scholarly journals Dynamic Performance Analysis of VSC-HVDC Based Modular Multilevel Converter under Fault

2021 ◽  
Vol 54 (1) ◽  
pp. 187-194
Author(s):  
Abdelhalim Yahiaoui ◽  
Koussaila Iffouzar ◽  
Kaci Ghedamsi ◽  
Kamal Himour

The use of high voltage direct current based voltage source converter (VSC-HVDC) in power transmission systems knows a great progress in recent years. Above all, with the new generation of power electronics converters such as the modular multi-level converter (MMC), with his scalable structure it can theoretically meet any voltage level requirement, which allows to increase the size of the power transferred compared to conventional converters. In this sense, this paper presents a study of a VSC-HVDC system based on a modular multi-level converter (MMC). The main objective of this work is to analyze the performance of the VSC-HVDC system based MMC without the AC filters and its control in the event of a fault, during set point changes and unbalanced grid conditions. After realization a mathematical model of the system studied and its control, simulations are done over in Simpower System/Matlab. The results obtained confirm the robustness of the system control and the system gives a good energy quality, that manifests by a good output currant and voltage curves with no need to use a voluminous AC filter.

Theoretical review of various topologies of high voltage DC links in application to off shore wind forms has been studied and analysed. In addition to that, various types of high voltage DC links such as back to back, two terminal, multi-terminal systems has been covered under this study. The Line-Commutated Converters, Voltage Source Converter, Modular Multi-Level Converter as well as some of advanced hybrid high voltage DC topologies in application to off shore wind forms has been reviewed. This study covers complication arising from large-scale wind power generation. The review paper also points out the scope of future research in high voltage DC converters.


2017 ◽  
Vol 2017 ◽  
pp. 1-10 ◽  
Author(s):  
Jie Huang ◽  
Dezhi Xu ◽  
Wenxu Yan ◽  
Le Ge ◽  
Xiaodong Yuan

This paper proposed a command-filtered backstepping controller to improve the dynamic performance of back-to-back voltage-source-converter high voltage direct current (BTB VSC-HVDC). First, the principle and model of BTB VSC-HVDC in abc and d-q frame are described. Then, backstepping method is applied to design a controller to maintain the voltage balance and realize coordinated control of active and reactive power. Meanwhile, command filter is introduced to deal with the problem of input saturation and explosion of complexity in conventional backstepping, and a filter compensation signal is designed to diminish the adverse effects caused by the command filter. Next, the stability and convergence of the whole system are proved via the Lyapunov theorem of asymptotic stability. Finally, simulation results are given to demonstrate that proposed controller has a better dynamic performance and stronger robustness compared to the traditional PID algorithm, which also proves the effectiveness and possibility of the designed controller.


Relieving congestion is a major technical issue in power transmission systems. In this paper, simultaneous placement of Thyristor controlled series capacitors (TCSC) and Voltage source converter based distribution generators (VSC-DG) are used for relieving congestion, minimize system cost and maintain the system in secure state. The system has been analyzed in three stages: (i) first stage, the congestions are made in different transmission network by overload and line outages, (ii) second stage, relieving congestion of transmission lines by using TCSC and VSCDG, where these devices are placed simultaneously at their optimal locations, (iii) comparative cost analysis is done between normal and congested systems. The proposed approach is tested on the 62-bus Indian power system network. The optimal solution of the test systems are obtained by genetic algorithm method and its solutions are compared with primal linear programming. All the results are validated through Power World Simulator and GA toolbox in MATLAB.


PLoS ONE ◽  
2020 ◽  
Vol 15 (11) ◽  
pp. e0242316 ◽  
Author(s):  
Junfang Hao ◽  
Jinhai Huang ◽  
Ailing Zhang ◽  
Hongjie Ai ◽  
Qun Zhang ◽  
...  

Nowadays, with the significant integration of various renewable energy, hybrid alternating current/ voltage source converter based high voltage direct current (AC/VSC-HVDC) system integrated with doubly-fed induction generator (DFIG) has achieved rapidly development in smart grid. A proper control system design for hybrid AC/VSC-HVDC system plays a very crucial role for a reliable and effective power transmission. Hence, this paper designs a novel cooperative beetle antenna search (CBAS) algorithm for optimal coordinated control of hybrid AC/VSC-HVDC system integrated with DFIG. Compared with original beetle antennae search (BAS) algorithm, CBAS algorithm can significantly improve searching efficiency via an efficient cooperation with a group of multiple beetles instead of a single beetle. Particularly, CBAS algorithm can effectively escape from local optimums thanks to its dynamic balance mechanism, which can maintain appropriate trade-off between global exploration and local exploitation. Moreover, three case studies are undertaken to validate the effectiveness and superiorities and effectiveness of CBAS algorithm compared against that of other traditional meta-heuristic algorithms. Especially, the average results of fitness function acquired by CBAS algorithm is merely 46.05%, 41.18%, and 47.82% of that of PSO, GA, and BAS algorithm, respectively.


2020 ◽  
Author(s):  
Ziya Özkan ◽  
Ahmet Masum Hava

In three-phase three-wire (3P3W) voltage-source converter (VSC) systems, utilization of filter inductors with deep saturation characteristics is often advantageous due to the improved size, cost, and efficiency. However, with the use of conventional synchronous frame current control (CSCC) methods, the inductor saturation results in significant dynamic performance loss and poor steady-state current waveform quality. This paper proposes an inverse dynamic model based compensation (IDMBC) method to overcome these performance issues. Accordingly, a review of inductor saturation and core materials is performed, and the motivation on the use of saturable inductors is clarified. Then, two-phase exact modelling of the 3P3W VSC control system is obtained and the drawbacks of CSCC have been demonstrated analytically. Based on the exact modelling, the inverse system dynamic model of the nonlinear system is obtained and employed such that the nonlinear plant is converted to a fictitious linear inductor system for linear current regulators to perform satisfactorily.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3097
Author(s):  
Roberto Benato ◽  
Antonio Chiarelli ◽  
Sebastian Dambone Sessa

The purpose of this paper is to highlight that, in order to assess the availability of different HVDC cable transmission systems, a more detailed characterization of the cable management significantly affects the availability estimation since the cable represents one of the most critical elements of such systems. The analyzed case study consists of a multi-terminal direct current system based on both line commutated converter and voltage source converter technologies in different configurations, whose availability is computed for different transmitted power capacities. For these analyses, the matrix-based reliability estimation method is exploited together with the Monte Carlo approach and the Markov state space one. This paper shows how reliability analysis requires a deep knowledge of the real installation conditions. The impact of these conditions on the reliability evaluation and the involved benefits are also presented.


2013 ◽  
Vol 3 (2) ◽  
Author(s):  
Guo-Jie Li ◽  
Si-Ye Ruan ◽  
Tek Lie

AbstractA multi-terminal voltage-source-converter (VSC) based high voltage direct current (HVDC) system is concerned for its flexibility and reliability. In this study, a control strategy for multiple VSCs is proposed to auto-share the real power variation without changing control mode, which is based on “dc voltage droop” power regulation functions. With the proposed power regulation design, the multiple VSCs automatically share the real power change and the VSC-HVDC system is stable even under loss of any one converter while there is no overloading for any individual converter. Simulation results show that it is effective to balance real power for power disturbance and thus improves operation reliability for the multi-terminal VSC-HVDC system by the proposed control strategy.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2260
Author(s):  
Fan Cheng ◽  
Lijun Xie ◽  
Zhibing Wang

This paper investigated the characteristics of a novel type of hybrid high voltage direct current (HVdc) converter, which is composed by line commutated converter series with voltage source converter. The system and valve level control strategies are introduced, which can provide ac system voltage support. A novel filter design scheme composed by resonant filers for hybrid HVdc are also proposed, which can decrease the capacity of reactive power compensation equipment without deteriorate harmonic characteristics. The ac voltage of HVdc fluctuation level caused by transmitted power variation will be effectively reduced, with the coordination between filter design scheme and converter control. In addition, the influence of ac grid strength is also analyzed by equivalent source internal impedance represented by short circuit ratio (SCR). Finally, the +800 kV/1600 MW hybrid HVdc system connecting two ac grids under different SCR cases are studied, and the PSCAD/EMTDC simulation results have validated the effectiveness for proposed strategy.


Energies ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3554
Author(s):  
Naushath M. Haleem ◽  
Athula D. Rajapakse ◽  
Aniruddha M. Gole ◽  
Ioni T. Fernando

A selective fault clearing scheme is proposed for a hybrid voltage source converter (VSC)-line commutated converter (LCC) multi-terminal high voltage direct current (HVdc) transmission structure in which two small capacity VSC stations tap into the main transmission line of a high capacity LCC-HVdc link. The use of dc circuit breakers (dc CBs) on the branches connecting to VSCs at the tapping points is explored to minimize the impact of tapping on the reliability of the main LCC link. This arrangement allows clearing of temporary faults on the main LCC line as usual by force retardation of the LCC rectifier. The faults on the branches connecting to VSC stations can be cleared by blocking insulated gate bipolar transistors (IGBTs) and opening ac circuit breakers (ac CB), without affecting the main line’s performance. A local voltage and current measurement based fault discrimination scheme is developed to identify the faulted sections and pole(s), and trigger appropriate fault recovery functions. This fault discrimination scheme is capable of detecting and discriminating short circuits and high resistances faults in any branch well before 2 ms. For the test grid considered, 6 kA, 2 ms dc CBs can easily facilitate the intended fault clearing functions and maintain the power transfer through healthy pole during single-pole faults.


Sign in / Sign up

Export Citation Format

Share Document