scholarly journals Method for increasing noise immunity of radar "friend or foe" identification systems under the action of intentional correlated interference

Radiotekhnika ◽  
2021 ◽  
pp. 154-160
Author(s):  
I.V. Svyd ◽  
I.I. Obod ◽  
O.S. Maltsev ◽  
M.G. Tkach ◽  
S.V. Starokozhev ◽  
...  

The paper analyzes the principles of construction and structure of "friend or foe" identification systems. It is revealed, that the party, interested in the existing system, has the ability of unauthorized use of this information resource for long-range determination of air objects coordinates, on the one hand, and distortion of information of this information resource, on the other hand, which leads to unpredictable consequences. It is shown, that the most vulnerable place in the "friend or foe" identification systems is the aircraft transponder, which significantly affects noise stability and noise immunity of the identification systems of air objects. The paper proposes a method of hereditary transition to noise-immune "friend or foe" identification systems based on synchronous networks of identification systems, which allows expanding significantly the methods of servicing requests and methods of constructing systems. This method of constructing identification systems eliminates the existing problem of dispersed identification systems, as well as the problem of temporal matching of signals coming from primary and secondary radar systems. The proposed method of hereditary transition to noise-immune "friend or foe" identification systems makes it possible to exclude the possibility of unauthorized access to identification information resources by an interested party, significantly increases the noise immunity of the identification system as a whole.

1967 ◽  
Vol 18 (01/02) ◽  
pp. 198-210 ◽  
Author(s):  
Ronald S Reno ◽  
Walter H Seegers

SummaryA two-stage assay procedure was developed for the determination of the autoprothrombin C titre which can be developed from prothrombin or autoprothrombin III containing solutions. The proenzyme is activated by Russell’s viper venom and the autoprothrombin C activity that appears is measured by its ability to shorten the partial thromboplastin time of bovine plasma.Using the assay, the autoprothrombin C titre was determined in the plasma of several species, as well as the percentage of it remaining in the serum from blood clotted in glass test tubes. Much autoprothrombin III remains in human serum. With sufficient thromboplastin it was completely utilized. Plasma from selected patients with coagulation disorders was assayed and only Stuart plasma was abnormal. In so-called factor VII, IX, and P.T.A. deficiency the autoprothrombin C titre and thrombin titre that could be developed was normal. In one case (prethrombin irregularity) practically no thrombin titre developed but the amount of autoprothrombin C which generated was in the normal range.Dogs were treated with Dicumarol and the autoprothrombin C titre that could be developed from their plasmas decreased until only traces could be detected. This coincided with a lowering of the thrombin titre that could be developed and a prolongation of the one-stage prothrombin time. While the Dicumarol was acting, the dogs were given an infusion of purified bovine prothrombin and the levels of autoprothrombin C, thrombin and one-stage prothrombin time were followed for several hours. The tests became normal immediately after the infusion and then went back to preinfusion levels over a period of 24 hrs.In other dogs the effect of Dicumarol was reversed by giving vitamin K1 intravenously. The effect of the vitamin was noticed as early as 20 min after administration.In response to vitamin K the most pronounced increase was with that portion of the prothrombin molecule which yields thrombin. The proportion of that protein with respect to the precursor of autoprothrombin C increased during the first hour and then started to go down and after 3 hrs was equal to the proportion normally found in plasma.


1969 ◽  
Vol 61 (2) ◽  
pp. 219-231 ◽  
Author(s):  
V. H. Asfeldt

ABSTRACT This is an investigation of the practical clinical value of the one mg dexamethasone suppression test of Nugent et al. (1963). The results, evaluated from the decrease in fluorimetrically determined plasma corticosteroids in normal subjects, as well as in cases of exogenous obesity, hirsutism and in Cushing's syndrome, confirm the findings reported in previous studies. Plasma corticosteroid reduction after one mg of dexamethasone in cases of stable diabetes was not significantly different from that observed in control subjects, but in one third of the insulin-treated diabetics only a partial response was observed, indicating a slight hypercorticism in these patients. An insufficient decrease in plasma corticosteroids was observed in certain other conditions (anorexia nervosa, pituitary adenoma, patients receiving contraceptive or anticonvulsive treatment) with no hypercorticism. The physiological significance of these findings is discussed. It is concluded that the test, together with a determination of the basal urinary 17-ketogenic steroid excretion, is suitable as the first diagnostic test in patients in whom Cushing's syndrome is suspected. In cases of insufficient suppression of plasma corticosteroids, further studies, including the suppression test of Liddle (1960), must be carried out.


2020 ◽  
Vol 17 ◽  
Author(s):  
Houli Li ◽  
Di Zhang ◽  
Xiaoliang Cheng ◽  
Qiaowei Zheng ◽  
Kai Cheng ◽  
...  

Background: The trough concentration (Cmin) of Imatinib (IM) is closely related to the treatment outcomes and adverse reactions of patients with gastrointestinal stromal tumors (GIST). However, the drug plasma level has great interand intra-individual variability, and therapeutic drug monitoring (TDM) is highly recommended. Objective: To develop a novel, simple, and economical two-dimensional liquid chromatography method with ultraviolet detector (2D-LC-UV) for simultaneous determination of IM and its major active metabolite, N-demethyl imatinib (NDIM) in human plasma, and then apply the method for TDM of the drug. Method: Sample was processed by simple protein precipitation. Two target analytes were separated on the one-dimension column, captured on the middle column, and then transferred to the two-dimension column for further analysis. The detection was performed at 264 nm. The column temperature was maintained at 40˚C and the injection volume was 500 μL. Totally 32 plasma samples were obtained from patients with GIST who were receiving IM. Method: Sample was processed by simple protein precipitation. Two target analytes were separated on the one-dimension column, captured on the middle column, and then transferred to the two-dimension column for further analysis. The detection was performed at 264 nm. The column temperature was maintained at 40˚C and the injection volume was 500 μL. Totally 32 plasma samples were obtained from patients with GIST who were receiving IM. Conclusion: The novel 2D-LC-UV method is simple, stable, highly automated and independent of specialized technicians, which greatly increases the real-time capability of routine TDM for IM in hospital.


Author(s):  
A. V. Mazin ◽  
M. Yu. Aliyev

The article investigates the problem of providing high noise immunity radar under the influence of passive and intentional interference. The purpose of radio operation of the radar is to create conditions that would impede the operation of systems and minimize its effectiveness. The main method of radio transmission is still creating (staging) interference. Modern radar systems must solve the tasks in terms of electronic suppression using, including intentional interference and under severe time constraints. It is shown that the most effective way to improve the noise immunity of radar systems designed to operate in multipoint space, including non-stationary, interference is adaptive space-time processing of the received signals, based on the angular selection of targets, due to the formation of zeros in the directional diagram in the direction of interference sources. This problem is solved by determining the accuracy of the direction finding of interference sources and is achieved by the joint operation of the antenna array and multi-channel signal processing devices, namely the separation of interference signals on different receiving channels.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4842
Author(s):  
Waldemar Kamiński

Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the controlled points (CPs). The reference sensor is the one that is placed at the point that (in theoretical assumptions) is not a subject to vertical displacements and the displacements of controlled points are determined according to its height. The hydrostatic levelling rule comes from the Bernoulli’s law. While using the Bernoulli’s principle in hydrostatic levelling, the following components have to be taken into account: atmospheric pressure, force of gravity, density of liquid used in sensors places at CPs. The parameters mentioned above are determined with some mean errors that influence on the accuracy assessment of vertical displacements. In the subject’s literature, there are some works describing the individual accuracy analyses of the components mentioned above. In this paper, the author proposes the concept of comprehensive determination of mean error of vertical displacement (of each CPs), calculated from the mean errors’ values of components dedicated for specific HLS. The formulas of covariances’ matrix were derived and they enable to make the accuracy assessment of the calculations’ results. The author also presented the subject of modelling of vertical displacements’ gained values. The dependences, enabling to conduct the statistic tests of received model’s parameters, were implemented. The conducted tests make it possible to verify the correctness of used theoretical models of the examined object treated as the rigid body. The practical analyses were conducted for two simulated variants of sensors’ connections in HLS. Variant no. I is the sensors’ serial connection. Variant no. II relies on the connection of each CPs with the reference sensor. The calculations’ results show that more detailed value estimations of the vertical displacements can be obtained using variant no. II.


1975 ◽  
Vol 68 ◽  
pp. 239-241
Author(s):  
John C. Brown ◽  
H. F. Van Beek

SummaryThe importance and difficulties of determining the height of hard X-ray sources in the solar atmosphere, in order to distinguish source models, have been discussed by Brown and McClymont (1974) and also in this Symposium (Brown, 1975; Datlowe, 1975). Theoretical predictions of this height, h, range between and 105 km above the photosphere for different models (Brown and McClymont, 1974; McClymont and Brown, 1974). Equally diverse values have been inferred from observations of synchronous chromospheric EUV bursts (Kane and Donnelly, 1971) on the one hand and from apparently behind-the-limb events (e.g. Datlowe, 1975) on the other.


2009 ◽  
Vol 39 (1) ◽  
pp. 339-370 ◽  
Author(s):  
Robert J. Thomson ◽  
Dmitri V. Gott

AbstractIn this paper, a long-term equilibrium model of a local market is developed. Subject to minor qualifications, the model is arbitrage-free. The variables modelled are the prices of risk-free zero-coupon bonds – both index-linked and conventional – and of equities, as well as the inflation rate. The model is developed in discrete (nominally annual) time, but allowance is made for processes in continuous time subject to continuous rebalancing. It is based on a model of the market portfolio comprising all the above-mentioned asset categories. The risk-free asset is taken to be the one-year index-linked bond. It is assumed that, conditionally upon information at the beginning of a year, market participants have homogeneous expectations with regard to the forthcoming year and make their decisions in mean-variance space. For the purposes of illustration, a descriptive version of the model is developed with reference to UK data. The parameters produced by that process may be used to inform the determination of those required for the use of the model as a predictive model. Illustrative results of simulations of the model are given.


Sign in / Sign up

Export Citation Format

Share Document