Ceramic microfiltration; a novel and compact process for the treatment of surface water

2018 ◽  
Vol 18 (6) ◽  
pp. 2035-2043 ◽  
Author(s):  
C. Rockey ◽  
D. C. Metcalfe ◽  
G. Galjaard ◽  
H. Shorney-Darby ◽  
J. Zheng

Abstract In-line coagulation adsorption (ILCA) followed by ceramic microfiltration (CMF) was tested at pilot scale and compared to a full scale traditional process consisting of coagulation and dissolved air flotation (DAF) followed by rapid gravity sand filtration (RGF), for treating a reservoir water source which is prone to high concentrations of algae. The ILCA CMF process was shown to remove 10–16% more dissolved organic carbon (DOC) and reduced disinfection by-product formation potential (DBPFP) by 9–13% in comparison to conventional treatment (optimised coagulation). ILCA effectively controlled membrane fouling allowing the ceramic membranes to be operated at high flux (200 l/m2h) with low membrane fouling (0.9–1.9 kPa/day). A process comprising ILCA and direct ceramic microfiltration was shown to provide very stable treated water quality under a range of challenging conditions. Additionally, the process is more compact showing significant reductions (circa 60%) in footprint relative to a conventional DAF/RGF process.

1998 ◽  
Vol 37 (2) ◽  
pp. 35-42 ◽  
Author(s):  
M. J. Bauer ◽  
R. Bayley ◽  
M. J. Chipps ◽  
A. Eades ◽  
R. J. Scriven ◽  
...  

Thames Water treats approximately 2800Ml/d of water originating mainly from the lowland rivers Thames and Lee for supply to over 7.3million customers, principally in the cities of London and Oxford. This paper reviews aspects of Thames Water's research, design and operating experiences of treating algal rich reservoir stored lowland water. Areas covered include experiences of optimising reservoir management, uprating and upgrading of rapid gravity filtration (RGF), standard co-current dissolved air flotation (DAF) and counter-current dissolved air flotation/filtration (COCO-DAFF®) to counter operational problems caused by seasonal blooms of filter blocking algae such as Melosira spp., Aphanizomenon spp. and Anabaena spp. A major programme of uprating and modernisation (inclusion of Advanced Water Treatment: GAC and ozone) of the major works is in progress which, together with the Thames Tunnel Ring Main, will meet London's water supply needs into the 21st Century.


2018 ◽  
Vol 19 (3) ◽  
pp. 823-830 ◽  
Author(s):  
Yonglei Wang ◽  
Wenhao Wang ◽  
Ruibao Jia ◽  
Mei Li ◽  
Baozhen Liu ◽  
...  

Abstract As the water diversion reservoir showed high organic matter and high algae in summer, the potassium permanganate pre-oxidation/dissolved air flotation/carbon sand double filter process was developed. The test results show that the optimum operation conditions of the combined process were as follows: the dosage of KMnO4 was 0.3 mg/L, the dosage of polymeric aluminum ferric chloride (PAFC) was 3.0 mg/L (Al3+), the reflux ratio was 10%, and the dissolved gas pressure was 0.3 Mpa. Taking Ji'nan Queshan reservoir water algae pollution as the research object, the average removal rate of chlorophyll a, blue-green algae, turbidity, particle number and total organic carbon (TOC) reached 66.64%, 95.44%, 94.45%, 99.34% and 46.68%, respectively; the methylisoborneol (MIB) removal rate was 92.47%, the odor level decreased with process flow from raw water level 4 to effluent level 1.5, geosmin (GSM) dropped below the detection limit, and the total removal rate of trihalomethane formation potential (THMFP) was 33.56%. The effluent of the combined process meets the requirements of the Hygienic Standard for Drinking Water (GB5749-2006) after it is disinfected.


2001 ◽  
Vol 43 (8) ◽  
pp. 43-49 ◽  
Author(s):  
M. A. P. Raeli ◽  
M. Marchetto

This paper presents the results of an experimental investigation about the performance of a horizontal flow high-rate pilot scale Dissolved Air Flotation (HRDAF) unit containing inclined parallel plates for treating a coloured and low turbidity raw water. Experiments were performed with the DAF unit in order to verify the influence on flotation of : (i) the water velocity (Vh) between the plates, in the range 18 to 96.5 cm.min−1 with corresponding Reynolds numbers between 240 and 1060; (ii) the supplied air (S*) value ranging from 2.2 to 8.5 g of air/m3 of water ; (iii) the angle of the plates (60° or 70°). The best pilot plant operational condition was obtained applying only 4.0 g/m3 (S*) with Vh around 18 cm.min−1 for treatment of water coagulated with a Al2(SO4)3 dosage of 40 mg.l−1. In these conditions, the unit presented very good removal efficiencies of colour (90%, residual of 10 uC), turbidity (88%, residual of 0.8 NTU ) and TSS (94%, residual of 1.8 mg.l−1). Furthermore, the unit could operate at higher Vh values up to 76 cm.min−1 and still present good results. The DAF unit thus behaved as a high rate unit presenting good performance with low air requirement.


1999 ◽  
Vol 40 (8) ◽  
pp. 137-143 ◽  
Author(s):  
R. G. Penetra ◽  
M. A. P. Reali ◽  
E. Foresti ◽  
J. R. Campos

This paper presents the results of a study performed with a lab-scale dissolved-air flotation (LSDAF) unit fed with previously coagulated effluent from a pilot scale up-flow anerobic sludge blanket (UASB) reactor treating domestic sewage. Physical operational conditions for coagulation (rapid mix) and flocculation/flotation were maintained constant. Chemical (FeCl3) dosages ranged from 30 to 110 mg.l−1. The effect of pH was also verified in the range of 5.1 to 7.6 for each dosage. Best results were achieved for 65 mg.l−1 of FeCl3 and pH values between 5.3 and 6.1. For these conditions, the removal efficiencies obtained in the LSDAF unit were: between 87% and 91% for chemical oxygen demand (COD), between 95% and 96% for total phosphate (TP), 94% for total suspended solids (TSS), between 96% and 97% for turbidity (TU), between 90% and 93% for apparent color (AC) and more than 96% for sulfide (S). For the UASB-DAF system, global efficiencies would be around 98% for COD, 98% for TP, 98.4% for TSS, 99.3% for TU and 98% for AC. The stripped gases treatment is desirable.


1997 ◽  
Vol 36 (4) ◽  
pp. 177-189 ◽  
Author(s):  
A. Vlaški ◽  
A. N. van Breemen ◽  
G. J. Alaerts

Conventional (sedimentation) and advanced (dissolved air flotation) treatment were studied in the context of removal of the single cells form of the cyanobacteria Microcystis aeruginosa. This cyanobacterium species is recognised as an ideal surrogate for process removal efficiency assessment of particles of the problematic size range (3-10 m). The agglomeration (coagulation/flocculation) phase has been indicated as essential and determining the down-stream process efficiency, hence it is a prerequisite for process improvement. Relevant process parameters have been addressed on a laboratory (model water) and pilot plant (reservoir water) scale, including the influence of coagulant (FeCl3) dose, coagulation pH, flocculation time, energy input (G value), single stage versus tapered flocculation and application of cationic polymer as coagulant aid. The process efficiency was assessed as a function of the preceeding agglomeration (coagulation/flocculation) phase and the obtained particle (floc) size distributions. The particle (floc) size - density relationship was addressed in the context of more accurate process kinetic modelling.


2000 ◽  
Vol 41 (8) ◽  
pp. 137-144 ◽  
Author(s):  
H. G. Snyman ◽  
P. Forssman ◽  
A. Kafaar ◽  
M. Smollen

Sewage sludge is typically dewatered using drying beds, belt filter presses or centrifuges. Mechanical dewatering of sludge is costly in terms of capital and running costs, especially the flocculent. In an attempt to address the need for more cost-effective dewatering technologies, electro-osmotic belt filtering was developed by Smollen and Kafaar in 1995. Themechanical equipment resembles a belt filter press but the belts are stainless steel, woven belts, which act as the electrodes. In this study, thefeasibility of the technology was tested at pilot scale using wasteactivated-, anaerobically digested- and dissolved air flotation sludge. The parameters which were investigated includes the applied voltage, polyelectrolyteusage and sludge feed rate. Applied voltage of between 15 and 25 volts increased the dewatering significantly in the waste activated- and anaerobically digested sludge. Applying a voltage in dissolved air flotation sludge could not enhance the efficiency of dewatering, unless stored to de-air. The technology was found as sensitive to polyelectrolyte dosages as belt presses. The performance of the electro-osmotic belt filter was sensitive to feed rate, but performed well with non-thickened waste activated sludge (0.61% solids), resulting in cake solids above 20%.


2020 ◽  
Vol 6 (4) ◽  
pp. 935-944 ◽  
Author(s):  
Bhaskar Jyoti Deka ◽  
Jiaxin Guo ◽  
Sanghyun Jeong ◽  
Manish Kumar ◽  
Alicia Kyoungjin An

High AOM removal achieved by pre-oxidation with coagulation–flocculation-dissolved air flotation. In situ ferrate was formed by wet chemical oxidation of NaOCl-Fe3+. Membrane fouling was significantly alleviated and assessed by OCT technique.


Water ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 2804
Author(s):  
Dong-Ho Kim ◽  
Changkyoo Choi ◽  
Chulmin Lee ◽  
Rusnang Syamsul Adha ◽  
Thanh-Tin Nguyen ◽  
...  

Roughing filters are types of porous media filter used in pretreatment systems where the raw water contains a large amount of suspended particles (SPs) and organic matter. Mesh tube filtration (MTF) media are roughing-filter media composed of low-density polyethylene used for SP removal during wastewater treatment. In this study, we present an improved MTF design—a porous filter bed (PFB), which exhibits superior SP removal performance compared to conventional MTF media. We then compare the applicability of MTF and PFB to both the primary pretreatment process for seawater desalination and the water reuse process. In bench-scale SP removal experiments, PFB shows removal rates of 46.7%, 68.0%, 67.6%, and 68.4% at hydraulic retention times of 15, 20, 30, and 60 min, respectively, which are better than those of MTF. The specific energy consumption (SEC) of batch dissolved air flotation (DAF) was known to range from 0.035 to 0.047 kWh/m3, whereas the SEC calculated for pilot-scale MTF and PFB is 0.027 kWh/m3 and minimum energy for influent supply, respectively. This suggests that PFB can compete with DAF as a primary pretreatment process. MTF predominantly removes SPs by sedimentation, whereas SP removal in PFB typically occurs via deposition of SPs on the mesh tube media.


Sign in / Sign up

Export Citation Format

Share Document