scholarly journals In Vitro Effects of Resin Infiltration on Enamel Erosion Inhibition

2015 ◽  
Vol 40 (5) ◽  
pp. 492-502 ◽  
Author(s):  
GC Oliveira ◽  
AP Boteon ◽  
FQ Ionta ◽  
MJ Moretto ◽  
HM Honório ◽  
...  

SUMMARY Resin-based materials that show promising effects for preventing the progression of erosion have been studied. This in vitro study evaluated the effects of applying resin-based materials, including resin infiltration, on previously eroded enamel subjected to erosive challenges. The influence of enamel surface etching prior to application of the material was also studied. Bovine enamel blocks were immersed in hydrochloric acid (HCl), 0.01 M (pH 2.3), for 30 seconds in order to form a softened erosion lesion. The blocks were then randomly divided into nine groups (n=12) and treated as follows: C = control without treatment; Hel = pit & fissure resin sealant (Helioseal Clear); Adh = two-step self-etching adhesive system (AdheSe); Tet = two-step conventional adhesive system (Tetric N-bond); and Inf = infiltrant (Icon). The Helno, Adhno, Tetno, and Infno groups received the same materials without (or with no) surface conditioning. The depth of the material's penetration into softened erosion lesions was qualitatively analyzed using reflection and fluorescence confocal microscopy. After application of the materials, the blocks were immersed in HCl for two minutes; this step was followed by immersion in artificial saliva for 120 minutes four times a day for five days (erosive cycling). Both the enamel alteration and material thickness were analyzed using profilometry, and the results were submitted to Kruskal-Wallis and Dunn tests (p>0.05). Images from the confocal microscopy showed minimal penetration of Adh/Adhno and deep penetration of Inf/Infno into the erosive lesions. The groups Hel, Adh, Inf, Tetno, and Infno resulted in the formation of a layer of material over the enamel, which was effective in inhibiting the progression of erosion. In conclusion, the infiltrant, with or without etching, was able to penetrate and protect the enamel against dental erosion. The other resin-based materials, except for the two-step conventional adhesive, were able to penetrate and inhibit the progression of erosive lesions only when they were applied after enamel etching.

2004 ◽  
Vol 18 (2) ◽  
pp. 162-167 ◽  
Author(s):  
Roberta Tarkany Basting ◽  
Patrícia Moreira de Freitas ◽  
Luiz André Freire Pimenta ◽  
Mônica Campos Serra

This in vitro study evaluated the shear bond strength (SBS) of dentin treated with two 10% carbamide peroxide bleaching agents 15 days after bleaching and storage in artificial saliva. Dentin fragments were randomly divided into 3 groups (n = 20) for the treatment with the two different bleaching agents (Rembrandt 10% or Opalescence 10%) or with a placebo agent, applied to the tooth surface for 8 hours a day. During the remaining time, the specimens were stored in artificial saliva. After 42 days, the fragments were stored in artificial saliva for 14 days. Another group (n = 20) was exposed to distilled and deionized water for 56 days. An adhesive system and microhybrid composite resin were used to prepare specimens for the SBS test. SBS tests were performed and the fractured surfaces were visually examined using a stereoscope at 30 X magnification. The analysis of variance (ANOVA) and SIDAK tests showed higher SBS values for dentin treated with Opalescence 10% than for dentin treated with Rembrandt 10% or placebo. Groups treated with Rembrandt 10%, Opalescence 10% or placebo did not differ from the group treated with distilled and deionized water. Ten percent carbamide peroxide agents or a placebo agent caused no differences in SBS of dentin after 15 days of storage in artificial saliva.


2021 ◽  
Vol 37 ◽  
pp. e37005
Author(s):  
Laerte Ribeiro Menezes-Júnior ◽  
Marcos Alan Vieira Bittencourt ◽  
Andomar Bruno Fernandes Vilela ◽  
Carlos José Soares ◽  
Diego Figueiredo Nóbrega ◽  
...  

This study aimed to analyze the shear bond strength (SBS) of ceramic orthodontic brackets bonded with two different adhesive systems to intact and eroded teeth. Ceramic brackets were bonded to 72 bovine central incisors divided into four groups, defined by two study factors: enamel condition (control group, kept in artificial saliva; and experimental group, eroded by using immersion cycles in Coke™ for 90 seconds, every six hours for five days), and adhesive system type (Transbond™ XT or Transbond™ Plus Color Change). Polycrystalline ceramic brackets were adhesively fixed on all specimens using the same light curing protocol. SBS was tested using 0.5 mm/min and the failure mode was classified. SBS data was analyzed using two-way ANOVA followed by Tukey test. The adhesive remnant index (ARI) scores were analyzed using Kruskal-Wallis test with Dunn's post-hoc pairwise comparison (α=0.05). Percentages of ARI scores between the groups were compared by Fisher’s exact test. Spearman's correlation coefficient was applied to investigate the correlation between ARI scores and SBS values. Only the adhesive system factor had significant effect on SBS (p=0.014), Transbond™ Plus Color Change showing higher values. No significance was found for enamel condition (p=0.665) or the interaction between adhesive system and enamel condition (p=0.055). ARI scores frequencies differed between groups (p<0.001). The median ARI scores were statistically different for most comparisons among the groups. However, no significant correlation was found between ARI scores and SBS. In conclusion, the type of adhesive system affected the SBS of ceramic brackets to dental enamel, but the enamel condition, intact or eroded, had no significant effect. There was no correlation between ARI scores and SBS values, although eroded enamel tended to retain more adhesive after bracket removal.


2008 ◽  
Vol 02 (02) ◽  
pp. 086-090 ◽  
Author(s):  
Hale Ară ◽  
Nazmiye Dönmez ◽  
Sema Belli

ABSTRACTObjectives: The purpose of this in vitro study was to evaluate the effect of artificial saliva contamination on microtensile bond strength to pulp chamber dentin.Methods: Clearfil SE Bond (SEB) (Kuraray, JAPAN) adhesive system and Clearfil Photo Posterior (CPP) (Kuraray, JAPAN) composite resin were used. Twenty extracted caries-free human molar teeth were randomly distributed into four groups. Apart from a control group without contamination (Group 1), primed dentin surfaces were contaminated with artificial saliva (10 s), rinsed, dried, reprimed and bonded (Group 2), coated with adhesive, contaminated with artificial saliva, rinsed, dried, bonding procedures were repeated (Group 3), coated with adhesive, light cured, contaminated with saliva, rinsed, dried, treated with SE primer (SEP) and SEB (Group 4).After 24 hrs, the teeth were prepared for microtensile bond testing and tensile bond strength was measured (1mm/min). The data was calculated as MPa and analyzed using one-way ANOVA and Duncan test (P<.05).Results: The results indicated that Group 2 showed lowest bond strength when compared to the others (P<.05). No statistically significant difference was found between Groups 3 and 4 (P>.05).Conclusions: It was concluded that contamination during priming procedure has a negative effect on bond strength (P<.05). Although contamination of the uncured adhesive was not critical in this study (P>.05) any kind of contamination of the bonding area should, in principle, be avoided. (Eur J Dent 2008;2:86-90)


1990 ◽  
Vol 64 (03) ◽  
pp. 402-406 ◽  
Author(s):  
M D Oethinger ◽  
E Seifried

SummaryThe present in vitro study investigated dose-, time- and temperature-dependent effects of two-chain urokinase plasminogen activato(u-PA, urokinase) on normal citrated plasma. When 10 μg/ml u-PA wereadded to pooled normal plasma and incubated for 30 min at an ambient temperature (25° C), α2-antiplas-min decreased to 8% of the control value. Incubation on ice yielded a decrease to 45% of control,whereas α2-antiplasmin was fully consumed at 37° C. Fibrinogen and plasminogen fell to 46% and 39%, respectively, after a 30 min incubation at 25° C. Thrombin time prolonged to 190% of control.Various inhibitors were studied with respect to their suitability and efficacy to prevent these in vitro effects. Aprotinin exhibited a good protective effect on fibrinogen at concentrations exceeding 500 KlU/ml plasma. Its use, however, was limited due to interferences with some haemostatic assays. We could demonstrate that L-Glutamyl-L-Glycyl-L-Arginyl chloromethyl ketone (GGACK) and a specific polyclonal anti-u-PA-antibody (anti-u-PA-IgG) effectively inhibited urokinase-induced plasmin generation without interfering with haemostatic assays. The anti-u-PA-antibody afforded full protection ofα2-antiplasmin at therapeutic levels of u-PA.It is concluded that u-PA in plasma samples from patients during thrombolytic therapy may induce in vitro effects which should be prevented by the use of a suitable inhibitor such as GGACK or specific anti-u-PA-antibody.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Philipp Körner ◽  
Luca Georgis ◽  
Daniel B. Wiedemeier ◽  
Thomas Attin ◽  
Florian J. Wegehaupt

Abstract Background This in-vitro-study aimed to evaluate the potential of different fluoride gels to prevent gastroesophageal reflux induced erosive tooth wear. Methods Surface baseline profiles of a total of 50 bovine enamel specimens [randomly assigned to five groups (G1–5)] were recorded. All specimens were positioned in a custom made artificial oral cavity and perfused with artificial saliva (0.5 ml/min). Reflux was simulated 11 times a day during 12 h by adding HCl (pH 3.0) for 30 s (flow rate 2 ml/min). During the remaining 12 h (overnight), specimens were stored in artificial saliva and brushed twice a day (morning and evening) with a toothbrush and toothpaste slurry (15 brushing strokes). While specimens in the control group (G1) did not receive any further treatment, specimens in G2–5 were coated with different fluoride gels [Elmex Gelée (G2); Paro Amin Fluor Gelée (G3); Paro Fluor Gelée Natriumfluorid (G4); Sensodyne ProSchmelz Fluorid Gelée (G5)] in the evening for 30 s. After 20 days, surface profiles were recorded again and enamel loss was determined by comparing them with the baseline profiles. The results were statistically analysed using one-way analysis of variance (ANOVA) followed by Tukey`s HSD post-hoc test. Results The overall highest mean wear of enamel (9.88 ± 1.73 µm) was observed in the control group (G1), where no fluoride gel was applied. It was significantly higher (p < 0.001) compared to all other groups. G2 (5.03 ± 1.43 µm), G3 (5.47 ± 0.63 µm, p = 0.918) and G4 (5.14 ± 0.82 µm, p > 0.999) showed the overall best protection from hydrochloric acid induced erosion. Enamel wear in G5 (6.64 ± 0.86 µm) was significantly higher compared to G2 (p = 0.028) and G4 (p = 0.047). Conclusions After 20 days of daily application, all investigated fluoride gels are able to significantly reduce gastroesophageal reflux induced loss of enamel.


Polymers ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 2998
Author(s):  
Mohammed Nadeem Bijle ◽  
Manikandan Ekambaram ◽  
Edward Lo ◽  
Cynthia Yiu

The in vitro study objectives were to investigate the effect of arginine (Arg) incorporation in a 5% sodium fluoride (NaF) varnish on its physical and chemical properties including F/Arg release. Six experimental formulations were prepared with L-arginine (L-Arg) and L-arginine monohydrochloride at 2%, 4%, and 8% w/v in a 5% NaF varnish, which served as a control. The varnishes were subjected to assessments for adhesion, viscosity, and NaF extraction. Molecular dynamics were simulated to identify post-dynamics total energy for NaF=Arg/Arg>NaF/Arg<NaF concentrations. The Arg/F varnish release profiles were determined in polyacrylic lactate buffer (pH-4.5; 7 days) and artificial saliva (pH-7; 1 h, 24 h, and 12 weeks). Incorporation of L-Arg in NaF varnish significantly influences physical properties ameliorating retention (p < 0.001). L-Arg in NaF varnish institutes the Arg-F complex. Molecular dynamics suggests that NaF>Arg concentration denotes the stabilized environment compared to NaF<Arg (p < 0.001). The 2% Arg-NaF exhibits periodic perennial Arg/F release and shows significantly higher integrated mean F release than NaF (p < 0.001). Incorporating 2% L-arginine in 5% NaF varnish improves its physical properties and renders a stable matrix with enduring higher F/Arg release than control.


2021 ◽  
Author(s):  
Lethycia Almeida Santos ◽  
Tatiana Martini ◽  
João Victor Frazão Câmara ◽  
Fabiana Navas Reis ◽  
Adriana de Cássia Ortiz ◽  
...  

The effect of solutions and gels containing a sugarcane-derived cystatin (CaneCPI-5) on the protection against enamel and dentin erosion in vitro was evaluated. Bovine enamel and dentin specimens were divided into two groups (n=135 and 153/group for enamel and dentin, respectively) that were treated with solutions or chitosan gels containing 0.1 or 0.25 mg/ml CaneCPI-5. The positive controls for solutions and gels were Elmex Erosion Protection™ solution and NaF gel (12,300 ppm F), respectively. Deionized water and chitosan gel served as controls, respectively. The solutions were first applied on the specimens for 1 min and the gels for 4 min. Stimulated saliva was collected from 3 donors and used to form a 2 h acquired pellicle on the specimens. Then, the specimens were submitted to an erosive pH cycling protocol 4 times/day for 7 days (0.1% citric acid pH 2.5/90s, artificial saliva/2h, artificial saliva overnight). The solutions and gels were applied again during pH cycling, 2 times/day for 1 min and 4 min, respectively, after the first and last erosive challenges. Enamel and dentin losses (µm) were assessed by contact profilometry. Data were analyzed by 2-way ANOVA and Tukey´s test (p <0.05). All the treatments significantly reduced enamel and dentin loss in comparison with controls. Both CaneCPI-5 concentrations had a similar protective effect against enamel erosion, but only the higher concentration was as effective against dentin erosion as the positive control. Regarding the vehicles, only the 0.1 mg/ml gel performed worse than the positive control for dentin. CaneCPI-5 reduced enamel and dentin erosion to a similar extent as the fluoride-containing vehicles. However, dentin requires higher CaneCPI-5 concentrations, in the case of gels. Solutions or gels containing CaneCPI-5 might be a new approach to protect against dental erosion.


2012 ◽  
Vol 17 (4) ◽  
pp. 1-7 ◽  
Author(s):  
Roberto Hideo Shimizu ◽  
Karlos Giovani Grando ◽  
Isabela Almeida Shimizu ◽  
Augusto Ricardo Andriguetto ◽  
Ana Cláudia Moreira Melo ◽  
...  

OBJECTIVE: This in vitro study was designed to evaluate the shear bond strength (SBS) of orthodontic metal brackets bonded by direct and indirect techniques. METHODS: Thirty healthy human maxillary premolar teeth were used. The teeth were divided into three groups of 10 teeth each: Group I - indirect bonding with SondhiTM Rapid-Set system (3M/Unitek), Group II - indirect bonding with TransbondTM XT adhesive system (3M/Unitek) and Group III - direct bonding with TransbondTM XT adhesive system (3M/Unitek). After bonding and obtaining the specimens for the study, the specimens were subjected to SBS testing in a universal testing machine (Emic, model DL-500). The Kolmogorov-Smirnov test was applied to ascertain that the data had a normal distribution and the Bartlett test to check whether there was homogeneity of variance. One-factor analysis of variance was performed and, subsequently, Tukey's test for paired means. A 5% significance level was adopted. RESULTS: The results of Group I were 67.6 (N) and 5.9 (MPa); Group II, 68.9 (N) and 6.1 (MPa) and Group III (control), 92.5 (N) and 8.1 (MPa). CONCLUSION: It can therefore be concluded that the means for Group III were significantly higher compared with Groups I and II in both Newton (N) and Megapascal (MPa) values. The means attained by the indirect bonding technique used in Groups I and II, however, exhibited no statistically significant differences.


2004 ◽  
Vol 18 (3) ◽  
pp. 253-259 ◽  
Author(s):  
Fabiana Mantovani Gomes França ◽  
Flávio Henrique Baggio Aguiar ◽  
Alex José Souza dos Santos ◽  
José Roberto Lovadino

The aim of this in vitro study was to evaluate quantitatively the microleakage in class V cavities restored with one-bottle and self-etching adhesive systems with and without previous acid etching. Two one-bottle adhesive systems (Single Bond and Prime & Bond 2.1) and one self-etching adhesive system (Clearfil Mega Bond) were used in this study. One hundred and twenty sound human premolar teeth were randomly divided into 6 groups, and 20 class V restorations were prepared in the root dentin to test each bonding system. Each bonding system was used with and without acid etching. Specimens were prepared, dyed with 2% methylene blue, sectioned, triturated, and evaluated with an absorbance spectrophotometer test in order to quantify the infiltrated dye. Results were statistically evaluated by ANOVA and Tukey-Kramer test. No statistically significant differences were found among the adhesive systems when no etching agent was used. However, the Single Bond adhesive system showed statistically significant lower microleakage means than Clearfil Mega Bond and Prime & Bond 2.1 when 37% phosphoric acid was used. Single Bond and Clearfil Mega Bond adhesive systems presented similar behavior when the manufacturers' instructions were followed.


Sign in / Sign up

Export Citation Format

Share Document