Performance evaluation of an Indoxyl Sulfate Assay Kit “NIPRO”

2019 ◽  
Vol 57 (11) ◽  
pp. 1770-1776 ◽  
Author(s):  
Yuki Fushimi ◽  
Junko Tatebe ◽  
Yuko Okuda ◽  
Toshiaki Ishii ◽  
Shinji Ujiie ◽  
...  

Abstract Background The relationship between renal disease and cardiovascular disease (CVD) is currently known as cardiorenal syndrome. Indoxyl sulfate (IS) is one of the uremic toxins that accelerates the progression of cardiorenal syndrome. This report presents a new method for measuring IS in a simpler way. Methods We evaluated the analytical performance of an IS Assay Kit “NIPRO” loaded on LABOSPECT 008. The evaluated analytical performances included accuracy, precision, dilution linearity, limit of detection (LOD), limit of quantitation (LOQ), recovery test, interference test and comparison against assays performed by high-performance liquid chromatography (HPLC). Results Total precision showed a <5.3% coefficient of variation at IS concentrations of 3.57–277.73 μmol/L, and satisfactory results were observed in the dilution linearity, LOD, LOQ, recovery and interference tests. The IS Assay Kit “NIPRO” showed a high correlation with the HPLC conventional method (r = 0.993). Conclusions The IS Assay Kit “NIPRO” demonstrated satisfactory analytical performance, and this suggests it could shortly become another common method to measure circulating IS.

2019 ◽  
Vol 15 (3) ◽  
pp. 273-279
Author(s):  
Shweta G. Rangari ◽  
Nishikant A. Raut ◽  
Pradip W. Dhore

Background:The unstable and/or toxic degradation products may form due to degradation of drug which results into loss of therapeutic activity and lead to life threatening condition. Hence, it is important to establish the stability characteristics of drug in various conditions such as in temperature, light, oxidising agent and susceptibility across a wide range of pH values.Introduction:The aim of the proposed study was to develop simple, sensitive and economic stability indicating high performance thin layer chromatography (HPTLC) method for the quantification of Amoxapine in the presence of degradation products.Methods:Amoxapine and its degraded products were separated on precoated silica gel 60F254 TLC plates by using mobile phase comprising of methanol: toluene: ammonium acetate (6:3:1, v/v/v). The densitometric evaluation was carried out at 320 nm in reflectance/absorbance mode. The degradation products obtained as per ICH guidelines under acidic, basic and oxidative conditions have different Rf values 0.12, 0.26 and 0.6 indicating good resolution from each other and pure drug with Rf: 0.47. Amoxapine was found to be stable under neutral, thermal and photo conditions.Results:The method was validated as per ICH Q2 (R1) guidelines in terms of accuracy, precision, ruggedness, robustness and linearity. A good linear relationship between concentration and response (peak area and peak height) over the range of 80 ng/spot to 720 ng/spot was observed from regression analysis data showing correlation coefficient 0.991 and 0.994 for area and height, respectively. The limit of detection (LOD) and limit of quantitation (LOQ) for area were found to be 1.176 ng/mL and 3.565 ng/mL, whereas for height, 50.063 ng/mL and 151.707 ng/mL respectively.Conclusion:The statistical analysis confirmed the accuracy, precision and selectivity of the proposed method which can be effectively used for the analysis of amoxapine in the presence of degradation products.


Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


Author(s):  
Dilshad Ahmad ◽  
Faisal A. Al Meshaiti ◽  
Yazeed K. Al Anazi ◽  
Osama Al Owassil ◽  
Alaa Eldeen B. Yassin

Anastrozole, an aromatase inhibitor drug, is used for the treatment of breast cancer in pre- and postmenopausal women. Anastrozole’s incorporation into nanoparticulate carriers would enhance its therapeutic performance. To perceive the exact loaded amount of drug in nanocarriers, a valid analytical method is required. The reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated by using the C18 column, 150 × 4.6 mm, 5 µm particle size, in isocratic mobile phase composed of 50:50 V/V (volume/volume) acetonitrile–phosphate buffer (pH 3) flowing at a rate of 1.0 mL/min, and a diode array detector (DAD) set at λmax = 215 nm. The validation parameters such as linearity, accuracy, specificity, precision, and robustness have proven the accuracy of the method, with the relative standard deviation percentage (% RSD) values < 2. The limit of detection of the method was found equal to 0.0150 µg/mL, and the limit of quantitation was 0.0607 µg/mL. The percent recovery of sample was in the range of 98.04–99.25%. The method has the advantage of being rapid with a drug retention time of 2.767 min, specific in terms of resolution of peaks void of interference with any of the excipients, and high reproducibility. This makes it highly applicable for quality control purposes.


2017 ◽  
Vol 9 (2) ◽  
pp. 34
Author(s):  
N. Balaji ◽  
Sayeeda Sultana

Objective: An efficient, high performance liquid chromatographic method has been developed and validated for the quantification of related substances in pioglitazone hydrochloride drug substance.Methods: This method includes the determination of three related substances in pioglitazone hydrochloride. The mobile phase A is 0.1% w/v triethylamine in water with pH 2.5 adjusted by dilute phosphoric acid. The mobile phase B is premixed and degassed mixtures of acetonitrile and methanol. The flow rate was 1 ml/min. The elution used was gradient mode. The HPLC column used for the analysis was symmetry C18 with a length of 250 mm, the internal diameter of 4.6 mm and particle size of 5.0 microns.Results: The developed method was found to be linear with the range of 0.006-250% with a coefficient of correlation 0.99. The precision study revealed that the percentage relative standard deviation was within the acceptable limit. The limit of detection and limit of quantitation of the impurities was less than 0.002%and 0.006% with respect to pioglitazone hydrochloride test concentration of 2000 µg/ml respectively. This method has been validated as per ICH guidelines Q2 (R1).Conclusion: A reliable, economical HPLC method was magnificently established for quantitative analysis of related substances of pioglitazone hydrochloride drug substance.


Author(s):  
Sagar B. Wankhede ◽  
Deepak S. Khobragade ◽  
Sukeshini B. Lote ◽  
S. Patil

A combined dose tablet formulation containing Amlodipine besylate and Lisinopril is used for the treatment of essential hypertension. The present study reports development and validation of stability indicating high performance thin layer chromatographic method for simultaneous estimation of these drugs in combined dose tablet formulation. The two drugs were satisfactorily resolved on aluminum plates precoated with silica gel 60F254 using n-butanol : methanol: ammonia (4:4:1 v/v/v) as mobile phase. The Rf value for lisinopril and amlodipine besylate were 0.27±0.02 and 0.62±0.02, respectively. Densitometric evaluation of the separated bands was performed at 215nm. The calibration curves for lisinopril and amlodipine besylate were found to be linear in the concentration range of 1000-6000ng/band. The method was validated as per ICH guidelines for accuracy, precision, robustness, specificity, limit of detection and limit of quantitation. Statistical analysis proves that the method is suitable for simultaneous analysis of Lisinopril and Amlodipine besylate in pharmaceutical formulation without any interference from the excipients/degradant. The developed method offers several advantages such as sensitive, rapid, cost effective and less time consuming as compared to the reported methods. As the method could effectively separate the drugs from its degradation products, it can be employed as a stability indicating method.


2007 ◽  
Vol 90 (3) ◽  
pp. 720-724
Author(s):  
Sevgi Tatar Ulu

Abstract A sensitive and selective high-performance liquid chromatographic method has been developed for the determination of tianeptine (Tia) in tablets. The method is based on derivatization of Tia with 4-chloro-7-nitrobenzofurazan (NBD-Cl). A mobile phase consisting of acetonitrile10 mM orthophosphoric acid (pH 2.5; 77 + 23) was used at a flow rate of 1 mL/min on a C18 column. The Tia-NBD derivative was monitored using a fluorescence detector, with emission set at 520 nm and excitation at 458 nm. Gabapentin was selected as an internal standard. Linear calibration graphs were obtained in the concentration range of 45300 ng/mL. The lower limit of detection (LOD) was 10 ng/mL at a signal-to-noise ratio of 4. The lower limit of quantitation (LOQ) was 45 ng/mL. The relative standard values for intra- and interday precision were &lt;0.46 and &lt;0.57%, respectively. The recovery of the drug samples ranged between 98.89 and 99.85%. No chromatographic interference from the tablet excipients was found. The proposed method was validated in terms of precision, robustness, recovery, LOD, and LOQ. All the validation parameters were within the acceptance range. The proposed method was applied for the determination of Tia in commercially available tablets. The results were compared with those obtained by an ultraviolet spectrophotometric method using t- and F-tests.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Nayan G. Patel ◽  
Kalpana G. Patel ◽  
Kirti V. Patel ◽  
Tejal R. Gandhi

A simple, rapid, and precise high-performance thin-layer chromatographic method was developed for quantitative estimation of luteolin and apigenin inPremna mucronataRoxb., family Verbenaceae. Separation was performed on silica gel 60 F254HPTLC plates using toluene : ethyl acetate : formic acid (6 : 4 : 0.3) as mobile phase for elution of markers from extract. The determination was carried out in fluorescence mode using densitometric absorbance-reflection mode at 366 nm for both luteolin and apigenin. The methanolic extract ofPremna mucronatawas found to contain 10.2 mg/g % luteolin and 0.165 mg/g % of apigenin. The method was validated in terms of linearity, LOD and LOQ, accuracy, precision, and specificity. The calibration curve was found to be linear between 200 and 1000 ng/band for luteolin and 50 and 250 ng/band for apigenin. For luteolin and apigenin, the limit of detection was found to be 42.6 ng/band and 7.97 ng/band while the limit of quantitation was found to be 129.08 ng/band and 24.155 ng/band, respectively. This developed validated method is capable of quantifying and resolving luteolin and apigenin and can be applicable for routine analysis of extract and plant as a whole.


Author(s):  
BAITHA PALANGGATAN MAGGADANI ◽  
JIHAN YASMINA ◽  
HARMITA HARMITA

Objective: Whitening cream is a cosmetic that contains ingredients that can alleviate hyperpigmentation. Tranexamic acid (TA) is one of the potentialanti-pigmentation agents that work through inhibiting plasmin. TA is used in cosmetic formulations at a concentration of 2.5% as a whitening andmoisturizing agent. To date, research on TA in both cosmetics and other pharmaceutical products using high-performance liquid chromatography(HPLC) has not been done directly (without derivatization). Therefore, this study aimed to develop a simple and rapid analytical method for TA(without derivatization) in cosmetic cream samples using reverse-phase HPLC and water as a solvent.Methods: Optimization was conducted by evaluating several parameters that affect sample extraction, as well as composition and mobile phasetypes. The optimal method must fulfill suitability and validation requirements. The optimal method should be able to detect and quantify TA in creamsamples without derivatization.Results: The optimal analysis condition used a ultraviolet detector at a wavelength of 210 nm, acetonitrile: double-distilled water: phosphoric acid(64:34:2) as the mobile phase and a flow rate of 0.8 mL/min. The retention time of the analyte occurred in the 2nd min.Conclusion: The analytical method that met the validation requirements was characterized using parameters such as accuracy, precision, linearity,selectivity, limit, of detection, and limit of quantitation. This method is applicable for analyzing TA content in samples with a concentration of 1.02%.


2017 ◽  
Vol 9 (6) ◽  
pp. 34
Author(s):  
Madhavi K. ◽  
Navamani M. ◽  
Prasanthi C.

Objective: To develop a simple, rapid, economic, accurate and precise reverse phase-high performance liquid chromatographic (RP-HPLC) method for the determination of hydrochlorothiazide and candesartan in the pharmaceutical dosage form and to validate as per international conference on harmonization (ICH) guidelines.Methods: The chromatographic separation was performed on Silanol BDS C18 column (250 x 4.6 mm, 5 μm), a mobile phase consisting of water (pH adjusted to 2.8 with orthophosphoric acid): acetonitrile (30:70 % v/v), with a flow rate 1 ml/min and the detection wavelength of 210 nm using photodiode array (PDA) detector.Results: The developed method resulted in elution of hydrochlorothiazide at 2.28 min and candesartan at 4.28 min. The calibration curves were linear (r2=0.999) in the concentration range of 6.25-18.75 μg/ml and 8-24 μg/ml for hydrochlorothiazide and candesartan respectively. The percentage recoveries were found to be 99.78-100.39 for hydrochlorothiazide and 99.87-100.64 for candesartan. The limit of detection (LOD) was found to be 0.410 μg/ml and 0.699 μg/ml for hydrochlorothiazide and candesartan respectively. The limit of quantitation (LOQ) was found to be 1.367 μg/ml and 2.330 μg/ml for hydrochlorothiazide and candesartan respectively.Conclusion: A simple, economic, accurate, precise, linear and rapid RP-HPLC method was developed for simultaneous quantitative estimation of hydrochlorothiazide and candesartan in bulk and pharmaceutical formulation and the method was validated as per ICH guidelines. Hence, the method holds good for the routine analysis of hydrochlorothiazide and candesartan in various pharmaceutical industries as well as in academics.


2019 ◽  
Vol 57 (10) ◽  
pp. 931-938 ◽  
Author(s):  
Mohammad M Kamal ◽  
Sami Nazzal

Abstract Paclitaxel (PTX) and sulforaphane (SFN) are known anticancer molecules. Their activity was found to be potentiated when tested concurrently. Only recently, however, a novel SFN enabled PTX self-microemulsifying formulation (SMEDDS) was developed for their simultaneous delivery. This necessitated the development of an analytical method for the simultaneous detection and quantitation of PTX and SFN. In this study, a simple and sensitive isocratic high performance liquid chromatography-ultraviolet (HPLC-UV) analytical method was developed and validated per International Conference on Harmonization guidelines to satisfy this objective. Its application was demonstrated when quantifying the amount of PTX and SFN released from the SMEDDS in various dissolution media. The separation of the analytes was performed with the aid of a reversed phase C18 column at ambient temperature using a 60:40 mixture of acetonitrile and KH2PO4 buffer (pH 5.0) as the mobile phase. PTX and SFN peaks were detected at 202 nm with high resolution without interference from excipients. This method showed linearity within 2.5–100 μg/mL range with r2 &gt; 0.999. The limit of detection and lower limit of quantitation were 0.1638 and 0.4964 μg/mL for PTX and 0.4419 and 1.3389 μg/mL for SFN, respectively. A total of 98–101% of the injected samples was recovered with RSD of 0.06–0.68% indicating the suitability of the method for the simultaneous detection and quantitation of the molecules in dissolution media.