Analyse des Übertragungsverhaltens von Differenzdrucksensoren durch dynamische DruckkalibrierungAnalyzing Frequency Response of Differential Pressure Sensors by Dynamic Pressure Calibration

2010 ◽  
Vol 77 (2) ◽  
Author(s):  
Timo Kober ◽  
Stefan Sindlinger ◽  
Roland Werthschützky
2010 ◽  
Vol 437 ◽  
pp. 8-12 ◽  
Author(s):  
Sheng Hung Wang ◽  
Lee Long Han ◽  
Tsing Tshih Tsung

. This study presents the dynamic calibration of pressure sensors using a developed liquid step wave generator. This approach is sufficient to display the transient response of pressure sensors in the time and frequency domains and it depends on the performance of pressure generators. In this study, the liquid step wave generator was developed via a reformed spool valve generating a liquid step wave with a short rise time that current generators have not achieved so far. A small sensing cavity, where maintains the liquid step wave, and a contact seal were adopted herein to limit the pressure transient of the fluid in the generator, such that the rise time and the bandwidth of the liquid step wave can reach 30.0 µs and 10.4 kHz. The experimental results not only display the performance of the liquid step wave generator, but also reveal the dynamic characteristics of three different test pressure sensors using the developed liquid step wave generator.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1609
Author(s):  
Donghyun Hwang ◽  
Kyubok Ahn

An experimental study was performed to investigate the combustion instability characteristics of swirl-stabilized combustors. A premixed gas composed of ethylene and air was burned under various flow and geometric conditions. Experiments were conducted by changing the inlet mean velocity, equivalence ratio, swirler vane angle, and combustor length. Two dynamic pressure sensors, a hot-wire anemometer, and a photomultiplier tube were installed to detect the pressure oscillations, velocity perturbations, and heat release fluctuations in the inlet and combustion chambers, respectively. An ICCD camera was used to capture the time-averaged flame structure. The objective was to understand the relationship between combustion instability and the Rayleigh criterion/the flame structure. When combustion instability occurred, the pressure oscillations were in-phase with the heat release oscillations. Even if the Rayleigh criterion between the pressure and heat release oscillations was satisfied, stable combustion with low pressure fluctuations was possible. This was explained by analyzing the dynamic flow and combustion data. The root-mean-square value of the heat release fluctuations was observed to predict the combustion instability region better than that of the inlet velocity fluctuations. The bifurcation of the flame structure was a necessary condition for combustion instability in this combustor. The results shed new insight into combustion instability in swirl-stabilized combustors.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7493
Author(s):  
Krystian L. Wlodarczyk ◽  
William N. MacPherson ◽  
Duncan P. Hand ◽  
M. Mercedes Maroto-Valer

In situ measurements are highly desirable in many microfluidic applications because they enable real-time, local monitoring of physical and chemical parameters, providing valuable insight into microscopic events and processes that occur in microfluidic devices. Unfortunately, the manufacturing of microfluidic devices with integrated sensors can be time-consuming, expensive, and “know-how” demanding. In this article, we describe an easy-to-implement method developed to integrate various “off-the-shelf” fiber optic sensors within microfluidic devices. To demonstrate this, we used commercial pH and pressure sensors (“pH SensorPlugs” and “FOP-MIV”, respectively), which were “reversibly” attached to a glass microfluidic device using custom 3D-printed connectors. The microfluidic device, which serves here as a demonstrator, incorporates a uniform porous structure and was manufactured using a picosecond pulsed laser. The sensors were attached to the inlet and outlet channels of the microfluidic pattern to perform simple experiments, the aim of which was to evaluate the performance of both the connectors and the sensors in a practical microfluidic environment. The bespoke connectors ensured robust and watertight connection, allowing the sensors to be safely disconnected if necessary, without damaging the microfluidic device. The pH SensorPlugs were tested with a pH 7.01 buffer solution. They measured the correct pH values with an accuracy of ±0.05 pH once sufficient contact between the injected fluid and the measuring element (optode) was established. In turn, the FOP-MIV sensors were used to measure local pressure in the inlet and outlet channels during injection and the steady flow of deionized water at different rates. These sensors were calibrated up to 140 mbar and provided pressure measurements with an uncertainty that was less than ±1.5 mbar. Readouts at a rate of 4 Hz allowed us to observe dynamic pressure changes in the device during the displacement of air by water. In the case of steady flow of water, the pressure difference between the two measuring points increased linearly with increasing flow rate, complying with Darcy’s law for incompressible fluids. These data can be used to determine the permeability of the porous structure within the device.


2004 ◽  
Vol 10 (6) ◽  
pp. 433-442 ◽  
Author(s):  
Giovanni Ferrara ◽  
Lorenzo Ferrari ◽  
Leonardo Baldassarre

The rotating stall is a key problem for achieving a good working range of a centrifugal compressor and a detailed understanding of the phenomenon is very important to anticipate and avoid it. Many experimental tests have been planned by the authors to investigate the influence on stall behavior of different geometrical configurations. A stage with a backward channel upstream, a 2-D impeller with a vaneless diffuser and a constant cross-section volute downstream, constitute the basic configuration. Several diffuser types with different widths, pinch shapes, and diffusion ratios were tested. The stage was instrumented with many fast response dynamic pressure sensors so as to characterize inception and evolution of the rotating stall. This kind of analysis was carried out both in time and in frequency domains. The methodology used and the results on phenomenon evolution will be presented and discussed in this article.


Author(s):  
Juan Francisco Fuentes-Perez ◽  
Christian Meurer ◽  
Jeffrey Andrew Tuhtan ◽  
Maarja Kruusmaa

Machines ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 326
Author(s):  
Huiyan Zhang ◽  
Fan Meng ◽  
Yunhao Zheng ◽  
Yanjun Li

To reduce cavitation-induced pressure fluctuations in a mixed-flow pump under impeller inflow distortion, the dynamic pressure signal at different monitoring points of a mixed-flow pump with a dustpan-shaped inlet conduit under normal and critical cavitation conditions was collected using high-precision digital pressure sensors. Firstly, the nonuniformity of the impeller inflow caused by inlet conduit shape was characterized by the time–frequency-domain spectra and statistical characteristics of pressure fluctuation at four monitoring points (P4–P7) circumferentially distributed at the outlet of the inlet conduit. Then, the cavity distribution on the blade surface was captured by a stroboscope. Lastly, the characteristics of cavitation-induced pressure fluctuation were obtained by analyzing the time–frequency-domain spectra and statistical characteristic values of dynamic pressure signals at the impeller inlet (P1), guide vanes inlet (P2), and guide vanes outlet (P3). The results show that the flow distribution of impeller inflow is asymmetric. The pav values at P4 and P6 were the smallest and largest, respectively. Compared with normal conditions, the impeller inlet pressure is lower under critical cavitation conditions, which leads to low pav, pp-p and a main frequency amplitude at P1. In addition, the cavity covered the whole suction side under H = 13.6 m and 15.5 m, which led the pp-p and dominant frequency amplitude of pressure fluctuation at P2 and P3 under critical cavitation to be higher than that under normal conditions.


Author(s):  
Christian Lehr ◽  
Andreas Linkamp ◽  
Daniel Aurich ◽  
Andreas Brümmer

Subject of discussion are simulations and experimental investigations on the acoustic characterization of three single stage centrifugal pumps of different specific speed. In operation, these pump-types generate pressure pulsation at blade passing frequency, primarily due to rotor-volute-interaction. In order to determine the acoustic excitation it is necessary to know about the pumps’ acoustic transmission parameters. In this paper, a one-dimensional numerical model for transient time-domain simulation is presented, which takes into account the pump geometry as well as the volutes’ structural behaviour by means of the local effective speed of sound. Numerical results for the transmission characteristics of the three different pumps are shown in terms of scattering matrices and evaluated against parameters calculated from measurement results. The experimental analyses are carried out using dynamic pressure sensors in both the suction and the discharge pipe. Assuming solely plane wave propagation, the complex acoustic field on each side is evaluated independently. The so called “two source” method is then used to determine the transmission parameters of the pumps in standstill for a range of frequencies experimentally. Subsequently, the acoustic excitation at varying rotational speed is evaluated by means of measurements at the pumps in operation and presented as monopole and dipole source types for cavitation-free conditions.


Author(s):  
M. S. Riaz ◽  
K. J. Barb ◽  
A Engeda

In this paper, a novel approach is presented to increase the operational flexibility of steam turbines. Exhaust pressure at the exit of the last-stage blades is one of the most important parameters that limit the operation of a steam turbine, especially on days with hot ambient conditions. The main concern in these off-design high-exhaust pressure operating conditions is that it can result in flow separation, which can lead to aeromechanics instabilities and thus to blade failure because of high-cycle fatigue. In the method proposed in this paper, dynamic pressure transducers are placed around the perimeter of the last-stage blade to measure the pressure variations caused by vibrating last-stage blades. This approach, which is applicable to condensing turbines only, will provide increased exhaust pressure limits through realtime monitoring of the pressure signal and thereby enable the power plant to produce more power during times of peak demand. Finite elements analysis was performed to predict the natural frequencies of the row of blades to distinguish between the synchronous and nonsynchronous modes of vibration. Strain gauges were placed on the blades to obtain the experimental frequency information of the system. Response from the dynamic pressure transducers was compared with responses from the strain gauges. An excellent agreement between the two sets of results proved the validity of the proposed method.


Sign in / Sign up

Export Citation Format

Share Document