No Effect of a Ketone Monoester on Markers of Stress and Performance in a Live-Burn Search and Rescue in Firefighters

2022 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Hunter S. Waldman ◽  
Andrea R. Bryant ◽  
Brandon D. Shepherd ◽  
Brendan Egan ◽  
Matthew J. McAllister
Author(s):  
Carolyn A. Duncan ◽  
Nicole Bishop ◽  
Vicki Komisar ◽  
Scott N. MacKinnon ◽  
Jeannette M. Byrne

Objective The purpose of this study was to examine how intensity of wave motions affects the performance of a simulated maritime search and rescue (SAR) task. Background Maritime SAR is a critical maritime occupation; however, the effect of wave motion intensity on worker performance is unknown. Methods Twenty-four participants (12 male, 12 female) performed a simulated search and rescue task on a six-degree-of-freedom motion platform in two conditions that differed in motion intensity (low and high). Task performance, electromyography (EMG), and number of compensatory steps taken by the individual were examined. Results As magnitude of simulated motion increased, performance in the SAR task decreased, and was accompanied by increases in lower limb muscle activation and number of steps taken. Conclusions Performance of an SAR task and balance control may be impeded by high-magnitude vessel motions. Application This research has the potential to be used by maritime engineers, occupational health and safety professionals, and ergonomists to improve worker safety and performance for SAR operators.


Author(s):  
Hunter Rogers ◽  
Amro Khasawneh ◽  
Jeffery Bertrand ◽  
Kapil Chalil Madathil

Latency is an important factor when conducting teleoperated missions. This study investigates the effects of latency on a set of dependent variables: performance (measured by time and number of errors), subjective workload, trust, and usability. These measures were tested in a simulated search-and-rescue mission over two levels of two independent variables. One independent variable was the number of robots – one or two (within-subject), and the other independent variable was latency – simulations with and without latency (between-subject.) The significant effect of the independent variables on the dependent variables were checked using repeated measure two-way ANOVA with a confidence level of 95%. The data determined any significant effects that latency and/or the number of robots had on such factors as errors, dependability, reliability, harmful outcomes, temporal demand, and frustration.


2018 ◽  
Vol 1 (1) ◽  
pp. 66-71
Author(s):  
Kamran Ahmed Shahani ◽  
Song Hong ◽  
Chaopeng WU ◽  
Syed Raza Mehdi ◽  
Kazim Raza ◽  
...  

This paper focuses on the design and control of unmanned ground vehicle for search and rescue missions which is controlled remotely. This robot is able to move on a variety of surfaces, also having capability of Picking and Placing of various objects and overcome the dangerous areas. The unmanned system is controlled wirelessly using Xbee wireless communication technology. A camera is attached on this mobile robot for live feedback purpose.  Many experiments are conducted to test the potential and performance of the robot.


Author(s):  
Michael Lewis ◽  
Jijun Wang

Conventional models of multirobot control assume independent robots and tasks. This allows an additive model in which the operator controls robots sequentially neglecting each until its performance deteriorates sufficiently to require new operator input. This paper presents a measure of coordination demand, CD, and experiments intended to extend the neglect tolerance model to situations in which robots must cooperate to perform dependent tasks. In the first experiment operators controlled 2 robot teams to perform a box pushing task under high coordination demand, teleoperation, moderate demand (waypoint control/heterogeneous robots), and low demand (waypoint control/homogeneous robots) conditions. In the second experiment participants performed a search and rescue task requiring cooperation between robots creating maps and others carrying cameras. Measured demand and performance were largely consistent with the CD model's predictions.


Author(s):  
H. M. Thieringer

It has repeatedly been show that with conventional electron microscopes very fine electron probes can be produced, therefore allowing various micro-techniques such as micro recording, X-ray microanalysis and convergent beam diffraction. In this paper the function and performance of an SIEMENS ELMISKOP 101 used as a scanning transmission microscope (STEM) is described. This mode of operation has some advantages over the conventional transmission microscopy (CTEM) especially for the observation of thick specimen, in spite of somewhat longer image recording times.Fig.1 shows schematically the ray path and the additional electronics of an ELMISKOP 101 working as a STEM. With a point-cathode, and using condensor I and the objective lens as a demagnifying system, an electron probe with a half-width ob about 25 Å and a typical current of 5.10-11 amp at 100 kV can be obtained in the back focal plane of the objective lens.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
D. E. Newbury ◽  
R. D. Leapman

Trace constituents, which can be very loosely defined as those present at concentration levels below 1 percent, often exert influence on structure, properties, and performance far greater than what might be estimated from their proportion alone. Defining the role of trace constituents in the microstructure, or indeed even determining their location, makes great demands on the available array of microanalytical tools. These demands become increasingly more challenging as the dimensions of the volume element to be probed become smaller. For example, a cubic volume element of silicon with an edge dimension of 1 micrometer contains approximately 5×1010 atoms. High performance secondary ion mass spectrometry (SIMS) can be used to measure trace constituents to levels of hundreds of parts per billion from such a volume element (e. g., detection of at least 100 atoms to give 10% reproducibility with an overall detection efficiency of 1%, considering ionization, transmission, and counting).


Sign in / Sign up

Export Citation Format

Share Document