scholarly journals EVAPORATIVE WATER AND AIR COOLERS FOR SOLAR COOLING SYSTEMS. ANALYSIS AND PERSPECTIVES

2017 ◽  
Vol 52 (5) ◽  
Author(s):  
A. Doroshenko ◽  
K. Shestopalov ◽  
I. Mladionov

The concept of evaporative coolers of gases and fluids on the basis of monoblock multichannel polymeric structures is presented. Different schemes of indirect evaporative coolers, in which the natural cooling limit is the dew point of the ambient air  are discussed. In such systems the cooling temperature is lower than the wet bulb temperature of the ambient air. Special attention is paid to the recondensation of water vapor for deep evaporative cooling. It is shown that for the solution of the recondensation problem it is necessary to vary the ratio of the contacting air and water flows, particularly in each stage of the multistage system. Recommendations for the deep cooling process implementation in the evaporative coolers of gases and liquids are given.

2021 ◽  
Vol 13 (5) ◽  
pp. 2836
Author(s):  
Khawar Shahzad ◽  
Muhammad Sultan ◽  
Muhammad Bilal ◽  
Hadeed Ashraf ◽  
Muhammad Farooq ◽  
...  

Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is explored. This is so because the broilers lack sweat glands as compared to humans and undergo panting process to mitigate their latent heat (moisture produced in the body) in the air. As a result, moisture production inside poultry house needs to be maintained to avoid any serious health and welfare complications. Several strategies such as compressor-based air-conditioning systems have been implemented worldwide to attenuate the heat stress in poultry, but these are not economical. Therefore, this study focuses on the development of low-cost and environmentally friendly improved evaporative cooling systems (DEC, IEC, MEC) from the viewpoint of heat stress in poultry houses. Thermodynamic analysis of these systems was carried out for the climatic conditions of Multan, Pakistan. The results appreciably controlled the environmental conditions which showed that for the months of April, May, and June, the decrease in temperature by direct evaporative cooling (DEC), indirect evaporative cooling (IEC), and Maisotsenko-Cycle evaporative cooling (MEC) systems is 7–10 °C, 5–6.5 °C, and 9.5–12 °C, respectively. In case of July, August, and September, the decrease in temperature by DEC, IEC, and MEC systems is 5.5–7 °C, 3.5–4.5 °C, and 7–7.5 °C, respectively. In addition, drop in temperature-humidity index (THI) values by DEC, IEC, and MEC is 3.5–9 °C, 3–7 °C, and 5.5–10 °C, respectively for all months. Optimum temperature and relative humidity conditions are determined for poultry birds and thereby, systems’ performance is thermodynamically evaluated for poultry farms from the viewpoint of THI, temperature-humidity-velocity index (THVI), and thermal exposure time (ET). From the analysis, it is concluded that MEC system performed relatively better than others due to its ability of dew-point cooling and achieved THI threshold limit with reasonable temperature and humidity indexes.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2574 ◽  
Author(s):  
Ramadas Narayanan ◽  
Edward Halawa ◽  
Sanjeev Jain

Air conditioning accounts for up to 50% of energy use in buildings. Increased air-conditioning-system installations not only increase total energy consumption but also raise peak load demand. Desiccant evaporative cooling systems use low-grade thermal energy, such as solar energy and waste heat, instead of electricity to provide thermal comfort. This system can potentially lead to significant energy saving, reduction in carbon emissions, and it has a low dew-point operation and large capacity range. Their light weight, simplicity of design, and close-to-atmospheric operation make them easy to maintain. This paper evaluates the applicability of this technology to the climatic conditions of Brisbane, Queensland, Australia, specifically for the residential sector. Given the subtropical climate of Brisbane, where humidity levels are not excessively high during cooling periods, the numerical study shows that such a system can be a potential alternative to conventional compression-based air-conditioning systems. Nevertheless, the installation of such a system in Brisbane’s climate zone requires careful design, proper selection of components, and a cheap heat source for regeneration. The paper also discusses the economy-cycle options for this system in such a climate and compares its effectiveness to natural ventilation.


1984 ◽  
Vol 7 (5) ◽  
pp. 327-332 ◽  
Author(s):  
S Ayyash ◽  
R.K Suri ◽  
G.P Maheshwari

1987 ◽  
Vol 253 (6) ◽  
pp. R883-R889 ◽  
Author(s):  
L. P. Folkow ◽  
A. S. Blix

Metabolic rate (MR), expired air temperature (Tex), respiratory frequency (f), respiratory minute volume (V), and skin (Ts) and body (Tb) temperatures were recorded in three gray seals (Halichoerus grypus) at ambient air temperatures (Ta) between -40 and +20 degrees C. At Ta within the thermoneutral zone, MR averaged 3.7 W.kg-0.75, while mean V was 0.26 1.min-1.kg-0.75. At Ta below -11 degrees C [apparent lower critical temperature (Tlc)], both MR and V increased linearly with decreasing Ta. Average maximum MR (9.6 W.kg-0.75) and V (0.57 1.min-1.kg-0.75) were both recorded at Ta of -40 degrees C. Tex decreased with decreasing Ta to an average minimum value of 8 degrees C at Ta of -30 degrees C. The highest Tex recorded was 32 degrees C at Ta of +20 degrees C. At Ta of -20 degrees C, both total respiratory heat loss, with one exception, and respiratory evaporative water loss reached their lowest values. At this Ta, 66% of the heat and 80% of the water added to the inspired air were regained on expiration. We suggest that nasal heat exchange may be of considerable importance for thermal and water balance in many pinnipeds.


Author(s):  
Carlos Naranjo-Mendoza ◽  
Jesús López-Villada ◽  
Gabriel Gaona ◽  
Jerko Labus

This paper presents a comparative analysis of three different solar cooling system configurations developed for a case study building in Guayaquil, Ecuador. Guayaquil is a city located at the Ecuadorian coast with an average annual temperature of 25°C. The city’s need for air conditioning throughout the year and the relatively intense solar radiation provide a great opportunity for implementation of solar cooling systems. The first cooling system includes a 175 kWc single-effect absorption chiller powered by evacuated tubes solar thermal collectors. This system was compared with two 140 kWc compression chiller systems (air-cooled (AC) and water-cooled (WC)) powered by grid-connected photovoltaics. Both constant flow rate (CFR) and variable flow rate (VFR) of chilled water were analyzed. The three systems have to satisfy a cooling demand of the top floor in one governmental building (app. 1296 m2) which was selected as case study. Additionally, two 140 kWc conventional compression chiller systems (AC and WC) were included in the comparison as reference systems. Cooling demand of the building was simulated in EnergyPlus and coupled with the appropriate system configurations developed in TRNSYS. The weather file (TMY) was developed based on real meteorological data collected in the last decade. The present analysis was extended with the prediction scenarios for the years 2020, 2050 and 2080 using climate change adapted weather files.


1993 ◽  
Vol 115 (4) ◽  
pp. 212-219 ◽  
Author(s):  
A. A. Pesaran

We conducted experiments to quantify the effects of thermal cycling and exposure to contamination on solid desiccant materials that may be used in desiccant cooling systems. The source of contamination was cigarette smoke, which is considered one of the worst pollutants in building cooling applications. We exposed five different solid desiccants to “ambient” and “contaminated” humid air: silica gel, activated alumina, activated carbon, molecular sieves, and lithium chloride. We obtained the moisture capacity of samples as a function of exposure time. Compared to virgin desiccant samples, the capacity loss caused by thermal cycling with humid ambient air was 10 percent to 30 percent for all desiccants. The capacity loss because of combined effect of thermal cycling with “smoke-filled” humid air was between 30 percent to 70 percent. The higher losses occurred after four months of experiment time, which is equivalent to four to eight years of field operation. Using a system model and smoke degradation data on silica gel, we predicted that, for low-temperature regeneration, the loss in performance of a ventilation-cycle desiccant cooling system would be between 10 percent to 35 percent, in about eight years, with higher value under worst conditions.


2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Hakan Caliskan ◽  
Dae-Young Lee ◽  
Hiki Hong

Abstract In this paper, the effects of regenerative evaporative coolers on the dry desiccant air cooling system are assessed. Thermodynamic analysis is performed point by point on the unmodified (ɛ = 0.67) and modified (ɛ = 1) regenerative evaporative cooler supported systems. It is found that the effectiveness and efficiency of the system were significantly increased by modification. Effectiveness of the system increases from 0.95 to 2.16 for the wet bulb and from 0.63 to 1.43 for dew point effectivenesses, while the exergy efficiency increases from 18.40% to 41.93%. Exergy and energy performances of the system increase 1.28 times and 0.61 times, respectively. Finally, sustainability is increased by 40% with the modification of the regenerative evaporative cooler. Also, changing the regenerative evaporative cooler of the solid desiccant wheel with the effective one can increase the overall system efficiency and performance without changing the sensible heat and desiccant wheels.