scholarly journals A betacoronavirus multiplex microsphere immunoassay detects early SARS-CoV-2 seroconversion and antibody cross reactions

Author(s):  
Eric Laing ◽  
Spencer Sterling ◽  
Stephanie Richard ◽  
Nusrat Epsi ◽  
Shreshta Phogat ◽  
...  

Abstract Sensitive and specific SARS-CoV-2 antibody assays remain critical for community and hospital-based SARS-CoV-2 surveillance. Here, we developed and applied a multiplex microsphere-based immunoassay (MMIA) for COVD-19 antibody studies that incorporates spike protein trimers of SARS-CoV-2, SARS-CoV-1, MERS-CoV, and the seasonal human betacoronaviruses, HCoV-HKU1 and HCoV-OC43, that enables measurement of off-target pre-existing cross-reactive antibodies. The MMIA performances characteristics are: 98% sensitive and 100% specific for human subject samples collected as early as 10 days from symptom onset. The MMIA permitted the simultaneous identification of SARS-CoV-2 seroconversion and the induction of SARS-CoV-2 IgG antibody cross reactions to SARS-CoV-1 and MERS-CoV. Further, synchronous increases of HCoV-OC43 IgG antibody levels was detected with SARS-CoV-2 seroconversion in a subset of subjects for whom early infection sera were available prior to their SARS-CoV-2 seroconversion, suggestive of an HCoV-OC43 memory response triggered by SARS-CoV-2 infection.

2021 ◽  
Author(s):  
Jira Chansaenroj ◽  
Ritthideach Yorsaeng ◽  
Nasamon Wanlapakorn ◽  
Chintana Chirathaworn ◽  
Natthinee Sudhinaraset ◽  
...  

Abstract Understanding antibody responses after natural severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection can guide the coronavirus disease 2019 (COVID-19) vaccine schedule. This study aimed to assess the dynamics of SARS-CoV-2 antibodies, including anti-spike protein 1 (S1) immunoglobulin (Ig)G, anti-receptor-binding domain (RBD) total Ig, anti-S1 IgA, and neutralizing antibody against wild-type SARS-CoV-2 in a cohort of patients who were previously infected with SARS-CoV-2. Between March and May 2020, 531 individuals with virologically confirmed cases of SARS-CoV-2 infection were enrolled in our immunological study. The neutralizing titers against SARS-CoV-2 were detected in 95.2%, 86.7%, 85.0%, and 85.4% of recovered COVID-19 patients at 3, 6, 9, and 12 months after symptom onset, respectively. The seropositivity rate of anti-S1 IgG, anti-RBD total Ig, anti-S1 IgA, and neutralizing titers remained at 68.6%, 89.6%, 77.1%, and 85.4%, respectively, at 12 months after symptom onset. The half-life of neutralizing titers was estimated at 100.7 days (95% confidence interval = 44.5 – 327.4 days, R2 = 0.106). These results support that the decline in serum antibody levels over time depends on the symptom severity, and the individuals with high IgG antibody titers experienced a significantly longer persistence of SARS-CoV-2-specific antibody responses than those with lower titers.


2006 ◽  
Vol 13 (1) ◽  
pp. 123-131 ◽  
Author(s):  
Jeffrey W. Priest ◽  
Caryn Bern ◽  
Lihua Xiao ◽  
Jacquelin M. Roberts ◽  
James P. Kwon ◽  
...  

ABSTRACT Cryptosporidium species are ubiquitous in the environment and are frequently detected in the stools of children who live where sanitation conditions are poor. To better characterize the immune response to these parasites, we monitored immunoglobulin G (IgG) antibody levels in a cohort of children from Lima, Peru. Two new enzyme-linked immunosorbent assays based on the C. parvum (bovine, subtype IIa) Iowa strain 17-kDa and 27-kDa antigens were used to measure IgG antibody levels in longitudinal serum samples. Antibody responses were detected during infections with C. parvum, C. felis, and C. meleagridis and with four different subtypes of C. hominis. We also noted that the magnitude of the antibody response was related to the number of previous infections and that older children generally had higher levels of antibodies to the two C. parvum antigens. Antibody responses were not associated with infections with either Cyclospora sp. or Giardia sp. We believe the antibody assays will be important tools for monitoring the success of future public health interventions.


Vaccines ◽  
2021 ◽  
Vol 9 (10) ◽  
pp. 1063
Author(s):  
Jürgen Held ◽  
Jan Esse ◽  
Koray Tascilar ◽  
Philipp Steininger ◽  
Kilian Schober ◽  
...  

mRNA vaccines against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), such as BNT162b2 (Comirnaty®), have proven to be highly immunogenic and efficient but also show marked reactogenicity, leading to adverse effects (AEs). Here, we analyzed whether the severity of AEs predicts the antibody response against the SARS-CoV-2 spike protein. Healthcare workers without prior SARS-CoV-2 infection, who received a prime-boost vaccination with BNT162b2, completed a standardized electronic questionnaire on the duration and severity of AEs. Serum specimens were collected two to four weeks after the boost vaccination and tested with the COVID-19 ELISA IgG (Vircell-IgG), the LIAISON® SARS-CoV-2 S1/S2 IgG CLIA (DiaSorin-IgG) and the iFlash-2019-nCoV NAb surrogate neutralization assay (Yhlo-NAb). A penalized linear regression model fitted by machine learning was used to correlate AEs with antibody levels. Eighty subjects were enrolled in the study. Systemic, but not local, AEs occurred more frequently after the boost vaccination. Elevated SARS-CoV-2 IgG antibody levels were measured in 92.5% of subjects with Vircell-IgG and in all subjects with DiaSorin-IgG and Yhlo-NAb. Gender, age and BMI showed no association with the antibody levels or with the AEs. The linear regression model identified headache, malaise and nausea as AEs with the greatest variable importance for higher antibody levels (Vircell-IgG and DiaSorin-IgG). However, the model performance for predicting antibody levels from AEs was very low for Vircell-IgG (squared correlation coefficient r2 = 0.04) and DiaSorin-IgG (r2 = 0.06). AEs did not predict the surrogate neutralization (Yhlo-NAb) results. In conclusion, AEs correlate only weakly with the SARS-CoV-2 spike protein antibody levels after COVID-19 vaccination with BNT162b2 mRNA.


BMJ Open ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. e048142
Author(s):  
Louise J Robertson ◽  
Julie S Moore ◽  
Kevin Blighe ◽  
Kok Yew Ng ◽  
Nigel Quinn ◽  
...  

ObjectiveTo evaluate the dynamics and longevity of the humoral immune response to SARS-CoV-2 infection and assess the performance of professional use of the UK-RTC AbC-19 Rapid Test lateral flow immunoassay (LFIA) for the target condition of SARS-CoV-2 spike protein IgG antibodies.DesignNationwide serological study.SettingNorthern Ireland, UK, May 2020–February 2021.ParticipantsPlasma samples were collected from a diverse cohort of individuals from the general public (n=279), Northern Ireland healthcare workers (n=195), pre-pandemic blood donations and research studies (n=223) and through a convalescent plasma programme (n=183). Plasma donors (n=101) were followed with sequential samples over 11 months post-symptom onset.Main outcome measuresSARS-CoV-2 antibody levels in plasma samples using Roche Elecsys Anti-SARS-CoV-2 IgG/IgA/IgM, Abbott SARS-CoV-2 IgG and EuroImmun IgG SARS-CoV-2 ELISA immunoassays over time. UK-RTC AbC-19 LFIA sensitivity and specificity, estimated using a three-reference standard system to establish a characterised panel of 330 positive and 488 negative SARS-CoV-2 IgG samples.ResultsWe detected persistence of SARS-CoV-2 IgG antibodies for up to 10 months post-infection, across a minimum of two laboratory immunoassays. On the known positive cohort, the UK-RTC AbC-19 LFIA showed a sensitivity of 97.58% (95.28% to 98.95%) and on known negatives, showed specificity of 99.59% (98.53 % to 99.95%).ConclusionsThrough comprehensive analysis of a cohort of pre-pandemic and pandemic individuals, we show detectable levels of IgG antibodies, lasting over 46 weeks when assessed by EuroImmun ELISA, providing insight to antibody levels at later time points post-infection. We show good laboratory validation performance metrics for the AbC-19 rapid test for SARS-CoV-2 spike protein IgG antibody detection in a laboratory-based setting.


2021 ◽  
Author(s):  
Masaaki Takeuchi ◽  
Yukie Higa ◽  
Akina Esaki ◽  
Yosuke Nabeshima ◽  
Akemi Nakazono

Adverse reactions are more common after the second injection of messenger RNA vaccines such as Pfizer/BioNTech's BNT162b2. We hypothesized that the degree and severity of reactogenicity after the second injection reflects the magnitude of antibody production against the SARS CoV-2 virus spike protein (spike IgG). Blood samples were obtained from 67 healthy Japanese healthcare workers three weeks after the first injection and two weeks after the second injection of the BNT162b2 vaccine to measure spike IgG levels. Using questionnaires, we calculated an adverse event (AE) score (0-11) for each participant. The geometric mean of spike IgG titers increased from 1,047 antibody units (AU/mL) (95% CI: 855±1282 AU/mL) after the first injection to 17,378 AU/mL (14,622±20,663 AU/mL) after the second injection. The median AE score increased from 2 to 5. Spike IgG levels after the second injection were negatively correlated with age and positively correlated with spike IgG after the first injection. AE scores after the second injection were not significantly associated with log-transformed spike IgG after the second injection, when adjusted for age, sex, and log-transformed spike IgG after the first injection. Although the sample size was relatively small, reactogenicity after the second injection may not accurately reflect antibody production.


Author(s):  
Kai Wang ◽  
Quan-Xin Long ◽  
Hai-Jun Deng ◽  
Jie Hu ◽  
Qing-Zhu Gao ◽  
...  

Background Coronavirus disease 2019 (COVID-19) is a global pandemic with no licensed vaccine or specific antiviral agents for therapy. Little is known about the longitudinal dynamics of SARS-CoV-2-specific neutralizing antibodies (NAbs) in COVID-19 patients. Methods Blood samples (n=173) were collected from 30 COVID-19 patients over a 3-month period after symptom onset and analyzed for SARS-CoV-2-specific NAbs, using the lentiviral pseudotype assay, coincident with the levels of IgG and proinflammatory cytokines. Results SARS-CoV-2-specific NAb titers were low for the first 7-10 d after symtom onset and increased after 2-3 weeks. The median peak time for NAbs was 33 d (IQR 24-59 d) after symptom onset. NAb titers in 93.3% (28/30) of the patients declined gradually over the 3-month study period, with a median decrease of 34.8% (IQR 19.6-42.4%). NAb titers increased over time in parallel with the rise in IgG antibody levels, correlating well at week 3 (r = 0.41, p < 0.05). The NAb titers also demonstrated a significant positive correlation with levels of plasma proinflammatory cytokines, including SCF, TRAIL, and M-CSF. Conclusions These data provide useful information regarding dynamic changes in NAbs in COVID-19 patients during the acute and convalescent phases.


Author(s):  
Benjamin T. Bradley ◽  
Andrew Bryan ◽  
Susan L. Fink ◽  
Erin A. Goecker ◽  
Pavitra Roychoudhury ◽  
...  

With the availability of widespread SARS-CoV-2 vaccination, high-throughput quantitative anti-spike serological testing will likely become increasingly important. Here, we investigated the performance characteristics of the recently FDA authorized semi-quantitative anti-spike AdviseDx SARS-CoV-2 IgG II assay compared to the FDA authorized anti-nucleocapsid Abbott Architect SARS-CoV-2 IgG, Roche elecsys Anti-SARS-CoV-2-S, EuroImmun Anti-SARS-CoV-2 ELISA, and GenScript surrogate virus neutralization assays and examined the humoral response associated with vaccination, natural protection, and breakthrough infection. The AdviseDx assay had a clinical sensitivity at 14 days post-symptom onset or 10 days post PCR detection of 95.6% (65/68, 95% CI: 87.8-98.8%) with two discrepant individuals seroconverting shortly thereafter. The AdviseDx assay demonstrated 100% positive percent agreement with the four other assays examined using the same symptom onset or PCR detection cutoffs. Using a recently available WHO International Standard for anti-SARS-CoV-2 antibody, we provide assay unit conversion factors to international units for each of the assays examined. We performed a longitudinal survey of healthy vaccinated individuals, finding median AdviseDx immunoglobulin levels peaked seven weeks post-first vaccine dose at approximately 4,000 IU/mL. Intriguingly, among the five assays examined, there was no significant difference in antigen binding level or neutralizing activity between two seropositive patients protected against SARS-CoV-2 infection in a previously described fishing vessel outbreak and five healthcare workers who experienced vaccine breakthrough of SARS-CoV-2 infection – all with variants of concern. These findings suggest that protection against SARS-CoV-2 infection cannot currently be predicted exclusively using in vitro antibody assays against wildtype SARS-CoV-2 spike. Further work is required to establish protective correlates for SARS-CoV-2 infection.


Author(s):  
Megan Zilla ◽  
Bradley J Wheeler ◽  
Christian Keetch ◽  
Gretchen Mitchell ◽  
Jeffrey McBreen ◽  
...  

Abstract Objectives Serologic detection of prior severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is needed for definition of convalescent plasma donors, for confounding SARS-CoV-2 presentation, and for seroprevalence studies. Reliable serologic assays with independent validation are required. Methods Six SARS-CoV-2 antibody assays from Beckman Coulter, Euroimmun (IgG, IgA), Roche, and Siemens (Centaur, Vista) were assessed for specificity (n = 184), sensitivity (n = 154), and seroconversion in a defined cohort with clinical correlates and molecular SARS-CoV-2 results. Results Assay specificity was 99% or greater for all assays except the Euroimmun IgA (95%). Sensitivity at more than 21 days from symptom onset was 84%, 95%, 72%, 98%, 67%, and 96% for Beckman Coulter, Centaur, Vista, Roche, Euroimmun IgA, and Euroimmun IgG, respectively. Average day of seroconversion was similar between assays (8-10 d), with 2 patients not producing nucleocapsid antibodies during hospitalization. Conclusions SARS-CoV-2 nucleocapsid antibodies may be less reliably produced early in disease than spike protein antibodies. Assessment of convalescent plasma donors at more than 30 days from symptom onset and seroprevalence studies should use assays with defined sensitivity at time points of interest because not all assays detected antibodies reliably at more than 30 days.


2021 ◽  
pp. 1-5
Author(s):  
Mitra Rezaei ◽  
Mohammadhadi Sadeghi ◽  
Alireza Korourian ◽  
Payam Tabarsi ◽  
Mihan Porabdollah ◽  
...  

BACKGROUND: There are few studies to compare antibody response against anti-spike (S) and anti- nucleoprotein (N) SARS-CoV-2. OBJECTIVE: The aim of this study was to evaluate the IgG antibody production against S and N antigens of the virus and their correlation with the time and severity of the disease. METHODS: The IgG antibodies against S and N antigens of SARS-CoV-2 in serum specimens 72 symptomatic patients who tested real-time reverse transcription polymerase chain reaction positive for SARS-CoV-2 were detected using the ELISA technique. Different antibody response was compared and the correlation with the time from disease onset and the severity was evaluated. RESULTS: Forty-eight of 72 (67%) patients tested positive for anti-SARS-CoV-2 antibodies, while 24 (33%) did not have detectable antibodies. Comparison of antibody levels for N and S antibodies showed that they correlate with each other well (r= 0.81; P< 0.001). However, sensitivity of anti-S SARS-CoV-2 IgG and anti-N SARS-CoV-2 IgG was 30% and 60%, during the first 7 days after symptom onset (r= 0.53; P= 0.111), but increased to 73% and 68% at more than 1-week post symptom onset (r= 0.89, P= 0.111), respectively. Cases with positive IgG response showed a decreased CD8 cell percentage compared to the negative IgG groups (26 ± 14 vs. 58 ± 32, p= 0.066 in anti-N IgG group and 28 ± 15 vs. 60 ± 45, p= 0.004 in anti-S IgG group, respectively). CONCLUSION: Nearly one-third of the confirmed COVID-19 patients had negative serology results. Lower percent positivity at early time points after symptom onset (less than 1 week) was seen using anti-S SARS-COV-2 IgG kit compare to the anti-N SARS-CoV-2 IgG; therefore, clinicians should interpret negative serology results of especially anti-S SARS-CoV-2 IgG with caution.


2021 ◽  
Author(s):  
Thomas Perkmann ◽  
Thomas Koller ◽  
Nicole Perkmann-Nagele ◽  
Miriam Klausberger ◽  
Mark Duerkop ◽  
...  

AbstractObjectivesSARS-CoV-2 infection induces the formation of different antibodies. However, not all of which might prevent the virus from entering the cell, although their concentrations correlate with the titers of viral neutralization tests (NTs). Antibodies against the viral nucleocapsid (NC), e.g., can be classified as such. We aimed to prove the hypothesis that the apparent correlation between NC-antibody levels and NT-titers is mediated by simultaneously occurring antibodies against viral spike-protein components.MethodsWe included 64 individuals with previous SARS-CoV-2 infection (>14d after symptom onset). SARS-CoV-2 antibodies against the NC (Roche total antibody ECLIA, Abbott IgG CMIA) and spike-protein (Technozym RBD ELISA, DiaSorin S1/S2 CLIA) were measured, and neutralization tests were performed. The effect of spike-protein antibodies on the correlation between NC-antibodies and NT-titers was evaluated by partial correlation and mediation analyses.ResultsBoth tested assays assessing antibodies against the NC correlated significantly with NT titers: Abbott ρ=0.742, P<0.0001; Roche ρ=0.365, P<0.01. However, when controlling the rank correlations for the presence of RBD or S1/S2 antibodies, correlation coefficients dropped to ρ=0.318/ρ=0.329 (P<0.05/P<0.01), respectively for Abbott and vanished for Roche. As a result, only a maximum of 11% of NT titer variability could be explained by NC-antibody levels.ConclusionsOur data suggest that the apparent correlation between NC antibodies and NT titers is strongly mediated by co-occurring RBD antibody concentrations. To avoid falsely implied causal relationships, all correlation analyses of non-spike-associated antibody assays and neutralization assays should include a partial correlation analysis to exclude a possible mediator effect of spike-associated antibodies.


Sign in / Sign up

Export Citation Format

Share Document