scholarly journals Effect of joint stiffness and flexibility on the design of reinforced cement concrete structure

Author(s):  
Govind Prasad Lamichhane ◽  
Prajwal Giri

Relevance. A beam-column joint is a crucial zone in any frame structure that transmits the forces at the end of the members in the panel zone. The connection between the joints may be assumed as rigid or flexible one and it is not an ideal one to predict the actual behavior of the joint section. Methods. The displacement along the joint section is the most critical one that has to be taken care while designing the structure. In this paper, the flexibility of the reinforced concrete joints was studied under two different cases: in first phase, building having 3 storey including ground floor was taken and is analysed using SAP 2000 and secondly third floor shear wall with l hollow concrete mesh of column section was analyzed in same software and the flexibility of the joints was tested in terms of its stress and displacement parameters using different approaches such as link mass property, end length offset zone, panel zone rotational spring stiffness property. The results obtained from the two cases were analyzed with consideration of parametric study and variation of the stresses with displacement and are shown with comparative graphic.

2018 ◽  
Vol 763 ◽  
pp. 259-269
Author(s):  
George Webb ◽  
Kanyakon Kosinanonth ◽  
Tushar Chaudhari ◽  
Saeid Alizadeh ◽  
Gregory A. MacRae

Beam column joint subassemblies in steel moment frames often have simply-supported gravity beams framing into the joint in the perpendicular direction. When these subassemblies undergo lateral displacement, moments enter the column from the beams. Some of these moments are directly applied from the in-plane beam and slab stresses as they contact the column, and additional moments occur as the slab causes the perpendicular simply supported beams to twist. In most design codes around the world, no explicit consideration of these moments is performed even though they may increase the likelihood of column yielding and a soft-storey mechanism. This paper quantifies the magnitude of these perpendicular beam twisting moments in typical subassemblies using inelastic finite element analysis. It is shown that for beam-column-joint-slab subassemblies where the primary and secondary beams are fully welded to the column, the addition of slab effects significantly increases the total stiffness and strength of the composite frame structure. In addition to this, it is also shown the twisting moment demand of the secondary beams increased the frames strength by approximately 2% for an imposed drift of 5% for the subassembly investigated when no gap was provided between slab and the column. It was also shown the twisting moment demand of the secondary beams increased the frames strength by approximately 10% for a maximum imposed drift of 5% for the subassembly investigated when a gap was provided between the slab and the column.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Suresh Kumar Arunachalam ◽  
Muthukannan Muthiah ◽  
Kanniga Devi Rangaswamy ◽  
Arunkumar Kadarkarai ◽  
Chithambar Ganesh Arunasankar

Purpose Demand for Geopolymer concrete (GPC) has increased recently because of its many benefits, including being environmentally sustainable, extremely tolerant to high temperature and chemical attacks in more dangerous environments. Like standard concrete, GPC also has low tensile strength and deformation capacity. This paper aims to analyse the utilization of incinerated bio-medical waste ash (IBWA) combined with ground granulated blast furnace slag (GGBS) in reinforced GPC beams and columns. Medical waste was produced in the health-care industry, specifically in hospitals and diagnostic laboratories. GGBS is a form of industrial waste generated by steel factories. The best option to address global warming is to reduce the consumption of Portland cement production and promote other types of cement that were not a pollutant to the environment. Therefore, the replacement in ordinary Portland cement construction with GPC is a promising way of reducing carbon dioxide emissions. GPC was produced due to an alkali-activated polymeric reaction between alumina-silicate source materials and unreacted aggregates and other materials. Industrial pollutants such as fly ash and slag were used as raw materials. Design/methodology/approach Laboratory experiments were performed on three different proportions (reinforced cement concrete [RCC], 100% GGBS as an aluminosilicate source material in reinforced geopolymer concrete [GRGPC] and 30% replacement of IBWA as an aluminosilicate source material for GGBS in reinforced geopolymer concrete [IGRGPC]). The cubes and cylinders for these proportions were tested to find their compressive strength and split tensile strength. In addition, beams (deflection factor, ductility factor, flexural strength, degradation of stiffness and toughness index) and columns (load-carrying ability, stress-strain behaviour and load-deflection behaviours) of reinforced geopolymer concrete (RGPC) were studied. Findings As shown by the results, compared to Reinforced Cement Concrete (RCC) and 100% GGBS based Reinforced Geopolymer Concrete (GRGPC), 30% IBWA and 70% GGBS based Reinforced Geopolymer Concrete (IGRGPC) (30% IBWA–70% GGBS reinforced geo-polymer concrete) cubes, cylinders, beams and columns exhibit high compressive strength, tensile strength, flexural strength, load-carrying ability, ultimate strength, stiffness, ductility and deformation capacity. Originality/value All the results were based on the experiments done in this research. All the result values obtained in this research are higher than the theoretical values.


2018 ◽  
Vol 8 (10) ◽  
pp. 1871 ◽  
Author(s):  
Xueyuan Yan ◽  
Suguo Wang ◽  
Canling Huang ◽  
Ai Qi ◽  
Chao Hong

Precast monolithic structures are increasingly applied in construction. Such a structure has a performance somewhere between that of a pure precast structure and that of a cast-in-place structure. A precast concrete frame structure is one of the most common prefabricated structural systems. The post-pouring joint is important for controlling the seismic performance of the entire precast monolithic frame structure. This paper investigated the joints of a precast prestressed concrete frame structure. A reversed cyclic loading test was carried out on two precast prestressed concrete beam–column joints that were fabricated with two different concrete strengths in the keyway area. This testing was also performed on a cast-in-place reinforced concrete joint for comparison. The phenomena such as joint crack development, yielding, and ultimate damage were observed, and the seismic performance of the proposed precast prestressed concrete joint was determined. The results showed that the precast prestressed concrete joint and the cast-in-place joint had a similar failure mode. The stiffness, bearing capacity, ductility, and energy dissipation were comparable. The hysteresis curves were full and showed that the joints had good energy dissipation. The presence of prestressing tendons limited the development of cracks in the precast beams. The concrete strength of the keyway area had little effect on the seismic performance of the precast prestressed concrete joints. The precast prestressed concrete joints had a seismic performance that was comparable to the equivalent monolithic system.


2018 ◽  
Vol 7 (1) ◽  
pp. 126
Author(s):  
Latha M S ◽  
Revanasiddappa M ◽  
Naveen Kumar B M

An experimental investigation was carried out to study shear carrying capacity and ultimate flexural moment of reinforced cement concrete beam. Two series of simply supported beams were prepared by varying diameter and spacing of shear and flexural reinforcement. Beams of cross section 230 mm X 300 mm and length of 2000 mm. During testing, maximum load, first crack load, deflection of beams were recorded. Test results indicated that decreasing shear spacing and decreasing its diameter resulted in decrease in deflection of beam and increase in bending moment and shear force of beam.


Sign in / Sign up

Export Citation Format

Share Document