Design and Analysis of Three-Dimensional Printing of A Porous Titanium Scaffold

Author(s):  
Chunxi Yang ◽  
Jiajie Yang ◽  
Xiaojian Shi ◽  
Meihua Shen ◽  
Kaibing Shi ◽  
...  

Abstract Objective To develop suitable structural designs for the three-dimensional (3-D) printing of a porous titanium scaffold to fill bone defects in knee joints. Pore diameter and mechanic strength are key factors for the 3-D printing of porous titanium scaffolds. Methods Fifteen different pore unit structural models of titanium scaffolds were designed with 3-D printing computer software; five different scaffold shapes were designed: imitation diamond-60°, imitation diamond-90°, imitation diamond-120°, regular tetrahedron and regular hexahedron. Each structural shape was evaluated with three pore diameters 400μm, 600μm and 800μm, and fifteen types of cylindrical models(diameter: 20mm; height: 20mm). Autodesk Inventor software was used determine the strength and safety of the models by simulating simple strength acting on the knee joints. We analyzed the data and found suitable models for 3-D printing of porous titanium scaffolds. Results Fifteen different types of pore unit structural models were evaluated under positive pressure; the compressive strength was lower when the pore diameter(400μm, 600μm and 800μm) was larger, except for the regular tetrahedron structure. Under lateral pressure, the compressive strength was also lower when the pore diameter(400μm, 600μm and 800μm) was larger. Under torsional pressure, the strength of the imitation diamond structure was similar when the pore diameter(400μm, 600μm and 800μm) was larger, and the strengths of the regular tetrahedron and regular hexahedron structures were lower when the pore diameter(400μm, 600μm and 800μm) was larger. In each case, the compressive strength of the regular hexahedron structure was highest, that of the regular tetrahedron was second highest, and that of the imitation diamond structure was relatively low. Fifteen types of cylindrical models under a set force were evaluated, and the sequence of comprehensive compressive strength, from strong to weak was: regular hexahedron> regular tetrahedron> imitation diamond-120°> imitation diamond-90°> imitation diamond-60°. The compressive strength of cylinder models was higher when the pore diameter was smaller. Conclusion The compressive strength differed among titanium scaffolds with different pore structures. The pore diameter and shapes of the pore structure were important factors influencing the compressive strength. The models of regular hexahedron, regular tetrahedron and imitation diamond-120°appeared to meet the conditions of large pore diameters and high compressive strength. The strength of each structure was lower when the pore diameter(400μm, 600μm and 800μm) was larger.

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jiajie Yang ◽  
Yaqiang Li ◽  
Xiaojian Shi ◽  
Meihua Shen ◽  
Kaibing Shi ◽  
...  

Abstract Objective Mechanic strength, pore morphology and size are key factors for the three-dimensional (3D) printing of porous titanium scaffolds, therefore, developing optimal structure for the 3D printed titanium scaffold to fill bone defects in knee joints is instructive and important. Methods Structural models of titanium scaffolds with fifteen different pore unit were designed with 3D printing computer software; five different scaffold shapes were designed: imitation diamond-60°, imitation diamond-90°, imitation diamond-120°, regular tetrahedron and regular hexahedron. Each structural shape was evaluated with three pore sizes (400, 600 and 800 μm), and fifteen types of cylindrical models (size: 20 mm; height: 20 mm). Autodesk Inventor software was used to determine the strength and safety of the models by simulating simple strength acting on the knee joints. We analyzed the data and found suitable models for the design of 3D printing of porous titanium scaffolds. Results Fifteen different types of pore unit structural models were evaluated under positive pressure and lateral pressure; the compressive strength reduced when the pore size increased. Under torsional pressure, the strengths of the imitation diamond structure were similar when the pore size increased, and the strengths of the regular tetrahedron and regular hexahedron structures reduced when the pore size increased. In each case, the compressive strength of the regular hexahedron structure was highest, that of the regular tetrahedron was second highest, and that of the imitation diamond structure was relatively low. Fifteen types of cylindrical models under a set force were evaluated, and the sequence of comprehensive compressive strength, from strong to weak was: regular hexahedron > regular tetrahedron > imitation diamond-120° > imitation diamond-90° > imitation diamond-60°. The compressive strength of cylinder models was higher when the pore size was smaller. Conclusion The pore size and pore morphology were important factors influencing the compressive strength. The strength of each structure reduced when the pore size (400, 600 and 800 μm) increased. The models of regular hexahedron, regular tetrahedron and imitation diamond-120°appeared to meet the conditions of large pore sizes and high compressive strength.


Materials ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3316
Author(s):  
Han Lee ◽  
Jiunn-Der Liao ◽  
Yao-Sheng Guo ◽  
Yung-Der Juang

In repairing or replacing damaged bones, a dual concentric porous titanium scaffold (P-Tix-y) has emerged as a promising bio-mimic design. Herein, various P-Tix-y were made and sintered with relatively dense (x = 10, 20, or 30% porosity) and loose (y = 45, 55, or 65 porosity) structures. Firstly, NaCl was used as the pore-forming additive and followed by a hydrothermal removal method. The compressive strength of the as-formed P-Tix_y and surface morphology, nanomechanical property, and cells’ affinity on the cross-sectioned surface of P-Tix_y (CP-Tix_y) were then characterized. The results demonstrate that the compressive strength of P-Ti10_45, P-Ti20_45, or P-Ti20_55 exhibits a relatively mild decline (e.g., in the range of 181 and 97 MPa, higher than the required value of 70 MPa) and suitable porosities for the intended structure. Nano-hardness on the solid surface of CP-Tix_y shows roughly consistent with that of CP-Ti (i.e., ~8.78 GPa), thus, the porous structure of CP-Tix_y remains mostly unaffected by the addition of NaCl and subsequent sintering process. Most of the surfaces of CP-Tix_y exhibit high fibroblast (L929) cell affinity with low cell mortality. Notably, in the hFOB 1.19 cell adhesion and proliferation test, CP-Ti20_55 and CP-Ti20_65 reveal high cell viability, most probably relating with the assembly of dual porosities with interconnected pores. Overall, the sample P-Ti20_55 provides a relatively load-bearable design with high cell affinity and is thus promising as a three-dimensional bio-scaffold.


Minerals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 213
Author(s):  
Hamid Ait Said ◽  
Hassan Noukrati ◽  
Hicham Ben Youcef ◽  
Ayoub Bayoussef ◽  
Hassane Oudadesse ◽  
...  

Three-dimensional hydroxyapatite-chitosan (HA-CS) composites were formulated via solid-liquid technic and freeze-drying. The prepared composites had an apatitic nature, which was demonstrated by X-ray diffraction and Infrared spectroscopy analyses. The impact of the solid/liquid (S/L) ratio and the content and the molecular weight of the polymer on the composite mechanical strength was investigated. An increase in the S/L ratio from 0.5 to 1 resulted in an increase in the compressive strength for HA-CSL (CS low molecular weight: CSL) from 0.08 ± 0.02 to 1.95 ± 0.39 MPa and from 0.3 ± 0.06 to 2.40 ± 0.51 MPa for the HA-CSM (CS medium molecular weight: CSM). Moreover, the increase in the amount (1 to 5 wt%) and the molecular weight of the polymer increased the mechanical strength of the composite. The highest compressive strength value (up to 2.40 ± 0.51 MPa) was obtained for HA-CSM (5 wt% of CS) formulated at an S/L of 1. The dissolution tests of the HA-CS composites confirmed their cohesion and mechanical stability in an aqueous solution. Both polymer and apatite are assumed to work together, giving the synergism needed to make effective cylindrical composites, and could serve as a promising candidate for bone repair in the orthopedic field.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2619
Author(s):  
Yoshiaki Kataoka ◽  
Ryo Takeda ◽  
Shigeru Tadano ◽  
Tomoya Ishida ◽  
Yuki Saito ◽  
...  

Recently, treadmills equipped with a lower-body positive-pressure (LBPP) device have been developed to provide precise body weight support (BWS) during walking. Since lower limbs are covered in a waist-high chamber of an LBPP treadmill, a conventional motion analysis using an optical method is impossible to evaluate gait kinematics on LBPP. We have developed a wearable-sensor-based three-dimensional motion analysis system, H-Gait. The purpose of the present study was to investigate the effects of BWS by a LBPP treadmill on gait kinematics using an H-Gait system. Twenty-five healthy subjects walked at 2.5 km/h on a LBPP treadmill under the following three conditions: (1) 0%BWS, (2) 25%BWS and (3) 50%BWS conditions. Acceleration and angular velocity from seven wearable sensors were used to analyze lower limb kinematics during walking. BWS significantly decreased peak angles of hip adduction, knee adduction and ankle dorsiflexion. In particular, the peak knee adduction angle at the 50%BWS significantly decreased compared to at the 25%BWS (p = 0.012) or 0%BWS (p < 0.001). The present study showed that H-Gait system can detect the changes in gait kinematics in response to BWS by a LBPP treadmill and provided a useful clinical application of the H-Gait system to walking exercises.


Polymers ◽  
2021 ◽  
Vol 13 (14) ◽  
pp. 2372
Author(s):  
Yesenia Sánchez-Cardona ◽  
Claudia E. Echeverri-Cuartas ◽  
Marta E. Londoño López ◽  
Natalia Moreno-Castellanos

Chitosan scaffolds based on blending polymers are a common strategy used in tissue engineering. The objective of this study was evaluation the properties of scaffolds based on a ternary blend of chitosan (Chi), gelatin (Ge), and polyvinyl alcohol (PVA) (Chi/Ge/PVA), which were prepared by cycles of freeze-thawing and freeze-drying. It then was used for three-dimensional BRIN-BD11 beta-cells culturing. Weight ratios of Chi/Ge/PVA (1:1:1, 2:2:1, 2:3:1, and 3:2:1) were proposed and porosity, pore size, degradation, swelling rate, compressive strength, and cell viability analyzed. All ternary blend scaffolds structures are highly porous (with a porosity higher than 80%) and interconnected. The pore size distribution varied from 0.6 to 265 μm. Ternary blends scaffolds had controllable degradation rates compared to binary blend scaffolds, and an improved swelling capacity of the samples with increasing chitosan concentration was found. An increase in Young’s modulus and compressive strength was observed with increasing gelatin concentration. The highest compressive strength reached 101.6 Pa. The MTT assay showed that the ternary blends scaffolds P3 and P4 supported cell viability better than the binary blend scaffold. Therefore, these results illustrated that ternary blends scaffolds P3 and P4 could provide a better environment for BRIN-BD11 cell proliferation.


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0004
Author(s):  
Brittany Hedrick ◽  
Anthony Riccio ◽  
Danielle M. Thomas ◽  
Claire Shivers ◽  
Matthew Siebert ◽  
...  

Category: Hindfoot; Other Introduction/Purpose: While lengthening of the lateral column through a calcaneal neck osteotomy is an integral component of flatfoot reconstruction in younger patients with flexible planovalgus deformities, concern exists as to the effect of this intra- articular osteotomy on subtalar motion. The purpose of this study is to quantify the alterations in subtalar motion following lateral column lengthening (LCL). Methods: The subtalar motion of 14 fresh frozen cadaveric feet was assessed using a three-dimensional motion capture system and materials testing system (MTS). Following potting of the tibia and calcaneus, optic markers were placed into the tibia, calcaneus and talus. The MTS was used to apply a rotational force across the subtalar joint to a torque of 5Nm. Abduction/adduction, supination/pronation, and plantarflexion/dorsiflexion about the talus was recorded. Specimens then underwent LCL via a calcaneal neck osteotomy which was maintained with a 12mm porous titanium wedge. Repeat subtalar motion analysis was performed and compared to pre-LCL motion using a paired t-test. Results:: No statistically significant differences in subtalar abduction/adduction (10.9O vs. 11.8O degrees, p=.48), supination/pronation (3.5O vs. 2.7O, p=.31), or plantarflexion/dorsiflexion (1.6O vs 1.0O, p=.10) were identified following LCL. Conclusion:: No significant changes in subtalar motion were observed following lateral column lengthening in this biomechanical cadaveric study. While these findings do not obviate concerns of clinical subtalar stiffness following planovalgus deformity correction, they suggest that diminished postoperative subtalar motion may be due to soft tissue scarring rather than alterations of joint anatomy.


2007 ◽  
Vol 330-332 ◽  
pp. 1177-1180 ◽  
Author(s):  
Kanji Tsuru ◽  
Satoshi Hayakawa ◽  
Yuki Shirosaki ◽  
T. Okayama ◽  
K. Kataoka ◽  
...  

Porous & rubbery organic-inorganic hybrids were synthesized from tetraethoxysilane (TEOS) and polydimethylsiloxane (PDMS) through a sol-gel route using sieved sucrose granules as a porogen. The porous hybrids with a high content of PDMS behaved like polymer sponge. The porosity was over 90% irrespective of the hybrid composition and the pore diameter ranged from 100 to 500 μm. In the three-dimensional cell culture, mammalian cells were well cultured in the porous hybrids. The present results indicate that the hybrids may be a promising scaffold for developing such functional culture methods.