UNJUK KERJA COOL BOX BERBASIS THERMOELEKTRIK COOLER DENGAN SINGLE DAN MULTI-STAGE TERMOELEKTRIK

ROTOR ◽  
2020 ◽  
Vol 12 (2) ◽  
pp. 28
Author(s):  
Munawir Munawir ◽  
Mega Nur Sasongko ◽  
Nurkholis Hamidi

Thermoelectric technology works by converting thermal energy into electricity directly or preferably.  Thermoelectric technology works by converting thermal energy into electricity directly or preferably. Theuse of thermoelectric as a cooler in cool box systems has been extensively studied. The thermoelectric cool ability can be achieved depending on the design of a good system. Therefore, this study aims to determine the performance of thermoelectric cooler cool box based on single and multi stage. Tests carried out using cool boxes of dimensions of 31 cm x 19 cm x 24 cm witha thickness of 3 cm and with the TEC1 12706 module. The voltage used in each configuration is 12 Volts. Temperature data readings on laptops using DAQNavi_SDK data logger connected to type K thermocouples. The result showed the multi stage configuration reached a room temperature of around 19.3 oC and 21.8 oC for single stage. Meanwhile, the multi stage configuration COP value is 1.36 and with a single stage configuration is0.88. It can be concluded that the thermoelectric configuration has an influence on the performance of the cool box system. Keywords: Cool box, Thermoelectric module, Multi stage, single stage, COP

2017 ◽  
Vol 6 (1) ◽  
pp. 29 ◽  
Author(s):  
Azridjal Aziz ◽  
Rahmat Iman Mainil ◽  
Afdhal Kurniawan Mainil ◽  
Sayfri Syafri ◽  
Muhammad Faizal Syukrillah

The Portable Beverage Cooler (PBC) has been designed to satisfy the need of cooler apparatus that could be carried easily. The utilization of this apparatus was intended to minimize the environmental damage affected by vapour compression refrigeration system using CFCs Refrigerant. The peltier effect from thermoelectric module was utilized in this PBC and called as Thermoelectric Cooler (TEC). Furthermore, heat-sink and fan were needed to ensure the cooling effect continously worked. To achieved the objectives of this machine (portable, environment-friendly, low watt, affordable), the design consideration are heat load, insulating material, weight of components, electric consumption, and dimension of the cooling box.  The results of the design shows the PBC cooling box dimension is 6 cm x 6.5 x 15 cm. The insulation of the PBC cooling box are polyurethane foam and polystyrene expanded with thickness 6 mm and 5.3 mm, respectively. The alumunium plate was applied as inner wall to enhance the cooling capacity of cooling room temperature. In this PBC was used one stage of TEC that could yield cooling room temperature until 15 oC in 30 minutes operation by consuming 20 W of electricity. 


Author(s):  
Rotimi Adedayo Ibikunle ◽  
Mutalubi Aremu Akintunde ◽  
Isaac Femi Titiladunayo ◽  
Adekunle Akanni Adeleke

Abstract In this study, a single stage thermoelectric cooler (TER, of size: 21 × 14.2 × 13.5 cm) with thermoelectric module (TEM, of type inbc1-127. 05 with size 40 × 40 × 4.0 mm) and applied electrical power of 30 W and current of 2.5 A, was adopted to estimate the coefficient of performance (COP) of thermoelectric refrigerator (TER). The TER uses a fan to cool the heat exchange region of the TEM. The temperature of the fruit/vegetable samples used in this study was taken before and after cooling for a specific period. The temperatures at both the hot and cold sides of the TEM were also taken at every specific cooling period. The experimented TER can cool vegetable/fruit from about 27 to 5°C within 3 h. The aim of this study is to determine the COP of TER to ascertain the possible applications. The temperature gradient at the heat exchange section of TEM was used to estimate the average theoretical COP to be 0.99, the heat extracted from the cooling chamber and the power supplied was used to estimate the average practical cooling COP to be 0.52; which is within 0.4–0.7 standard COP for a single stage type of TER.


2013 ◽  
Vol 38 (2) ◽  
pp. 213-222 ◽  
Author(s):  
Sudhanshu Sharma ◽  
V.K Dwivedi ◽  
S.N. Pandit

2018 ◽  
Vol 24 (4) ◽  
pp. 387-397 ◽  
Author(s):  
Yi Liu ◽  
Li Chen ◽  
Jun Zhou ◽  
Zongcheng Yan

Ionic liquids-based aqueous two-phase extraction (ILs-ATPE) offers an alternative approach to the extraction of tetracycline (TC) through their partitioning between two phases. Single-stage and multi-stage strategies have been evaluated and compared for the purification of TC using ATPE composed of 1-butyl-3-methylimidazolium halide ([Bmim]X(X=Cl,Br)) and K2HPO4. The influence factors on single-stage extraction behavior of TC were optimized systematically, including the pH value, tie line length, and volume ratio. The optimal extraction efficiency of TC could reach above 95% when the volume ratio is higher than 1.5 and the tie line length is 30.52%. The multi-stage ATPE was also investigated by simulating a three-stage crosscurrent operation in test tubes. According to the TC isotherm curve and respective McCabe?Thiele diagrams, a predicted optimized scheme of the countercurrent multi-stage ATPE was determined. TC can be purified in the IL-rich top phase with a final extraction efficiency of 99% and a final TC concentration of 0.25 mg/mL, if a three- -stage [Bmim]Cl-K2HPO4 ATPE with volume ratio of 0.5 and tie line length of 30.52% was employed. Thus, the multi-stage extraction with small volume ratio is necessary to achieve a higher recovery yield, resulting in the reduction of the IL consumption.


Energetika ◽  
2021 ◽  
Vol 67 (1) ◽  
Author(s):  
Harun Yilmaz ◽  
Omer Cam ◽  
Ilker Yilmaz

Swirling flows increase combustion performance via favouring flame stability, pollutant emissions, and combustion intensity. The strength of a swirling flow is characterized by a parameter known as swirl number, which is highly related to the dh/do ratio. In this study, effects of the swirler dh/do ratio on combustion and emission characteristics of the synthetic gas flames of premixed 20%CNG/30%H2/30%CO/20%CO2 mixture were experimentally investigated in a laboratory-scale swirl stabilized combustor. For this purpose, twelve different swirl generators were designed and manufactured. dh/do ratios of these swirlers were set as 0.30 and 0.50, and the geometric swirl number was varied between the values of 0.4 and 1.4 (at 0.2 intervals). All experiments were conducted at a fuel-lean equivalence ratio (ϕ = 0.6), room temperature, and local atmospheric conditions of the city of Kayseri, Turkey. A data logger was utilized to plot axial and radial temperatures and NOx, CO, and CO2 profiles, which were exploited to assess combustion and emission performance. Results showed that the dh/do ratio had a non-monotonic effect on the behaviour of combustion and emission of the tested synthetic gas mixture. Depending on the swirl number, increments and decrements were observed in temperature and emission values.


Author(s):  
Jeremy Spitzenberger ◽  
Pengtao Wang ◽  
Laith Ismael ◽  
Hongbin Ma ◽  
Ahmad Abuheiba ◽  
...  

Abstract Ejector driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this investigation, a single-stage gas-fired ejector heat pump (EHP) is investigated and thermodynamically modeled in order to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) temperatures on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120-180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Results show that an optimized COP of the EHP system exists which depends on HTE and LTE temperatures, primary nozzle throat diameters. In addition, it is found that the EHP COP is independent of the ejector COP. From this investigation a maximum EHP COP of 1.31 is able to be achieved for a HTE temperature of 160 °C and a LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.


Sign in / Sign up

Export Citation Format

Share Document