scholarly journals Physicochemical Properties of a Methacrylate-Based Dental Adhesive Incorporated with Epigallocatechin-3-gallate

2014 ◽  
Vol 25 (6) ◽  
pp. 528-531 ◽  
Author(s):  
Jiovanne Rabelo Neri ◽  
Monica Yamauti ◽  
Victor Pinheiro Feitosa ◽  
Amanda Pontes Maia Pires ◽  
Rinaldo dos Santos Araújo ◽  
...  

This study aimed to evaluate the influence of epigallocatechin-3-gallate (EGCG) incorporation on the physicochemical properties of a methacrylate-based dental adhesive. EGCG was added to Adper Easy One (3M-ESPE) except in control group, to obtain concentrations of 0.01% w/w and 0.1% w/w of EGCG-doped adhesives. For water sorption (WS) and solubility (SL) surveys, resin discs were assayed following ISO recommendations (n=10). The degree of conversion (DC) was analyzed by FTIR whereas flexural strength (FS) was tested by three-point bending with bar specimens (n=10). Data were subjected to one-way ANOVA and Tukey's test (p<0.05). No significant difference in the DC, WS and FS were found between the different concentrations of EGCG (p>0.05). Adhesives containing 0.1% or 0.01% of EGCC demonstrated similar values of SL (p>0.05) and higher than those found for adhesive without EGCC (p<0.05). In conclusion, the addition of EGCC to adhesive reduced the solubility without affecting the other evaluated properties.

2021 ◽  
Vol 14 (1) ◽  
pp. 61-67
Author(s):  
Prathibha Nandagiri ◽  
◽  
Mamidi Praveen ◽  
Shikha Singh ◽  
Monika Singh ◽  
...  

Typically, prosthodontists adjust ceramic restorations glazed surface by grinding prior to insertion. Such alterations of surfaces are necessary for the correction of occlusal interferences. We aimed to evaluate and compare the change in flexural strength of ceramic surfaces after re-glazing and polishing. This study included 40 samples of ceramic blocks that were fabricated and glazed, and then fired in accordance with the manufacturer’s recommendations. The sample was randomly divided into four groups of 10 samples each. The first group was the control group with unaltered glazed samples. The second group was abraded with an extra-fine diamond bur followed by re-glazing, and the other two groups were polished with two commercially available polishing kits after abrading them with an extra-fine diamond bur. The samples were tested for their flexural strength using a universal testing machine. On the application of the F test on the means of all the groups, a value greater than 0.05 was found, which meant that there is no statistically significant difference in flexural strength values between the groups (P-value>0.05). Since the flexural strength values of the polished group were comparable to the other groups, polishing can be used instead of re-glazing for ceramic restorations. This reduces an additional clinical appointment for the patient and saves working time.


2020 ◽  
Vol 9 (11) ◽  
pp. e069119401
Author(s):  
Flávia Gonçalves ◽  
Luiza Mello de Paiva Campos ◽  
Luciana Katty Figueiredo Sanches ◽  
Larissa Tavares Sampaio Silva ◽  
Tamiris Martins Ribeiro dos Santos ◽  
...  

Introduction: this study aimed to evaluate the antimicrobial and physicochemical properties of a commercial endodontic sealer modified by the addition of montmorillonite (MMT) nanoparticles loaded with two different drugs: chlorhexidine (CHX) or metronidazole (MET). Methods: 5 wt% MMT/CHX or MMT/MET nanoparticles were added to the sealer AH-Plus. The experimental materials were evaluated for drug release, antimicrobial activity, flow, flexural strength, and flexural modulus. Data were subjected to one-way ANOVA, Kruskal-Wallis, and Mann-Whitney tests. Results: The drug incorporation into MMT particles was 9% and 10% for CHX and MET, respectively. At 20 days after manipulation, 16.5% of the drug was released by the sealer with MMT/MET and 0.4% by MMT/CHX. The addition of both nanoparticles decreased the flow of materials, but they were still in compliance with ISO 6876-2012. The conversion, flexural strength, and flexural modulus of MMT/MET (87%, 37±7 MPa, 2.3 GPa) and MMT/CHX (78%, 29±2 MPa, 2.7 GPa) were similar in both groups but lower than in the control group (100%, 54±7 MPa, 4.0±0.7 GPa). Both experimental materials were able to form an inhibition halo for E. faecalis bacteria (CHX: 4.8±1.4 and MET: 4.0±1.6 mm), whereas the control group did not inhibit the microorganism. Conclusion: both formulations proposed as endodontic sealer presented effective antimicrobial activity and acceptable flow. The addition of MMT/CHX and MMT/MET particles decreased the conversion and mechanical properties, but further studies are required to clarify the clinical relevance of these properties.


2020 ◽  
Vol 31 (5) ◽  
pp. 511-515
Author(s):  
Hernán Coaguila-Llerena ◽  
Victor Manuel Ochoa-Rodriguez ◽  
Gabriela Mariana Castro-Núñez ◽  
Gisele Faria ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
...  

Abstract This study aimed to assess the physicochemical properties of a repair material in the Brazilian market, BioMTA, in comparison to other two materials currently in use (Biodentine and MTA Angelus). The initial setting time was evaluated using Gillmore needle. The pH was measured with a pH-meter after 24 h, 3, 7, 14 and 21 days. The radiopacity was determined using the equivalence in millimeters of aluminum (mm Al) from digitized occlusal radiographs. Solubility was determined after immersion in water for 7 days. The data were analyzed by one-way ANOVA and Tukey tests (a=0.05). The BioMTA initial setting time (5.2 min) was lower than the other materials (p<0.05). All materials showed an alkaline pH at 21 days. At 24 h, BioMTA was the most alkaline material (p<0.05); and at 3, 7, 14 and 21 days there was no difference between BioMTA and Biodentine (p>0.05), both being more alkaline than MTA Angelus (p<0.05). The radiopacity of BioMTA (4.2 mm Al) was significantly higher compared to Biodentine (p<0.05) and lower than MTA Angelus (p<0.05). The solubility of the materials was -4.2%, -1.6% and 4.1% for BioMTA, MTA Angelus and Biodentine, respectively, with a significant difference between them (p<0.05). Therefore, it can be concluded that BioMTA displayed a shorter setting time, an alkaline pH, a higher radiopacity, and a gain in mass.


2012 ◽  
Vol 23 (6) ◽  
pp. 686-691 ◽  
Author(s):  
João Paulo Lyra e Silva ◽  
Alfredo Júlio Fernandes Neto ◽  
Luís Henrique Araújo Raposo ◽  
Veridiana Resende Novais ◽  
Cleudmar Amaral de Araujo ◽  
...  

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.


Polymers ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1745
Author(s):  
Tamaki Hada ◽  
Manabu Kanazawa ◽  
Maiko Iwaki ◽  
Awutsadaporn Katheng ◽  
Shunsuke Minakuchi

In this study, the physical properties of a custom block manufactured using a self-polymerizing resin (Custom-block), the commercially available CAD/CAM PMMA disk (PMMA-disk), and a heat-polymerizing resin (Conventional PMMA) were evaluated via three different tests. The Custom-block was polymerized by pouring the self-polymerizing resin into a special tray, and Conventional PMMA was polymerized with a heat-curing method, according to the manufacturer’s recommended procedure. The specimens of each group were subjected to three-point bending, water sorption and solubility, and staining tests. The results showed that the materials met the requirements of the ISO standards in all tests, except for the staining tests. The highest flexural strength was exhibited by the PMMA-disk, followed by the Custom-block and the Conventional PMMA, and a significant difference was observed in the flexural strengths of all the materials (p < 0.001). The Custom-block showed a significantly higher flexural modulus and water solubility. The water sorption and discoloration of the Custom-block were significantly higher than those of the PMMA-disk, but not significantly different from those of the Conventional PMMA. In conclusion, the mechanical properties of the three materials differed depending on the manufacturing method, which considerably affected their flexural strength, flexural modulus, water sorption and solubility, and discoloration.


2021 ◽  
Vol 10 (12) ◽  
pp. 2637
Author(s):  
Mª. Ángeles del Buey-Sayas ◽  
Elena Lanchares-Sancho ◽  
Pilar Campins-Falcó ◽  
María Dolores Pinazo-Durán ◽  
Cristina Peris-Martínez

Purpose: To evaluate and compare corneal hysteresis (CH), corneal resistance factor (CRF), and central corneal thickness (CCT), measurements were taken between a healthy population (controls), patients diagnosed with glaucoma (DG), and glaucoma suspect patients due to ocular hypertension (OHT), family history of glaucoma (FHG), or glaucoma-like optic discs (GLD). Additionally, Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated IOP (IOPcc) were compared between the different groups of patients. Methods: In this prospective analytical-observational study, a total of 1065 patients (one eye of each) were recruited to undergo Ocular Response Analyzer (ORA) testing, ultrasound pachymetry, and clinical examination. Corneal biomechanical parameters (CH, CRF), CCT, IOPg, and IOPcc were measured in the control group (n = 574) and the other groups: DG (n = 147), FHG (n = 78), GLD (n = 90), and OHT (n = 176). We performed a variance analysis (ANOVA) for all the dependent variables according to the different diagnostic categories with multiple comparisons to identify the differences between the diagnostic categories, deeming p < 0.05 as statistically significant. Results: The mean CH in the DG group (9.69 mmHg) was significantly lower compared to controls (10.75 mmHg; mean difference 1.05, p < 0.001), FHG (10.70 mmHg; mean difference 1.00, p < 0.05), GLD (10.63 mmHg; mean difference 0.93, p < 0.05) and OHT (10.54 mmHg; mean difference 0.84, p < 0.05). No glaucoma suspects (FHG, GLD, OHT groups) presented significant differences between themselves and the control group (p = 1.00). No statistically significant differences were found in the mean CRF between DG (11.18 mmHg) and the control group (10.75 mmHg; mean difference 0.42, p = 0.40). The FHG and OHT groups showed significantly higher mean CRF values (12.32 and 12.41 mmHg, respectively) than the DG group (11.18 mmHg), with mean differences of 1.13 (p < 0.05) and 1.22 (p < 0.001), respectively. No statistically significant differences were found in CCT in the analysis between DG (562 μ) and the other groups (control = 556 μ, FHG = 576 μ, GLD = 569 μ, OHT = 570 μ). The means of IOPg and IOPcc values were higher in the DG patient and suspect groups than in the control group, with statistically significant differences in all groups (p < 0.001). Conclusion: This study presents corneal biomechanical values (CH, CRF), CCT, IOPg, and IOPcc for diagnosed glaucoma patients, three suspected glaucoma groups, and a healthy population, using the ORA. Mean CH values were markedly lower in the DG group (diagnosed with glaucoma damage) compared to the other groups. No significant difference was found in CCT between the DG and control groups. Unexpectedly, CRF showed higher values in all groups than in the control group, but the difference was only statistically significant in the suspect groups (FHG, GLD, and OHT), not in the DG group.


2017 ◽  
Vol 7 (2) ◽  
pp. 67 ◽  
Author(s):  
Mehmet Fatih Ocal

Integrating the properties of computer algebra systems and dynamic geometry environments, Geogebra became an effective and powerful tool for teaching and learning mathematics. One of the reasons that teachers use Geogebra in mathematics classrooms is to make students learn mathematics meaningfully and conceptually. From this perspective, the purpose of this study was to investigate whether instruction with Geogebra has effect on students’ achievements regarding their conceptual and procedural knowledge on the applications of derivative subject. This study adopted the quantitative approach with pre-test post-test control group true experimental design. The participants were composed of two calculus classrooms involving 31 and 24 students, respectively. The experimental group with 31 students received instruction with Geogebra while the control group received traditional instruction in learning the applications of derivative. Independent samples t-test was used in the analysis of the data gathered from students’ responses to Applications of Derivative Test which was subjected to them before and after teaching processes. The findings indicated that instruction with Geogebra had positive effect on students’ scores regarding conceptual knowledge and their overall scores. On the other hand, there was no significant difference between experimental and control group students’ scores regarding procedural knowledge. It could be concluded that students in both groups were focused on procedural knowledge to be successful in learning calculus subjects including applications of derivative in both groups. On the other hand, instruction with Geogebra supported students’ learning these subjects meaningfully and conceptually.


2017 ◽  
Vol 28 (6) ◽  
pp. 726-730 ◽  
Author(s):  
Caio Vinícius Signorelli Grohmann ◽  
Eveline Freitas Soares ◽  
Eduardo José Carvalho Souza-Junior ◽  
William Cunha Brandt ◽  
Regina Maria Puppin-Rontani ◽  
...  

Abstract The aim in this study was to evaluate the influence of different ratio of camphorquinone/tertiary amine concentration on the flexural strength (FS), elastic modulus (EM), degree of conversion (DC), yellowing (YL), water sorption (WS) and water solubility (WSL) of experimental composites. Thus, acrylate blends were prepared with different camphorquinone (CQ) and amine (DABE) concentrations and ratios by weight: (CQ/DABE%): 0.4/0.4% (C1), 0.4/0.8% (C2), 0.6/0.6% (C3), 0.6/1.2% (C4), 0.8/0.8% (C5), 0.8/1.6% (C6), 1.0/1.0% (C7), 1.0/2.0% (C8), 1.5/1.5% (C9), 1.5/3.0% (C10). For the FS and EM, rectangular specimens (7x2x1 mm, n=10) were photo-activated by single-peak LED for 20 s and tested at Instron (0.5 mm/min). Then, the same specimens were evaluated by FTIR for DC measurement. For YL, disks (5x2 mm, n=10) were prepared, light-cured for 20 s and evaluated in spectrophotometer using the b aspect of the CIEL*a*b* system. For WS and WSL, the volume of the samples was calculated (mm³). For WS and WSL, composites disks (5x0.5 mm, n=5) were prepared. After desiccation, the specimens were stored in distilled water for 7 days and again desiccated, in order to measure the WS and WSL. Data were submitted to one-way ANOVA and Tukey’s test (5%). The groups C8, C9 and C10 showed higher DC, EM and YL means, compared to other composites. Therefore, the FS and WS values were similar among all groups. Also, C1, C2 and C3 presented higher WSL in 7 days, compared to other composites. In general, higher concentrations of camphorquinone promoted higher physical-mechanical properties; however, inducing higher yellowing effect for the experimental composites


Author(s):  
Rida Ali Alsous

The aim of the study was to clear-out the effect of the round house strategy on the achievement of physical concepts at the ninth grade. The study consisted of (48) students at the Jufa Secondary School for girls for the second semester 2018/2019, distributed randomly to two divisions in the same school, one of which was experimental and the other experimental. This study found that there was a statistically significant difference in the post-test in the students' acquisition of physical concepts at (α = 0.05) between the average performance of the experimental group studied using the circular house strategy and obtained an average of (19.70), and the control group studied in the usual way and obtained Average (14.63), in favor of the experimental group. In light of these results, the researcher recommended using the circular house strategy because of its importance in gaining physical concepts among students. In light of these results, the researcher recommended using the round house strategy and its role in acquiring physical concepts in demand


2018 ◽  
Vol 6 (10) ◽  
pp. 183
Author(s):  
Serhat Üstündağ ◽  
Gülsen Özcan

This research examines the effect of educational games on self-concept levels of inclusive students enrolled in secondary schools. The research was conducted in two secondary schools in Golbasi district of Ankara, the capital of Turkey, in the spring semester of 2015 - 2016 academic year. The research employed semi-experimental design with pretest and posttest control group. Of a total of 24 students, 12 (4 girls, 8 boys) were included in the experimental group and the other 12 (6 girls, 6 boys) were included in the control group. Educational games program, an independent variable of the research, was applied for 11 weeks, 2 lessons per week. The program that did not include educational games was applied to the control group. Self-concept Scale (SCS) was used to collect data in the research. Independent group t test was used for data analysis, and for single-factor repeated measures, two-factor ANOVA test was used. The significance level was determined to be 0.05. At the end of this research, a significant difference was found in favor of the students in the experimental group in terms of physical competence, physical appearance, peer relationships and general self-concept dimensions of the self-concept scale. On the other hand, there was not any significant difference in favor of both groups in terms of the dimension of relations with parents of the scale.


Sign in / Sign up

Export Citation Format

Share Document