scholarly journals Numerical Simulation of Pore Water Distribution Under Electric Field in Unsaturated Soils

Author(s):  
Yimin Liu ◽  
Chuntai Xu ◽  
Xiada Zhu

Abstract A numerical model predicting the moisture distribution under external electric field in unsaturated soils is established. Key parameters including matric potential, hydraulic and electrical permeability coefficient and electric conductivity are discussed. The simulation results are in good agreement with the measured data from literaturea, which verify exactness and suitability of the model. In general, the moisture contents decrease with time under the action of external electric force and matrix suction. A slight increase in moisture contert was observed in the anodic area at the beginning of the treatment. The electro-osmosis treatment effect can be enhanced by improving the voltage gradient or weaken the voltage loss at electrode. The limit value of electroosmosis treatment in moisture content is observed and the method can only be applied on the soil with moisture content higher than the limit value.

Polymers ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1219 ◽  
Author(s):  
Daning Zhang ◽  
Guanwei Long ◽  
Yang Li ◽  
Haibao Mu ◽  
Guanjun Zhang

In order to realize the diagnosis of water distribution, this paper analyzes the interface polarization and macroscopic space charge polarization mechanism when the water distribution is non-uniform. The experimental results of this paper and bushing show that when the moisture distribution is non-uniform, there is a significant loss peak in the tanδ-f curve. The loss peak shifts to higher frequencies as the non-uniformity coefficient increases. There are common intersection points between multiple tanδ-f curves. Further, this paper realizes the diagnosis of the location of moisture distribution through Frequency Domain Spectroscopy (FDS) testing of different voltages and different wiring methods based on the macroscopic space charge polarization. In the single-cycle FDS test, when the positive electrode is first added to the area with higher moisture content, the amplitude of the tanδ-f curve is smaller. The tanδ-f curves under different wiring methods constitute a “ring-shaped” loss peak. As the voltage increases, the peak value of the loss peak shifts to the lower frequency band. As the temperature increases, the peak value of the loss peak shifts to higher frequencies. Based on the above rules and mechanism analysis, this research provides a new solution for the evaluation of moisture content of oil-immersed polymers equipment.


2001 ◽  
Vol 66 ◽  
Author(s):  
M. Aslanidou ◽  
P. Smiris

This  study deals with the soil moisture distribution and its effect on the  potential growth and    adaptation of the over-story species in north-east Chalkidiki. These  species are: Quercus    dalechampii Ten, Quercus  conferta Kit, Quercus  pubescens Willd, Castanea  sativa Mill, Fagus    moesiaca Maly-Domin and also Taxus baccata L. in mixed stands  with Fagus moesiaca.    Samples of soil, 1-2 kg per 20cm depth, were taken and the moisture content  of each sample    was measured in order to determine soil moisture distribution and its  contribution to the growth    of the forest species. The most important results are: i) available water  is influenced by the soil    depth. During the summer, at a soil depth of 10 cm a significant  restriction was observed. ii) the    large duration of the dry period in the deep soil layers has less adverse  effect on stands growth than in the case of the soil surface layers, due to the fact that the root system mainly spreads out    at a soil depth of 40 cm iii) in the beginning of the growing season, the  soil moisture content is    greater than 30 % at a soil depth of 60 cm, in beech and mixed beech-yew  stands, is 10-15 % in    the Q. pubescens  stands and it's more than 30 % at a soil depth of 60 cm in Q. dalechampii    stands.


2021 ◽  
Vol 11 (2) ◽  
pp. 492
Author(s):  
Levente Rácz ◽  
Bálint Németh

Exceeding the electric field’s limit value is not allowed in the vicinity of high-voltage power lines because of both legal and safety aspects. The design parameters of the line must be chosen so that such cases do not occur. However, analysis of several operating power lines in Europe found that the electric field strength in many cases exceeds the legally prescribed limit for the general public. To illustrate this issue and its importance, field measurement and finite element simulation results of the low-frequency electric field are presented for an active 400 kV power line. The purpose of this paper is to offer a new, economical expert system based on dynamic line rating (DLR) that utilizes the potential of real-time power line monitoring methods. The article describes the expert system’s strengths and benefits from both technical and financial points of view, highlighting DLR’s potential for application. With our proposed expert system, it is possible to increase a power line’s safety and security by ensuring that the electric field does not exceed its limit value. In this way, the authors demonstrate that DLR has other potential applications in addition to its capacity-increasing effect in the high voltage grid.


2018 ◽  
Vol 644 ◽  
pp. 1036-1043 ◽  
Author(s):  
Zhifeng Yan ◽  
Tiejun Wang ◽  
Lichun Wang ◽  
Xiaofan Yang ◽  
Peyton Smith ◽  
...  

BioResources ◽  
2020 ◽  
Vol 15 (2) ◽  
pp. 2656-2667
Author(s):  
Feihu Chang ◽  
Yanhe Liu ◽  
Bin Zhang ◽  
Wansi Fu ◽  
Pengfei Jiang ◽  
...  

In the process of applying the high-frequency heating technology to bamboo heat treatment, controlling the material temperature has a great influence on the quality of bamboo forming. Therefore, research on the heat transfer mechanism of high-frequency heating of arc-shaped bamboo pieces is of great importance. In this paper, the influence of different moisture content, chord length, and plate voltage on the heating rate of arc-shaped bamboo pieces under high-frequency electric field were studied. The moisture content of bamboo had the most remarkable effect on the heating rate. With increased moisture content, the temperature rose faster. The selection of the plate voltage had an obvious influence on the heating. If the voltage was low, the heating rate was too slow, the heating time was long, or the voltage was high, it was easy to cause electric field breakdown and damage the bamboo pieces. As the chord length decreased, the heating rate gradually increased. When the radian of the arc-shaped bamboo pieces could be ignored, the heating rate was the fastest. The results showed that under certain conditions, the arc-shaped bamboo pieces showed a good heat treatment effect in a high-frequency electric field.


2021 ◽  
Vol 2107 (1) ◽  
pp. 012059
Author(s):  
A A Almaleeh ◽  
A Zakaria ◽  
M H F Rahiman ◽  
Y B Abdul Rahim ◽  
L Munirah ◽  
...  

Abstract Grain storage is an important part of the post-harvest quality assurance process. The moisture level of the grains during storage is one of the primary problems. The current method of measuring rice grain moisture content is based on random sampling, which is relatively localised, and there is no real-time moisture content measurement available. The RF signal was used to build a new technique for detecting moisture and its presence in rice in real-time in this paper. The mapping of an RF signal, in particular, can be transformed into volumetric tomographic images that can be used to forecast moisture distribution.


Soil Research ◽  
1969 ◽  
Vol 7 (2) ◽  
pp. 79 ◽  
Author(s):  
AJ Peck

Air bubbles in soil water affect both hydraulic conductivity and moisture content at a given capillary potential. Consequently changes in the volume of entrapped air, which are not included in the specification of relationships between hydraulic conductivity, moisture content, and capillary potential, will affect all soil-water interactions. Current understanding of the process of air bubble entrapment during infiltration suggests that, in nature, significant air entrapment will often occur. It is shown that infiltrating water can dissolve only a very small volume of air, much less than the amount usually entrapped. Air bubbles in saturated soils are unstable since their pressure must exceed atmospheric, resulting in a diffusive flux of dissolved air from bubbles to menisci contacting the external atmosphere. However, stable bubbles are possible in unsaturated soils. Bubbles which are constrained by pore architecture to non-spherical shapes are usually stable, and spherical bubbles can be stable when the magnitude of the capillary potential exceeds about 3 bars. An approximate analysis of the characteristic time of bubble equilibration indicates that, in an example, it is of order 104 sec, but it may be greater or less by at least a factor 10. Since the equilibration time will be often at least as large as the period of significant soil temperature changes, it cannot be assumed that the entrapped air in a field soil is in an equilibrium state. In such circumstances unstable bubbles may be quasi-permanent. It is suggested that the slow growth of entrapped bubbles may account for the anomalously slow release of water observed in some outflow experiments. Changes of entrapped air volume may also account for the reported dependence of soil-water characteristics on the magnitude of the steps of capillary potential.


Author(s):  
Łukasz Zawadzki ◽  
Marek Bajda

Abstract Soils occurring in the soil “active zone” are in contact with the surface and are directly influenced by external factors (mainly climatic changes) that cause variation in their parameters over time. Dynamic and uncontrolled changes of soil properties e.g. due to rainfall and evapotranspiration processes may affect field test results leading to the misinterpretation of the obtained data. This paper presents investigations on the influence of moisture content changes in sandy soils on CPTU results. For this purpose, a field ground model has been constructed and five CPTU tests with a different moisture content of soil were carried out. During the investigations, the tip resistance (qc), friction on sleeve (fs), and pore water pressure (u2) were measured. Moreover, a TDR probe was applied to determine the distribution of the moisture content in the studied soil columns. Differences between CPT results obtained in saturated and unsaturated soils have been shown. Furthermore, a simple equation to correct the tip resistance value due to the impact of the degree of saturation has been proposed.


Sign in / Sign up

Export Citation Format

Share Document