scholarly journals New Perspective for Heat Transfer Evaluation During Film Condensation Inside Tubes

2021 ◽  
Vol 39 (2) ◽  
pp. 390-402
Author(s):  
Yanán Camaraza-Medina

This paper presents the main results of the research developed by the author in his postdoctoral investigations on heat transfer calculations during film condensation inside tubes. The elements studied are combined in an analysis expression that provides a reasonable fit with the available experimental data, which includes a total of 22 fluids, including water, refrigerants and a wide range of organic substances, which condense inside horizontal, inclined and vertical tubes. These experimental data were obtained from the reports of 33 sources. Available data covers tube diameters from 2 to 50 mm, mass flow rates from 3 to 850 kg/(m2s), reduced pressures ranging from 0.0008 to 0.91, values for single-phase from 1 to , Reynolds number for two-phase from 900 to 594390, Reynolds number for single-phase from 65 to 84950 and vapor quality from 0.01 to 0.99. The mean deviation found for the analyzed data for horizontal tubes was 13.4%, while for the inclined and vertical tubes data the mean deviation was 14.9%. In all cases, the agreement of the proposed model is good enough to be considered satisfactory for practical design.

1969 ◽  
Vol 91 (3) ◽  
pp. 413-420 ◽  
Author(s):  
H. R. Kunz ◽  
S. Yerazunis

Annular two-phase flow inside of circular tubes is analyzed for a wide range of film Reynolds and Prandtl numbers. This analysis is applied to the prediction of film heat transfer coefficients and film thicknesses for the cases of condensation and evaporation of pure substances inside tubes, two-component flow in tubes, and condensing falling films on vertical surfaces. The analysis is also extended to single-phase flow in tubes. Extensive comparisons are made with experimental and theoretical results of other investigators, indicating good agreement if consideration is given to liquid-vapor interfacial resistance to heat flow for cases involving phase transformation.


2005 ◽  
Vol 127 (4) ◽  
pp. 479-486
Author(s):  
Bin Liu ◽  
Mauricio Prado

For any pumping artificial lift system in the petroleum industry, the free gas significantly affects the performance of the pump and the system above the pump. A model, though not a complete two-phase flow model, has been developed for the effective prediction of separation efficiency across a wide range of production conditions. The model presented is divided into two main parts, the single-phase flow-field solution and the bubble-tracking method. The first part of the model solves the single-phase liquid flow field using the computational fluid dynamics approach. Then, a simple bubble-tracking method was applied to estimate the down-hole natural separation efficiency for two-phase flow. A comparison between the results of the model and the experimental data was conducted. It shows a very good agreement with the experimental data for lower gas void fractions (bubble flow regime).


Author(s):  
Christian Weinmu¨ller ◽  
Dimos Poulikakos

Microfluidics has experienced a significant increase in research activities in recent years with a wide range of applications emerging, such as micro heat exchangers, energy conversion devices, microreactors, lab-on-chip devices and micro total chemical analysis systems (μTAS). Efforts to enhance or extend the performance of single phase microfluidic devices are met by two-phase flow systems [1, 2]. Essential for the design and control of microfluidic systems is the understanding of the fluid/hydrodynamic behavior, especially pressure drop correlations. These are well established for single phase flow, however, analytical correlations for two-phase flow only reflect experimentally obtained values within an accuracy of ± 50% [3, 4]. The present study illustrates the effect of two-phase flow regimes on the pressure drop. Experimental measurement data is put into relation of calculated values based on established correlations of Lockhart-Martinelli with Chisholm modifications for macroscopic flows [5, 6] and Mishima-Hibiki modifications for microscale flows [7]. Further, the experimental pressure drop data is superimposed onto two-phase flow maps to identify apparent correlations of pressure drop abnormalities and flow regimes. The experiments were conducted in a square microchannel with a width of 200 μm. Optical access is guaranteed by an anodically bonded glass plate on a MEMS fabricated silicon chip. Superficial velocities range from 0.01 m/s to 1 m/s for the gas flow and from 0.0001 m/s to 1 m/s for the liquid flow with water as liquid feed and CO2 as gas. The analysis of the flow regimes was performed by imaging the distinct flow regimes by laser induced fluorescence microscopy, employing Rhodamine B as the photosensitive dye. The pressure drop was synchronically recorded with a 200 mbar, 2.5 bar and 25 bar differential pressure transmitter and the data was exported via a LabView based software environment, see Figure 1. Figure 2 illustrates the experimentally obtained pressure drop in comparison to the calculated values based on the Lockhard-Martinelli correlation with the Chisholm modification and the Mishima-Hibiki modification. For both cases the predications underestimate the two-phase pressure drop by more than 50%. Nevertheless, the regression of the experimental data has an offset of linear nature. Two-phase flow is assigned to flow regime maps of bubbly, wedging, slug or annular flow defined by superficial gas and liquid velocities. In Figure 3 the pressure drop is plotted as a surface over the corresponding flow regime map. Transition lines indicate a change of flow regimes enclosing an area of an anticline in the pressure data. In the direct comparison between the calculated and the measured values, the two surfaces show a distinct deviation. Especially, the anticline of the experimental data is not explained by the analytical correlations. Figure 4 depicts the findings of Figure 3 at a constant superficial velocity of 0.0232 m/s. The dominant influence of the flow regimes on the pressure drop becomes apparent, especially in the wedging flow regime. The evident deviation of two-phase flow correlations for the pressure drop is based on omitting the influence of the flow regimes. In conclusion, the study reveals a strong divergence of pressure drop measurements in microscale two-phase flow from established correlations of Lockhart-Martinelli and recognized modifications. In reference to [8, 9], an analytical model incorporating the flow regimes and, hence, predicting the precise pressure drop would be of great benefit for hydrodynamic considerations in microfluidics.


Author(s):  
Mahmood Akbari ◽  
Amin Behzadmehr ◽  
Nicolas Galanis

The single phase and three different two phase models (Volume of fluid, Mixture and Eulerian) are used to analyse laminar mixed convection flow of Al2O3-water nanofluids in a horizontal tube, in order to evaluate their prediction ability. The flow is considered steady and developing. The fluid’s physical properties are temperature dependent whereas those of the solid particles are constant. A uniform heat flux is applied at the fluid-solid interface. Two different Reynolds numbers and three different volume fractions have been considered. The governing three-dimensional partial differential equations are elliptical in all directions and coupled. Predicted convective heat transfer coefficients, velocity, and temperature profiles, as well as secondary flow’s velocity vectors and temperature contours are compared at different axial positions. To validate the comparisons and verify the accuracy of the results, the numerical predictions are compared with corresponding experimental data. There are essentially no differences between the predictions of the two-phase models; however their results are significantly different from those of the single-phase approach. Two-phase model results are closer to the experimental data, but they show an unrealistic increase in heat transfer for small changes of the particle volume fraction. Hydrodynamically, the two-phase and single-phase approaches perform almost the same but their thermal predictions are quite different.


Energetika ◽  
2018 ◽  
Vol 64 (3) ◽  
Author(s):  
Volodymyr Rifert ◽  
Volodymyr Sereda ◽  
Vadim Gorin ◽  
Peter Barabash ◽  
Andrii Solomakha

Since the first work of Tepe and Mueller and until now, there have been published hundreds of studies with the results of heat transfer investigations in vertical and horizontal tubes with vapour condensing of various liquids. Dozens of methods and formulae based both on the results of the theoretical research and on the experimental data have been proposed. The existence of more than 50% discrepancy in different experimental data and various empirical and theoretical relationships is shown. Thus, the absence of both substantiation of different methods and explanations of methods disagreement both between themselves and with different experiments is noted. Also, there are often no remarks concerning boundaries for the use of proposed relationships. There is proposed a simple semi-empirical correlation for heat transfer prediction in condensing inside the plain tubes at the annular and intermediate flow of the phases. This correlation is based on the nature of film condensation process and on the specific features of the results of theoretical solutions. The range of application of complexes, which determine the heat transfer process, is also substantiated. Good convergence of the new method with the experimental data on condensation of steam, carbon dioxide, hydrocarbon refrigerants and other various fluids inside horizontal and vertical tubes is shown.


Author(s):  
A. Bucci ◽  
G. P. Celata ◽  
M. Cumo ◽  
E. Serra ◽  
G. Zummo

This paper reports the results of an experimental investigation of fluid flow and single-phase heat transfer of water in stainless steel capillary tubes. Three tube diameters are tested: 172 μm, 290 μm and 520 μm, while the Reynolds number varying from 200 up to 6000. Fluid flow experimental results indicate that in laminar flow regime the friction factor is in good agreement with the Hagen-Poiseuille theory for Reynolds number below 800–1000. For higher values of Reynolds number, experimental data depart from the Hagen-Poiseuille law to the side of higher f values. The transition from laminar to turbulent regime occurs for Reynolds number in the range 1800–3000. This transition is found in good agreement with the well known flow transition for rough commercial tubes. Heat transfer experiments show that heat transfer correlations in laminar and turbulent regimes, developed for conventional size tubes, are not adequate for calculation of heat transfer coefficient in microtubes. In laminar flow the experimental values of heat transfer coefficient are generally higher than those calculated with the classical correlation, while in turbulent flow regime experimental data do not deviate significantly from classical heat transfer correlations. Deviation from classical heat transfer correlations increase as the channel diameter decrease.


Volume 3 ◽  
2004 ◽  
Author(s):  
Afshin J. Ghajar ◽  
Kapil Malhotra ◽  
Jae-Yong Kim ◽  
Steve A. Trimble

Local heat transfer coefficients and flow parameters were measured for air-water slug flow in a horizontal 25.4 mm stainless steel schedule 10S pipe with a length to diameter ratio of 100. For this systematic study, a total of 83 data points were taken by carefully coordinating the liquid and gas superficial Reynolds number combinations. The heat transfer data were measured under a uniform wall heat flux boundary condition ranging from about 3800 to 16000 W/m2. The superficial Reynolds numbers ranged from about 3160 to 30290 for water and from about 1480 to 5840 for air. Comparison of heat transfer data for slug flow revealed that the heat transfer results were significantly dependent on the liquid and gas superficial Reynolds numbers. Overall, the experimental heat transfer data showed that the liquid phase dominated the heat transfer. However, it was found that the heat transfer data having a fixed liquid superficial Reynolds number showed that the heat transfer coefficients decreased as the gas superficial Reynolds number increased. A general heat transfer correlation for two-phase gas-liquid flow was fitted to our experimental horizontal slug flow heat transfer data with a mean deviation of −2.77% and an RMS deviation of 9.92%. Furthermore, a simplified heat transfer correlation for slug flow was developed based on the trends of heat transfer coefficient over the superficial liquid and gas Reynolds numbers. The proposed correlation predicted the experimental data with a mean deviation of −1.44% and an RMS deviation of 5.15%.


2021 ◽  
Author(s):  
Gamal B. Abdelaziz ◽  
M. Abdelgaleel ◽  
Z.M. Omara ◽  
A. S. Abdullah ◽  
Emad M.S. El-Said ◽  
...  

Abstract This study investigates the thermal-hydraulic characteristics of immiscible two-phase flow (gas/liquid) and heat transfer through porous media. This research topic is interested among others in trickle bed reactors, the reservoirs production of oil, and the science of the earth. Characteristics of two-phase concurrent flow with heat transfer through a vertical, cylindrical, and homogeneous porous medium were investigated both numerically and experimentally. A generalized Darcy model for each phase is applied to derive the momentum equations of a two-phase mixture by appending some constitutive relations. Gravity force is considered through investigation. To promote the system energy equation, the energy equation of solid matrix for each phase are deemed. The test section is exposed to a constant wall temperature after filled with spherical beads. Numerical solution of the model is achieved by the finite volume method. The numerical procedure is generalized such that it can be reduced and applied to single phase flow model. The numerical results are acquired according to, air/water downward flow, spherical beads, ratio of particle diameter to pipe radius D=0.412, porosity φ=0.396, 0.01≤Re≤500, water to air volume ratio 0≤W/A≤∞, and saturation ratio 0≤S1≤1. To validate this model an experimental test rig is designed and constructed, and the corresponding numerical results are compared with its results. Also, the numerical results were compared with other available numerical results. The comparisons show good agreement and validate the numerical model. One of the important results reveals that the heat transfer is influenced by two main parameters; saturation ratios of the two fluids; S1 and S2, and the mixture Reynolds number Re. The thermal entry length is directly dependent on Re, S1, and the thermofluid properties of the fluids. A modified empirical correlation for the entrance length; Xe =0.1 Re.Pr.Rm is predicted, where Rm =Rm(S1, S2, ρ1, ρ2, c1, c2). The predicted correlation is verified by comparing with the supposed correlation of Poulikakos and Ranken (1987) and El-Kady (1997) for a single-phase flow; Xe/Pr=0.1 Re.


Author(s):  
Gian Piero Celata

The objective of the present paper is to provide a general overview of the research carried out so far in single-phase heat transfer and flow in capillary (micro) pipes. Laminar flow and laminar-to-turbulent flow transition are analyzed in detail in order to clarify the discrepancies among the results obtained by different researchers. Experiments performed in the ENEA laboratory indicate that in laminar flow regime the friction factor is in good agreement with the Hagen-Poiseuille theory for Reynolds number below 600–800. For higher values of Reynolds number, experimental data depart from the Hagen-Poiseuille law to the side of higher f values. The transition from laminar-to-turbulent flow occurs for Reynolds number in the range 1800–2500. Heat transfer experiments show that heat transfer correlations in laminar and turbulent regimes, developed for conventional (macro) tubes, are not properly adequate for heat transfer rate prediction in microtubes.


Author(s):  
O.V. Abyzov ◽  
Yu.V. Galyshev ◽  
A.K. Ivanov

Liquid cooling of cylinder and piston parts in highly boosted internal combustion engines is generally accompanied by local phase transition phenomena, such as surface nucleate boiling. The heat transfer coefficient of nucleate boiling is several times higher than that of single-phase convection. In order to efficiently exploit the thermal effect of nucleate boiling in cooling systems, simultaneously preventing emergency supercritical modes, a deeper understanding of boiling physics based on full-scale experiments is required. We conducted experimental investigation of heat transfer in a simulated cooling duct of a piston engine cylinder head, using a bespoke motor-free installation. We studied the effects of velocity, flow character and coolant type on the heat transfer, accounting for the presence of congestion regions. Over the course of the experiment, we simulated thermal conditions characteristic of different heat transfer types: single-phase convection, nucleate boiling, the onset of boiling crisis. We used the experimental data to plot the coolant heat flow density as a function of wall temperature for different measuring points situated inside the stream and the turbulent flow regions (congestion regions). We show that the mature nucleate boiling mode is the most favourable in terms of how uniform the temperature field within a part is. The experimental data obtained during the investigation may be used to verify mathematical simulations in the two-phase heat transfer theory, provided the data have been appropriately processed


Sign in / Sign up

Export Citation Format

Share Document