Role of Immunofluorescence and Electron Microscopy in the Evaluation of Renal Biopsies in Nephrotic Syndrome in a Developing Country

2009 ◽  
Vol 33 (6) ◽  
pp. 260-264 ◽  
Author(s):  
Muhammed Mubarak ◽  
Javed Iqbal Kazi
2009 ◽  
Vol 133 (2) ◽  
pp. 283-288 ◽  
Author(s):  
Anjali A. Satoskar ◽  
Edward Calomeni ◽  
Cherri Bott ◽  
Gyongyi M. Nadasdy ◽  
Tibor Nadasdy

Abstract Context.—Consensus exists among renal pathologists that, in biopsies with immune complex glomerulonephritis, even a single glomerulus with open capillary loops may be sufficient for immunofluorescence and/or electron microscopy evaluation because immune complex deposition is a diffuse phenomenon. However, we have encountered renal biopsies with focal absence of immune complexes in glomeruli on either immunofluorescence or electron microscopy examination despite presence of open glomerular capillary loops. Objective.—To evaluate renal biopsies with focal immune complex deposition and look for any subtle or unusual morphologic changes in the glomeruli (and in the biopsy in general). Design.—Native and transplant renal biopsies were reviewed. All biopsies had been triaged and processed according to our routine protocol for light microscopy, immunofluorescence, and electron microscopy examination. Results.—Of 2018 renal biopsies from December 2005 to December 2007, we found 10 such biopsies; 5 native and 5 transplant kidney biopsies. We found that the glomeruli with absent immune complex deposits had periglomerular fibrosis with open, albeit, wrinkled appearing capillary loops but no glomerular sclerosis. Conclusions.—We hypothesize that these histologic features are indicative of nonfunctional glomeruli and may be associated with disconnection between the Bowman capsule and proximal tubule (atubular glomeruli). These glomeruli may not have effective filtration, despite some degree of circulation through the open capillary loops, and therefore are unable to accumulate immune complex deposits. If biopsies are small and only such glomeruli are available for immunofluorescence or electron microscopy examination, the absence of immune complex deposition in them should be evaluated carefully.


2017 ◽  
Vol 4 (6) ◽  
pp. A705-A713
Author(s):  
Ganesh Ramdas Kshirsagar ◽  
NitinMaheswar Gadgil ◽  
SangeetaRamulu Margam ◽  
ChetanSudhakar Chaudhari ◽  
Prashant Vijay Kumavat ◽  
...  

2004 ◽  
Vol 122 (3) ◽  
pp. 104-109 ◽  
Author(s):  
Angelo Sementilli ◽  
Luiz Antonio Moura ◽  
Marcello Fabiano Franco

CONTEXT: Electron microscopy has been used for the morphological diagnosis of glomerular diseases for more than three decades and its value has been widely emphasized. However, recent reports have analyzed the routine use of electron microscopy critically. Its use in other areas of diagnosis such as tumor diseases has declined considerably; in addition, in view of the unavoidable financial pressure for the reduction of costs due to investigations and diagnostic routines, the selection of cases for electron microscopy has been quite rigorous. OBJECTIVE: To identify the glomerular diseases that depend on electron microscopy for a final diagnosis, by means of reviewing renal biopsies performed over a 12-year period. DESIGN: Prospective SETTING: Hospital Ana Costa, Hospital Guilherme Álvaro and Serviço de Anatomia Patológica de Santos, Santos, São Paulo, Brazil. PARTICIPANTS: 200 consecutive renal biopsies obtained from private hospitals and the teaching hospital from 1979 to 1991 were studied. MAIN MEASUREMENTS: All cases were analyzed via light microscopy, immunofluorescence and electron microscopy. The diagnosis was first made via light microscopy plus immunofluorescence and then via electron microscopy. RESULTS: Electron microscopy was diagnostic or essential for diagnosis in 10.0% of the cases, corresponding to 3.4% of primary glomerulopathies and 100% of hereditary glomerulopathies. Electron microscopy was contributory (useful) to the diagnosis in 5.5% of the cases, confirming the preliminary diagnosis formulated on the basis of clinical and laboratory data and light microscopy plus immunofluorescence findings. We obtained a 7.5% rate of discordant immunofluorescence, which was considered as such when negative immunofluorescence findings were not confirmed by electron microscopy. The final diagnosis with the use of light microscopy plus immunofluorescence alone was 77.0%. CONCLUSIONS: It was possible to diagnose with certainty a great percentage of glomerulopathies (82.5-90% of the cases) based on the light microscopy and immunofluorescence findings alone. Electron microscopy was essential for the diagnosis of hereditary nephropathies.


Author(s):  
A. Lawley ◽  
M. R. Pinnel ◽  
A. Pattnaik

As part of a broad program on composite materials, the role of the interface on the micromechanics of deformation of metal-matrix composites is being studied. The approach is to correlate elastic behavior, micro and macroyielding, flow, and fracture behavior with associated structural detail (dislocation substructure, fracture characteristics) and stress-state. This provides an understanding of the mode of deformation from an atomistic viewpoint; a critical evaluation can then be made of existing models of composite behavior based on continuum mechanics. This paper covers the electron microscopy (transmission, fractography, scanning microscopy) of two distinct forms of composite material: conventional fiber-reinforced (aluminum-stainless steel) and directionally solidified eutectic alloys (aluminum-copper). In the former, the interface is in the form of a compound and/or solid solution whereas in directionally solidified alloys, the interface consists of a precise crystallographic boundary between the two constituents of the eutectic.


Author(s):  
Nalin J. Unakar

The increased number of lysosomes as well as the close approximation of lysosomes to the Golgi apparatus in tissue under variety of experimental conditions is commonly observed. These observations suggest Golgi involvement in lysosomal production. The role of the Golgi apparatus in the production of lysosomes in mouse liver was studied by electron microscopy of liver following toxic injury by CCI4.


Author(s):  
Benjamin F. Trump ◽  
Irene K. Berezesky ◽  
Raymond T. Jones

The role of electron microscopy and associated techniques is assured in diagnostic pathology. At the present time, most of the progress has been made on tissues examined by transmission electron microscopy (TEM) and correlated with light microscopy (LM) and by cytochemistry using both plastic and paraffin-embedded materials. As mentioned elsewhere in this symposium, this has revolutionized many fields of pathology including diagnostic, anatomic and clinical pathology. It began with the kidney; however, it has now been extended to most other organ systems and to tumor diagnosis in general. The results of the past few years tend to indicate the future directions and needs of this expanding field. Now, in addition to routine EM, pathologists have access to the many newly developed methods and instruments mentioned below which should aid considerably not only in diagnostic pathology but in investigative pathology as well.


Author(s):  
L. Tang ◽  
G. Thomas ◽  
M. R. Khan ◽  
S. L. Duan

Cr thin films are often used as underlayers for Co alloy magnetic thin films, such as Co1, CoNi2, and CoNiCr3, for high density longitudinal magnetic recording. It is belived that the role of the Cr underlayer is to control the growth and texture of the Co alloy magnetic thin films, and, then, to increase the in plane coercivity of the films. Although many epitaxial relationship between the Cr underlayer and the magnetic films, such as ﹛1010﹜Co/ {110﹜Cr4, ﹛2110﹜Co/ ﹛001﹜Cr5, ﹛0002﹜Co/﹛110﹜Cr6, have been suggested and appear to be related to the Cr thickness, the texture of the Cr underlayer itself is still not understood very well. In this study, the texture of a 2000 Å thick Cr underlayer on Nip/Al substrate for thin films of (Co75Ni25)1-xTix dc-sputtered with - 200 V substrate bias is investigated by electron microscopy.


Author(s):  
J. R. Michael ◽  
A. D. Romig ◽  
D. R. Frear

Al with additions of Cu is commonly used as the conductor metallizations for integrated circuits, the Cu being added since it improves resistance to electromigration failure. As linewidths decrease to submicrometer dimensions, the current density carried by the interconnect increases dramatically and the probability of electromigration failure increases. To increase the robustness of the interconnect lines to this failure mode, an understanding of the mechanism by which Cu improves resistance to electromigration is needed. A number of theories have been proposed to account for role of Cu on electromigration behavior and many of the theories are dependent of the elemental Cu distribution in the interconnect line. However, there is an incomplete understanding of the distribution of Cu within the Al interconnect as a function of thermal history. In order to understand the role of Cu in reducing electromigration failures better, it is important to characterize the Cu distribution within the microstructure of the Al-Cu metallization.


Author(s):  
Douglas William Jones

Within the past 20 years, archaeobotanical research in the Eastern United States has documented an early agricultural complex before the dominance of the Mesoamerican domesticates (corn, beans, and squash) in late prehistoric and historic agricultural systems. This early agricultural complex consisted of domesticated plants such as Iva annua var.macrocarpa (Sumpweed or Marshelder), Hellanthus annuus (Sunflower) and Chenopodium berlandieri, (Goosefoot or Lasbsquarters), and heavily utilized plants such as Polygonum erectum (Erect Knotweed), Phalaris caroliniana (May grass), and Hordeum pusillum (Little Barley).Recent research involving the use of Scanning Electron Microscopy (SEM) specifically on Chenopodium has established diagnostic traits of wild and domesticated species seeds. This is important because carbonized or uncarbonized seeds are the most commonly recovered Chenopodium material from archaeological sites. The diagnostic seed traits assist archaeobotanists in identification of Chenopodium remains and provide a basis for evaluation of Chenopodium utilization in a culture's subsistence patterns. With the aid of SEM, an analysis of Chenopodium remains from three Late Prehistoric sites in Northwest Iowa (Blood Run [Oneota culture], Brewster [Mill Creek culture], and Chan-Ya-Ta [Mill Creek culture]) has been conducted to: 1) attempt seed identification to a species level, 2) evaluate the traits of the seeds for classification as either wild or domesticated, and 3) evaluate the role of Chenopodium utilization in both the Oneota and Mill Creek cultures.


Sign in / Sign up

Export Citation Format

Share Document