An Innovative Technology for Upgrading Nutrient Removal Activated Sludge Plants

1990 ◽  
Vol 22 (7-8) ◽  
pp. 9-20 ◽  
Author(s):  
Jiří Wanner ◽  
Miroslav Kos ◽  
Petr Grau

A brief survey of activated sludge systems for nutrient removal from wastewaters iss given and their characteristic features are discussed. Four modifications of the nutrient removal activated sludge process were tested in pilot-plant units with a wastewater from the town of Pilsen. The re-aeration of the returned sludge proved to be advantageous for achieving high nitrogen removal. For the design of a new wastewater treatment plant for the town of Pilsen, the activated sludge process, consisting of the anaerobic-anoxic-oxic sequence with the reaeration of the returned sludge, was used. The newly designed technological line of the so-called R-AN-D-N Process is very flexible thanks to the wastewater inlet in both the anaerobic and the anoxic zone and to the possibility of introducing the internal recycle in either the anoxic or the anaerobic zone.

2013 ◽  
Vol 8 (1) ◽  
pp. 16-22

In this study two bench scale activated sludge systems were used, a CSTR and an SBR for the treatment of coke – oven wastewater. Both reactors were inoculated with activated sludge from a municipal wastewater treatment plant. At the first stages of operation, reactors were feed by a mixture of municipal wastewater and synthetic wastewater. Full acclimatization of the microorganisms to synthetic wastewater was achieved in 60 days. The operation of the reactors was divided into three distinct periods. The first period was characterized by the treatment of high organic but non-toxic synthetic wastewater. During this period COD and BOD5 removal efficiencies reached 95 and 98% respectively, in both reactors. Nutrient removal was better in the SBR reactor rather than in the CSTR. In the second period phenol was added in concentrations up to 300 mg l-1. Degradation of phenol started about the 20th day after its introduction to the reactors. In this period no effects of phenol to nutrient removal were observed, whereas the removal efficiency of organic matter in both reactors was slightly decreased. During the third period phenol concentrations of the influent were gradually increased to 1000 mg l-1, while cyanide and thiocyanite were added to the influent composition to concentrations reaching concentrations of 20 and 250 mg l-1 respectively. The composition of the influent of this period was a full assimilation of coke oven wastewater. Introduction of increased phenol concentrations along with cyanide compounds initiated irreversible effects on the activated sludge microfauna of the CSTR causing inherent problems to the treatment process, while SBR showed greater capacity to withstand and degrade toxic compounds. The beginning of this period was characterized by decreased settleability of the suspended solids as well as decrease of organic matter and nutrient removal efficiencies. Monitoring of the effluent characteristics during this period reported over 90% for organic load, 85% of nutrient removal and over 90% of phenol and cyanide removal in SBR, while the removal efficiencies for the CSTR were 75, 65 and 80% respectively.


Author(s):  
Asaad Seraj Aburzizah, Fahad Salih Aljohani

Wastewater may be described as water that was used to convey pollutants away from a source of pollution. It originates in homes, businesses, schools, hospitals, prisons, and industries, and was ultimately discharged back into the environment. Solids are present in nearly every wastewater, may be very detrimental environmentally, and so are very often regulated in discharges of wastewater. The aimed of this study was to intend the usage of the Activated Sludge Process Control and operating the activated sludge process, including nutrient removal, and troubleshooting. This study was contacted with Saudi Arabia waste water plants as guideline for maintenance and troubleshoots. When troubleshooting activated sludge problems, was to overlook obvious sources and solutions in favor of the strange and unusual.  


2016 ◽  
Vol 9 (2) ◽  
Author(s):  
Dinda Rita K. Hartaja ◽  
Imam Setiadi

Generally, wastewater of nata de coco industry contains suspended solids and COD were high, ranging from 90,000 mg / l. The high level of of the wastewater pollutants, resulting in nata de coco industry can not be directly disposed of its wastewater into the environment agency. Appropriate technology required in order to process the waste water so that the treated water can meet the environmental quality standards that are allowed. Designing the waste water treatment plant that is suitable and efficient for treating industrial wastewater nata de coco is the activated sludge process. Wastewater treatment using activated sludge process of conventional (standard) generally consists of initial sedimentation, aeration and final sedimentation.Keywords : Activated Sludge, Design, IPAL


2008 ◽  
Vol 3 (1) ◽  
Author(s):  
Young H. Yoon ◽  
Jae R. Park ◽  
Sang W. Ahn ◽  
Kwang B. Ko ◽  
Kyung J. Min ◽  
...  

Hybrid Activated Sludge Process (HASP) with IMET was developed and applied to an activated sludge process for the advanced nutrient treatment in Korea. The characteristics of nitrogen removal from the HASP were investigated through a kinetic study by batch-type experiment. Online DB analysis produced from the IMET was conducted for the nutrient removal performance in the field demonstration plant treating 10,000 m3/day in G city of Korea. In this paper, we aimed to determine the effect of increasing NHM4+-N load on the specific nitrification rate (SNR) and the specific denitrification rate (SDNR) through a batch-type experiment, and to estimate the net reaction time for the phase-transfer rate using online DB analysis in the HASP operation. Experimental results include: (1) both the nitrification and denitrification followed first-order kinetics; (2) the maximum SNR and SDNR were 4.0301 mgN/gVSS·hr and 2.785 mgN/gVSS·hr, respectively; (3) comparison of reaction rates between nitrification and denitrification from the non-linear regression analysis found that nitrification rate was higher than denitrification.


1987 ◽  
Vol 22 (3) ◽  
pp. 437-443 ◽  
Author(s):  
N. Kosaric ◽  
Z. Duvnjak

Abstract Aerobic sludge from a municipal activated sludge treatment plant, sludge from a conventional municipal anaerobic digester, aerobic sludge from an activated sludge process of a petroleum refinery, and granular sludge from an upflow sludge blanket reactor (USBR) were tested in the deemulsification of a water-in-oil emulsion. All sludges except the last one, showed a good deemulsification capability and could he used for a partial deemulsification of such emulsions. The rate and degree of the deemulsifications increased with an increase in sludge concentrations. The deemulsifications were faster at 85°C and required smaller amounts of sludge than in the case of the deemulsifications at room temperature. An extended stirring (up to a certain limit) in the course of the dispersion of sludge emulsion helped the deemulsification. Too vigorous agitation had an adverse effect. The deemulsification effect of sludge became less visible with an increase in the dilution of emulsion which caused an increase in its spontaneous deemulsification.


1990 ◽  
Vol 22 (7-8) ◽  
pp. 131-138
Author(s):  
Ahmed Fadel

Many of Egypt's cities have existing treatment plants under operation that have been constructed before 1970. Almost all of these treatment plants now need rehabilitation and upgrading to extend their services for a longer period. One of these plants is the Beni Suef City Wastewater Treatment Plant. The Beni Suef WWTP was constructed in 1956. It has primary treatment followed by secondary treatment employing intermediate rate trickling filters. The BOD, COD, and SS concentration levels are relatively high. They are approximately 800, 1100, and 600 mg/litre, respectively. The Beni Suef city required the determination of the level of work needed for the rehabilitation and upgrading of the existing 200 l/s plant and to extend its capacity to 440 l/s at year 2000 A description of the existing units, their deficiencies and operation problems, and the required rehabilitation are presented and discussed in this paper. Major problems facing the upgrading were the lack of space for expansion and the shortage of funds. It was, therefore, necessary to study several alternative solutions and methods of treatment. The choice of alternatives was from one of the following schemes: a) changing the filter medium, its mode of operation and increasing the number of units, b) changing the trickling filter to high rate and combining it with the activated sludge process, for operation by one of several possible combinations such as: trickling filter-solids contact, roughing filter-activated sludge, and trickling filter-activated sludge process, c) dividing the flow into two parts, the first part to be treated using the existing system and the second part to be treated by activated sludge process, and d) expanding the existing system by increasing the numbers of the different process units. The selection of the alternative was based on technical, operational and economic evaluations. The different alternatives were compared on the basis of system costs, shock load handling, treatment plant operation and predicted effluent quality. The flow schemes for the alternatives are presented. The methodology of selecting the best alternative is discussed. From the study it was concluded that the first alternative is the most reliable from the point of view of costs, handling shock load, and operation.


1988 ◽  
Vol 20 (11-12) ◽  
pp. 131-136 ◽  
Author(s):  
A. D. Wong ◽  
C. D. Goldsmith

The effect of discharging specific oil degrading bacteria from a chemostat to a refinery activated sludge process was determined biokinetically. Plant data for the kinetic evaluation of the waste treatment plant was collected before and during treatment. During treatment, the 500 gallon chemostatic growth chamber was operated on an eight hour hydraulic retention time, at a neutral pH, and was fed a mixture of refinery wastewater and simple sugars. The biokinetic constants k (days−1), Ks (mg/L), and K (L/mg-day) were determined before and after treatment by Monod and Lineweaver-Burk plots. Solids discharged and effluent organic concentrations were also evaluated against the mean cell retention time (MCRT). The maximum utilization rate, k, was found to increase from 0.47 to 0.95 days−1 during the operation of the chemostat. Subsequently, Ks increased from 141 to 556 mg/L. Effluent solids were shown to increase slightly with treatment. However, this was acceptable due to the polishing pond and the benefit of increased ability to accept shock loads of oily wastewater. The reason for the increased suspended solids in the effluent was most likely due to the continual addition of bacteria in exponential growth that were capable of responding to excess substrate. The effect of the chemostatic addition of specific microbial inocula to the refinery waste treatment plant has been to improve the overall organic removal capacity along with subsequent gains in plant stability.


1989 ◽  
Vol 21 (10-11) ◽  
pp. 1161-1172 ◽  
Author(s):  
M. Hiraoka ◽  
K. Tsumura

The authors have been developing a hierarchical control system for the activated sludge process which consists of an upper level system controlling long-term seasonal variations, a control system of intermediate level aiming at optimization of the process and a control system of lower level controlling diurnal changes or hourly fluctuations. The control system using the multi-variable statistical model is one of the most appropriate control systems based on the modern control theory, for applying the lower level control of the activated sludge process. This paper introduces our efforts for developing the reliable data acquisition system, the control experiments applying the AR-model, one of the statistical models which were conducted at a pilot plant and present studies on the system identification and control at a field sewage treatment plant.


1994 ◽  
Vol 30 (6) ◽  
pp. 31-40 ◽  
Author(s):  
Hiroyshi Emori ◽  
Hiroki Nakamura ◽  
Tatsuo Sumino ◽  
Tadashi Takeshima ◽  
Katsuzo Motegi ◽  
...  

For the sewage treatment plants near rivers and closed water bodies in urbanized areas in Japan and European countries, there is a growing demand for introduction of advanced treatment processes for nitrogen and phosphorus from the viewpoints of water quality conservation and environmental protection. In order to remove nitrogen by the conventional biological treatment techniques, it is necessary to make a substantial expansion of the facility as compared with the conventional activated sludge process. In such urbanized districts, it is difficult to secure a site and much capital is required to expand the existing treatment plant. To solve these problems, a compact single sludge pre-denitrification process using immobilized nitrifiers was developed. Dosing the pellets, which are suitable for nitrifiers growth and physically durable, into the nitrification tank of single sludge pre-denitrification process made it possible to perform simultaneous removal of BOD and nitrogen in a retention time equal to that in the conventional activated sludge process even at the low water temperature of about 10 °C. The 3,000 m3/d full-scale conventional activated sludge plant was retrofitted and has been successfully operated.


1993 ◽  
Vol 28 (10) ◽  
pp. 309-316
Author(s):  
Bilsen Beler Baykal

Small activated sludge systems operate in transient states under intermittent and variable flows. Simulations for such a treatment plant in a summer house site operating on a seasonal basis is investigated for system performance and viability using the five component inert soluble substrate generation model. The results have revealed that the viability drops to zero within the first month after the cessation of the feed for intermittently loaded systems that are fed during the summer months, while it never reaches that value for systems operating all year round with reduced flows off season. Restartup is compulsory for the intermittent loadings while the system adapts itself in a stepwise manner for the year round operation. Other factors being comparable, conventional operation with shorter sludge ages may be preferable since viability of the sludge is higher and the effluent COD is comparable.


Sign in / Sign up

Export Citation Format

Share Document