scholarly journals Comparative Efficacy of Different Mastitis Markers for Diagnosis of Sub-Clinical Mastitis in Cows

2014 ◽  
Vol 2 (2) ◽  
pp. 121-125 ◽  
Author(s):  
Anil Langer ◽  
Sunanda Sharma ◽  
Narendra Kumar Sharma ◽  
DS Nauriyal

Seven hundred ninety six milk samples from 266 quarters of 69 lactating cows were subjected to microbiological investigations for identification of pathogens. One hundred ninety bacterial isolates were recovered from 89 infected quarters, among these monomicrobial infection was found in 50 (56.2%) quarters, whereas, mixed infection was observed in 39 (43.8%) quarters. Bacterial isolates identified were Staph. chromogenes (49.47%), Staph. hyicus (21.1%), Staph. epidermidis (11.05%), Str. agalactiae (5.8%), Staph. aureus (4.2%), Staph. intermedius (3.1%), Enterobacter sp. (1.5%), Klebsiella sp., E. coli (1.05%), Micrococcus sp. (1.05%) and Serratia marcescens (0.52%). Milk samples from every quarter of each cow were also subjected to 6 mastitis marker tests named Somatic cell count (SCC), California mastitis test (CMT), electrical conductivity (EC) by EC-meter as well as by Hand-held mastitis detector, pH detection by impregnated paper strip and also by pH meter. Efficacy of mastitis markers for diagnosis of sub-clinical mastitis was determined by comparing results of mastitis marker tests with microbiological findings. Mean value of SSC in milk from healthy quarters was significantly lower (p than that in milk from infected quarters. Significantly higher (p value of SSC was observed in milk samples having coagulase positive staphylococci as compared to that in milk from quarter with coagulase negative pathogens. The mean electrical conductivity (EC) in milk samples from infected quarters was significantly higher (P<0.05) than that from healthy quarters. Numbers and percentages of samples showing true positive, true negative, false positive and false negative results with SSC, CMT, EC by EC-meter, EC by hand-held meter, pH by impregnated strips, pH by digital pH-meter tests were evaluated and compared. The sensitivity and specificity of impregnated pH paper strip, CMT, pH-meter test, SCC, electrical conductivity by EC-meter and the same by Hand-held mastitis detector were evaluated The compatibility between the results of SCC, impregnated pH paper strip, CMT, EC-meter, pH-meter, Hand-held mastitis detector and bacteriological culture examination (reference test) was found to be 64.4, 63.4, 61.5, 59, 59 and 53 respectively.DOI: http://dx.doi.org/10.3126/ijasbt.v2i2.10191Int J Appl Sci Biotechnol, Vol. 2(2): 121-125

2020 ◽  
Vol 41 (4) ◽  
pp. 240-247
Author(s):  
Lei Yang ◽  
Qingtao Zhao ◽  
Shuyu Wang

Background: Serum periostin has been proposed as a noninvasive biomarker for asthma diagnosis and management. However, its accuracy for the diagnosis of asthma in different populations is not completely clear. Methods: This meta-analysis aimed to evaluate the diagnostic accuracy of periostin level in the clinical determination of asthma. Several medical literature data bases were searched for relevant studies through December 1, 2019. The numbers of patients with true-positive, false-positive, false-negative, and true-negative results for the periostin level were extracted from each individual study. We assessed the risk of bias by using Quality Assessment of Diagnostic Accuracy Studies 2. We used the meta-analysis to produce summary estimates of accuracy. Results: In total, nine studies with 1757 subjects met the inclusion criteria. The pooled estimates of sensitivity, specificity, and diagnostic odds ratios for the detection of asthma were 0.58 (95% confidence interval [CI], 0.38‐0.76), 0.86 (95% CI, 0.74‐0.93), and 8.28 (95% CI, 3.67‐18.68), respectively. The area under the summary receiver operating characteristic curve was 0.82 (95% CI, 0.79‐0.85). And significant publication bias was found in this meta‐analysis (p = 0.39). Conclusion: Serum periostin may be used for the diagnosis of asthma, with moderate diagnostic accuracy.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yujing Xin ◽  
Xinyuan Zhang ◽  
Yi Yang ◽  
Yi Chen ◽  
Yanan Wang ◽  
...  

AbstractThis study is the first multi-center non-inferiority study that aims to critically evaluate the effectiveness of HHUS/ABUS in China breast cancer detection. This was a multicenter hospital-based study. Five hospitals participated in this study. Women (30–69 years old) with defined criteria were invited for breast examination by HHUS, ABUS or/and mammography. For BI-RADS category 3, an additional magnetic resonance imaging (MRI) test was provided to distinguish the true negative results from false negative results. For women classified as BI-RADS category 4 or 5, either core aspiration biopsy or surgical biopsy was done to confirm the diagnosis. Between February 2016 and March 2017, 2844 women signed the informed consent form, and 1947 of them involved in final analysis (680 were 30 to 39 years old, 1267 were 40 to 69 years old).For all participants, ABUS sensitivity (91.81%) compared with HHUS sensitivity (94.70%) with non-inferior Z tests, P = 0.015. In the 40–69 age group, non-inferior Z tests showed that ABUS sensitivity (93.01%) was non-inferior to MG sensitivity (86.02%) with P < 0.001 and HHUS sensitivity (95.44%) was non-inferior to MG sensitivity (86.02%) with P < 0.001. Sensitivity of ABUS and HHUS are all superior to that of MG with P < 0.001 by superior test.For all participants, ABUS specificity (92.89%) was non-inferior to HHUS specificity (89.36%) with P < 0.001. Superiority test show that specificity of ABUS was superior to that of HHUS with P < 0.001. In the 40–69 age group, ABUS specificity (92.86%) was non-inferior to MG specificity (91.68%) with P < 0.001 and HHUS specificity (89.55%) was non-inferior to MG specificity (91.68%) with P < 0.001. ABUS is not superior to MG with P = 0.114 by superior test. The sensitivity of ABUS/HHUS is superior to that of MG. The specificity of ABUS/HHUS is non-inferior to that of MG. In China, for an experienced US radiologist, both HHUS and ABUS have better diagnostic efficacy than MG in symptomatic individuals.


2009 ◽  
Vol 8 (4) ◽  
pp. 140-147
Author(s):  
V. N. Piskunov ◽  
V. D. Zavadovskaya ◽  
N. G. Zavyalova

On the grounds of ultrasonography of 275 patients with suspected Acute Appendicitis (AA) the diagnosis was confirmed in 63 (22,9%) cases, it was true-positive results; in 3 (1,1%) cases of non-confirmed AA ultrasound findings were regarded as false-positive results. True-negative results of examination were obtained in 194 cases (70,5%) and false-negative results — in 15 cases (5,5%). The presence of rarevascularity of interior wall and clear visualization of vessels in mesentery of vermiform appendix is typical for congestive appendicitis. When phlegmonous appendicitis there are numerous vascular branches in interior wall blood stream of appendix: they make a picture of color «crown» in horizontal section and color «stripe» in longitudinal section. Gangrenous appendicitis is attached to few color spots in those parts of appendix wall which are not destroyed yet. Vascular pattern in adjacent intestinal loops predominates over vascular pattern of vermiform appendix. In case of empyema vermiform appendix vascular pattern in the wall is detected only in mesentery area. Vascular pattern of appendix is not detected in cases of appendicular infiltrate and periappendicular abscess unlike vascular pattern of adjacent intestinal loops which is rather intensified. The sensitivity of ultrasonography in AA detection was 80,7%, specificity — 98,4%, and accuracy — 93,4%. High index of diagnostic effectiveness of the method was obtained because of adoption of combining B-mode with both Colour Doppler and Power Doppler methods.


2018 ◽  
Vol 10 (3) ◽  
pp. 217-21
Author(s):  
Emy Noerwidayati ◽  
Andaru Dahesihdewi ◽  
Osman Sianipar

BACKGROUND: Klepsiella pneumoniae, one of clinical isolates, is frequently found causative agent of hospital acquired infection. Currently, K. pneumoniae is found as extended-Spectrum β-lactamases (ESBL) producer, allowing it to become multidrugresistant. A clinical laboratory with limited facility needs a valid, reliable, inexpensive and simple laboratory test to control its infection and antimicrobial-resistancy. The aim of this study is to evaluate the diagnostic performance of a ESBL media to detect ESBL-producing K. pneumoniae.METHODS: An independent and blind comparative study of ChromID ESBL media and Double Disc Synergy Test (DDST) was conducted for detecting the clinical isolate of ESBL-producing K. pneumoniae. Clinical isolates of K. pneumoniae collected from the Clinical Laboratory of Dr. Sardjito Hospital were isolated.RESULTS: There were 103 clinical isolates of K. pneumoniae, which were isolated from urine, pus, blood, stool, cerebrospinal fluid, sputum, drain liquid, nasal sinus liquid, gastric wash, bronchi liquid, injury liquid and nasal swab. The number of true positive, true negative, false positive and false negative results were 74, 18, 9 and 2, respectively. Meanwhile, the sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratio for positive result and likelihood ratio for negative result of the new ESBL media were 97.4%, 66.7%, 89.2%, 90%, 2.9 and 0.03, respectively.CONCLUSION: Since the new ESBL media and DDST results were similar, so the new ESBL media could be used for screening patients with clinical presentation that indicating a high suspicious of ESBL-producing bacteria.KEYWORDS: K. pneumoniae, ChromID ESBL, DDST, ESBL, sensitivity


2022 ◽  
Author(s):  
Elsayed Ghannam ◽  
Salah Rozaik ◽  
Ramy Hasan Agwa ◽  
Ahmed Marwan ◽  
Mervat El-Sayed Mashaly ◽  
...  

Abstract Background: Liver is the largest endocrine organ in the body. It is a key organ in insulin mediated metabolism, growth hormone and insulin like growth factors (IGF) pathway. Liver cirrhosis is the end result of many chronic diseases including hepatitis C virus infection. Child-Turcotte-Pugh (CTP) score is the standard used in assessment of hepatic reserve but it has its drawbacks in the form of subjective variables, hepatic encephalopathy and ascites. The aim of this work is to assess IGF-1 in patients with liver cirrhosis, correlate it with CTP score and assess value of modified combined CTP-IGF-1 score. Patients and Methods: 170 patients with CLD (liver cirrhosis) and 72 healthy controls in the study groups were enrolled in the study. All patients were subjected to thorough history, clinical examination and laboratory assessment. IGF-1 was measured and all patients were evaluated using CTP and CTP-IGF-1 scores. Results: IGF1 showed highly significant low values in the study group in comparison to controls (42.15 ± 27.976 and 66.31 ± 33.084 ng/ml respectively, p <0.001). It showed also highly significant negative correlation to CTP score in the study group (p < 0.001) with progressive decrements with CTP score stage progression where IGF1 levels were 48.32 ± 28.611, 40.28 ± 25.869 and 18.80 ± 15.953 ng/ml (mean ± standard deviation) in relation to CTP score groups A, B and C respectively (p value < 0.001). The combined CTP-IGF-1 score in comparison to the classic CTP score showed improved area under curve (0.848 and 0.854), sensitivity (71.2% and 88%), negative predictive value (41.7% and 53.7%), false negative results (49 and 19) and accuracy (75.73% and 83.98%) but decreased specificity (97.22% and 61.1%), positive predictive value (99.2% and 91.5%) and higher false positive results (1 and 14) respectively. Conclusion: IGF-1 show progressive decrements with progression of liver cirrhosis and is negatively correlated with CTP score. Addition of IGF-1 to CTP score to formulate combined score improves the AUC, sensitivity, negative predictive value and the accuracy of CTP score and decreases the false negative results.


Author(s):  
Mohamed Zahran ◽  
Sundus Alsedra ◽  
Daron Cope ◽  
Ahmed Youssef

Abstract Introduction After pleomorphic adenoma, Warthin tumor gets its popularity as the second most common benign neoplasm of the parotid gland. Fine-needle aspiration cytology (FNAC) is the most cost-effective and minimally-invasive way to determine the histological character of a parotid gland tumor. Objective To determine the accuracy of FNAC in the diagnosis of Warthin Tumour. Methods A retrospective study conducted between 2014 and 2018. Out of 243 FNACs performed for parotid lesions, a histopathological correlation was established in 74 cases to reveal the accuracy of FNAC in the diagnosis of Warthin tumor. Results A total of 243 FNACs of parotid lesions were performed, and a histopathological correlation was established in 74 (30.4%) cases. Later on, we confirmed that 16 (21.6%) out of these 74 patients had cases of Warthin tumor. In total, 15 (20.3%) out of those 74 cases were confirmed as Warthin tumors on the initial cytology, which revealed a true positive concordance between the cytology and the final histological diagnosis; 55/74 (74%) were true negative results; on the other hand, 1/74 (1.4%) was a false negative, and 3/74 (4.1%) were false positive results. The sensitivity of the FNAC in the diagnosis of Warthin tumor was of 93%, while the specificity was of 94.8%, and the accuracy, of 94.6%. Conclusion In the present study, FNAC had a high diagnostic accuracy, reaching 94%.


2017 ◽  
Vol 35 (15_suppl) ◽  
pp. 11570-11570
Author(s):  
Shashank Reddy Cingam ◽  
Sean Connor ◽  
Abhishek Harshad Patel ◽  
Samip R. Master ◽  
Amol Takalkar

11570 Background: The increasing use of CT and now low-dose screening CT scans for at-risk patients have led to increasing detection of lung cancer at early stages. FDG PET/CT is used as an adjunct to conventional imaging to assess loco-regional lymph node spread. However, there is a potential for false-negative results, especially in smaller lesions or early nodal involvement. The main objective of this study was to study the value of PET/CT scan to evaluate for true negative mediastinal nodes in patients with early stage NSCLC. Accurate determination of N0 status can have a significant impact on the cost-effectiveness and timely management of early stage NSCLC. Methods: Of a total of 404 patients with NSCLC managed at our facility between 2008 to 2015, 29 adult patients whose PET scan showed no or equivocal mediastinal nodal involvement and subsequently underwent surgical exploration of mediastinal lymph nodes were included in the study. Data variables that were collected included the cancer site, date of PET, node status on PET, type and date of surgery, cancer histology, and the tissue diagnosis of the sampled nodes. SAS software was used for the analysis of the data. Results: Of the 29 patients with N0 or equivocal nodes on FDG PET/CT, 7 (24.13%) had evidence of malignancy on biopsy of the surgically resected lymph nodes. No statistically significant differences were noted between the site of the neoplastic lesion, cancer histology, duration between the date of PET and the date of surgery in the true negative (TN) and false negative (FN) groups. The recurrence rate was higher in the FN group 60 % (3/5) compared to 21 % (4/19) in the TN group who had follow up for atleast 2 years. Conclusions: Our findings suggest incidence of false negative results of FDG PET/CT for evaluation of N0 nodes in early stage NSCLC is 24.13%. This is comparatively higher than false negatives rates with mediastinoscopy (5-10%) reported in other studies. Although our sample size is small, if confirmed, such a relatively high incidence of false negative results on FDG PET/CT for N0 disease supports the current recommendations for exploratory mediastinoscopy and/or surgery for definitive staging in early stage NSCLC.


Author(s):  
Inge-Marié Petzer ◽  
Joanne Karzis ◽  
Edward F. Donkin ◽  
Edward C. Webb

A dedicated udder health diagnostic programme was developed and used over a 15-year period in South Africa to analyse milk samples based on microbiological and cytological patterns within various groups and for individual cows and udder quarters in dairy herds. These pathogen-specific analyses are utilised for pro-active improvement and management of udder health in South African commercial dairy herds. The programme acts as a monitoring tool and identifies management areas at risk and individual cows with udder disease and uses both quarter and composite milk samples. Intra-mammary infection (IMI) is a dynamic situation and depending on the time a milk sample is taken, false-negative results may be obtained. A new IMI and an infection that is curing may both have low somatic cell counts (SCCs), masking the true bacterial status. SCC in individual infected udder quarters may differ greatly depending on the causative bacterial species, its pathogenicity, the host immune status and the environmental factors involved. A pathogen-specific udder health approach was followed with repeated herd tests to take account of these udder health dynamics. The results of the herd IMI investigation are applied in practice to assist veterinarians, udder health consultants and managers to make informed and specific detailed decisions at both a herd and on an individual cow basis regarding udder health.


Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 100
Author(s):  
Victor Mihai Sacerdotianu ◽  
Bogdan Silviu Ungureanu ◽  
Sevastita Iordache ◽  
Adina Turcu-Stiolica ◽  
Antonio Facciorusso ◽  
...  

This study aimed to evaluate the diagnostic value of endoscopic ultrasound (EUS) after neoadjuvant therapy (NT) for gastric cancer restaging by meta-analysis. We conducted a systematic search of studies published on PubMed and Web of Science up to 30th August 2021. Assessing the risk of bias in the included studies was done with the QUADAS-2 tool. We used R and Review Manager 5.4.1 for calculations and statistical analysis. To evaluate the diagnostic value of EUS after NT for gastric cancer restaging, we performed a meta-analysis on six studies, with a total of 283 patients, including true-positive, true-negative, false-positive, and false-negative results for T1-T4, N0. EUS as a diagnostic test for GC patients after chemotherapy has a relatively low DOR for the T2 (3.96) and T4 stages (4.79) and a relatively high partial AUC for the T2 (0.85) and T4 (0.71) stages. Our results reveal that the pooled sensitivity for T stages after chemotherapy is rather low (29–56%), except for the T3 stage (71%). A potential limitation of our study was the small number of included studies, but no significant heterogeneity was found between them. Our meta-analysis concludes that EUS is not recommended or is still under debate for GC restaging after NT.


2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Rafal Z. Slapa ◽  
Antoni Piwowonski ◽  
Wieslaw S. Jakubowski ◽  
Jacek Bierca ◽  
Kazimierz T. Szopinski ◽  
...  

Although elastography can enhance the differential diagnosis of thyroid nodules, its diagnostic performance is not ideal at present. Further improvements in the technique and creation of robust diagnostic criteria are necessary. The purpose of this study was to compare the usefulness of strain elastography and a new generation of elasticity imaging called supersonic shear wave elastography (SSWE) in differential evaluation of thyroid nodules. Six thyroid nodules in 4 patients were studied. SSWE yielded 1 true-positive and 5 true-negative results. Strain elastography yielded 5 false-positive results and 1 false-negative result. A novel finding appreciated with SSWE, were punctate foci of increased stiffness corresponding to microcalcifications in 4 nodules, some not visible on B-mode ultrasound, as opposed to soft, colloid-inspissated areas visible on B-mode ultrasound in 2 nodules. This preliminary paper indicates that SSWE may outperform strain elastography in differentiation of thyroid nodules with regard to their stiffness. SSWE showed the possibility of differentiation of high echogenic foci into microcalcifications and inspissated colloid, adding a new dimension to thyroid elastography. Further multicenter large-scale studies of thyroid nodules evaluating different elastographic methods are warranted.


Sign in / Sign up

Export Citation Format

Share Document