SHEAR REPAIRED RC BEAM BY FRP BONDING WITH EXTERNAL POST-TENSIONING

Author(s):  
Rumana Choudhury ◽  
T.G. Suntharavaivel ◽  
Nirmal Mandal

Various factors, including increase in traffic volume and weight, structural aging, and environmental impact, cause damage in structural members. This raises the importance of the maintenance, rehabilitation, and strengthening of reinforced concrete members. External post-tensioning is one of the widely-used strengthening techniques in many countries due to its advantages over other strengthening methods. Although flexural strengthening of existing structural members is a well-established method, shear strengthening of structural members, especially with existing shear cracks, has attained very little attention from researchers. Similarly, external fiber-reinforced polymer (FRP) bonding for shear strengthening of structural members, especially with existing shear cracks, is a relatively new area of research. This paper presents the results of an experimental study on the shear strengthening of reinforced concrete (RC) beams with existing shear cracks by external post-tensioning and external FRP bonding. The test result showed that the combined strengthening technique of external post-tensioning and external FRP bonding can effectively increase the shear capacity of RC beams with existing shear cracks.

Buildings ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 520
Author(s):  
Daniel A. Pohoryles ◽  
Jose Melo ◽  
Tiziana Rossetto

Due to inadequacies of reinforcement design in older structures and changes in building codes, but also the change of building use in existing structures, reinforced concrete (RC) beams often require upgrading during building renovation. The combined shear and flexural strengthening with composite materials, fibre-reinforced polymer sheets (FRP) and textile reinforced mortars (TRM), is assessed in this study. An experimental campaign on twelve half-scale retrofitted RC beams is presented, looking at various parameters of interest, including the effect of the steel reinforcement ratio on the retrofit effectiveness, the amount of composite material used for strengthening and the effect of the shear span, as well as the difference in effectiveness of FRP and TRM in strengthening RC beams. Significant effects on the shear capacity of composite retrofitted beams are observed for all studied parameters. The experimental study is used as a basis for developing a detailed finite element (FE) model for RC beams strengthened with FRP. The results of the FE model are compared to the experimental results and used to design a parametric study to further study the effect of the investigated parameters on the retrofit effectiveness.


10.14311/800 ◽  
2006 ◽  
Vol 46 (1) ◽  
Author(s):  
M. A. A. Saafan

The objective of the experimental work described in this paper was to investigate the efficiency of GFRP composites in strengthening simply supported reinforced concrete beams designed with insufficient shear capacity. Using the hand lay-up technique, successive layers of a woven fiberglass fabric were bonded along the shear span to increase the shear capacity and to avoid catastrophic premature failure modes. The strengthened beams were fabricated with no web reinforcement to explore the efficiency of the proposed strengthening technique using the results of control beams with closed stirrups as a  web reinforcement. The test results of 18 beams are reported, addressing the influence of different shear strengthening schemes and variable longitudinal reinforcement ratios on the structural behavior. The results indicated that significant increases in the shear strength and improvements in the overall structural behavior of beams with insufficient shear capacity could be achieved by proper application of GFRP wraps.


Author(s):  
Muhammad Imran Rafiq ◽  
Ameer Baiee

Strengthening of reinforced concrete (RC) structures is often necessary due to the change of using or to enhance the strength of deteriorated existing RC structures attributed to aging and environmental effects. Interfacial bond between the existing RC member and the strengthening layer is known to be the main factor for any successful strengthening technique. This study investigates the efficiency of utilizing high strength cementitious connectors in preventing the debonding of textile reinforced mortar (TRM) strengthening layer from substrate concrete of RC beams. An experimental program is developed to investigate the effect of strength of mortars and the distribution of cementitious connectors on the behavior of the strengthened beams. TRM comprising eight and sixteen textile basalt fiber layers were utilized in these experiments. The results demonstrate the effectiveness of cementitious connectors on the failure mode of strengthened beams by means of controlling the debonding of TRM. The increase in cracking and ultimate loads is demonstrated due to the strengthening of RC beams using TRM.


Fibers ◽  
2020 ◽  
Vol 8 (2) ◽  
pp. 13 ◽  
Author(s):  
Constantin E. Chalioris ◽  
Adamantis G. Zapris ◽  
Chris G. Karayannis

The application of externally bonded fiber-reinforced polymer (EB-FRP) as shear transverse reinforcement applied in vulnerable reinforced concrete (RC) beams has been proved to be a promising strengthening technique. However, past studies revealed that the effectiveness of this method depends on how well the reinforcement is bonded to the concrete surface. Thus, although the application of EB-FRP wrapping around the perimeter of rectangular cross-sections leads to outstanding results, U-jacketing in shear-critical T-beams seems to undergo premature debonding failures resulting in significant reductions of the predictable strength. In this work, five shear-critical RC beams with T-shaped cross-section were constructed, strengthened and tested in four-point bending. Epoxy bonded carbon FRP (C-FRP) sheets were applied on the three sides and along the entire length of the shear-strengthened T-beams as external transverse reinforcement. Furthermore, the potential enhancement of the C-FRP sheets anchorage using bolted steel laminates has been examined. Test results indicated that although the C-FRP strengthened beams exhibited increased shear capacity, the brittle failure mode was not prevented due to the debonding of the FRP from the concrete surface. Nevertheless, the applied mechanical anchor of the C-FRP sheets delayed the debonding. Moreover, the design provisions of three different code standards (Greek Code of Interventions, Eurocode 8 and ACI Committee 440) concerning the shear capacity of T-shaped RC beams retrofitted with EB-FRP jackets or strips in U-jacketing configuration are investigated. The ability of these code standards to predict safe design estimations is checked against 165 test data from the current experimental project and data available in the literature.


2012 ◽  
Vol 455-456 ◽  
pp. 1079-1083
Author(s):  
Wei Jun Yang ◽  
Hong Jia Huang ◽  
Wen Yu Jiang ◽  
Yi Bin Peng

Shantou atmospheric salt-fog environment is simulated with the comprehensive salt spray test chamber. By using reinforced concrete short beams under different water-cement radio, different corrosion time, the inclined section degradation rules of the corrosive reinforced concrete members are researched for establishing shear capacity of short beam formulas in salt-fog environment.


2006 ◽  
Vol 33 (6) ◽  
pp. 726-734 ◽  
Author(s):  
Fariborz Majdzadeh ◽  
Sayed Mohamad Soleimani ◽  
Nemkumar Banthia

The purpose of this study was to investigate the influence of fiber reinforcement on the shear capacity of reinforced concrete (RC) beams. Both steel and synthetic fibers at variable volume fractions were investigated. Two series of tests were performed: structural tests, where RC beams were tested to failure under an applied four-point load; and materials tests, where companion fiber-reinforced concrete (FRC) prisms were tested under direct shear to obtain material properties such as shear strength and shear toughness. FRC test results indicated an almost linear increase in the shear strength of concrete with an increase in the fiber volume fraction. Fiber reinforcement enhanced the shear load capacity and shear deformation capacity of RC beams, but 1% fiber volume fraction was seen as optimal; no benefits were noted when the fiber volume fraction was increased beyond 1%. Finally, an equation is proposed to predict the shear capacity of RC beams.Key words: shear strength, fiber-reinforced concrete, RC beam, stirrups, energy absorption capacity, steel fiber, synthetic fiber.


Author(s):  
Edmilson Lira Madureira ◽  
Brenda Vieira Costa Fontes

abstract: The creep of concrete promotes strains over time in structural members kept under sustained load. It causes the stress decrease on the concrete and the steel stress increase in reinforced concrete members. The moisture content and temperature influence significantly such phenomenon. The creep strains model of the NBR 6118/2014 [1] is, applicable, solely, to those cases of constant stress magnitudes. Reinforced concrete members exhibit variations on the stress magnitudes and, in this way, requires the use of an alternative model for the prediction of the creep strains as the so known the State Model. This report refers itself to temperature influence analysis upon creep strains of reinforced concrete structural members. The results have revealed that temperature speeds up the creep effects and, in this way, the steel yielding caused by the stress increase on the reinforcement bars occurs at earlier ages.


2015 ◽  
Vol 2 (1) ◽  
Author(s):  
N. Aravind ◽  
Amiya K. Samanta ◽  
Dilip Kr. Singha Roy ◽  
Joseph V. Thanikal

AbstractStrengthening the structural members of old buildings using advanced materials is a contemporary research in the field of repairs and rehabilitation. Many researchers used plain Glass Fiber Reinforced Polymer (GFRP) sheets for strengthening Reinforced Concrete (RC) beams. In this research work, rectangular corrugated GFRP laminates were used for strengthening RC beams to achieve higher flexural strength and load carrying capacity. Type and dimensions of corrugated profile were selected based on preliminary study using ANSYS software. A total of twenty one beams were tested to study the load carrying capacity of control specimens and beams strengthened with plain sheets and corrugated laminates using epoxy resin. This paper presents the experimental and theoretical study on flexural strengthening of Reinforced Concrete (RC) beams using corrugated GFRP laminates and the results are compared. Mathematical models were developed based on the experimental data and then the models were validated.


Sign in / Sign up

Export Citation Format

Share Document