scholarly journals Systematic Evaluating and Modeling of SARS-CoV-2 UVC Disinfection

Author(s):  
Sebastian Freeman ◽  
Karen Kibrler ◽  
Zachary Lipsky ◽  
Sha Jin ◽  
Guy German ◽  
...  

Abstract The ongoing COVID-19 global pandemic has necessitated evaluating various disinfection technologies for reducing viral transmission in public settings. Ultraviolet (UV) radiation can inactivate pathogens and viruses but more insight is needed into the performance of different UV wavelengths and their applications. We observed greater than a 3-log reduction of SARS-CoV-2 infectivity with a dose of 12.5 mJ/cm2 of 254 nm UV light when the viruses were suspended in PBS, while a dose of 25 mJ/cm2 was necessary to achieve a similar reduction when they were in an EMEM culture medium containing 2%(v/v) FBS, highlighting the critical effect of media in which the virus is suspended, given that SARS-CoV-2 is always aerosolized when airborne or deposited on a surface. It was found that SARS-CoV-2 susceptibility (a measure of the effectiveness of the UV light) in a buffer such as PBS was 4.4-fold greater than that in a cell culture medium. Furthermore, we discovered the attenuation of UVC disinfection by amino acids, vitamins, and niacinamide, highlighting the importance of determining UVC dosages under a condition close to aerosols that wrap the viruses. We developed a disinfection model to determine the effect of the environment on UVC effectiveness with three different wavelengths, 222 nm, 254 nm, and 265 nm. An inverse correlation between the liquid absorbance and the viral susceptibility was observed. We found that 222 nm light was most effective at reducing viral infectivity in low absorbing liquids such as PBS, whereas 265 nm light was most effective in high absorbing liquids such as cell culture medium. Viral susceptibility was further decreased in N95 masks with 222 nm light being the most effective. The safety of 222 nm was also studied. We detected changes to the mechanical properties of the stratum corneum of human skins when the 222 nm accumulative exposure exceeded 50 J/cm2.The findings highlight the need to evaluate each UV for a given application, as well as limiting the dose to the lowest dose necessary to avoid unnecessary exposure to the public.

2020 ◽  
Vol 56 (89) ◽  
pp. 13792-13795
Author(s):  
Phillip R. A. Chivers ◽  
Rebecca S. Dookie ◽  
Julie E. Gough ◽  
Simon J. Webb

Anthracene-amino acids self-assemble into supramolecular hydrogels upon the addition of salts in water or cell culture medium; subsequent exposure to 365 nm UV light disassembles the hydrogel by photodimerising the gelators.


2020 ◽  
Author(s):  
Federica Saponaro ◽  
Marco Borsò ◽  
Sara Verlotta ◽  
Lavinia Bandini ◽  
Alessandro Saba ◽  
...  

2013 ◽  
Vol 133 (5) ◽  
pp. 278-285
Author(s):  
Norimitsu Takamura ◽  
Douyan Wang ◽  
Takao Satoh ◽  
Takao Namihira ◽  
Hisato Saitoh ◽  
...  

2021 ◽  
Vol 12 ◽  
pp. 204173142110086
Author(s):  
Jun Yong Kim ◽  
Won-Kyu Rhim ◽  
Yong-In Yoo ◽  
Da-Seul Kim ◽  
Kyoung-Won Ko ◽  
...  

Exosomes derived from mesenchymal stem cells (MSCs) have been studied as vital components of regenerative medicine. Typically, various isolation methods of exosomes from cell culture medium have been developed to increase the isolation yield of exosomes. Moreover, the exosome-depletion process of serum has been considered to result in clinically active and highly purified exosomes from the cell culture medium. Our aim was to compare isolation methods, ultracentrifuge (UC)-based conventional method, and tangential flow filtration (TFF) system-based method for separation with high yield, and the bioactivity of the exosome according to the purity of MSC-derived exosome was determined by the ratio of Fetal bovine serum (FBS)-derived exosome to MSC-derived exosome depending on exosome depletion processes of FBS. The TFF-based isolation yield of exosome derived from human umbilical cord MSC (UCMSC) increased two orders (92.5 times) compared to UC-based isolation method. Moreover, by optimizing the process of depleting FBS-derived exosome, the purity of UCMSC-derived exosome, evaluated using the expression level of MSC exosome surface marker (CD73), was about 15.6 times enhanced and the concentration of low-density lipoprotein-cholesterol (LDL-c), known as impurities resulting from FBS, proved to be negligibly detected. The wound healing and angiogenic effects of highly purified UCMSC-derived exosomes were improved about 23.1% and 71.4%, respectively, with human coronary artery endothelial cells (HCAEC). It suggests that the defined MSC exosome with high yield and purity could increase regenerative activity.


1995 ◽  
Vol 13 (4) ◽  
pp. 389-392 ◽  
Author(s):  
Michael Zang ◽  
Helmut Trautmann ◽  
Christine Gandor ◽  
Ferruccio Messi ◽  
Fred Asselbergs ◽  
...  

2014 ◽  
Vol 119 ◽  
pp. 96-99 ◽  
Author(s):  
Furqan A. Shah ◽  
Delia S. Brauer ◽  
Nikita Desai ◽  
Robert G. Hill ◽  
Karin A. Hing

Sign in / Sign up

Export Citation Format

Share Document