scholarly journals Effect of Yellow-Tinted Lenses on Visual Attributes Related to Sports Activities

2013 ◽  
Vol 36 (1) ◽  
pp. 27-36 ◽  
Author(s):  
Yoshimitsu Kohmura ◽  
Shigeki Murakami ◽  
Kazuhiro Aoki

The purpose of this study was to clarify the effect of colored lenses on visual attributes related to sports activities. The subjects were 24 students (11 females, 13 males; average age 21.0 ±1.2 years) attending a sports university. Lenses of 5 colors were used: colorless, light yellow, dark yellow, light gray, and dark gray. For each lens, measurements were performed in a fixed order: contrast sensitivity, dynamic visual acuity, depth perception, hand-eye coordination and visual acuity and low-contrast visual acuity. The conditions for the measurements of visual acuity and low-contrast visual acuity were in the order of Evening, Evening+Glare, Day, and Day+Glare. There were no significant differences among lenses in dynamic visual acuity and depth perception. For hand-eye coordination, time was significantly shorter with colorless than dark gray lenses. Contrast sensitivity was significantly higher with colorless, light yellow, and light gray lenses than with dark yellow and dark gray lenses. The low-contrast visual acuity test in the Day+Glare condition showed no significant difference among the lenses. In the Evening condition, lowcontrast visual acuity was significantly higher with colorless and light yellow lenses than with dark gray lenses, and in the Evening+Glare condition, low-contrast visual acuity was significantly higher with colorless lenses than with the other colors except light yellow. Under early evening conditions and during sports activities, light yellow lenses do not appear to have an adverse effect on visual attributes.

2019 ◽  
Vol 43 (1) ◽  
pp. 50
Author(s):  
Aquirina Caesari Putri ◽  
Rozalina Loebis

Background: Pediatric cataracts are major causes of children’s blindness. Surgery has proven to be beneficial in terms of visual function prognosis. Contrast sensitivity evaluation after surgery is as important as visual acuity considering that natural world consists of various objects in low-to-medium contrasts. The purpose of this study is to analyze the difference of contrast sensitivity outcomes based on ages at surgery. Method: Retrospective data of children with pediatric developmental cataract from July 2013 to November 2015 were collected. All children who underwent cataract surgery at 60-months-old or less were randomized into two groups, ≤24 months and >24-to-60 months. Contrast sensitivity was then examined with preferential-looking method using Hiding Heidi low-contrast test face chart. The main outcome measures were contrast sensitivity of both groups. Age-at-evaluation, cataract onset, duration of follow-up, duration of deprivation and visual acuity were also noted. Result: Of 14 children (23 eyes), 11 eyes (47,8%) were in ≤24 months group, 12eyes (52,2%) were in >24-to-60 months group. All eyes underwent cataract extraction and similar type of intraocular lens implantation. Mean age-at-surgery was 28,2 months±16,8 (SD). Mean contrast sensitivity for each group was 47,50 %±42,29 and 18,33%±27,38, respectively, with p-value 0,031. Further analysis of Spearman’s correlation test demonstrated significant negative correlation (rs = -0,559; p = 0,006) between the two groups. Conclusion: There was statistically significant difference in contrast sensitivity between those who underwent surgery at ≤24 months and >24-to-60 months. Children who underwent surgery at older ages tend to have better contrast sensitivity afterwards.


2021 ◽  
Vol 14 (12) ◽  
pp. 1876-1881
Author(s):  
Merve Bozkurt Gencer ◽  
◽  
Erdogan Yasar ◽  
Ozkan Onal ◽  
◽  
...  

AIM: To investigate and compare the quality of life, satisfaction, contrast sensitivity, glare, depth perception, and intraocular lens (IOL) rotation in patients who underwent trifocal toric and bifocal toric IOLs. METHODS: A total of 80 eyes of 40 patients were included in this prospective study. Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL, respectively. Preoperative and postoperative 6-month measurements were recorded for both patient groups. Comprehensive anterior and posterior segment examinations, distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations. Patient satisfaction, contrast sensitivity, glare, intermediate-near and distance stereopsis and IOL rotation were also evaluated. RESULTS: No significant difference was found between the groups in terms of distance and near visual acuities (P=0.269, P=0.451). Intermediate visual acuity was significantly increased in the trifocal toric group (P<0.001). The visual function scale results were increased after surgery in both groups (P=0.001 and P<0.001), with no difference determined between them (P=0.158 and P=0.691). The number of patients wearing glasses was low in both groups and there was no significant difference between the groups (P>0.05). The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group (P=0.03). The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions (1.80±0.24 logU, 1.74±0.20 logU). Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group (P=0.02, 0.048, 0.003, respectively). Although there was no significant difference for 3 meters stereopsis, the trifocal toric group had higher depth perception (P=0.577). Mean rotation was 5.76°±3.93° in the trifocal toric group and 12°±7.1° in the bifocal toric group. CONCLUSION: Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery. Moreover, the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group.


2017 ◽  
Vol 24 (8) ◽  
pp. 1126-1130 ◽  
Author(s):  
Neda Sattarnezhad ◽  
Samantha Farrow ◽  
Dorlan Kimbrough ◽  
Bonnie Glanz ◽  
Brian Healy ◽  
...  

Background: Visual symptoms are common in multiple sclerosis (MS). Low-contrast visual acuity (LCVA) testing using Sloan charts has demonstrated increased sensitivity for visual deficits compared to high-contrast acuity testing. Computerized testing of visual acuity may facilitate use in the clinic setting. Objectives: To evaluate the agreement between an iPad-based and Sloan testing of LCVA in a cohort of MS patients. Methods: A total of 38 patients with relapsing-remitting MS were enrolled after providing informed written consent at Partners MS Center, Brigham and Women’s hospital. Monocular LCVA was measured using retroilluminated Sloan chart and iPad-based LogMAR chart. Number of correct letters and agreement between two measurements were assessed for each eye using Bland–Altman analysis and paired t-test. Results: For both eyes, there was no significant difference in number correct between the two measurements using a paired t-test, and there was high correlation between two measurements (oculus dextrus (OD) r = 0.89, p < 0.001; oculus sinister (OS) r = 0.78, p < 0.001). The limits of agreement were −7.9 to +8.5 letters for the right eye and −10.9 to +11.2 letters for the left eye. Conclusion: An iPad-based LCVA test shows good agreement with Sloan testing in MS patients.


2020 ◽  
Vol 20 (2) ◽  
pp. 758-767
Author(s):  
Siddeeqa Jhetam ◽  
Khathutshelo P Mashige

Purpose: To investigate the effects of spectacle and telescope corrections on visual acuity (VA), contrast sensitivity (CS) and reading rates (RR) in students with oculocutaneous albinism (OCA). Methods: An observational study design was conducted on 81 students with OCA. Distance and near VA, CS and RR were measured without correction, with spectacle correction and with a combination of spectacle correction and telescopes. Results: The mean distance and near VA values with a combination of spectacle correction and telescopes were significantly better than those without correction and with spectacle correction alone (p = 0.01). Mean CS values achieved with spectacles alone were significantly better than those obtained with a combination of spectacles and telescopes (p = 0.01). There was no significant difference between logCS values obtained without correction compared to those obtained with a combination of spectacle correction and telescopes. There were no significant differences between RR values obtained with a combination of spectacles and telescopes and those without and with spectacle correction alone (all p > 0.05). Conclusion: This article provides valuable information to eye care practitioners on the effects of spectacles and telescopes on visual acuity, contrast sensitivity and reading rate in students with OCA. Keywords: Oculocutaneous albinism; visual acuity; telescope; contrast sensitivity; reading rate.


2021 ◽  
Vol 14 (3) ◽  
pp. 356-365
Author(s):  
Farideh Doroodgar ◽  
◽  
Azad Sanginabadi ◽  
Farid Karimian ◽  
Sana Niazi ◽  
...  

AIM: To compare the clinical outcomes of a variety of multifocal intraocular lenses (MIOLs) in patients diagnosed with presbyopia or cataracts. METHODS: This clinical trial study included 141 patients (282 eyes) with different MIOLs implantation. The Symfony (60 eyes), the ReSTOR (100 eyes), the AT LISAtri (60 eyes), and the PanOptix (62 eyes) intraocular lenses were evaluated in this prospective interventional study. The near, intermediate, and distant visual acuities, contrast sensitivity, and defocus curve were measured as valid criteria. To statistically analyze the results, we used the Statistical Package for Social Science software, the non-parametric Wilcoxon signed-rank t, the one-way analysis of variance and the Tukey's post-hoc test in our analysis. Moreover, we conducted a detailed literature search on the PubMed database in English about MIOLs, in total 59 studies were included in this review article. RESULTS: The four approaches did not show any significant difference in the best-corrected distance visual acuity (P>0.05). The defocus curves at the contrast of 100% showed that trifocal IOLs had better intermediate performance than the bifocal IOL (P<0.05). There were no statistically significant differences between AT LISAtri and PanOptix lenses for visual acuity at all distances. The eyes with PanOptix, Symfony, and AT LISAtri IOL showed better contrast sensitivity than those ReSTOR at spatial frequencies of 1, 3, and 6 cpd in photopic and mesopic conditions (P<0.001). CONCLUSION: All four groups of the multifocal lenses were satisfying in terms of distance and near vision. Also, the group of trifocal lenses led to satisfactory outcomes in intermediate vision, without degradation in quality of vision.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
G. Carracedo ◽  
T. M. Espinosa-Vidal ◽  
I. Martínez-Alberquilla ◽  
L. Batres

Purpose. To evaluate the effect of the optical zone diameter (OZ) in orthokeratology contact lenses regarding the topographical profile in patients with high myopia (−4.00 D to −7.00 D) and to study its effect over the visual quality. Materials and Methods. Twelve patients (18 eyes) were fitted with overnight orthokeratology (OrthoK) with a randomized 6 mm or 5 mm OZ lens worn for 2 weeks, followed by a 2-week washout period, between both designs. Keratometry (K) readings, optical zone treatment diameter (OZT), peripheral ring width (PRW), higher-order aberrations (HOA), high (HC) and low contrast (LC) visual acuity, and subjective vision and comfort were measured at baseline and after 2 weeks of OrthoK lens wear of each contact lens. Results. No significant differences were found between any measurements for the same subject at both baselines (p value > 0.05). There was no difference between OZ lens designs found in refraction, subjective vision or comfort, and HC and LC visual acuity. Contrast sensitivity was decreased in the 5 mm OZ lens design compared with 6 mm OZ design (p-value < 0.05). 5 mm OZ design provoked a greater flattening, more powerful midperipheral ring and 4th-order corneal and total spherical aberration than the 6 mm OZ design, being statistically significant after 7 days, for corneal aberration, and 15 days, for corneal and total, of wearing the lens (p-value < 0.05). The OZT obtained were 2.8 ± 0.2 mm and 3.1 ± 0.1 mm for 5 mm and 6 mm OZ design, respectively (p-value < 0.05). Regarding PRW, the 5 mm OZ design had a wider ring width in both the nasal and temporal zones (p-value < 0.05). Conclusions. A smaller diameter optical zone (5 mm) in orthokeratology lenses produces a smaller treatment area and a larger and more powerful midperipheral ring, increasing the 4th-order spherical aberration that affects only the contrast sensitivity but without differences in visual acuity and subjective vision compared with a larger OZ diameter (6 mm).


2021 ◽  
Vol 2 (4) ◽  
pp. 228-232
Author(s):  
Kumar Aalok ◽  

AIM: To study the effects of blunt trauma of eye on visual acuity and retinal nerve fiber layer (RNFL). METHODS: A prospective observational study was done on the patients of a road traffic accident (RTA) having blunt trauma injury of the eye from august 2018 to July 2019 at the Department of Ophthalmology, Hind Institute of Medical Sciences, Barabanki. Patients between the age group of 20 to 65 years undergoing RTA with ocular complaints were included in this study. Colour vision, contrast sensitivity, and best-corrected visual acuity (BCVA) were recorded, RNFL analysis was done through OCT. RESULTS: A total of 108 patients were enrolled in this study and were grouped as 54 cases and 54 controls. The mean age was 43±2.3 years with 11 (20.37%) females and 43 (79.6%) males in the case group. At initial visit after RTA, the difference between color vision, contrast sensitivity and BCVA between right and left eyes of cases and controls were significant. After a follow up of 3mo only significant difference was noted in contrast sensitivity between cases and control groups. Change in color vision and BCVA after 3mo was insignificant. Similarly, an initial significant difference was noted in mean RNFL thickness between cases and control groups, but after follow up of 3mo mean RNFL thickness difference was significant only in superior and temporal quadrants. CONCLUSION: RTA or blunt trauma of eye can lead to persistent RNFL thinning and decreased visual function.


1987 ◽  
Vol 31 (11) ◽  
pp. 1194-1197 ◽  
Author(s):  
David Shinar ◽  
Ehud Gilead

A class of undergraduate students were screened for their visual acuity and contrast sensitivity on Ginsburg's charts. The subjects obtaining the highest and lowest contrast sensitivity scores were further tested on their complex target detection time. The complex targets consisted of a tank or a human form against a background of a mountainous terrain. The main finding was that target detection time for the high contrast sensitivity subjects was less than half of that of the low contrast sensitivity subjects. Differences in visual acuity between the two groups did not explain the differences in reaction time.


2011 ◽  
Vol 21 (6) ◽  
pp. 732-740
Author(s):  
Yanwen Fang ◽  
Yi Lu ◽  
Xinhua Wu ◽  
Aizhu Miao ◽  
Yi Luo

Purpose. To evaluate and compare the objective and subjective visual function after implantation of 2 aspheric intraocular lenses (IOLs) in Chinese cataract patients. Methods. Forty-one eyes of 28 patients with cataract were randomly assigned to receive either the MC X11 ASP IOL or the AcrySof IQ IOL. Three months postoperatively, best-corrected visual acuity (BCVA), contrast sensitivity, wavefront aberrations, and subjective visual quality were measured. The degree of posterior capsule opacification (PCO) was recorded at last follow-up. Results. Postoperative mean monocular BCVA was 0.05±0.13 logMAR in the MC X11 group and 0.05±0.08 logMAR in the IQ group. There was no significant difference in visual acuity, contrast sensitivity, subjective visual quality, and degree of PCO between the 2 groups. For a 6-mm pupil diameter, the mean spherical aberration (Z40) was 0.075±0.076 μm in the MC X11 group and 0.056±0.111 μm in the IQ group. However, 45.5% and 57.9% of the eyes in the MC X11 and IQ groups had values >0.10 μm, respectively. The mean RMS values of the high-order aberrations were similar between the 2 groups except the higher fifth- and sixth-order aberrations, which were significantly higher in the MC X11 group. Conclusions. Both IOLs provided similar and good visual outcomes. However, the data suggest that the amount of negative spherical aberration generated by current available aspheric IOLs might not be optimal for Chinese eyes.


Sign in / Sign up

Export Citation Format

Share Document