Investigation in characteristics of belt conveyors and their idler rollers for coal-fired power plants

2021 ◽  
Vol 14 (3) ◽  
pp. 125-133
Author(s):  
S. Simon ◽  
D. Taeshner ◽  
T. Rieder ◽  
R. Schneider ◽  
S. Hernschier ◽  
...  

Belt conveyors are highly efficient systems used in mining and other industries to transport bulk materials, mainly brown coal and overburden, over distances ranging from short distances to several kilometres. For technical reasons, their operation is associated with noise emissions. During inspections and maintenance this can lead to increased noise exposure of employees. In the vicinity of residential buildings or in areas needing protection, exceeding the emission limits can lead to a temporary restriction of the operation of these high performance installations. Measures are required to reduce the noise impact primarily at the source or in the immediate vicinity. The acoustic and mechanical parameters are investigated on a test bench at the Technical University of Brandenburg (BTU) Cottbus-Senftenberg as part of the drive assembly tests in cooperation with LEAG. The stages of these tests are: Run-up test. In this test the supporting roller is accelerated under test load to a circumferential speed of 10 m/s and the sound pressure level is recorded. This makes it possible to calculate the sound emission as a function of the peripheral speed; Recording the geometry of the idler gear. An accurate description of the geometry of the idler housing allows conclusions to be drawn about the possible causes of excitation. The defined characteristics serve to quantify the acoustic effect of the driven rollers and derive specifications for use in belt conveyor systems. Based on the special requirements to the planned belt conveyor system, an adapted selection of low-noise idler rollers can be made at an early stage on the basis of specified parameters and confirmed test results.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Geetika Nehra ◽  
Shannon Andrews ◽  
Joan Rettig ◽  
Michael N. Gould ◽  
Jill D. Haag ◽  
...  

AbstractPerillyl alcohol (POH) has been extensively studied for the treatment of peripheral and primary brain tumors. The intranasal route of administration has been preferred for dosing POH in early-stage clinical trials associated with promising outcomes in primary brain cancer. However, it is unclear how intranasal POH targets brain tumors in these patients. Multiple studies indicate that intranasally applied large molecules may enter the brain and cerebrospinal fluid (CSF) through direct olfactory and trigeminal nerve-associated pathways originating in the nasal mucosa that bypass the blood–brain barrier. It is unknown whether POH, a small molecule subject to extensive nasal metabolism and systemic absorption, may also undergo direct transport to brain or CSF from the nasal mucosa. Here, we compared CSF and plasma concentrations of POH and its metabolite, perillic acid (PA), following intranasal or intravascular POH application. Samples were collected over 70 min and assayed by high-performance liquid chromatography. Intranasal administration resulted in tenfold higher CSF-to-plasma ratios for POH and tenfold higher CSF levels for PA compared to equal dose intravascular administration. Our preclinical results demonstrate POH undergoes direct transport from the nasal mucosa to the CSF, a finding with potential significance for its efficacy as an intranasal chemotherapeutic for brain cancer.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3716
Author(s):  
Francesco Causone ◽  
Rossano Scoccia ◽  
Martina Pelle ◽  
Paola Colombo ◽  
Mario Motta ◽  
...  

Cities and nations worldwide are pledging to energy and carbon neutral objectives that imply a huge contribution from buildings. High-performance targets, either zero energy or zero carbon, are typically difficult to be reached by single buildings, but groups of properly-managed buildings might reach these ambitious goals. For this purpose we need tools and experiences to model, monitor, manage and optimize buildings and their neighborhood-level systems. The paper describes the activities pursued for the deployment of an advanced energy management system for a multi-carrier energy grid of an existing neighborhood in the area of Milan. The activities included: (i) development of a detailed monitoring plan, (ii) deployment of the monitoring plan, (iii) development of a virtual model of the neighborhood and simulation of the energy performance. Comparisons against early-stage energy monitoring data proved promising and the generation system showed high efficiency (EER equal to 5.84), to be further exploited.


2021 ◽  
Vol 13 (16) ◽  
pp. 8789
Author(s):  
Giovanni Bianco ◽  
Barbara Bonvini ◽  
Stefano Bracco ◽  
Federico Delfino ◽  
Paola Laiolo ◽  
...  

As reported in the “Clean energy for all Europeans package” set by the EU, a sustainable transition from fossil fuels towards cleaner energy is necessary to improve the quality of life of citizens and the livability in cities. The exploitation of renewable sources, the improvement of energy performance in buildings and the need for cutting-edge national energy and climate plans represent important and urgent topics to be faced in order to implement the sustainability concept in urban areas. In addition, the spread of polygeneration microgrids and the recent development of energy communities enable a massive installation of renewable power plants, high-performance small-size cogeneration units, and electrical storage systems; moreover, properly designed local energy production systems make it possible to optimize the exploitation of green energy sources and reduce both energy supply costs and emissions. In the present paper, a set of key performance indicators is introduced in order to evaluate and compare different energy communities both from a technical and environmental point of view. The proposed methodology was used in order to assess and compare two sites characterized by the presence of sustainable energy infrastructures: the Savona Campus of the University of Genoa in Italy, where a polygeneration microgrid has been in operation since 2014 and new technologies will be installed in the near future, and the SPEED2030 District, an urban area near the Campus where renewable energy power plants (solar and wind), cogeneration units fed by hydrogen and storage systems are planned to be installed.


Author(s):  
Denis G. Karczub ◽  
Fred W. Catron ◽  
Allen C. Fagerlund

In a blow-down situation as might occur at a natural gas processing facility, noise levels are very high and significantly exceed the noise levels one would normally associate with a control valve. As the blow-down operation is an infrequent event, this may be permissible but requires consideration of the duration of these high noise levels to ensure that occupational noise exposure limits and acoustic fatigue limits are not exceeded. Tests of noise levels due to an 8-inch control valve in a 12-inch pipeline under blow-down conditions are compared here with noise level predictions based on the IEC standard. Consideration is also given to the impact of placing an orifice plate downstream of the control valve as is often done to reduce pressure drop across the valve in the expectation that control valve noise levels will be reduced. Simple orifice plates often installed by plant operators to achieve this goal are shown to have an adverse impact, and it is shown that a multi-hole diffuser or low-noise control valve should instead be used.


2021 ◽  
Author(s):  
Lin Huang ◽  
Kun Qian

Abstract Early cancer detection greatly increases the chances for successful treatment, but available diagnostics for some tumours, including lung adenocarcinoma (LA), are limited. An ideal early-stage diagnosis of LA for large-scale clinical use must address quick detection, low invasiveness, and high performance. Here, we conduct machine learning of serum metabolic patterns to detect early-stage LA. We extract direct metabolic patterns by the optimized ferric particle-assisted laser desorption/ionization mass spectrometry within 1 second using only 50 nL of serum. We define a metabolic range of 100-400 Da with 143 m/z features. We diagnose early-stage LA with sensitivity~70-90% and specificity~90-93% through the sparse regression machine learning of patterns. We identify a biomarker panel of seven metabolites and relevant pathways to distinguish early-stage LA from controls (p < 0.05). Our approach advances the design of metabolic analysis for early cancer detection and holds promise as an efficient test for low-cost rollout to clinics.


2015 ◽  
Author(s):  
William A. Hockberger

The Quadrimaran was invented in France in the mid-1980s by Daniel Tollet. It was an inspired design and a radical departure from traditional ship design by a man from outside the marine industry unconstrained by industry technical practices and education. Technical experts could see it would entail more structure and subsystems than other high-performance vessels, but its promise was that those penalties would be more than offset by its claimed low power and fuel consumption. A prototype/demonstrator, Alexander, was built in 1990 and operated for five years carrying and impressing many hundreds of riders. Alexander performed beautifully and appeared to bear out what was claimed. Contracts for several Quadrimarans of different sizes came quickly, especially considering how conservative an industry this is. That was significantly due to Tollet's personal charisma and skill in selling riders on the dream of carrying passengers and freight over the water fast and in comfort, yet economically. Great skepticism prevailed in some quarters, especially among naval architects knowledgeable about AMVs (advanced marine vehicles) and early-stage whole-ship design. At technical meetings, one Quadrimaran principal would comment, for example, "Why would you carry freight across the Atlantic at 38 knots on 230,000 horsepower (a reference to the planned Fastship Atlantic TG-770) when you could do it at 60 knots on only 65,000 horsepower?" Listeners would ask how this could be possible, and he would assert again that the Quadrimaran could do it, but would decline to explain. Respected technical people were working with Tollet and his company and becoming convinced of the Quadrimaran's merit. Along with the contracts came engineers with experience in ship detail design and construction (very different from early-stage whole-ship design), or responsibilities for assessing and approving ships for service. Others were with engine and equipment suppliers. Their opinion that there was something unique and special about the Quadrimaran gave it credibility and influenced more people to accept the major claims made for it. Some dismissed the most extreme claims but still accepted the idea that the Quadrimaran was capable of unusually high performance - considerably less than was being claimed, perhaps, but high nevertheless. In hindsight it is clear the skeptics were right. Results never met expectations, nor could they have. In reality, the Quadrimaran has aspects that inherently prevent it from achieving the characteristics and performance its inventor believed attainable. It cannot be built in a commercially useful size and actually perform as intended. Why this is so will be explained. A crucial fact in the Quadrimaran's history is that Daniel Tollet and his close associates believed strongly that naval architects and engineers who had been immersed in working with the existing ship types would be unable to give the Quadrimaran the very different treatment they believed it required. (Their own educations and professional work were nontechnical.) Such people were excluded from the development of Quadrimaran designs, and the belated discovery of many fundamental technical problems can be attributed to this. The company Tollet established had a number of names over the years, and other associated entities were created at times for various purposes. In this paper they are referred to collectively as QIH (Quadrimaran International Holdings) so as not to confuse things unnecessarily. In 2004 QuadTech Marine LLC was established and acquired the Quadrimaran patent (US Patent No. 5,191,849) and related intellectual property from QIH. QuadTech laid out an extensive R&D program to close gaps in the technical background and address identified issues. In the process, additional information on earlier QIH projects and products was obtained and studied, which brought to light problems that significantly compromised the Quadrimaran's prospective performance and utility. The resulting much-reduced set of potential uses and users led the company to effectively stop pursuing Quadrimaran projects after 2009. (Note: The author was Chief Technology Officer for QuadTech Marine during 2006-9, studying the Quadrimaran and planning the R&D.)


Author(s):  
Corey A. Honl ◽  
Ryan M. Rudnitzki

The following paper describes the release of the 220GL engine and APG2000/3000 Enginator™ product lines from Waukesha Engine. The major elements of the release that will be covered include the installation and calibration of the ESM® control system, the development of new capabilities to control fuel injection and its associated features, the integration of Waukesha-introduced components on the 220GL, high-level product strategy and justification, and early stage performance figures from development testing.


2011 ◽  
Vol 127 ◽  
pp. 295-299 ◽  
Author(s):  
Yong Cun Guo ◽  
Gang Cheng ◽  
Kun Hu ◽  
Zhu Fen Wang

Belt conveyor is widely used in mine, coal, chemical industry, ports, and power plants. It’s one of the significant devices of continuous conveyor. Roller is a crucial component with regard to belt conveyor system, which supports belts and cargos. In the design of the belt conveyor, a third of major consumption went into rollers. The critical consideration for minimum cost, which including operating, manufacturing, maintenance expenditure, is the selection of idler spacing. For optimization purposes, the optimum pitch between the rollers is regard as more decisive variable, especially for minimizing consumption and reducing rollers’ number than other various factors. This paper discusses the idler spacing to proceed from original technical first, secondly analyzes the effective factors in detail and then deduces rational arrangement mathematical expressions of idler spacing. Simultaneously, combining with the corresponding parameter, we draw up the hierarchical layout figure of idler spacing distribution through the calculation expression. It’s the optimal option of idler spacing that providing an outstanding reference in the actual production.


Author(s):  
Praveen Narasimhamurthy ◽  
Zakiul Kabir

UTC Fuel Cells (UTCFC) over the last few years has partnered with leading automotive and bus companies and developed Polymer Electrolyte Membrane (PEM) fuel-cell power plants for various transportation applications, for instance, automotive, buses, and auxiliary power units (APUs). These units are deployed in various parts of the globe and have been gaining field experience under both real world and laboratory environments. The longest running UTC PEM fuel cell stack in a public transport bus has accumulated over 1350 operating hours and 400 start-stop cycles. The longest running APU fuel cell stack has accrued over 3000 operating hours with more than 3200 start-stop cycles. UTCFC PEM fuel-cell systems are low noise and demonstrate excellent steady state, cyclic, and transient capabilities. These near ambient pressure, PEMFC systems operate at high electrical efficiencies at both low and rated power conditions.


Sign in / Sign up

Export Citation Format

Share Document