scholarly journals SUSCETIBILIDADE ANTIMICROBIANA E FATORES DE VIRULÊNCIA DE STAPHYLOCOCCUS EM FÔMITES DO HOSPITAL UNIVERSITÁRIO SUL FLUMINENSE

2017 ◽  
Vol 21 (3) ◽  
pp. 245-254 ◽  
Author(s):  
Caroline Da Costa NOEL ◽  
Francine Motta SILVÉRIO ◽  
Neila Lilyane Da Silva Gomes FRANCISCO ◽  
Nádia Rossi de ALMEIDA ◽  
Lidiane De Castro SOARES

Objetivo: Caracterizar os fatores de virulência e o perfil de suscetibilidade antimicrobiana de isolados de Staphylococcus spp. provenientes de amostras de jaleco e estetoscópio dos profissionais de saúde, e das maçanetas das portas da enfermaria e Unidade de Terapia Intensiva do Hospital Universitário Sul Fluminense. Material e Métodos: As amostras de estetoscópio, maçaneta e jaleco, foram coletadas com“swab” estéril umedecido em solução salina e foram colocados em caldo Infusão de Cérebro e Coração Bovino (BHI) e incubados por 24-48h a 37ºC para o crescimento. Foram feitas as identificações necessárias para caracterização dos fatores de virulência e o perfil de suscetibilidade antimicrobiana de isolados de Staphylococcus spp. no laboratório de Microbiologia da Universidade Severino Sombra. Resultados: Foi obtido um total de 59 Staphylococcus spp, identificados como Staphylococcus aureus (n=6) e Staphylococcus coagulase negativos (n=53). Do grupo coagulase-negativo foram identificados 34 isolaods de Staphylococcus epidermidis e 19 de Staphylococcus saprophyticus. Em relação aos fatores de virulência, 76,3% isolados foram produtores de “slime”. A hemólise foi detectada em 50,9% dos isolados, destes 35,6% apresentaram hemólise total e 15,3% a hemólise parcial. O sinergismo hemolítico foi positivo em 59,3% dos isolados sendo que destes, 13 não apresentaram hemolisinas. De acordo com o perfil de suscetibilidade, 96,6% foram resistentes à penicilina. A gentamicina foi o antibiótico que apresentou menor percentual de resistência (15,3%). Conclusão: Os jalecos, estetoscópios e maçanetas das portas, podem ser considerados como um veículo potencial para transmissão de micro-organismo dentro do ambiente hospitalar. DESCRITORES: Fatores de Virulência. Antibiograma. Staphylococcus.

2017 ◽  
Vol 23 (1-2) ◽  
pp. 65-74
Author(s):  
Gloria I. Morales-Parra ◽  
María C. Yaneth-Giovanetti ◽  
Andrés B. Zuleta-Hernández ◽  
Marilyn L. Núñez-Carrillo

Introducción: las infecciones por Staphylococcus spp. multirresistentes están asociadas con una mayor morbimortalidad de los pacientes afectados. Objetivo: caracterizar fenotipos de resistencia a meticilina, macrólidos y lincosamidas de 50 aislados de Staphylococcus spp. provenientes de pacientes de un centro hospitalario en la ciudad de Valledupar (Colombia). Materiales y métodos: las pruebas de susceptibilidad a meticilina, eritromicina y clindamicina se realizaron por los métodos de microdilución en caldo y difusión en agar. La resistencia a meticilina se tamizó por la técnica de dilución en agar y la resistencia inducible a clindamicina por la prueba D. Resultados: los aislados de Staphylococcus fueron obtenidos principalmente de heridas (58%) y orinas (12%) y en las áreas de consulta externa (40%), cirugía (24%) y urgencias (10%). Staphylococcus aureus se aisló en un 68%, seguido de Staphylococcus epidermidis (14%), Staphylococcus lugdunensis (8%), Staphylococcus saprophyticus (4%), Staphylococcus haemolyticus (4%) y Staphylococcus hominis (2%). La resistencia a meticilina se encontró en el 36% de los aislados de Staphylococcus aureus y el 8% de los estafilococos coagulasa negativos. Se evidenciaron cinco fenotipos de resistencia; el fenotipo con sensibilidad a eritromicina y clindamicina fue el más frecuente (54%), seguido del de resistencia a ambos antibióticos (14%). La resistencia inducible a clindamicina fue del 12%, encontrándose en el 8% de aislados de Staphylococcus aureus y el 4% de los de Staphylococcus epidermidis. Conclusiones: la prueba D es esencial para detectar el fenotipo de resistencia inducible a clindamicina en aislados de Staphylococcus spp. y evitar su administración frente al inminente fracaso terapéutico.


UNICIÊNCIAS ◽  
2019 ◽  
Vol 23 (2) ◽  
pp. 105
Author(s):  
Vivian Tallita Pinheiro de Santana ◽  
Phelipe Magalhães Duarte ◽  
Uvleique Alves Fernandes ◽  
Gabriel Moreno Damião ◽  
Amanda Lourença Da Silva

Rápidos, portáteis e acessíveis, os aparelhos celulares foram incorporados às atividades e rotinas diárias da população. Diante de tal intimidade, esses aparelhos também passaram a se constituir em um meio de crescimento para agentes microbiológicos comensais e acidentais. Medidas de controle como a adoção de boas práticas de higiene são imprescindíveis para a diminuição da carga microbiológica e, por consequência, decréscimo dos riscos de transmissão destes agentes ao homem, principalmente em imunodeprimidos. Dessa forma, o presente trabalho objetivou identificar os micro-organismos presentes em aparelhos celulares de acadêmicos e professores da Universidade de Cuiabá (UNIC), Campus Primavera do Leste – MT, através de amostragens obtidas de 24 aparelhos de telefones celulares de voluntários. Foram realizadas coletas para cada um dos aparelhos celulares disponibilizados pelos voluntários, através de um swab de transporte. Este foi deslizado na parte externa do aparelho, cobrindo toda a área da tela, conectores e alto-falante e, em seguida, inseridos em meio Stuart e remetidos ao laboratório. Do total de amostras coletadas, 19 (79,1%) apresentaram crescimento bacteriano em meio de cultura nutritivo. Os micro-organismos isolados foram Staphylococcus aureus em seis amostras (31,6%), Staphylococcus lugdunensis em outras seis (31,6%), Staphylococcus epidermidis em três (15,8%), Staphylococcus spp. em três (5,8%) e Escherichia coli em uma (5,2%) das amostras. Diante dos resultados obtidos se pôde constatar que os aparelhos celulares podem atuar como meio de multiplicação microbiológica, assim se deve adotar medidas preventivas de higiene e antissepsia das mãos e destes aparelhos, a fim de evitar a proliferação e veiculação de micro-organismos por meio destes. Palavras-chave: Telefone Celular. Staphylococcus aureus.  Escherichia coli. AbstractFast, portable and affordable, mobile phones have been incorporated into the daily activities and routines of the population. Faced with such intimacy, these devices have also become a growth medium for commensal and accidental microbiological agents. Control measures such as the adoption of good hygiene practices are essential to reduce the microbiological load and, consequently, decrease the risks of transmission of these agents to humans, especially in immunosuppressed ones. Thus, the present work aimed to identify the microorganisms present in cell phones of academics and professors of the University of Cuiabá (UNIC), Campus Primavera do Leste - MT, through samples obtained from 24 cell phones of volunteers. The samples  were collected for each of the mobile devices made available by the volunteers through a transport swab. This was slid on the external part of the device, covering the entire display area, connectors and speaker, then inserted into Stuart medium and sent to the lab. Of the total samples collected, only 19 (79.1%) showed bacterial growth in nutrient culture medium. Microorganisms isolated from growth media were Staphylococcus aureus in six samples (31.6%), Staphylococcus lugdunensis in six (31.6%), Staphylococcus epidermidis in three (15.8%), Staphylococcus spp. in three (5.8%) and Escherichia coli in one (5.2%) of the samples. Given the results obtained, it can be seen that cell phones can act as a means of microbiological multiplication, so preventive measures of hygiene and antisepsis of  hands should be adopted, in order to prevent the proliferation and spread of microorganisms through them . Keyword: Cell Phone. Staphylococcus aureus.  Escherichia coli. 


Author(s):  
Fernanda De Barros Silveira ◽  
Nayanna Dias Bierhals ◽  
Silvio Augusto Ortolan ◽  
Betina BRIXNER ◽  
Jane Dagmar Pollo Renner

A unidade de terapia intensiva (UTI) é um ambiente hospitalar propício para disseminação de patógenos multirresistentes. As superfícies inanimadas e instrumentos próximos aos pacientes, principalmente aqueles que entram em contato com a pele e a mucosa, devem ser consideradas fontes de contaminação. Nesse contexto, o estudo teve como objetivo identificar a presença de Staphylococcus spp. em uma UTI adulto de um hospital localizado no interior do Rio Grande do Sul (RS). Realizou-se um estudo transversal em abril de 2017, onde foram coletadas 22 amostras de 13 superfícies/equipamentos de manipulação rotineira (telefone, pia e bancada de preparo de medicações, monitores, teclados de computadores, torneiras dos funcionários e familiares, suporte do clorexidine, painel e pinça do aparelho de hemodiálise, mesas, estetoscópios e bombas de infusão, bem como no espaço entre as mesmas) na UTI adulto. Foram realizadas a coloração de Gram e as provas de catalase, coagulase e Dnase para identificação de gênero e espécie. O antibiograma foi realizado pelo teste de difusão em disco e a resistência à meticilina em ágar cromogênico MRSA. Foram isolados microrganismos em 19 superfícies inanimadas e equipamentos. O Staphylococcus coagulase negativa (SCN) (36,84%) foi o patógeno mais identificado nestas superfícies, seguido de Staphylococcus aureus (31,57%). Os SCN foram 71,4% resistentes à penicilina, 85,7% à eritromicina e 57,1% à clindamicina. Dos S. aureus isolados, 83,3% foram resistentes à penicilina, 50,0% à meticilina, 66,7% à eritromicina e 50,0% à clindamicina. Conclui-se que as superfícies inanimadas podem ser consideradas fontes de contaminação. Os resultados demonstram uma alta prevalência de contaminação ambiental por SCN e S. aureus, com cepas multirresistentes.   Palavras-chave: Infecção Hospitalar. Unidade de Terapia Intensiva. Contaminação. Contaminação de Equipamentos. Resistência Microbiana a Antibióticos.   Abstract The intensive care unit (ICU) is a favorable hospital environment for the dissemination of multidrug-resistant pathogens. Inanimate surfaces and instruments close to patients, especially those that come into contact with the skin and mucosa, should be considered sources of contamination. In this context, the study aimed to identify the presence of Staphylococcus spp. in an adult ICU of a hospital located in the interior of Rio Grande do Sul (RS). A cross-sectional study was carried out in April 2017, where 22 samples were collected from 13 surfaces / routine handling equipment (telephone, sink and medication preparation bench, monitors, computer keyboards, taps for employees and family members, chlorhexidine support, panel and forceps of the hemodialysis device, tables, stethoscopes and infusion pumps, as well as in the space between them) in the adult ICU. Gram stain and catalase, coagulase and DNase tests were performed to identify genus and species. The antibiogram was performed using the disk diffusion test and methicillin resistance on MRSA chromogenic agar. Microorganisms were isolated on 19 inanimate surfaces and equipment. Coagulase negative Staphylococcus (CNS) (36.84%) was the pathogen most identified on these surfaces, followed by Staphylococcus aureus (31.57%). The CNS were 71.4% resistant to penicillin, 85.7% to erythromycin and 57.1% to clindamycin. Of the isolated S. aureus, 83.3% were resistant to penicillin, 50.0% to methicillin, 66.7% to erythromycin and 50.0% to clindamycin. It is concluded that inanimate surfaces can be considered sources of contamination. The results demonstrate a high prevalence of environmental contamination by CNS and S. aureus, with multi-resistant strains.   Keywords: Cross Infection. Intensive Care Units. Contamination. Equipment Contamination. Drug Resistance.  


Author(s):  
Makselina Ayu Dwi Purwanti ◽  
I Nengah Kerta Besung ◽  
I Gusti Ketut Suarjana

Penelitian ini dilakukan untuk mendeteksi Staphylococcus sp. di saluran pernapasan babi. Sampel dibedakan berdasarkan jenis kelamin (babi jantan dan babi betina). Sebanyak 100 sampel usapan hidung dikumpulkan secara aseptik dari babi yang menunjukkan gejala penyakit respirasi, yang diambil dari peternakan babi di daerah Badung dan Tabanan. Semua sampel ditanam pada media Blood Agar selama 18-24 jam pada suhu 37°C. Koloni yang dicurigai kemudian dilakukan pewarnaan Gram, uji primer (uji katalase dan oksidase), dan serangkaian tes biokimia. Analisis statistik (Chi-square) dilakukan untuk mengetahui perbedaan jumlah sampel positif Staphylococcus sp. terisolasi antara babi jantan dan babi betina. Dari 100 sampel, tujuh sampel positif Staphylococcus sp. (enam dari babi jantan dan satu dari babi betina). Secara statistik, jumlah babi jantan yang terinfeksi Staphylococcus sp. lebih tinggi (P<0,01) dibandingkan dengan babi betina. Spesies Staphylococcus yang diisolasi adalah: Staphylococcus aureus, Staphylococcus epidermidis, dan Staphylococcus saprophyticus.


RAHIS ◽  
2021 ◽  
Vol 18 (4) ◽  
pp. 122
Author(s):  
Raquel Moreira Borges ◽  
Gilvania Cristina Silva Oliveira ◽  
Cristiane Maria dos Anjos de Ávila ◽  
Geovanne D’Alfonso Junior

INTRODUÇÃO: Com a evolução da tecnologia e a disponibilização de telefonia móvel tornou-se cada dia mais comum estes aparelhos fazerem parte da rotina da população e também dos profissionais de saúde inclusive em seus ambientes de trabalho. Apesar dessa tecnologia trazer benefícios, pesquisadores têm associado a presença de patógenos de origem hospitalar em dispositivos de profissionais de saúde, o que torna susceptível a possíveis infecções e o carreamento desses agentes. Como o telefone móvel está em uso rotineiro, sendo visto inclusive em postos de enfermagem, surge à indagação e a necessidade de avaliarmos se há colonização destes aparelhos e quais agentes.   OBJETIVO: Verificar se há colonização de telefones móveis dos profissionais de saúde (enfermagem) e se há alguma rotina de higienização dos celulares e se há adesão a higienização de mãos.   METODOLOGIA: Foi aplicado um questionário aos profissionais de enfermagem de um hospital geral do interior de Minas Gerais, a amostra constou de 50 servidores, após foi coletado Swab umedecidos em caldo BHI (Brain Heart Infusion) dos telefones celulares deste profissionais. Após os swabs foram  inoculados nos meios sólidos Ágar Sangue Colúmbia (Ágar MacConkey (meio seletivo e diferencial para detecção de bacilos entéricos Gram negativos, fermentadores ou não da lactose, em amostras diversas) e Ágar Chocolate (utilizado para o cultivo de microrganismos exigentes, embora cresçam neste meio quase todos os tipos de microrganismos. (meio nutricionalmente rico, não seletivo, geralmente utilizado para o isolamento e cultivo de microrganismos fastidiosos e não fastidiosos de uma variedade de materiais clínicos e não clínicos, possibilitando a verificação da atividade hemolítica das colônias). Foram  incubadas em estufa a 35ºC ± 1ºC por 24 a 48 horas e após realizado a leitura do crescimento microbiológico.   RESULTADOS: Após a coleta do material e análise das mesmas em laboratório, observado que houve crescimento em 33 amostras (66%), dentre os microorganismos identificados nas culturas temos: Staphylococcus aureus, Staphylococcus epidermides, Staphylococcus spp, Staphylococcus lugdunenis, Staphylococcus haemolyticus, Staphylococcus saprophyticus, Bastonetes gram negativos, Bastontes gram positivos e Candida sp.   CONCLUSÃO: Conclui-se que há colonização dos aparelhos celulares, que podem proporcionar a propagação de agentes infecciosos e atuar diretamente na disseminação de microorganismos no ambiente hospitalar.


2003 ◽  
Vol 37 (6) ◽  
pp. 775-779 ◽  
Author(s):  
Álvaro B Serafini ◽  
Maria Cláudia D P B André ◽  
Márcia A V Rodrigues ◽  
André Kipnis ◽  
Cynthia O Carvalho ◽  
...  

OBJETIVO: Determinar a prevalência de microrganismos indicadores e potencialmente patogênicos que indicam as condições higiênico-sanitárias das amostras de leite humano ordenhado coletadas em banco de leite. MÉTODOS: Foram realizadas análises microbiológicas de 338 amostras de leite humano ordenhado, sendo 194 de leite cru e 144, pasteurizado, coletadas em banco de leite humano de um hospital materno infantil de Goiânia, GO. As análises microbiológicas foram realizadas com semeadura em ágar Mc Conkey, de acordo com o tipo de bactéria. RESULTADOS: No leite cru, verificou-se a presença de Staphylococcus spp. Streptococcus spp., bolores e leveduras e Enterobacteriaceae. Observou-se que Staphylococcus aureus esteve presente em 10 (5,2%) amostras, Staphylococcus epidermidis em 28 (14,4%), Streptococcus spp. em três (1,6%), bolores e leveduras em 43 (22,2%) e Enterobacteriaceae em 49 (25,3%). Das 144 amostras de leite humano ordenhado pasteurizado, detectaram-se Staphylococcus aureus em cinco (3,5%), Staphylococcus epidermidis em 15 (10,4%), Staphylococcus lugdenensis em duas (1,4%), Streptococcus spp. em quatro (2,8%), bolores e leveduras em 37 (25,7%) e Enterobacteriaceae em nove (6,3%). CONCLUSÕES: Os resultados mostraram um alto grau de contaminação no leite cru. No leite pasteurizado, apesar da eliminação da grande maioria de microrganismos potencialmente patogênicos, a percentagem de bolores e leveduras excedeu a de leite cru, mostrando a necessidade de obtenção de um leite com carga microbiana inicial mais baixa para que a pasteurização seja eficiente no controle microbiológico.


2018 ◽  
Vol 2 (2) ◽  
pp. 34
Author(s):  
Maria Gomes Pereira Gildo ◽  
Lilian Cortez Sombra Vandesmet ◽  
Cicero Ramon Bezerra dos Santos ◽  
Edmir Geraldo de Siqueira Fraga ◽  
Isabel Cristina Oliveira de Morais

Infecção hospitalar (IH) ou infecção nosocominal se define como qualquer doença infecciosa contraída após a hospitalização do paciente, mesmo que o indivíduo não tenha apresentado sinais e sintomas antes de seu internamento. Para que o processo infeccioso se instale, o microrganismo depende de uma falha no sistema de defesa do hospedeiro, o qual pode ou não manifestar a patologia. A utilização de desinfetantes com ácido peracético e o hipoclorito de sódio são métodos que conferem maior potencial antimicrobiano. No entanto, diversos microrganismos possuem mecanismos de resistência frente a medidas comumente adotadas para desinfecção. A pesquisa objetivou avaliar a eficácia antimicrobiana de desinfetantes utilizados no setor pediátrico e unidade de terapia intensiva neonatal, além de verificar a presença ou ausência de microrganismos em superfícies inanimadas pertencentes ao local de estudo assim como verificar a qualidade da higienização. Foi realizado o teste de coloração de Gram, catalase e coagulase para identificação morfológica e para a avaliação da eficácia dos produtos foi utilizado o teste de concentração inibitória mínima, onde foram usadas cepas padrões como Staphylococcus epidermidis, Staphylococcus aureus, Streptococcus pneumoniae, Pseudomonas ssp e Eschericia coli. Na avaliação da eficácia somente na cepa referente a Streptococcus pneumoniae obteve Inibição em concentração até 0,3µl (Total). Diante do exposto pode-se concluir que, observou-se uma contaminação de microrganismos bacterianos nos setores de pediatria e UTI neonatal, bem como uma eficácia dos agentes químicos utilizados na higienização dos setores, mas ou mesmo tempo os produtos se comportaram de maneira ineficaz.


2009 ◽  
Vol 45 (4) ◽  
pp. 795-800 ◽  
Author(s):  
Fausto Rodrigo Victorino ◽  
Clovis Monteiro Bramante ◽  
Evandro Watanabe ◽  
Izabel Yoko Ito ◽  
Selma Luci Franco ◽  
...  

This study evaluated the antibacterial activity of propolis-based toothpastes used as intracanal medication in endodontic treatment. The propolis-based toothpastes were prepared using an extract established in previous studies (identified as A70D and D70D). Calcium hydroxide paste was used as a control. The bacteria employed were Streptococcus mutans (ATCC 25175), Staphylococcus aureus (ATCC 6538), Staphylococcus aureus (ATCC 25923), Kocuria rhizophila (ATCC 9341), Escherichia coli (ATCC 10538), Pseudomonas aeruginosa (ATCC 27853), Enterococcus hirae (ATCC 10541), Streptococcus mutans (ATCC 25175). Five field strains isolated from saliva were used: Staphylococcus spp. (23.1 - coagulase positive), Staphylococcus spp. (23.5 - coagulase negative), Staphylococcus spp. (26.1 - coagulase positive), Staphylococcus spp. (26.5 - coagulase negative) and Staphylococcus epidermidis (6epi). The diffusion-well method on double-layer agar was used in a culture medium of Tryptic Soy Agar. The plates were kept at room temperature for two hours to allow the diffusion of pastes in the culture medium, and then incubated at 35º C for twenty-four hours in aerobiosis and in microaerophilia (S. mutans). After this period, the total diameter of the inhibition halo was measured. The results were analyzed by ANOVA analysis of variance, followed by the Tukey test at p<0.05. The propolis-based toothpastes presented antibacterial activity against 83.3% of the analyzed bacteria. For 66.7% of these bacteria, the propolis-based toothpastes exhibited greater antibacterial activity than calcium hydroxide. The present results allow us to conclude that the experimental pastes A70D and D70D showed good activity against aerobic bacteria, proving more effective than calcium hydroxide.