scholarly journals The Effects of Different Shaped Baffle Blocks on the Energy Dissipation

2020 ◽  
Vol 6 (5) ◽  
pp. 961-973
Author(s):  
Nassrin Jassim Hussien Al-Mansori ◽  
Thair Jabbar Mizhir Alfatlawi ◽  
Khalid S. Hashim ◽  
Laith S. Al-Zubaidi

Stilling basins can be defined as energy dissipaters constructed of the irrigation systems. This study aims at investigating the performance of the new seven baffle blocks design in terms of reducing the dimensions of stilling basins in irrigation systems. In order to assess the hydraulic efficiency of a new model for baffle block used in stilling basins, a Naval Research Laboratory (NRL) has conducted. The results of this study demonstrate that the performance of the new baffle block, in term of hydraulic jump length reduction and hydraulic energy dissipation, it's better than standard blocks. However, the ratios of the drag resistance attributed to the new baffles block (FB / F2) have been larger than that applied on the normal block. It was found that the new block dissipates the energy by 9.31% more than the concrete block, and decreases the length of the hydraulic jump by 38.6% in comparison with the standard blocks. However, the new block maximizes the drag force ratio by 98.6% in comparison with the standard baffle blocks. The findings indicated that in terms of energy reduction and dissipation in the length of the hydraulic jump, the new block is superior to the other kinds.

2020 ◽  
Vol 29 (4) ◽  
pp. 409-420
Author(s):  
Thair Al-Fatlawi ◽  
Nassrin Al-Mansori ◽  
Nariman Othman

When designing dam spillway structures, the most significant consideration is the energy dissipation arrangements. Different varieties of baffle blocks and stilling basins have been used in this context. However, the hydraulic jump form of stilling basin is considered to be the most suitable. The main objective of this research was to introduce four different baffle block shapes (models arranged from A to D, installed at slopes 0.00, 0.04, 0.06 and 0.08 in the stilling basins). To illustrate the consequences for the qualities of pressure-driven bounce, each model was attempted in the bowl. The trials applied Froude numbers between 6.5 and 9.2. The puzzle square model D provided the best outcomes compared to the models A, B, C and smooth. Model D with different models at inclines 0.00, 0.04, 0.06 and 0.08 was used to consider the impacts of perplex hinders on water driven-bounce when bed slants were changed. When the model D baffle used instead of a smooth bed at 0.08 slope, the reduction in y2 / y1 reached 12.8%, and Lj / y1 was 18.9%. Among the different bed slopes, a normal decrease in y2 / y1 ranged from approximately 10.3%, whereas the normal decrease in Lj / y1 was about 13.8% when the model D baffle was used instead of the model A baffle with a horizontal slope bed of 0.00. The results show that the new shapes led to a decrease in sequent profundity proportion and length of jump proportion; however, the energy dissipation proportion increased.


2018 ◽  
Vol 162 ◽  
pp. 03005
Author(s):  
Ali Abbas ◽  
Haider Alwash ◽  
Ali Mahmood

The construction of stilling basin with adverse slope change the characteristics of hydraulic jump such as sequent depth ratio, length of jump ratio, length of roller and energy dissipation ratio, consequently the dimensions of stilling basin are changed, also using baffle blocks with different configurations develop these characteristics. In this study different shapes of baffle block (models (A), (B), (C) and (D)) installed in the stilling basins at adverse slopes (- 0.03, - 0.045, - 0.06) in addition to horizontal bed, all these models are tested in the stilling basin to show their effects on the characteristics of hydraulic jump, the experiments applied for the range of Froude number (Fr1) between 3.99 and 7.48. The baffle block model (D) showed good results when compared with models (B) and (C), therefore it used with arrangement of (single and double row) and compared with baffle block model (A) at slopes (0, - 0.03, - 0.045, - 0.06) to study the effects of baffle blocks on hydraulic jump when bed slopes are changed. In general using baffle block caused a reduction in sequent depth ratio, length of jump ratio and the length of the roller, but the energy dissipation ratio increased.


Water ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1758
Author(s):  
Juan Macián-Pérez ◽  
Francisco Vallés-Morán ◽  
Santiago Sánchez-Gómez ◽  
Marco De-Rossi-Estrada ◽  
Rafael García-Bartual

The study of the hydraulic jump developed in stilling basins is complex to a high degree due to the intense velocity and pressure fluctuations and the significant air entrainment. It is this complexity, bound to the practical interest in stilling basins for energy dissipation purposes, which brings the importance of physical modeling into the spotlight. However, despite the importance of stilling basins in engineering, bibliographic studies have traditionally focused on the classical hydraulic jump. Therefore, the objective of this research was to study the characteristics of the hydraulic jump in a typified USBR II stilling basin, through a physical model. The free surface profile and the velocity distribution of the hydraulic jump developed within this structure were analyzed in the model. To this end, an experimental campaign was carried out, assessing the performance of both, innovative techniques such as the time-of-flight camera and traditional instrumentation like the Pitot tube. The results showed a satisfactory representation of the free surface profile and the velocity distribution, despite some discussed limitations. Furthermore, the instrumentation employed revealed the important influence of the energy dissipation devices on the flow properties. In particular, relevant differences were found for the hydraulic jump shape and the maximum velocity positions within the measured vertical profiles, when compared to classical hydraulic jumps.


Water ◽  
2019 ◽  
Vol 11 (10) ◽  
pp. 1971
Author(s):  
Afzal Ahmed ◽  
Abdul Razzaq Ghumman

In this study, a series of laboratory experiments were conducted to investigate the energy loss through the hybrid defense system (HDS) in the order of dike, moat, and emergent vegetation in steady subcritical flow conditions. The results of HDS were compared with a single defense system (SDS) comprising only vegetation (OV). The dimensions of dike were kept constant while two different shapes (trapezoidal and rectangular) of moat were considered. The impacts of vegetation of variable thickness and density were investigated. Two combinations of HDS were investigated including the combination of dike and vegetation (DV) and the combination of dike, moat, and vegetation (DMV). The effect of backwater rise due to the vegetation, hydraulic jump formation and the impact of the arrival time of floodwater on energy dissipation were investigated. It was observed that on the upstream side of obstructions, the backwater depth increased by increasing the Froude number in both the SDS and HDS. The hydraulic jump observed in HDS was classified and the energy dissipation due to it was calculated. Under various conditions investigated in this paper, the maximum average energy dissipation was 32% in SDS and 46% in HDS. The trapezoidal moat performed better than rectangular moat as energy dissipater. The delay time was also greater with trapezoidal moat as compared to that in rectangular one. The maximum delay time was 140 s in the case of HDS. Hence, the hybrid defense system offered maximum resistance to the flow of water, thus causing a significant energy loss. For each case of SDS and HDS, empirical equations were developed by regression analysis to estimate the energy dissipation amounts.


Author(s):  
Rollin H. Hotchkiss ◽  
Emily A. Larson ◽  
David M. Admiraal

Riprap and concrete stilling basins are often built at culvert outlets to keep high-energy flows from scouring the streambed. Two simple alternatives to large basins are examined: a horizontal apron with an end weir and a drop structure with an end weir. The two designs are intended to reduce the flow energy at the outlet by inducing a hydraulic jump within the culvert barrel without the aid of tailwater. This research examines the jump geometry and the effectiveness of each jump type and proposes a design procedure for practicing engineers. The design procedure is applicable to culverts with approach Froude numbers from 2.6 to 6.0. Both designs are effective in reducing outlet velocity 0.7 to 8.5 ft/s (0.21 to 2.59 m/s), momentum 10% to 48%, and energy 6% to 71%. The design layouts allow easy access for maintenance activities.


2018 ◽  
Vol 11 (3) ◽  
pp. 7-13 ◽  
Author(s):  
Ali Sadik Abbas

The effect of changing in the bed slope of stilling basins produces changing in characteristics of the hydraulic jump such as sequent depth ratio, length of jump ratio, length of the roller and energy dissipation ratio, consequently the dimensions of stilling basin changed. In this study hydraulic jump investigated on smooth bed (without any appurtenances) for three adverse slopes (- 0.03, - 0.045, - 0.06) in addition to horizontal bed slope, the experiments were applied for the range of Froude number (Fr1) between 3.99 and 7.48. The results showed a reduction about10 % in sequent depth ratio, 22.1 % in length of jump ratio, 20.51 % in length of roller ratio and 13.87% in the energy dissipation ratio when the adverse slope (- 0.06) used instead of horizontal bed for the same Froude numbers. Empirical equations for the sequent depth ratio, length of roller ratio and the energy dissipation ratio were obtained from the experimental data


Open Physics ◽  
2020 ◽  
Vol 18 (1) ◽  
pp. 631-641
Author(s):  
Shujuan Yang

AbstractIn view of the problem of large earthquake displacement in the use of the original concrete engineering shear wall reinforcement method, the energy dissipation and damping structure is used to design the energy dissipation and damping structure reinforcement method in the concrete engineering shear wall. According to the design process of the set method, the anti-vibration coefficient of the concrete shear wall is tested. The energy dissipation structure is used to construct a shear damping wall, and the damper is added to the original shear wall. The concrete shear wall is strengthened by sticking steel technology. So far, the design of shear wall reinforcement method based on the energy dissipation structure has been completed. Compared with the original method, the displacement distance of this method is lower than that of the original method. In conclusion, the effect of shear wall reinforcement method based on the energy dissipation structure is better than that of the original method.


2018 ◽  
Vol 22 (6) ◽  
pp. 1312-1328 ◽  
Author(s):  
Jianyang Xue ◽  
Rui Guo ◽  
Liangjie Qi ◽  
Dan Xu

The majority of existing ancient timber structures have different degrees of damage. The looseness of mortise-tenon joints is a kind of typical damage type. In order to study the influence of looseness on the seismic performance of mortise-tenon joints, six through-tenon joints and six dovetail-tenon joints with scale 1:3.2 were fabricated according to the requirements of the engineering fabrication method of Chinese Qing Dynasty. Each type of joints consisted of one intact joint and five artificial loose joints, and the artificial defect was made to simulate looseness by cutting the tenon sectional dimension. Based on experiments of two types of joints under low-cyclic reversed loading, the seismic behaviors of joints such as failure modes, hysteretic loops and skeleton curves, strength and stiffness degradation, and energy dissipation capacity were studied. Moreover, the comparative analyses of seismic performance between two types of joints were carried out. The variation tendency of seismic behaviors of two types of joints has similarities, and there are some differences due to their different structural styles. The results indicate that squeeze deformation between tenon and mortise of two types of joints occurred. The shape of hysteretic loops of two types of joints is reverse-Z-shape, and the pinching effect of hysteretic loops becomes more obvious with the increase in looseness, among which of through-tenon joints is more obvious than that of dovetail-tenon joints. The carrying capacity, stiffness, and energy dissipation capacity of loose joints are significantly lower than that of the intact one, and the energy dissipation capacity of dovetail-tenon joints is better than that of through-tenon joints. The rotation angles of two types of joints can reach 0.12 rad, and the loose joints still have great deformation capacity.


Sign in / Sign up

Export Citation Format

Share Document