze the data collected. Poor cooling system have the highest risk priority number. Poor workmanship is the least depending factor for premature failure to happen thus requires most attention. Highest driving force of premature failure is poor monitoring and maintenance. More focus should be given to these premature failure during the planning for operation and maintenance due to its severity and impact.


2020 ◽  
Vol 186 ◽  
pp. 01004
Author(s):  
Pathomthat Chiradeja ◽  
Atthapol Ngaopitakkul

Renewable energy especially solar energy has become a significant part in electrical power generation with its advantage in the environmentally friendly and current trend of decrease in installation cost. The photovoltaic (PV) system on a rooftop is one of the power generating system based on renewable energy that can fit building to utilize space efficiently. This paper is analyzing the feasibility of installing a solar PV rooftop on the building using a case study building located in Bangkok, Thailand. The performance will be evaluated in term of both energy and economic perspective. The comparison with Thailand building energy code also been done to show that overall energy consumption with PV system complies with the law. The result has shown that with rooftop photovoltaic system installation, annual energy consumption in the building can be reduced significantly and it can achieve feasibility in term of economic perspective.


2011 ◽  
Vol 356-360 ◽  
pp. 2393-2398
Author(s):  
Qi Qi Wei ◽  
Bei Yue Tan

photovoltaic system, optimum tilted angle, siphon principle, water treatment Abstract. Based on the recent research at home and abroad and the local meteorological data, this study aims to determine the optimum tilt angle of the solar-cell array surface and the best month on the system to achieve the optimal design of PV system. Full mechanical automatic control system is designed by using lever principle and siphon principle to realize the purpose of all-day and maintenance-free operational situation. It can replace the motor control system and at the same time,enjoys reliability, low cost, long life and energy conservation. The indoor and local river data of the experiment shows that this system has an evident effect on water decontamination. Furthermore, comparing with traditional aeration system. It has many advantages, for instance, it can save more than 20 thousand and carbon emission can be reduced by 683 ton and other aspects.


Author(s):  
K. Agyenim-Boateng ◽  
R. F. Boehm

The promise of large-scale use of renewables such as wind and solar for supplying electrical power is tempered by the sources’ transient behavior and the impact this would have on the operation of the grid. One way of addressing this is through the use of supplemental energy storage. While the technology for the latter has not been proven on a large scale or to be economical at the present time, some assessments of what magnitude is required can be made. In performing this work we have used NREL’s Solar Advisor Model (SAM 2010) with TMY3 solar data to estimate the photovoltaic system power generation. Climatic conditions close to load centers were chosen for the simulations. Then the PV output for varying sizes of arrays were examined and the impact of varying amounts of storage investigated. The storage was characterized by maximum limiting energy and power capacities based on annual hourly peak load, as well as its charging and discharging efficiencies. The simulations were performed using hourly time steps with energy withdrawn from, or input to, storage only after considering base generation and the PV system output in serving the grid load. In this work, we examined the load matching capability of solar PV generation (orientated for maximum summer output) for a sample Southwestern US utility grid load of 2008. Specifically we evaluated the daily and seasonal peak load shifting with employing varying storage capacities. The annual average energy penetration based on the usable solar PV output is also examined under these conditions and at different levels of system flexibility.