Attitude determination of system coordinate gradiometer with respect to inertial space

2018 ◽  
Vol 930 (12) ◽  
pp. 2-8
Author(s):  
A.A. Kluykov

The article represents the algorithm of attitude determination in gradiometer coordinate system with respect to inertial space. The problem can be solved in two steps. The first step is to determine the values of matrix transformation from celestial system (ICRF) to star camera coordinate system (SSRF) using observations star. The second step is to determine the values of matrix transformation from star camera coordinate system (SSRF) to gradiometer coordinate system (GRF). This problem is solved through mounting sensor systems on board of a satellite. Due to the mission GOCE three star cameras are mounted there. The matrix of transformation from star camera coordinate system (SSRF) to gradiometer coordinate system (GRF) is determined for every star camera. The values of transformation matrix are represented in file of data AUX_EGG_DB. Processing star camera’s (star cameras’) observations include the following steps

1999 ◽  
Vol 8 (5) ◽  
pp. 096369359900800
Author(s):  
C. Tallaron ◽  
S. Barre

The aim of this study is the determination of the overall elastic tensor of two 3D composites. These materials have a multiscale architecture. The representative volume element of the composite architecture (symbolised by a unit-cell) is composed of three bundles in three orthogonal directions and two matrix pockets. Each bundle is a unidirectional composite formed by a juxtaposition of long fibres surrounded by the matrix. Due to their symmetry, the bundles are considered transversally isotropic according to the fibres axis, whereas the pockets are macroscopically isotropic. The analytical computation is produced in two steps. The first step consists of determining the elastic tensor of the bundles. The second step is the calculation of the elastic tensor of the whole composite. The most part of the used equations comes from bibliography, excepted the determination of shear coefficients of the composite. The last part of this study devoted to the influence of material parameters presents the relative role of the fibres, the matrix and their volume fraction.


Author(s):  
H.J. Dudek

The chemical inhomogenities in modern materials such as fibers, phases and inclusions, often have diameters in the region of one micrometer. Using electron microbeam analysis for the determination of the element concentrations one has to know the smallest possible diameter of such regions for a given accuracy of the quantitative analysis.In th is paper the correction procedure for the quantitative electron microbeam analysis is extended to a spacial problem to determine the smallest possible measurements of a cylindrical particle P of high D (depth resolution) and diameter L (lateral resolution) embeded in a matrix M and which has to be analysed quantitative with the accuracy q. The mathematical accounts lead to the following form of the characteristic x-ray intens ity of the element i of a particle P embeded in the matrix M in relation to the intensity of a standard S


Author(s):  
Dr. G. Kaemof

A mixture of polycarbonate (PC) and styrene-acrylonitrile-copolymer (SAN) represents a very good example for the efficiency of electron microscopic investigations concerning the determination of optimum production procedures for high grade product properties.The following parameters have been varied:components of charge (PC : SAN 50 : 50, 60 : 40, 70 : 30), kind of compounding machine (single screw extruder, twin screw extruder, discontinuous kneader), mass-temperature (lowest and highest possible temperature).The transmission electron microscopic investigations (TEM) were carried out on ultra thin sections, the PC-phase of which was selectively etched by triethylamine.The phase transition (matrix to disperse phase) does not occur - as might be expected - at a PC to SAN ratio of 50 : 50, but at a ratio of 65 : 35. Our results show that the matrix is preferably formed by the components with the lower melting viscosity (in this special case SAN), even at concentrations of less than 50 %.


Author(s):  
C.T. Hu ◽  
C.W. Allen

One important problem in determination of precipitate particle size is the effect of preferential thinning during TEM specimen preparation. Figure 1a schematically represents the original polydispersed Ni3Al precipitates in the Ni rich matrix. The three possible type surface profiles of TEM specimens, which result after electrolytic thinning process are illustrated in Figure 1b. c. & d. These various surface profiles could be produced by using different polishing electrolytes and conditions (i.e. temperature and electric current). The matrix-preferential-etching process causes the matrix material to be attacked much more rapidly than the second phase particles. Figure 1b indicated the result. The nonpreferential and precipitate-preferential-etching results are shown in Figures 1c and 1d respectively.


2020 ◽  
Vol 962 (8) ◽  
pp. 24-37
Author(s):  
V.E. Tereshchenko

The article suggests a technique for relation global kinematic reference system and local static realization of global reference system by regional continuously operated reference stations (CORS) network. On the example of regional CORS network located in the Novosibirsk Region (CORS NSO) the relation parameters of the global reference system WGS-84 and its local static realization by CORS NSO network at the epoch of fixing stations coordinates in catalog are calculated. With the realization of this technique, the main parameters to be determined are the speed of displacement one system center relativly to another and the speeds of rotation the coordinate axes of one system relatively to another, since the time evolution of most stations in the Russian Federation is not currently provided. The article shows the scale factor for relation determination of coordinate systems is not always necessary to consider. The technique described in the article also allows detecting the errors in determining the coordinates of CORS network in global coordinate system and compensate for them. A systematic error of determining and fixing the CORS NSO coordinates in global coordinate system was detected. It is noted that the main part of the error falls on the altitude component and reaches 12 cm. The proposed technique creates conditions for practical use of the advanced method Precise Point Positioning (PPP) in some regions of the Russian Federation. Also the technique will ensure consistent PPP method results with the results of the most commonly used in the Russian Federation other post-processing methods of high-precision positioning.


Molecules ◽  
2021 ◽  
Vol 26 (14) ◽  
pp. 4357
Author(s):  
Waritda Pookmanee ◽  
Siriwan Thongthip ◽  
Jeeranut Tankanitlert ◽  
Mathirut Mungthin ◽  
Chonlaphat Sukasem ◽  
...  

The method for the determination of primaquine (PQ) and 5,6-orthoquinone primaquine (5,6-PQ), the representative marker for PQ active metabolites, via CYP2D6 in human plasma and urine has been validated. All samples were extracted using acetonitrile for protein precipitation and analyzed using the ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) system. Chromatography separation was carried out using a Hypersil GOLDTM aQ C18 column (100 × 2.1 mm, particle size 1.9 μm) with a C18 guard column (4 × 3 mm) flowed with an isocratic mode of methanol, water, and acetonitrile in an optimal ratio at 0.4 mL/min. The retention times of 5,6-PQ and PQ in plasma and urine were 0.8 and 1.6 min, respectively. The method was validated according to the guideline. The linearity of the analytes was in the range of 25–1500 ng/mL. The matrix effect of PQ and 5,6-PQ ranged from 100% to 116% and from 87% to 104% for plasma, and from 87% to 89% and from 86% to 87% for urine, respectively. The recovery of PQ and 5,6-PQ ranged from 78% to 95% and form 80% to 98% for plasma, and from 102% to from 112% to 97% to 109% for urine, respectively. The accuracy and precision of PQ and 5,6-PQ in plasma and urine were within the acceptance criteria. The samples should be kept in the freezer (−80 °C) and analyzed within 7 days due to the metabolite stability. This validated UHPLC-MS/MS method was beneficial for a pharmacokinetic study in subjects receiving PQ.


2021 ◽  
Vol 185 ◽  
pp. 1-13
Author(s):  
Di Zhao ◽  
Chong Sun ◽  
Zhanxia Zhu ◽  
Wenya Wan ◽  
Zixuan Zheng ◽  
...  

2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Haiyan Lei ◽  
Jianbo Guo ◽  
Zhuo Lv ◽  
Xiaohong Zhu ◽  
Xiaofeng Xue ◽  
...  

This study reports an analytical method for the determination of nitroimidazole and quinolones in honey using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A modified QuEChERS methodology was used to extract the analytes and determine veterinary drugs in honey by LC-MS/MS. The linear regression was excellent at the concentration levels of 1–100 ng/mL in the solution standard curve and the matrix standard curve. The recovery rates of nitroimidazole and quinolones were 4.4% to 59.1% and 9.8% to 46.2% with relative standard deviations (RSDs) below 5.2% and the recovery rates of nitroimidazole and quinolones by the matrix standard curve ranged from 82.0% to 117.8% and 79% to 115.9% with relative standard deviations (RSDs) lower than 6.3% in acacia and jujube honey. The acacia and jujube honeys have stronger matrix inhibition effect to nitroimidazole and quinolones residue; the matrix inhibition effect of jujube honey is stronger than acacia honey. The matrix standard curve can calibrate matrix effect effectively. In this study, the detection method of antibiotics in honey can be applied to the actual sample. The results demonstrated that the modified QuEChERS method combined with LC-MS/MS is a rapid, high, sensitive method for the analysis of nitroimidazoles and quinolones residues in honey.


Sign in / Sign up

Export Citation Format

Share Document